Predictive Value of Robotic-Assisted Total Hip Arthroplasty
|
|
|
- Caren Cameron
- 10 years ago
- Views:
Transcription
1 Predictive Value of Robotic-Assisted Total Hip Arthroplasty Youssef F. El Bitar, MD; Timothy J. Jackson, MD; Dror Lindner, MD; Itamar B. Botser, MD; Christine E. Stake, MA; Benjamin G. Domb, MD abstract Acetabular cup positioning, leg-length discrepancy, and global offset are important parameters associated with outcomes following total hip arthroplasty (THA). Deviation from an accepted range of values can lead to significant complications, including dislocation, leg-length discrepancy, impingement, accelerated bearing surface wear, and revisions. The purpose of this study was to assess whether robotic-assisted THA was reliable in predicting radiographic measurements of cup inclination and anteversion, leg-length change, and global offset change. All 61 robotic-assisted THAs that met the inclusion and exclusion criteria were performed by a single surgeon through a miniposterior approach. Data provided by the robot were collected prospectively, and radiographic data were collected retrospectively by 2 blinded independent reviewers. The cohort in this study consisted of 27 male and 34 female patients, with an average age of 60.5 years. A strong inter- and intraobserver correlation was found for the radiographic measurements of cup inclination, cup anteversion, leg-length discrepancy, and global offset (r>0.8 with P<.001 for all). Ninety-six point seven percent of roboticmeasured inclination angles and 98.4% of robotic-measured anteversion angles were within 10 of radiographic measurements. One hundred percent of robotic-measured leg-length change and 91.8% of robotic-measured global offset change were within 10 mm of radiographic measurements. Robotic-assisted THA showed good predictive value for cup inclination and anteversion angles and measurements of leg-length change and global offset change done postoperatively on plain radiographs. Further refinement of the robotic system would make it more accurate in predicting the postoperative parameters mentioned. [Orthopedics. 2015; 38(1):e31-e37.] The authors are from Loyola University, Chicago; Hinsdale Orthopedics, Westmont; and the American Hip Institute, Westmont, Illinois. Drs El Bitar, Jackson, Lindner, and Botser and Ms Stake have no relevant financial relationships to disclose. Dr Domb is a paid consultant for Arthrex, Inc and MAKO Surgical Corp. The authors thank Jennifer C. Stone, MA; Anthony P. Trenga, BA; and Adam Y. Sadik, BS, for help with data collection and management. Correspondence should be addressed to: Benjamin G. Domb, MD, Hinsdale Orthopedics, 1010 Executive Ct, Ste 250, Westmont, IL ([email protected]). Received: June 21, 2013; Accepted: April 8, 2014; Posted: January 19, doi: / e31
2 The overall burden of total joint arthroplasty is expected to increase significantly over the next 2 decades, with a projected 572,000 primary total hip arthroplasties (THAs) and 96,700 revision THAs in the year Therefore, every effort should be directed at providing the best possible THA to avoid revisions and ensure a long-lasting prosthesis with good quality of life for patients with hip osteoarthritis. Acetabular cup positioning, leg-length discrepancy, and global offset are important parameters that play a significant role in the success and longevity of THA. Proper acetabular cup placement is a critical step when performing THA, regardless of the approach used or the implant type. Placing the cup outside a safe zone of inclination and anteversion 2,3 can result in multiple complications, including dislocation, 2-4 leg-length discrepancy, 5 impingement, 6 accelerated bearing surface wear, 7 and revisions. Leg-length discrepancy is currently one of the most common orthopedic complications associated with medical litigation. 8 Leg-length discrepancy of more than 1 cm is considered a significant source of adverse clinical sequelae, including nerve palsies, 8,9 abnormal gait, 10 and low back pain. 11 Maintaining an adequate global offset is important for optimal mechanical function of the hip joint. Deviating from an acceptable range of global offset can result in several complications. Decreasing the global offset can lead to limping, 12,13 Trendelenburg gait, 12,13 and increased wear, 12,14 whereas an increase in global offset can result in increased wear, 14 pain, 15 and leg-length discrepancy. 16 Computer-assisted surgery has been gaining significant popularity over the past few decades in the field of arthroplasty. The need to address individual variations in hip anatomy has led to the development of patient-specific surgeries. 17 These relatively new technologies allow for preoperative planning and intraoperative execution tailored to every patient s anatomy. Robotic-assisted THA, 18,19 image-assisted navigation, 20,21 and imageless navigation 22 have all been introduced into the field of THA for the purpose of decreasing technical errors intraoperatively. The purpose of this study was to assess whether the use of the MAKOplasty Total Hip Application (MAKO Surgical Corp, Ft Lauderdale, Florida) was reliable in predicting postoperative radiographic measurements of cup inclination, cup anteversion, leg length, and global offset in THA. Materials and Methods All robotic-assisted THAs performed between June 2011 and December 2012 by the senior surgeon (B.G.D.) through a mini-posterior approach were reviewed. Patients with proper postoperative supine anteroposterior (AP) pelvis radiographs were included in the study. Excluded patients were those who had missing or improper postoperative radiographs (rotated or tilted pelvis) 23 or had radiographs with at least 1 lesser trochanter that was hard to define. Sixty-one cases of roboticassisted THA met the inclusion and exclusion criteria. Investigational review board approval was obtained prior to initiation of this study. Patients scheduled for robotic-assisted THA underwent preoperative computed tomography (CT) scan of the involved hip. The robotic system created a patientspecific virtual 3-dimensional (3-D) model of the pelvis and proximal femur that was used to guide surgery. Patient-specific landmarks were then defined and used intraoperatively to determine the position of the pelvis and proximal femur. This system involved a haptic robotic arm for acetabular reaming and cup placement and gave the surgeon real-time feedback regarding cup position, leg length, and global offset. The robotic system software took into consideration pelvic tilt and rotation in determining intraoperative measurements. These were calculated on the coronal (functional) plane of the body as described by Murray. 24 The acetabular implant used in all 61 cases was the Restoris Trinity Cup (Corin Group PLC, Cirencester, United Kingdom). The femoral stem used was the MetaFix Hip Stem (Corin Group PLC) in 39 cases and the Anthology Stem (Smith & Nephew, London, United Kingdom) in 22 cases. Stem choice was based on preoperative templating to determine the best fit to the femur. This was a radiographic study with no clinical outcomes measured and no long-term patient follow-up. Trauma-Cad software (Voyant Health, Petach-Tikva, Israel) was used for all radiographic measurements, including leg-length discrepancy, global offset, acetabular cup inclination, and version. The measurements were done on the AP pelvis view following the coronal plane of the body 24,25 (Figure 1) after calibration. Trauma-Cad software has been previously studied and its accuracy reported in the literature. 26,27 This software allows for the measurement of the version angle on the AP view of the pelvis but cannot differentiate between anteversion and retroversion. To determine the direction of version, the authors used the postoperative cross-table lateral radiographs of all patients, a technique described by Woo and Morrey. 28 For leglength discrepancy measurements, the authors used the interobturator line (line tangent to the inferior aspect of both obturator foramina) as a reference on the pelvis, and the most superomedial point on both lesser trochanters as the references on the femurs. For global offset measurements, they used the technique described by Dastane et al. 16 Two observers (Y.F.E. and T.J.J.), blinded from each other s results, collected the radiographic data to determine interobserver reliability. Each observer performed the measurements twice, 2 months apart, to determine intraobserver reliability. Cup inclination and anteversion angles were measured on the postoperative AP pelvis radiographs. To measure radiographic leglength change, leg-length discrepancy was e32 ORTHOPEDICS Healio.com/Orthopedics
