Renovating Your Basement

Similar documents
Basement Insulation Systems

Comment Form on Proposed Gut Rehabilitation Alternatives

Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure

Foundation. Foundation

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Insulating Basements: Part 3 Basement Wall Systems

Additions and Alterations

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

Best Practices for Crawl Space Insulation

Field Performance of Different Interior Basement Insulation Systems

United States. Why You Should Insulate Foundations. There is a science to adding value.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Presented by: Jennifer Doyle, P.E., RRC, LEED AP

The Stay-Dry, No-Mold Finished Basement

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.

bout your HOUSE before you start Renovating Your Basement Moisture Problems

Common Problems with Walls

Best Basement Water Management Practices

How To Repair A Boat Landing Deck With A Boat Bed

STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

BASEMENT INSULATION HOME ENERGY GUIDE

In accordance with the Department of Labor and Industry s statute , Subd. 11,

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

2014 British Columbia Building Code Changes

bout your house before you start Renovating Your Basement Moisture Problems

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

R E S I D E N T I A L H O U S I N G

COMMONLY USED RESIDENTIAL BUILDING CODES

What you need to know about concrete block basement construction.

Residential Foundations and Basements

Signs of insulation problems In the winter. In the summer. conditioning system

The Optimum Basement Wall

Water Damage & Repair

Report on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

CHAPTER 8- REDUCING THE MOISTURE

Keeping the Heat In 6 Basement insulation

BASEMENT INSULATION HOME ENERGY GUIDE

Mold Preventing I nterior System

Basement Insulation: Best Practices for Efficient, Durable, & Healthy Homes

about your house Before You Start Renovating Your Basement Moisture Problems Figure 1 Moisture problems to solve

Fiberglas, Exterior Wall Thermal Insulation

The minimum reinforcement for the stem wall is the placement of:

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

Waterproofing and interior insulation for basements takes new twist in technology.

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

State of Connecticut Department of Public Health RADON PROGRAM

A Builder s Guide to Residential. Foundation Insulation. Uninsulated Foundations Cause Condensation. Uninsulated Foundations Loose a Lot of Energy

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Post-insulation of cellar ceiling and cellar walls

Performance of 8 Passive House Envelopes in Cold Climates

Insulation Products For Residential Thermal Applications ROXUL. Better Best ROXUL. Solutions For Residential Thermal Applications.

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

CLOSED CRAWLSPACES. Have you ever been in your crawlspace? If not, have you ever even

DELTA Premium Moisture Management Systems for Foundations.

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

Molds and mildew are fungi that grow

MUNICODE SERVICES LTD.

CHAPTER 7: Building Systems ROOFING SYSTEMS

The Ultimate Guide To Protecting Your House From Water In The Basement

The Case for Cross Laminated Timber: Part 2

Options in the Selection of Materials for Basement Construction

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

COMMERCIAL BUILDING APPLICATIONS

CONDENSATION IN REFRIDGERATED BUILDINGS

HOW TO INSULATE A CRAWLSPACE

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Basement Moisture Problems

More Bang for Your Buck: Combining Thermal, Air and Water Barrier

Guide Specifications for Maple Flooring Systems

Housing Fact Sheets. Insulation Check-Up

bout your HOUSE before you start Renovating Your Basement Structural Issues And Soil conditions

ECHO System for Basements

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

Refrigeration Installation 101

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

BEST 2 WB 3 4 SIX WAYS FOR CONDENSATION IN BUILDINGS. Wagdy Anis, FAIA, LEED ap*

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

Measure Guideline: Basement Insulation Basics

Insulation R-Value Comparisons

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

ROOFS, SNOW AND ICE DAMS

Retrofitting an Insulated Cold Roof

Transcription:

building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract: Heat loss through uninsulated basement walls can account for up to one-third of the heat loss from an average home. Installing insulation on basement walls is often inexpensive, easy to accomplish and frequently combined with finishing the basement.

