Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology



Similar documents
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique

The Right Choice. Exeter. total hip system

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Zimmer Gender Solutions NexGen High-Flex Implants

Minimally Invasive Hip Replacement through the Direct Lateral Approach

High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System

Posterior Referencing. Surgical Technique

BONE PRESERVATION STEM

Introduction to the Bertram Hip Spacer

Metasul LDH Large Diameter Head

Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability

P REPLACEMENT SURGERY

Accolade. System. Brochure. Achieving Perfect Balance. Cemented and Cementless Femoral Hip System

Clinical performance of endoprosthetic and total hip replacement systems

Performance evaluation of CLS Brevius Stem with Kinectiv Technology

Predictive Value of Robotic-Assisted Total Hip Arthroplasty

on-metal Hips: Device Mechanics and Failure Modes

Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique

Why an Exactech Hip is Right for You

Taperloc Complete Hip System

ReCap Product Rationale

Restoration Modular. Revision Hip System Surgical Protocol

Metal-on-Metal Hip Systems

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal

Total hip arthroplasty (THA) through the anterior approach

ACCOLADE II. Orthopaedics. Femoral Hip System. Surgical Technique

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

Aesculap Orthopaedics Metha

PERIPROSTHETIC IMPLANTS

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

SCIENTIFIC PAPER Anterior Dislocation Following Primary Total Hip Replacement by the Posterior Approach Aetiology and Treatment

Total Hip Joint Replacement. A Patient s Guide

Rejuvenate Total Hip System Surgical Protocol. Rejuvenate Modular Hip Stem Enhanced Stability 1 Proven Modularity 2 Intraoperative Flexibility

CPT 12/14 Hip System. Primary Hip Athroplasty Surgical Technique

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

The information contained in this document is intended for healthcare professionals only.

EMPLOYMENT: PEACHTREE ORTHOPAEDIC CLINIC ATLANTA- GA PRESENT Orthopaedic Surgeon Northside Hospital, Atlanta, GA

Clinically Proven Fiber Metal Material. Power to choose advanced bearing technologies to match patient demands

Simplified surgery. Personalized performance.

Failure Mechanisms and Closed Reduction of a Constrained Tripolar Acetabular Liner

Acetabular Wedge Augment System

AN AUTOMATED SIZE RECOGNITION TECHNIQUE FOR ACETABULAR IMPLANT IN TOTAL HIP REPLACEMENT

Digital templating facilitates accurate leg length correction in total hip arthroplasty

PINNACLE. Polyethylene Surgical Technique. Surgical Technique

Corporate Medical Policy Computer Assisted Surgical Navigational Orthopedic Procedures

Computer-Assisted Navigation and Musculoskeletal Sarcoma Surgery

How To Fix A Radial Head Plate

Design surgeon list. Smith & Nephew thanks the following surgeons for their participation as part of the R3 system design team:

Joint Revision Surgery - When Do I Need It?

Anterior Hip Replacement

Structure and Function of the Hip

Orthopaedic Surgeon, Dr B. Private Hospital. District Health Board. A Report by the. Health and Disability Commissioner.

frequently asked questions Knee and Hip Joint Replacement Technology

When is Hip Arthroscopy recommended?

Hip Resurfacing 2011 ORIGINAL ARTICLE. James W. Pritchett MD. Introduction. Abstract

FEMORAL NECK FRACTURE FOLLOWING TOTAL KNEE REPLACEMENT

Malrotation Causing Patellofemoral Complications After Total Knee Arthroplasty

Total Hip Replacement

Robotic-Arm Assisted Surgery

Product overview and surgical technique

Your Practice Online

YOUR GUIDE TO TOTAL HIP REPLACEMENT

Wagner Cone Prosthesis Hip Stem. Surgical Technique

Knotilus TM. Anchor Instability Repair. Technique Guide

Femoral Acetabular Impingement And Labral Tears of the Hip James Genuario, MD MS

Zimmer PSI Knee System For Use with the NexGen Complete Knee System Surgical Technique

CPT 12/14 HIP SYSTEM LONG STEMS. Surgical Technique for Femoral Revision

MINIMALLY INVASIVE TOTAL HIP REPLACEMENT VANDERBILT UNIVERSITY MEDICAL CENTER, NASHVILLE, TN Broadcast April

Luigi Vito Stefanelli,D.Eng.,DDS

Rehabilitation Protocol: Total Hip Arthroplasty (THA)

Treatment of hip dysplasia in children with. Terje Terjesen Department of Orthopaedic Surgery Oslo University Hospital, Rikshospitalet

Kaiser Permanente. National Total Joint Replacement Registry. Liz Paxton Director of Surgical Outcomes & Analysis