3 measured on the pre- and postoperative radiographs. Subtracting the preoperative from the postoperative leg-length discrepancy provided the radiographic leg-length change in the operated on extremity. The same principle was applied to measure radiographic global offset change. Sixty-one cases of robotic-assisted THA were included. All cases had available cup inclination and anteversion data measured by the robotic system intraoperatively. Because the robotic system software was still under development when the authors adopted its use at their institution, 12 of the first cases did not have intraoperative measurements of leglength change and global offset change. Measuring cup inclination and anteversion intraoperatively was possible from the beginning with the first version of the software. Measuring leg-length change and global offset change became possible with later versions, allowing the authors to gather 49 cases with all 4 measurements. SPSS version 20 statistical software (SPSS, Inc, Chicago, Illinois) was used to perform all statistical analyses in this study. The means of all the radiographic parameters measured by both observers were calculated. Pearson s correlation coefficient was used for intra- and interobserver reliability analyses. Demographic data of the authors patient cohort were reported as well. Calculation of the mean and range was done for all the robotic and radiographic measurements of all parameters studied. Comparison between the robotic and postoperative radiographic measurements was performed. Student s t test was used to compare the means of cup inclination, cup anteversion, leg-length change, and global offset change. The percentages of robotic-measured cup inclination and anteversion angles that fell within 5, 10, and greater than 10 of radiograph-measured angles were calculated. The percentages of robotic-measured leg-length change and global offset change measurements that fell within 5, 10, and greater than 10 mm of radiograph-measured values were calculated. Student s t test was used for comparison between pre- and postoperative radiographic leg-length discrepancy and global offset. The percentages of cases that had radiograph-measured leg-length discrepancy within 5, 10, and greater than 10 mm were reported. A P value less than.05 was considered statistically significant. Results The study cohort comprised 27 males and 34 females. There were 31 right THAs and 30 left THAs. Mean patient age was 60.5 years (range, 39.5 to 90.5 years). Postoperative cross-table lateral radiographs were analyzed, and all patients were found to have anteverted cups. Therefore, all version measurements given by the Trauma-Cad software were true anteversion measurements. The inter- and intraobserver Pearson correlation coefficients (r) for all radiographic measurements were all greater than 0.8 (P<.001 for all). A Figure 1: Supine anteroposterior pelvis radiograph showing measurements for cup anteversion and inclination angles. Line B is the tangent line to the opening of the acetabular cup and intersects with the interobturator reference line A on the pelvis, giving the inclination angle (37 ). The ellipse that measures the anteversion angle (18 ) is delineated by the contour of the acetabular cup opening and is concentric with the circle surrounding the acetabular cup (A). Supine anteroposterior pelvis radiograph showing measurements for leg-length discrepancy and global offset. Line A is the reference on the pelvis. Leglength discrepancy of 5 mm is the difference between lines B and C. Line D delineates the anatomic axis of the femur, and line E is parallel to the anatomic axis, tangent to the teardrop (or to the most medial aspect of the acetabular cup when the cup is more medial than the teardrop). The perpendicular distance between lines D and E passing through the center of the femoral head gives the global offset value of 67.9 mm (B). Cup Inclination and Anteversion Mean inclination and anteversion angles for the robotic and radiographic measurements are reported in Table 1, as well as the comparison between the robotic- and radiographic-measured angles. The percentages of robotic-measured angles within 5, 10, and greater than 10 of radiographicmeasured angles are shown in Figure 2A. Leg-Length Discrepancy, Change in Leg Length, Global Offset, and Change in Global Offset Mean postoperative radiographic leglength discrepancy is reported in Table 2. The percentages of cases that had radiographic postoperative leg-length discrepancy within 5, 10, and greater than 10 mm are shown in Figure 2B. Mean leg-length change and global offset change for the robotic and radiographic measurements are reported in Table 2. The percentages of cases that had radiographic leg-length change or global offset change within 5, 10, and greater than 10 mm are shown in Figure 2C. Comparison between the robotic- and radiographic-measured leg-length change and global offset change is reported in Table 2. The percentages of roboticmeasured leg-length change and global offset change within 5, 10, and greater than 10 mm of radiographic measurements are shown in Figure 2D. B e33
4 Few technical difficulties were encountered using the robotic system. One case necessitated repeat femoral registration due to failure of the first registration. The robotic system had automated double-checks that detected if the patientspecific 3-D hip model matched the intraoperative digitalized check points. The final outcome was not affected in this case, and the cup was found to be within the safe zone. 2,3 In another case, the cup using robotic guidance was judged to be placed Table 1 Anteversion and Inclination Measurements (N=61) Measurement Mean±SD 95% CI P Inclination Robotic-measured 38.9 ± Radiographic-measured 40.3 ± Robotic- vs radiographic-measured 3.2 ± Anteversion Robotic-measured 20.3 ± Radiographic-measured 16.9 ± Robotic- vs radiographic-measured 3.8 ± <.001 Abbreviation: CI, confidence interval. C A Figure 2: Comparison of robotic-measured inclination and anteversion angles with radiographic-measured angles (A). Leg-length discrepancy (LLD) on postoperative radiographs (B). Radiographic-measured leglength change (LLC) and global offset change (GOC) (C). Comparison of robotic-measured leg-length change (LLC) and global offset change (GOC) with radiographic-measured distances (D). outside the safe zone. This judgment was based on the traditional intraoperative landmarks, including bony landmarks, the transverse acetabular ligament, and the alignment guide. The cup was repositioned in the conventional way and found to be within the safe zone. 2,3 Discussion The current authors evaluated the ability of the robotic system to estimate the postoperative radiographic parameters of B D cup inclination and anteversion, as well as the change in leg length and global offset. Ninety-six point seven percent of robotic-measured values were within 10 of radiographic-measured values for inclination