Heat loss through uninsulated basement walls can account for up to one third of the heat loss from an average home. Installing insulation on basement walls is often inexpensive, easy to accomplish and frequently combined with finishing the basement. Unfortunately, basement walls are often damp or are only dry on the surface because of evaporation of water into the basement air. Installing wood framing or fiberglass batts directly against basement walls subsequently leads to mold growth and decay of the wood due to fungal growth. Insulating basement walls can be safely accomplished by assessing the moisture conditions of these walls and applying some basic building science to the design process. If walls are visibly wet at times or water occasionally drains from the walls onto the floor, an interior drain system should be installed before insulating and finishing the basement. This requires cutting the concrete floor to remove the outer 12 inches which permits the installation of a drainage system below the concrete slab as shown in Figure 1. If walls are periodically damp but never have water flowing down them, omitting the interior drainage system can be considered. In this situation compare the cost of installing the drainage system to the cost of replacing the finished floor if it gets wet. The building science principles that apply to insulating basement walls and floors include the following: 1. Moisture sensitive materials such as wood, paper and fiberglass batts should not be installed in direct contact with concrete or masonry walls and floors. 2. Moisture tolerant materials that also do not absorb liquid water should be installed in contact with concrete and masonry surfaces. These materials will not deteriorate if they get wet and they also will not wet moisture sensitive materials that are in contact with them. Renovating Your for moisture control and to improve energy efficiency XPS or foil-faced polyisocyanurate Existing concrete wall 2 XPS rigid foam insulation (unfaced) tape all joints - adhere to foundation wall 2x3 24 o.c. wood stud wall attached to floor and floor joists 1/2 gypsum wall board; hold up from floor 1/2 minimum Capillary break Remove/replace with new 18 of existing concrete slab for reconstruction purposes Either one layer 1/2 plywood - mechancially fastened to slab; or two layers of 1/2 plywood, joints offset, second layer glued 1 XPS rigid foam insulation (unfaced); tape all joints Existing concrete slab 4 perforated drain tile placed in free draining stone trench lined with geo textile fabric Figure 1 XPS plus frame wall and interior drain 3. Moisture tolerant insulation installed in an airtight manner on basement walls and floors warms the first condensing surface above the dew point of the interior air. This reduces the probability of warm moist air condensing on cool surfaces. of 3

The best insulation to install on basement walls in many homes is extruded polystyrene that comes in sheet or panels, 2-feet or 4-feet in width by 8- or 9-feet high. Extruded polystyrene (XPS) provides an R-value of 5 per inch, is moisture tolerant, and does not absorb liquid Impermeable backfill water, but does allow water vapor (water molecules in the gas state) to slowly pass through it. Free-draining backfill The semipermeable nature of XPS allows some Damp-proofing drying of moisture through the panel but at a Filter fabric rate that is slow enough to prevent wetting of materials on the dry side of the assembly. Coarse gravel (no fines) Perforated drain pipe Ground slopes a ay from all at ( in per ft ) The main disadvantage of XPS is that it is flammable and therefore must be protected by a 15 minute thermal barrier such as 0.5 inch of gypsum board. In a below grade space such as a basement, a gypsum board without paper facings is recommended. The extruded polystyrene sheets can be held in place by wood furring strips that are attached through the XPS with power driven nails or screws. Gypsum board or other thermal barriers are then attached to the furring strips. The joints between sheets of insulation should be sealed with tape or fiberglass mesh and mastic. Another option is to install one inch of XPS and then build a 2X3 or 2X4 frame wall just interior to the XPS. Unfaced fiberglass batts can be installed in the frame wall for additional insulation. These details are shown in Figure 1. Closed cell sill seal should be installed between the bottom plate of the wall and the concrete floor. Figure 2 shows 2 inches of XPS insulation held in place by furring strips. Note that no perimeter drainage system has been installed. The thickness of the XPS will depend upon the climate and whether additional insulation will be added in a frame wall. We recommend a minimum of 1 inch of XPS up to a maximum of approximately 2 inches. hotograph 1 shows a basement wall with 1 inch of extruded polystyrene that is trapped in place by the additional wood frame wall. Photograph 2 shows a basement wall with 2 inches of extruded polystyrene, joint sealed with tape and held in place by furring strips. The XPS was initially held in place by adhesive, but building codes require that the insulation be mechanically attached to the wall. Sealant ad esive or gasket Sill gasket Sealant Concrete footing Capillary break over footing (damp-proofing or membrane) Concrete foundation all nfaced e truded or e panded polystyrene rigid insulation (semi-permeable it taped or sealed oints) Gypsum board t erma l barrier necessary en rigid insulation is not rated for e posed application Gypsum board over furring strips Gypsum board eld up from slab Concrete slab Granular capillary break and drainage pad (no fines) Figure 2 XPS fastened with furring strips and covered with gypsum sheathing P Photograph 1 XPS against basement wall with framed wall of 3