NCB Periprosthetic Femur Plate System. Surgical Technique

Features and Benefits at a Glance Standard Features ExclusiveTable Maneuverability Superior Imaging High Stability Ordering Information

Understanding Total Hip Replacement

The Journal of Arthroplasty

DHCPL_RA EXT Page 1 of 6

Oxford Partial Knee. A Definitive Implant. Tibial Component. Anatomical shape for optimal bone coverage

ABG II Modular. Anatomic Reconstruction

Zimmer Periarticular Proximal Tibial Locking Plate

TRIGEN INTERTAN vs Stryker Gamma3 summary

Trabecular Metal Femoral Component. Surgical Technique

THE MEASUREMENT AND ANALYSIS OF AXIAL DEFORMITY AT THE KNEE

Exeter X3 RimFit. Acetabular Cup Surgical Protocol

3D Visualization of Pre-operative Planning for Orthopedic Surgery

MDM. Surgical Technique. Modular Dual Mobility Acetabular System. Orthopaedics


Complex Primary to Revision Hip Arthroplasty

Total Elbow Arthroplasty and Rehabilitation

Zimmer Trilogy IT Acetabular System

Single Stage Revision Joint Replacement for Infection

Zimmer Persona Adverse Events Reported to FDA Through 3/27/2015

Imagine being an orthopedic surgeon and knowing that your patient s

More than a fixed rehabilitation.

Mid-term results for hip resurfacing in patients under 30 years old with childhood hip disorders

No IN THE APPELLATE COURT OF ILLINOIS FIRST JUDICIAL DISTRICT

CuttingEdge Hip Instrumentation Femoral Surgical Technique for Primary Press-Fit and Cemented Hip Implants.

MIS Direct Anterior Approach Surgical Protocol

HEADER TOTAL HIP REPLACEMENT SURGERY FROM PREPARATION TO RECOVERY

Transcription:

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology Hips designed to fit the unique anatomies of men and women

Independent control for a natural fit Simple, practical solutions for optimal restoration of hip joint kinematics Restoring leg length, joint stability, and range of motion involve distinct surgical challenges. The Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology is a system of modular stem and neck components designed to help the surgeon restore the natural hip joint center intraoperatively by addressing leg length, offset, and version independently. The broad array of neck options efficiently targets a wide range of male and female patient anatomies. Built on the proven M/L Taper design philosophy The collarless prosthesis incorporates the bone-conserving design and tapered wedge fixation philosophy of the Zimmer M/L Taper Hip Prosthesis. Simple technique. MIS-enabled. Implants and instrumentation with Kinectiv Technology are designed to facilitate insertion and assembly during minimally invasive THR procedures while minimizing soft-tissue trauma. They provide simple intraoperative flexibility in adjusting head center location and optimizing hip kinematics.

Gender Solutions Technology The Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology helps the surgeon address a wide range of bone morphologies. For example, women tend to have lower head centers, less offset, and greater anteversion, whereas men tend to have greater offset and less anteversion. 1-7 These gender-specific tendencies are addressed by offering a broad range of head centers and progressively increasing version for shorter offset head center locations to better match the anatomical differences between men and women. Head center data Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology addresses both male and female bone morphology. Male Female Zimmer M/L Taper with Kinectiv Technology +0mm head centers Plotting head height and offset reveals two distinct populations: female and male.

The kinematic connection Kinectiv Technology allows simple independent adjustment of the three key kinematic dimensions leg length, offset, and version to restore appropriate kinematics and help improve overall patient satisfaction. Using only a +0mm femoral head component, the system offers 60 different head center locations with varus, valgus, anteverted, and retroverted head center solutions to help restore accurate joint kinematics. After implanting the stem based on the most desirable proximal stem fit, the surgeon selects the appropriate modular neck that provides the desired combination of leg length, offset, and version. Adjustment of each dimensional factor is achieved independently, allowing the surgeon to optimize leg length, range of motion, and joint stability. Preoperative templating establishes precise head center location, while Kinectiv Technology facilitates accurate head center positioning.

Head center grids located on the tray corners correspond to the head center options shown on the templates. Leg length and offset can both be adjusted for left and right THA using the same provisional tray. Adjust leg length without affecting offset Leg length discrepancy is a leading source of patient dissatisfaction. 8-11 Adjust offset without affecting leg length Proper leg length and offset restoration improve total hip replacement function and minimize 12-13 the risk of dislocation and limp.