angle, 98.4% were within 10 for anteversion angle, 100% were within 10 mm for leg-length change, and 91.8% were within 10 mm for global offset change. One hundred percent of cases had radiographic leg-length discrepancy less than 10 mm, 100% had radiographic leglength change less than 5 mm, and 73.5% had radiographic global offset change less than 5 mm. Precise placement of components and reconstruction of biomechanics 11,16 is an important goal of THA. Placing the acetabular cup in the safe zone 2,3 and minimizing changes in leg length 11 and global offset 16 have been proven to decrease short- and long-term complications and improve long-term survivorship of the implant. Computer-assisted surgery has been introduced to decrease technical error and improve consistency and accuracy in performing THA. 22,29 Acetabular cups placed outside a safe zone of inclination (40 ±10 ) 3 and anteversion (15 ±10 ) 2,3 are associated with higher complication rates. Radiographic measurements of inclination and anteversion are still considered the standard of practice in THA. Estimating the cup angles intraoperatively remains a challenging task, despite surgeon experience and the availability of intraoperative visual cues and aiding guides. 29,30 With advances in computer-assisted surgery, a great opportunity arises to minimize human errors and improve accuracy in performing delicate surgery. In the current study, 88.5% of roboticmeasured inclination and 68.9% of roboticmeasured anteversion were within 5 of radiographic measurements, whereas 96.7% and 98.4% were within 10, respectively (Figure 2A). Bosker et al 31 compared manually estimated intraoperative measurements of cup inclination and anteversion to e34 ORTHOPEDICS Healio.com/Orthopedics
5 postoperative radiographic measurements in 200 cases. Their data showed that 64.5% of radiographic-measured inclination and 61% of radiographic-measured anteversion were within 5 of the angles estimated intraoperatively. The results of the current study demonstrate superior accuracy of the robotic system in estimating cup inclination despite comparable accuracy in estimating cup anteversion, providing the surgeon with a useful tool to improve cup placement. Mean difference between the roboticmeasured and the radiograph-measured angles was 3.2 (range, 0 to 17.5 ) for inclination (P=.006), and 3.8 (range, 0 to 11.3 ) for anteversion (P<.001) (Table 1). Kumar et al 29 compared intraoperative navigation and freehand estimated measurements for inclination and anteversion to postoperative measurements done on CT scans in 56 patients. Their results showed the mean navigation values deviated from the postoperative CT values by 5.3 (range, 1 to 13 ) for inclination and 5.6 (range, 1 to 17 ) for anteversion, and the mean freehand values deviated for the same by 11.4 (range, 1 to 30 ) and 10.8 (range, 2 to 26 ), respectively. These values showed the superior accuracy of navigation in estimating the postoperative CT angles over the conventional technique. The current study s results using the robotic system were superior to those reported by Kumar et al 29 using navigation. However, the current authors used postoperative radiographs in their comparison to robotic measurements, whereas Kumar et al 29 used postoperative CT scans, with added cost and radiation. Leg-length discrepancy is currently one of the most common causes of medical litigation against orthopedic surgeons. 8 Lengthening the operative extremity is sometimes necessary to get a stable hip joint, which is extremely important to prevent postoperative dislocations. 32 Leglength discrepancy of more than 1 cm has been well documented to be associated with adverse short- and long-term outcomes, including nerve palsies, 8,9 abnormal gait, 10 and low back pain. 11 Nerve palsies can be detected in the immediate postoperative period, whereas abnormal gait and low back pain are detected much later in the follow-up period. Mean radiographic postoperative leglength discrepancy in the current study was 2.5 mm (range, -5.8 to 6.8 mm) (Table 2), with 89.8% of measurements at 5 mm or less, and 100% at 10 mm or less (Figure 2B). All patients in the study cohort were within the conventional safe zone of 1 cm for leg-length discrepancy. Mean change in leg length measured on radiographs was 1.6 mm (range, -4.5 to 4.3 mm) (Table 2), with 100% of measurements at 5 mm or less (Figure 2C). No case was lengthened or shortened more than 5 mm. Edwards et al 9 reported on thresholds for nerve damage following lower extremity lengthening, offering thresholds of 27 mm for peroneal nerve damage and 44 mm for femoral nerve damage. In all cases in the current study, leg-length change was lower than these previously mentioned thresholds. Use of the robotic system helped estimate the amount of radiographic leglength change to within 5 mm in 71.4% Table 2 Leg-Length Discrepancy, Leg-Length Change, and Global Offset Change Measurements (N=49) Measurement Mean±SD, mm 95% CI P Leg-length discrepancy Postop radiograph 2.5± Leg-length change Robotic-measured 3.9± Radiographic-measured (preop vs postop) 1.6± <.001 Robotic- vs radiographic-measured 3.5± <.001 Global offset change Robotic-measured 4.3± Radiographic-measured (preop vs postop) 3.4± Robotic- vs radiographic-measured 4.5± Abbreviations: CI, confidence interval; postop, postoperative; preop, preoperative. of the cases and within 10 mm in 100% of cases (Figure 2D). Judging leg-length change intraoperatively using anatomic landmarks and alignment guides is challenging due to the variability in the position of the operated on extremity intraoperatively Keeping leg-length change to a minimum without jeopardizing implant stability is necessary to ensure favorable outcomes in THA. Maintaining an adequate global offset is important for optimal mechanical function of the hip joint. 16 Deviating from an acceptable range of global offset can result in a painful hip and worse outcomes. 16 Decreasing the global offset leads to a decrease in the lever arm working across the hip joint. This decrease leads to a decrease in abductor muscle power, resulting in limping and a Trendelenburg gait. 12,13 Another result of decrease in global offset is an increase in the forces across the articulating surfaces, leading to increased wear. 12,14 However, an increase in global offset results in an increase in the lever arm across the hip joint, which may lead to pain, 15 increased wear, 14 and leg-length discrepancy. 16 Mean global offset change measured on radiographs was 3.4 mm (range, -9.6 to e35
6 11.9 mm) (Table 2), with 73.5% of cases having 5 mm or less of change and 98% having 10 mm or less of change (Figure 2C). Measurement of global offset change was done radiographically on the involved extremity, comparing the postoperative view with the preoperative one. This comparison depends on proper radiographs, which might occasionally be rotated. Sometimes advanced arthritis in the hip with loss of joint space superiorly and medially leads to underestimation of the true native hip offset. Dastane et al 16 reported their global offset change on postoperative radiographs, comparing the operated on with the non-operated on extremity. Mean global offset change in their study was 1.4 mm (range, to 15.3 mm). Keeping offset change within 5 mm is required to maintain proper biomechanics around the hip joint and limit complications. 