Since basement floors can have moisture problems similar to those described for basement walls, the moisture characteristics of a concrete basement slab must be assessed before installing a finished floor. floors may appear to be dry but only because ground moisture passing through the slab is evaporating into the interior air space. If this is the case, installation of impermeable flooring may lead to the accumulation of water on the surface of the slab or in the flooring material. Water may also be condensing on the surface of the concrete when the surface temperature of the slab is cooler than the dew point of the basement air. The deep ground temperature of the slab is cooler than the dew point of the basement air. The deep ground temperature under a basement slab is frequently near 55 F throughout the year. Poor interior humidity control or the introduction of exterior air during spring and summer may result in dew points above 55 F. When condensation occurs on unfinished concrete the moisture is quickly absorbed by the concrete and is never visible. Painting the concrete surface or installing thin tile may result in accumulation of a thin layer or water on the surface of the floor. P Renovating Your for moisture control and to improve energy efficiency Photograph 2 XPS against basement wall with furring strips roperly insulating a concrete slab can provide a warm dry surface on which carpet or other flooring can be installed. If a concrete slab is in good repair and does not have significant water problems (liquid water on the surface) sheets of extruded polystyrene can be installed directly on the slab. The joints between sheets should be sealed with tape or mesh imbedded in mastic. A plywood floor can then be floated over the XPS insulation in either of two ways. If sufficient room height is available wood sleepers (2X4 or other dimensional lumber) can be installed to which the flooring is mechanically fastened. This is illustrated in Photograph 3. If room height is minimal, tongue and groove plywood with the butt ends of the plywood joined can float above the XPS insulation. Wood biscuits are one method for jointing the butt ends so that one sheet cannot ride up above the next sheet. I f the concrete slab is in poor condition a new concrete slab can be placed over rigid extruded polystyrene insulation. Since the XPS is vapor retarder, no polyethylene vapor barrier is needed under the new concrete slab. If significant moisture is present on the old concrete slab, a drainage mat can be placed under the new concrete slab. The drainage mat provides a pathway for water to move laterally to the interior drainage system. Soil gases such as radon could potentially be evacuated from the space created by the drainage mat. Photograph 3 XPS installed over basement slab; wood sleepers will support plywood flooring 3 of 3

Renovating Your About this Report This report was prepared for the US Department of Energy s Building America Program. Direct all correspondence to: Joseph Lstiburek, Building Science Corporation, 70 Main Street, Westford, MA 01886 Limits of Liability and Disclaimer of Warranty: Building Science documents are intended for professionals. The author and the publisher of this article have used their best efforts to provide accurate and authoritative information in regard to the subject matter covered. The author and publisher make no warranty of any kind, expressed or implied, with regard to the information contained in this article. The information presented in this article must be used with care by professionals who understand the implications of what they are doing. If professional advice or other expert assistance is required, the services of a competent professional shall be sought. The author and publisher shall not be liable in the event of incidental or consequential damages in connection with, or arising from, the use of the information contained within this Building Science document.