Independent, intraoperative version adjustment The Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology allows independent version adjustments after stem implantation. This facilitates optimal stem position based on the patient s proximal femoral anatomy. Optimized version without compromising stem orientation Stem: non modular, straight neck Disadvantage: cannot adjust for version following stem implantation Stem: modular, straight neck Stem: modular, anteverted neck Advantage: optimized version following stem implantation Optimized range of motion Dislocation can occur up to four times more often in women, 2,7,14-15 and is a costly complication in total hip replacement. 16 Furthermore, component-on-component impingement has been shown to contribute to accelerated wear of the liner. The Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology is designed to reduce the incidence of impingement and dislocation by optimizing range of motion. 7,17-19 Range of motion is enhanced by the reduced neck geometry and the ability to achieve the desired head center location without the need for skirted femoral head components. Reduced neck geometry

Intraoperative flexibility When cup placement is not optimal, Kinectiv Technology allows the surgeon to optimize range of motion intraoperatively by adjusting version without affecting leg length or offset. Straight neck with neck impingement Neck impingement Straight neck Neutral position Straight neck Flexion, abduction, and external rotation Anteverted neck resolves neck impingement No impingement Anteverted neck Neutral position Anteverted neck Flexion, abduction, and external rotation

Instrumentation designed for simplicity Locking Stem Inserter provides easy, straight-forward stem insertion. 90 A simple 90-degree rotation of the provisional neck tray allows the use of the same provisional sets for both right and left hips. Advancing skills and knowledge The Zimmer Institute, in true teamwork with the surgeon, provides hands-on training and transfer of knowledge to bring the benefits of minimally invasive surgery to joint replacement partners. The Zimmer Institute and its satellite programs work with surgeons, offering support for procedures from the familiar to the highly advanced. Zimmer training and support enhance the skills and knowledge of surgeons at every stage of their career, so they have confidence in the Zimmer MIS Procedures they perform. Straight provisional tray References 1. Noble PC, Box GG, Kamaric E, Fink MJ, Alexander JW, Tullos HS. The effect of aging on the shape of the proximal femur. Clin Orthop. 1995;316:31-44. 2. Maruyama M, Feinberg JR, Capello WN, D Antonio JA. Morphologic features of the acetabulum and femur: anteversion angle and implant positioning. Clin Orthop. 2001;393:52-65. 3. Data from Mohamed Mahfouz, PhD, University of Tennessee Center for Musculoskeletal Research. Femoral Bone Atlas. 4. Data on file at Zimmer. Version provisional tray 5. Sugano N, Noble PC, Kamaric E. Predicting the position of the femoral head center. J Arthroplasty. 1999;14:102-107. 6. Dorr LD, Long WT, Inaba Y, Sirianni L, Boutary M. MIS total hip replacement with a single posterior approach. Seminars in Arthroplasty. 2005;16:179-185. 7. Malik A, Maheshwari A, Dorr LD. Impingement with total hip replacement. J Bone Joint Surg. 2007;89:1832-1842. 8. Konveys A, Bannister GC. The importance of leg length discrepancy after total hip arthroplasty. J Bone Joint Surg (Br). 2005;87-B:155-157. 9. Hoffmann AA, Skrzynski MC. Leg length inequality and nerve palsy in total hip arthroplasty: a lawyer awaits! Orthopedics. 2000;9:943-944. 10. White AB. AAOS committee on professional liability: study of 119 closed malpractice claims involving hip replacement. AAOS Bulletin. July 1994. 11. Bal BS. Managing litigation risk in minimally invasive total joint surgery. AAOS Bulletin. April 2006. 12. Iorio R, Healy WL, Warren PD, Appleby D. Lateral trochanteric pain following primary total hip arthroplasty. J Arthroplasty. 2006;21:233-236. 13. Bourne RB, Rorabeck CH. Soft tissue balancing the hip. J Arthroplasty. 2002;17(suppl 1):17-22. 14. Morrey BF. Instability after total hip arthroplasty. Orthop Clin N Am. 1992;23:237-248. 15. Morrey BF. Difficult complications after hip joint replacement: dislocation. Clin Orthop. 1997;344:179-187. 16. Sanchez-Sotelo J, Haidukewych GJ, Boberg CJ. Hospital cost of dislocation after primary total hip arthroplasty. J Bone Joint Surg. 2006;88- A:290-294. 17. Shon WY, Baldini T, Peterson MG, Wright TM, Salvati EA. Impingement in total hip arthroplasty: a study of retrieved acetabular components. J Arthroplasty. 2005;20:427-435. 18. Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stöckl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg (Br). 2005;87-B:762-769. 19. D Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg. 2000;82-A:315-321. Contact your Zimmer representative or visit us at www.zimmer.com +H124977713001001/$071019J079 97-7713-001-00 7.5ML Printed in USA 2007 Zimmer, Inc.