14,16 In the current study, the robotic system was able to estimate global offset change to within 5 mm of radiographic-measured global offset change in 71.4% of cases and to within 10 mm in 91.8% of cases (Figure 2D). Strengths of this study are that the robotic-measured data were collected prospectively and all cases were performed by a single surgeon using a single approach. The use of 1 type of acetabular implant adds to the strengths of this study. The surgical technique remained the same throughout the series, and planned cup position was the same for all cases (40 for inclination and 20 for anteversion). Both TraumaCad software and the robotic-assisted THA system follow the coronal plane of the pelvis for measurements, making comparison accurate. Furthermore, data measurement on radiographs was done by 2 observers, which allowed for inter- and intraobserver reliability measurements. This study had several limitations. The cases in this cohort are among the first robotic-assisted THA cases performed by the senior surgeon; therefore, these results may reflect the early part of the learning curve for use of this technology. However, due to the current paucity of literature on results of robotic-assisted THA, the authors felt that this early data would be of value to the field. Future studies may concentrate on cases performed after surpassing this learning curve. Femoral anteversion was not studied because the earlier software versions of the robotic system did not allow for femoral anteversion measurements. Measuring femoral anteversion is best done on CT scan, with added expense and radiation exposure. Another limitation was the use of 2 different types of femoral stem implants. The reason is that the smaller sizes of one of the implants was not available, necessitating the use of another stem type to fit into narrow femoral canals. The patient sample size was small, and the current study focuses on radiographic outcomes. Ongoing studies aim to report clinical outcome data follow-up. Conclusion Use of robotic-assisted THA allowed for accurate and reproducible estimation of the postoperative radiographic measurements of cup inclination, cup anteversion, leg-length change, and global offset change. Further studies are needed to relate the radiographic outcomes to the long-term clinical outcomes and costeffectiveness of the robotic-assisted THA system. References 1. Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to J Bone Joint Surg Am. 2007; 89(4): Callanan MC, Jarrett B, Bragdon CR, et al. The John Charnley Award. Risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital. Clin Orthop Relat Res. 2011; 469(2): Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978; 60(2): Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stockl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br. 2005; 87(6): Murphy SB, Ecker TM. Evaluation of a new leg length measurement algorithm in hip arthroplasty. Clin Orthop Relat Res. 2007; 463: Ali Khan MA, Brakenbury PH, Reynolds IS. Dislocation following total hip replacement. J Bone Joint Surg Br. 1981; 63(2): Yamaguchi M, Akisue T, Bauer TW, Hashimoto Y. The spatial location of impingement in total hip arthroplasty. J Arthroplasty. 2000; 15(3): Hofmann AA, Skrzynski MC. Leg-length inequality and nerve palsy in total hip arthroplasty: a lawyer awaits! Orthopedics. 2000; 23(9): Edwards BN, Tullos HS, Noble PC. Contributory factors and etiology of sciatic nerve palsy in total hip arthroplasty. Clin Orthop Relat Res. 1987; (218): Gurney B, Mermier C, Robergs R, Gibson A, Rivero D. Effects of limb-length discrepancy on gait economy and lower-extremity muscle activity in older adults. J Bone Joint Surg Am. 2001; 83(6): Parvizi J, Sharkey PF, Bissett GA, Rothman RH, Hozack WJ. Surgical treatment of limb-length discrepancy following total hip arthroplasty. J Bone Joint Surg Am. 2003; 85(12): Cassidy KA, Noticewala MS, Macaulay W, Lee JH, Geller JA. Effect of femoral offset on pain and function after total hip arthroplasty. J Arthroplasty. 2012; 27(10): McGrory BJ, Morrey BF, Cahalan TD, An KN, Cabanela ME. Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty. J Bone Joint Surg Br. 1995; 77(6): Little NJ, Busch CA, Gallagher JA, Rorabeck CH, Bourne RB. Acetabular polyethylene wear and acetabular inclination and femoral offset. Clin Orthop Relat Res. 2009; 467(11): Incavo SJ, Havener T, Benson E, McGrory BJ, Coughlin KM, Beynnon BD. Efforts to improve cementless femoral stems in THR: 2- to 5-year follow-up of a high-offset femoral stem with distal stem modification (Secur-Fit Plus). J Arthroplasty. 2004; 19(1): Dastane M, Dorr LD, Tarwala R, Wan Z. Hip offset in total hip arthroplasty: quantitative measurement with navigation. Clin Orthop Relat Res. 2011; 469(2): DiGioia AM III, Jaramaz B, Colgan BD. Computer assisted orthopaedic surgery: image guided and robotic assistive technologies. Clin Orthop Relat Res. 1998; 354: Schulz AP, Seide K, Queitsch C, et al. Results of total hip replacement using the Robodoc e36 ORTHOPEDICS Healio.com/Orthopedics
7 surgical assistant system: clinical outcome and evaluation of complications for 97 procedures. Int J Med Robot. 2007; 3(4): Honl M, Dierk O, Gauck C, et al. Comparison of robotic-assisted and manual implantation of a primary total hip replacement: a prospective study. J Bone Joint Surg Am. 2003; 85(8): Parratte S, Argenson JN. Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty: a prospective, randomized, controlled study. J Bone Joint Surg Am. 2007; 89(3): Ybinger T, Kumpan W, Hoffart HE, Muschalik B, Bullmann W, Zweymuller K. Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements: methods and results. J Arthroplasty. 2007; 22(6): Kalteis T, Handel M, Bathis H, Perlick L, Tingart M, Grifka J. Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br. 2006; 88(2): Siebenrock KA, Kalbermatten DF, Ganz R. Effect of pelvic tilt on acetabular retroversion: a study of pelves from cadavers. Clin Orthop Relat Res. 2003; (407): Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993; 75(2): Wan Z, Malik A, Jaramaz B, Chao L, Dorr LD. Imaging and navigation measurement of acetabular component position in THA. Clin Orthop Relat Res. 2009; 467(1): Kumar PG, Kirmani SJ, Humberg H, Kavarthapu V, Li P. Reproducibility and accuracy of templating uncemented THA with digital radiographic and digital TraumaCad templating software. Orthopedics. 2009; 32(11): Steinberg EL, Shasha N, Menahem A, Dekel S. Preoperative planning of total hip replacement using the TraumaCad system. Arch Orthop Trauma Surg. 2010; 130(12): Woo RY, Morrey BF. Dislocations after total hip arthroplasty. J Bone Joint Surg Am. 1982; 64(9): Kumar MA, Shetty MS, Kiran KG, Kini AR. Validation of navigation assisted cup placement in total hip arthroplasty. Int Orthop. 2012; 36(1): Hassan DM, Johnston GH, Dust WN, Watson G, Dolovich AT. Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty. 1998; 13(1): Bosker BH, Verheyen CC, Horstmann WG, Tulp NJ. Poor accuracy of freehand cup positioning during total hip arthroplasty. Arch Orthop Trauma Surg. 2007; 127(5): Clark CR, Huddleston HD, Schoch EP, 3rd, Thomas BJ. Leg-length discrepancy after total hip arthroplasty. J Am Acad Orthop Surg. 2006; 14(1): Bal BS. A technique for comparison of leg lengths during total hip replacement. Am J Orthop (Belle Mead NJ). 1996; 25(1): McGee HM, Scott JH. A simple method of obtaining equal leg length in total hip arthroplasty. Clin Orthop Relat Res. 1985; (194): e37
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology Hips designed to fit the unique anatomies of men and women Independent control for a natural fit Simple, practical solutions for optimal restoration
Product overview and surgical technique
Product overview and surgical technique Overview Every patient moves differently 1 and their total hip replacement should be optimised to account for this. The orientation of the acetabular cup is one
Digital templating facilitates accurate leg length correction in total hip arthroplasty
Acta Orthop. Belg., 2012, 78, 344-349 ORIGINAL STUDY Digital templating facilitates accurate leg length correction in total hip arthroplasty Shivan Sabah JASSIM, Christopher INgHAM, Matthew KEELINg, James
Simplified surgery. Personalized performance.
Simplified surgery. Personalized performance. VISIONAIRE Patient Matched Technology Accuracy Advanced surgical precision, resulting in reproducible outcomes Efficiency Simplifying surgery, reducing costs,
BONE PRESERVATION STEM
TRI-LOCK BONE PRESERVATION STEM Featuring GRIPTION Technology SURGICAL TECHNIQUE IMPLANT GEOMETRY Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was
VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty
VERSYS HERITAGE CDH HIP PROSTHESIS Surgical Technique for CDH Hip Arthroplasty SURGICAL TECHNIQUE FOR VERSYS HERITAGE CDH HIP PROSTHESIS CONTENTS ANATOMICAL CONSIDERATIONS....... 2 PREOPERATIVE PLANNING............
Minimally Invasive Hip Replacement through the Direct Lateral Approach
Surgical Technique INNOVATIONS IN MINIMALLY INVASIVE JOINT SURGERY Minimally Invasive Hip Replacement through the Direct Lateral Approach *smith&nephew Introduction Prosthetic replacement of the hip joint
High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System
High-Flex Solutions for the MIS Era Zimmer Unicompartmental High Flex Knee System Zimmer Unicompartmental High Flex Knee Built On Success In today s health care environment, meeting patient demands means
3D Visualization of Pre-operative Planning for Orthopedic Surgery
SIGRAD 2013, pp. 1 8 T. Ropinski and J. Unger (Editors) 3D Visualization of Pre-operative Planning for Orthopedic Surgery A. Steen 1 and M. Widegren 1 1 Linköpings Universitet, Sweden Abstract This paper
Zimmer M/L Taper Hip Prosthesis. Surgical Technique
Zimmer M/L Taper Hip Prosthesis Surgical Technique Zimmer M/L Taper Hip Prosthesis 1 Zimmer M/L Taper Hip Prosthesis Surgical Technique Table of Contents Preoperative Planning 2 Determination of Leg Length
The goals of surgery in ambulatory children with cerebral
ORIGINAL ARTICLE Changes in Pelvic Rotation After Soft Tissue and Bony Surgery in Ambulatory Children With Cerebral Palsy Robert M. Kay, MD,* Susan Rethlefsen, PT,* Marty Reed, MD, K. Patrick Do, BS,*
Zimmer Gender Solutions NexGen High-Flex Implants
Zimmer Gender Solutions NexGen High-Flex Implants Because Women and Men are Different Something new is taking shape It s all about shape. Women and men are different. That s not news to the medical establishment.
Computer-Assisted Navigation and Musculoskeletal Sarcoma Surgery
Computer navigation systems can assist with presurgical planning and with tumor resections and reconstructions that involve bone-related tumors of the pelvis and extremities. Jeffrey Hessing. Blue Sea
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology Surgical Technique Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology 1 Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology Surgical
The Right Choice. Exeter. total hip system
The Right Choice Exeter total hip system Exeter The Right Choice Anatomic Reconstruction Offset The objectives of total hip replacement are to: relieve pain increase mobility and function Achieving a correct
Influence of leg length discrepancy on clinical results after total hip arthroplasty - A prospective clinical trial
Hip Int 2011; 21 ( 04 ): 441-449 DOI: 10.5301/HIP.2011.8575 ORIGINAL ARTICLE Influence of leg length discrepancy on clinical results after total hip arthroplasty - A prospective clinical trial Christian
MAKOplasty MAKOplasty MAKOplasty MAKOplasty MAKOplasty MAKOplasty MAKOplasty MAKOplasty MAKOplasty
Pre-op Patient Guide to Partial Knee Resurfacing Your Guide to Partial Knee Resurfacing Page I 1 Partial Knee Resurfacing...2 Benefits Possible with the Procedure...4 Your Guide to Surgery...5 Frequently
Computer-Assisted Hip and Knee Arthroplasty. Navigation and Active Robotic Systems
Ontario Health Technology Assessment Series 2004; Vol. 4, No. 2 Computer-Assisted Hip and Knee Arthroplasty. Navigation and Active Robotic Systems An Evidence-Based Analysis February 2004 Medical Advisory
Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y
Y O U R S U R G E O N S choice of implants F O R Y O U R S U R G E R Y Y O U R S U R G E O N S choice of implants F O R Y O U R S U R G E R Y Your Surgeon Has Chosen the C 2 a-taper Acetabular System The
Acetabular Wedge Augment System
Orthopaedics Acetabular Wedge Augment System Stryker Hips. Implant with confidence. Restoration Acetabular Wedge Augment System Restoration Acetabular Wedge Augments, united with Tritanium, Trident, MDM
Total hip arthroplasty (THA) through the anterior approach
Primary Total Hip Arthroplasty with a Minimally Invasive Anterior Approach Jonathan G. Yerasimides, MD, and Joel M. Matta, MD Total hip arthroplasty (THA) through the anterior approach is a minimally invasive
Corporate Medical Policy Computer Assisted Surgical Navigational Orthopedic Procedures
Corporate Medical Policy Computer Assisted Surgical Navigational Orthopedic File Name: Origination: Last CAP Review: Next CAP Review: Last Review: computer_assisted_surgical_navigational_orthopedic_procedures
frequently asked questions Knee and Hip Joint Replacement Technology
frequently asked questions Knee and Hip Joint Replacement Technology frequently asked questions Knee and Hip Joint Replacement Technology Recently, you may have seen advertisements from legal companies
INSTRUCTIONS FOR USING THE KNEE SOCIETY RADIOGRAPHIC EVALUATION FORM
INSTRUCTIONS FOR USING THE KNEE SOCIETY RADIOGRAPHIC EVALUATION FORM Routine standing and recumbent anterior-posterior, lateral, and skyline patellar roentgenograms are made pre-operative, at time of hospital
Failure Mechanisms and Closed Reduction of a Constrained Tripolar Acetabular Liner
The Journal of Arthroplasty Vol. 24 No. 2 2009 Case Report Failure Mechanisms and Closed Reduction of a Constrained Tripolar Acetabular Liner William J. Robertson, MD, Christopher J. Mattern, MD/MBA, John
Total Hip Joint Replacement. A Patient s Guide
Total Hip Joint Replacement A Patient s Guide Don t Let Hip Pain Slow You Down What is a Hip Joint? Your joints are involved in almost every activity you do. Simple movements such as walking, bending,
Clinical performance of endoprosthetic and total hip replacement systems
Veterans Administration Journal of Rehabilitation Research and Development Vol. 24 No. 3 Pages 49 56 Clinical performance of endoprosthetic and total hip replacement systems P. M. SANDBORN, B.S. ; S. D.
Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics
Exeter Orthopaedics V40 Stem Cement-in-Cement Surgical Technique Exeter V40 Stem Cement-in-Cement Surgical Technique Table of Contents Indications and Contraindications...2 Warnings and Precautions...2
Taperloc Complete Hip System
Taperloc Complete Hip System One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical care is to provide
P REPLACEMENT SURGERY
P REPLACEMENT SURGERY DIRECT ANTERIOR APPROACH M I N I M I Z I N G R E C O V E R Y. M A X I M I Z I N G R E S U L T S. CENTER FOR MINIMAL INVASIVE JOINT SURGERY 2301 25TH STREET SOUTH FARGO ND 58103 701-241-9300
KNEE AND HIP SURGICAL ROBOTS MARKET SHARES AND MARKET FORECASTS 13 1. KNEE AND HIP SURGICAL ROBOTS MARKET DESCRIPTION AND MARKET DYNAMICS 22
KNEE AND HIP SURGICAL ROBOTS MARKET SHARES AND MARKET FORECASTS 13 Knee and Hip Surgical Robot Market Driving Forces 13 Knee and Hip Surgical Robot Market Shares 16 Knee and Hip Surgical Robot Forecasts
FEMORAL NECK FRACTURE FOLLOWING TOTAL KNEE REPLACEMENT
1 FEMORAL NECK FRACTURE FOLLOWING TOTAL KNEE REPLACEMENT László Sólyom ( ), András Vajda & József Lakatos Orthopaedic Department, Semmelweis University, Medical Faculty, Budapest, Hungary Correspondence:
Why an Exactech Hip is Right for You
Why an Exactech Hip is Right for You Why do I need a total hip replacement? Which surgical approach is best for me? How long will it last? Which implant is right for me? Founded in 1985 by an orthopaedic
THE MEASUREMENT AND ANALYSIS OF AXIAL DEFORMITY AT THE KNEE
THE MEASUREMENT AND ANALYSIS OF AXIAL DEFORMITY AT THE KNEE Kenneth A. Krackow, M.D. Clinical Director, Department of Orthopaedic Surgery Kaleida Health System Buffalo General Hospital Professor and Full
Treatment of hip dysplasia in children with. Terje Terjesen Department of Orthopaedic Surgery Oslo University Hospital, Rikshospitalet
Treatment of hip dysplasia in children with cerebral palsy Terje Terjesen Department of Orthopaedic Surgery Oslo University Hospital, Rikshospitalet Oslo, Norway Why do CP children have problems in the
Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability
Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability Robert Wetzel, MD, Lalit Puri, MD, S. David Stulberg, MD Disclosure In accordance with ACCME
EMPLOYMENT: PEACHTREE ORTHOPAEDIC CLINIC ATLANTA- GA 2013- PRESENT Orthopaedic Surgeon Northside Hospital, Atlanta, GA
GEORGE N. GUILD III, M.D. ORTHOPAEDIC SURGEON: ADULT HIP AND KNEE RECONSTRUCTION PEACHTREE ORTHOPAEDIC CLINIC 5505 PEACHTREE DUNWOODY ROAD SUITE 600 ATLANTA, GA 30342 TEL. (404)- 355-0743 FAX: 404-355-
Malrotation Causing Patellofemoral Complications After Total Knee Arthroplasty
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH Number 356, pp 144-153 1998 Lippincott Williams 8 Wilkins Malrotation Causing Patellofemoral Complications After Total Knee Arthroplasty R.A. Berger, MD *; L.S.
Hip Resurfacing 2011 ORIGINAL ARTICLE. James W. Pritchett MD. Introduction. Abstract
1 ORIGINAL ARTICLE Hip Resurfacing 2011 James W. Pritchett MD Abstract In 1938 Marion Smith-Peterson placed a cobalt chromium cup on a reshaped femoral head to perform the first hip resurfacing. 15 Also,
Robotic-Arm Assisted Surgery
Mako TM Robotic-Arm Assisted Surgery for Total Hip Replacement A Patient s Guide Causes of Your Hip Pain Your joints are involved in almost every activity you do. Movements such as walking, bending and
Custom Design of Knee Joint Prosthesis By Using Computerized Tomography (CT) Images and 3D Modelling
Custom Design of Knee Joint Prosthesis By Using Computerized Tomography (CT) Images and 3D Modelling Qasem Alyazji Near East University, Department of Biomedical Engineering Nicosia, North Cyprus, Turkey
Structure and Function of the Hip
Structure and Function of the Hip Objectives Identify the bones and bony landmarks of the hip and pelvis Identify and describe the supporting structures of the hip joint Describe the kinematics of the
Kaiser Permanente. National Total Joint Replacement Registry. Liz Paxton Director of Surgical Outcomes & Analysis
Kaiser Permanente National Total Joint Replacement Registry Liz Paxton Director of Surgical Outcomes & Analysis Overview Background Total Joint Replacement (TJR) Importance of establishing a TJR post-market
Clinically Proven Fiber Metal Material. Power to choose advanced bearing technologies to match patient demands
Trilogy IT Acetabular System Design Rationale 1 For orthopedic surgeons treating a wide range of patients, the Trilogy IT Acetabular System provides a clinically proven1-5 Fiber Metal Material and the
Oftentimes, as implant surgeons, we are
CLINICAL AVOIDING INJURY TO THE INFERIOR ALVEOLAR NERVE BY ROUTINE USE OF INTRAOPERATIVE RADIOGRAPHS DURING IMPLANT PLACEMENT Jeffrey Burstein, DDS, MD; Chris Mastin, DMD; Bach Le, DDS, MD Injury to the
Complex Primary to Revision Hip Arthroplasty
HIP SOLUTIONS Complex Primary to Revision Hip Arthroplasty Programme Chairperson: Dr. Philip J Roberts (UK), Faculty: Prof. Burak Beksaç (Turkey), Assoc. Prof. Ali Al Blooshi, (UAE), Assoc. Prof. Afshin
DIAGNOSING SCAPHOID FRACTURES. Anthony Hewitt
DIAGNOSING SCAPHOID FRACTURES Anthony Hewitt Introduction Anatomy of the scaphoid Resembles a deformed peanut Articular cartilage covers 80% of the surface It rests in a plane 45 degrees to the longitudinal
Hamstring Apophyseal Injuries in Adolescent Athletes
Hamstring Apophyseal Injuries in Adolescent Athletes Kyle Nagle, MD MPH University of Colorado Department of Orthopedics Children s Hospital Colorado Orthopedics Institute June 14, 2014 Disclosures I have
ReCap Product Rationale
FLH 155 01/09 Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom Tel. +44 (0)1656 655221 Fax. +44 (0)1656 645454 ReCap Product Rationale A complete resurfacing system
Clinical and Radiographic Outcomes of 139 Hips with Articular Surface Replacement Total Hip Arthroplasty*
Clinical and Radiographic Outcomes of 139 Hips with Articular Surface Replacement Total Hip Arthroplasty* Assaf Kadar MD 1, Ran Ankory MD 1, Haggay Sherman MD 1, Iris Eshed MD 2, adav Shasha MD 1, Aviram
An Alternative Conservative Approach to Hip Reconstruction
Joint Implant Surgery & Research Foundation Chagrin Falls, Ohio, USA An Alternative Conservative Approach to Hip Reconstruction Craig S. Waller, MD* and Timothy McTighe, Dr. H.S. (hc)** Acknow ledgement:
Understanding Total Hip Replacement
Understanding Total Hip Replacement Brian J. White MD Orthopaedic Specialist in Disorders of the Hip Assistant Team Physician Denver Nuggets Western Orthopaedics Denver, Colorado Introduction This is designed
AN AUTOMATED SIZE RECOGNITION TECHNIQUE FOR ACETABULAR IMPLANT IN TOTAL HIP REPLACEMENT
AN AUTOMATED SIZE RECOGNITION TECHNIQUE FOR ACETABULAR IMPLANT IN TOTAL HIP REPLACEMENT A. Shapi i 1, R. Sulaiman 2, M.K. Hasan 3 and A.Y.M. Kassim 4 1 Industrial Computing Research Group, Universiti Kebangsaan
Metasul LDH Large Diameter Head
Metasul LDH Large Diameter Head Surgical Technique Metasul LDH Large Diameter Head Surgical Technique Enhancing Stability and Increasing Range of Motion Metasul LDH Large Diameter Head Surgical Technique
Introduction to the Bertram Hip Spacer
Introduction to the Bertram Hip Spacer Approximately 200,000 hip replacement surgeries are done every year in United States. Fortunately the incidence of infection is routinely 0.5 percent-1 percent. However
When is Hip Arthroscopy recommended?
HIP ARTHROSCOPY Hip arthroscopy is a minimally invasive surgical procedure that uses a camera inserted through very small incisions to examine and treat problems in the hip joint. The camera displays pictures
Robotics. Neil Badlani MD, MBA The Orthopedic Sports Clinic Nobilis Health Corp. Houston, TX. The Orthopedic Sports Clinic
Robotics Neil Badlani MD, MBA The Orthopedic Sports Clinic Nobilis Health Corp. Houston, TX The Orthopedic Sports Clinic Disclosure Consulting/Speaking Medtronic Amendia Nutech Mazor * MIS Device Outline
Has Digital Templating Become the Standard of Care in Orthopaedics? An Interview with 5 Orthopaedic Surgeons
Has Digital Templating Become the Standard of Care in Orthopaedics? An Interview with 5 Orthopaedic Surgeons Introduction Many orthopaedic surgeons in North America have either already made the transition
Disclosures. ! Consultant. ! Stryker. ! Smith and Nephew. Why Resurface? ! Save bone the day of surgery. ! No bone loss from stressshielding
Disclosures irmingham Hip Resurfacing Hip Resurfacing in 2015 Peter rooks MD, FRCS(C) Cleveland Clinic! Consultant! Stryker! Smith and Nephew HR Goals Why Resurface? Why Resurface?! Summarize benefits!
NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal
NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE Health Technology Appraisal Total hip replacement and resurfacing arthroplasty for the treatment of pain or disability resulting from end stage arthritis
Anterior Hip Replacement
Disclaimer This movie is an educational resource only and should not be used to manage Orthopaedic health. All decisions about the management of hip replacement and arthritis management must be made in
Hip Replacement Surgery Understanding the Risks
Hip Replacement Surgery Understanding the Risks Understanding the Risks of Hip Replacement Surgery Introduction This booklet is designed to help your doctor talk to you about the most common risks you
Hip and Knee Orthopedic Surgical Robots: Market Shares, Strategies, and Forecasts, Worldwide, 2016-2022
Brochure More information from http://www.researchandmarkets.com/reports/3608083/ Hip and Knee Orthopedic Surgical Robots: Market Shares, Strategies, and Forecasts, Worldwide, 2016-2022 Description: Worldwide
From Department of Orthopaedics, Conquest Hospital, The Ridge, East Sussex. n N.A. Sandiford, FRCS (Tr/Orth), MFSEM, Specialist. Registrar.
Acta Orthop. Belg., 2014, 80, 372-379 ORIGINAL STUDY Primary total hip arthroplasty with hydroxyapatite coated titanium femoral stems. Does design philosophy influence long term outcome? : results of a
Joint Revision Surgery - When Do I Need It?
Page 1 of 7 Joint Revision Surgery - When Do I Need It? Joint replacement surgery is undoubtedly one of the greatest medical advances of our time. Hip and knee replacements have been performed in millions
The goals of modern spinal surgery are to maximize
SPRING 2013 Robot-Guided Spine Surgery Christopher R. Good, M.D., F.A.C.S. and Blair K. Snyder, P.A.-C. The goals of modern spinal surgery are to maximize patient function and accelerate a return to a
for Image Scaling Enabling Digital Orthopaedics
Calibration Devices, Use & Positioning for Image Scaling Enabling Digital Orthopaedics DIGITAL IMAGE SCALING As Radiology becomes filmless. Current planning practices used by surgeons with acetate sheets
Evaluate the hindfoot alignment after total knee arthroplasty; new radiographic view of the hindfoot.
Evaluate the hindfoot alignment after total knee arthroplasty; new radiographic view of the hindfoot. Yusuke Hara, Kazuya Ikoma, Yuji Arai, Koji Nagasawa, Suzuyo Ohashi, Kan Imai, Masamitsu Kido, Toshikazu
MIS Direct Anterior Approach Surgical Protocol
Joint Replacements MIS Direct Anterior Approach Surgical Protocol The Right Procedure and the Right Implant for the Right Patient Scientific advice and text: Franz Rachbauer, M.D., M.A.S., M.Sc. Associate
Total Hip Replacement
Please contactmethroughthegoldcoasthospitaswityouhaveanyproblemsafteryoursurgery. Dr. Benjamin Hewitt Orthopaedic Surgeon Total Hip Replacement The hip joint is a ball and socket joint that connects the
TOTAL HIP REPLACEMENT: MODERN SURGERY FOR SEVERE ARTHRITIS OF THE HIP
TOTAL HIP REPLACEMENT: MODERN SURGERY FOR SEVERE ARTHRITIS OF THE HIP John T. Dearborn, M.D. and Alexander P. Sah, M.D. The Center for Joint Replacement Please read this pamphlet before you see me so that
Luigi Vito Stefanelli,D.Eng.,DDS
LYON, 27-28/09/2013 Luigi Vito Stefanelli,D.Eng.,DDS Assistant Researcher, Department of Oral Sciences, Sapienza University of Rome, Italy, School of Dentistry. Private practitioner dental office Stasi
St. Charles Hospital Orthopedic Specialists Invent and Refine Surgical Techniques
St. Charles Hospital Orthopedic Specialists Invent and Refine Surgical Techniques By: Jennifer Webster Tuesday, October 01, 2013 It s one thing to practice advanced surgery. But St. Charles Hospital takes
PERIPROSTHETIC IMPLANTS
PERIPROSTHETIC IMPLANTS PRODUCT OVERVIEW CLINICAL SOLUTIONS Periprosthetic fractures present unique challenges, such as how to gain fixation when the medullary canal is occupied. Special techniques and
2007 James A Vohs Award for Quality Multiregion The Kaiser Permanente National Total Joint Replacement Registry
available online: www.kp.org/permanentejournal Original article 2007 James A Vohs Award for Quality Multiregion The Kaiser Permanente National Total Joint Replacement Registry Elizabeth W Paxton, MA Maria
Posttraumatic medial ankle instability
Posttraumatic medial ankle instability Alexej Barg, Markus Knupp, Beat Hintermann Orthopaedic Department University Hospital of Basel, Switzerland Clinic of Orthopaedic Surgery, Kantonsspital Baselland
on-metal Hips: Device Mechanics and Failure Modes
1 Metal-on on-metal Hips: Device Mechanics and Failure Modes Steven M. Kurtz, Ph.D., and Richard Underwood, Ph.D. Exponent, Inc., and Drexel University NIH R01 AR47904 2 Contracts: DePuy Orthopaedics,
Screening Examination of the Lower Extremities BUY THIS BOOK! Lower Extremity Screening Exam
Screening Examination of the Lower Extremities Melvyn Harrington, MD Department of Orthopaedic Surgery & Rehabilitation Loyola University Medical Center BUY THIS BOOK! Essentials of Musculoskeletal Care
Graphic courtesy of DePuy Orthopaedics, Inc. HealthEast Joint Replacement Registry: 20 Year Report
Graphic courtesy of DePuy Orthopaedics, Inc. HealthEast Joint Replacement Registry: 20 Year Report HealthEast Joint Replacement Registry: 20 Year Report Foreword HealthEast Care System began the first
Syndesmosis Injuries
Syndesmosis Injuries Dr. Alex Rabinovich Outline Anatomy Injury types and classification Treatment options Nonoperative vs. Operative Indications for operative Operative technique Postoperative management
MN Community Measurement Total Knee Replacement Impact and Recommendation Document June 2010
MN Community Measurement Total Knee Replacement Impact and Recommendation Document June 2010 Degree of Impact Relevance to Consumers, Employers and Payers Annually there are over 500,000 total knee replacement
PRESENTATIONS/PAPERS INTERNATIONAL. RAISING STANDARDS IN JOINT ARTHROPLASTY Course Co-Chairman, The Great Debate - London, June 2013
PRESENTATIONS/PAPERS INTERNATIONAL 1998 2013 RAISING STANDARDS IN JOINT ARTHROPLASTY Course Co-Chairman, The Great Debate - London, June 2013 HOW TO CHOOSE THE RIGHT STEM FOR THE RIGHT PATIENT Corin Symposium
Chamnanni Rungprai, M.D.
Outcomes of single versus multi-level Gastrosoleus or Achilles tendon lengthening Techniques: A Comparative Study 1,2 Chamnanni Rungprai, M.D. Co-authors 1 Christopher Cyclosz, M.D. 1 Phinit Phisitkul,
Features and Benefits at a Glance Standard Features ExclusiveTable Maneuverability Superior Imaging High Stability Ordering Information
Introducing the biggest surgical instrument in orthopedic surgery. a new level A TABLE THAT PERFORMS LIKE A MINIMA PROfx ELEVATES THE SURGICAL TABLE TO A NEW LEVEL FO "THE PERFECT FRACTURE TABLE" The PROfx
What Is Femoral Acetabular Impingement? Patient Guide into Joint Preservation
What Is Femoral Acetabular Impingement? Patient Guide into Joint Preservation Normal Hip Joint The hip joint, also known as a ball and socket joint is located where the femur (the thigh bone) meets the
Cup positioning in total hip arthroplasty
Acta Orthop. Belg., 2014, 80, 336-347 ASPECTS OF CURRENT MANAGEMENT Cup positioning in total hip arthroplasty Thierry Scheerlinck From the Universitair Ziekenhuis Brussel (UZ Brussel), Belgium The optimal
How To Fix A Radial Head Plate
Mayo Clinic CoNGRUENT RADIAL HEAD PLATE Since 1988 Acumed has been designing solutions to the demanding situations facing orthopedic surgeons, hospitals and their patients. Our strategy has been to know
PINNACLE. Polyethylene Surgical Technique. Surgical Technique
PINNACLE Hip Solutions Polyethylene Surgical Technique Surgical Technique Table of Contents Surgical technique Introduction 4 Templating and Pre-Operative Planning 6 Surgical Approach Anterolateral 8
VEGA System. PS Knee Replacement Technology. Aesculap Orthopaedics
VEGA System PS Knee Replacement Technology Aesculap Orthopaedics A pivotal breakthrough in knee replacement. VEGA System PS Knee Replacement Technology Based on a patent-pending post-cam design that optimizes
Metal-on-Metal Hip Systems
Meeting of the Orthopaedic and Rehabilitation Devices Advisory Panel June 27-28, 2012 Metal-on-Metal Hip Systems Center for Devices and Radiological Health U.S. Food and Drug Administration Meeting of
Imaging of Lisfranc Injury
November 2011 Imaging of Lisfranc Injury Greg Cvetanovich, Harvard Medical School Year IV Agenda Case Presentation Introduction Anatomy Lisfranc Injury Classification Imaging Treatment 2 Case Presentation
Total Knee Replacement Specifications 2014 (01/01/2012 to 12/31/2012 Dates of Procedure)
Summary of Changes Removed following ICD-9 Procedure s: 81.54 Total Knee Replacement (Bicompartmental, Partial Knee Replacement, Tricompartmental, Unicompartmental (hemijoint)). 81.55 Revision of Knee
Aesculap Orthopaedics Metha
Aesculap Orthopaedics Metha Short Hip Stem Evolving the State of Arthroplasty 2 Evolving the State of Arthroplasty Contents Short Hip Stem System 4 Short Stem Anchoring Concept 6 Variable Implant Options