OP01 FLICKER (PSTLM) AND STROBOSCOPIC EFFECT (SVM) LIGHT MEASUREMENTS IN PHOTOMETRICAL LABORATORIES. SIGNIFY DEVELOPED SETUP AND VALIDATION METHOD

Similar documents
Data Communications Competence Center

Application/ Requirements for LED Lighting Products Certification Scheme

OVERVIEW AUTOMATION SERVICES

Flicker happens. But does it have to?

Standards & Specifications Update: Dimming & Flicker

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Uncertainty evaluations in EMC measurements

IEC and CISPR Standards

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

Check-list for auditors. Audit visit at candidate registered laboratories

Designing Gain and Offset in Thirty Seconds

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

Frequency Response of Filters

International Commission on Illumination

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

SignalPad Data Logging and Analysis Software

Visual System Simulator White Paper

The Latest in LED Lighting Test Methods and Standards. Jianzhong Jiao, Ph.D. OSRAM Opto Semiconductors Inc.

A Network Analyzer For Active Components

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

EXPERIMENTAL ERROR AND DATA ANALYSIS

Avalanche Photodiodes: A User's Guide

USB2.0 Technical Manual

Op-Amp Simulation EE/CS 5720/6720. Read Chapter 5 in Johns & Martin before you begin this assignment.

Understanding Mixers Terms Defined, and Measuring Performance

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

Duobinary Modulation For Optical Systems

Apples & Pears, a CELMA guiding paper: Why standardisation of performance criteria for LED luminaires is important

REQUIREMENTS FOR AUTOMATED FAULT AND DISTURBANCE DATA ANALYSIS

What Does Rail-to-Rail Operation Really Mean?

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

Verifying the IEC Configuration and Assessing the Communication Network during Commissioning

Creating a Usable Power Supply from a Solar Panel

Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July Reprinted from Photonics Spectra, Laurin Publishing

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Information Architecture Planning Template for Health, Safety, and Environmental Organizations

Experiment 5. Lasers and laser mode structure

Introduction to FM-Stereo-RDS Modulation

Final Report. Hybrid Synth by Synthesize Me. Members: Jamie Madaris Jack Nanney

CBS RECORDS PROFESSIONAL SERIES CBS RECORDS CD-1 STANDARD TEST DISC

Assessments of LEDs IESNA LM-79, LM-80 & LM-82

30 In Compliance October

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Depth and Excluded Courses

Radiated emission measurement of a cell phone processor module using TEM cell

Nederland België / Belgique

September 9, Section 1: Purpose of this Document & Timeline for Implementation

Taking the Mystery out of the Infamous Formula, "SNR = 6.02N dB," and Why You Should Care. by Walt Kester

Why test results can t compare

Simulation and Design of Printed Circuit Boards Utilizing Novel Embedded Capacitance Material

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

School of Engineering Department of Electrical and Computer Engineering

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

Influence of the Socket on Chip-level ESD Testing

Universidad de Alcalá

Cond-IS RF Conducted Immunity System

Everything you need for protection scheme testing

1 Coffee cooling : Part B : automated data acquisition

See Horenstein 4.3 and 4.4

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Radiography: 2D and 3D Metrics of Performance Towards Quality Index

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Teseq ESD Simulator Verification

TDMS Test & Data Management Software

Optimizing Inventory Management at SABIC

EMC TEST REPORT For. Webcam. Model Number: CAM67U

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

ELECTRON SPIN RESONANCE Last Revised: July 2007

IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz

ÖNORM EN Valve proving systems for automatic shut-off valves for gas burners and gas appliances

APPENDIX N. Data Validation Using Data Descriptors

NIST HANDBOOK CHECKLIST CONSTRUCTION MATERIALS TESTING

Correlation between OATS, Fully Anechoic Room and GTEM Radiated Emissions

Introduction to Functional Verification. Niels Burkhardt

Progettare per il Solid State Lighting: le sfide da superare

A Guide to the Specification of LED Lighting Products 2012

What methods are used to conduct testing?

TCOM 370 NOTES 99-4 BANDWIDTH, FREQUENCY RESPONSE, AND CAPACITY OF COMMUNICATION LINKS

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

TRU Math Conversation Guide

Development of an Electrical Power Quality Monitor Based on a PC

Understanding the Effect of Uncorrelated Phase Noise on Multi-channel RF Vector Signal Generators and Analysers

ELECTRICAL ENGINEERING

INTERNATIONAL STANDARD

Active noise control in practice: transformer station

Analysis of Immunity by RF Wireless Communication Signals

INTERNATIONAL STANDARD

PWM-60 series IP67 TRC ELECTRONICS, INC

EE4367 Telecom. Switching & Transmission. Prof. Murat Torlak

Data Acquisition Using NI-DAQmx

Validation and Calibration. Definitions and Terminology

(3 )Three Phase Alternating Voltage and Current

Experiment # (4) AM Demodulator

Power Quality Centre VOLTAGE FLUCTUATIONS IN THE ELECTRIC SUPPLY SYSTEM. Technical Note No. 7 August 2003

Transcription:

OP01 FLICKER (PSTLM) AND STROBOSCOPIC EFFECT (SVM) LIGHT MEASUREMENTS IN PHOTOMETRICAL LABORATORIES. SIGNIFY DEVELOPED SETUP AND VALIDATION METHOD Adam Klej et al. DOI 10.25039/x46.2019.OP01 from CIE x046:2019 Proceedings of the 29th CIE SESSION Washington D.C., USA, June 14 22, 2019 (DOI 10.25039/x46.2019) The paper has been presented at the 29th CIE Session, Washington D.C., USA, June 14-22, 2019. It has not been peer-reviewed by CIE. CIE 2019 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from CIE Central Bureau at the address below. Any mention of organizations or products does not imply endorsement by the CIE. This paper is made available open access for individual use. However, in all other cases all rights are reserved unless explicit permission is sought from and given by the CIE. CIE Central Bureau Babenbergerstrasse 9 A-1010 Vienna Austria Tel.: +43 1 714 3187 e-mail: ciecb@cie.co.at www.cie.co.at

FLICKER (PST LM ) AND STROBOSCOPIC EFFECT (SVM) LIGHT MEASUREMENTS IN PHOTOMETRICAL LABORATORIES. SIGNIFY DEVELOPED SETUP AND VALIDATION METHOD Adam Klej 1, Andrew Jackson 2, Pierre Beeckman 1, Norbert Mila 3, Konika Banerjee 1, Marc Embrechts 4, Henk-Jan van Aalderen 1 1 Signify, Eindhoven, NETHERLANDS, 2 Signify, Salina, USA, 3 Signify, Shanghai, CHINA, 4 Signify, Turnhout, BELGIUM Abstract 1 Motivation, specific objective adam.klej@signify.com DOI 10.25039/x46.2019.OP01 The document CIE TN 006:2016 - Visual Aspects of Time-Modulated Lighting Systems Definitions and Measurement Models contains the description of current measures to evaluate Temporal Light Artifacts (TLA), including flicker and stroboscopic effects. From an industry perspective, there are several methods available to record optical waveforms and to evaluate these waveforms for TLA effects. These TLA metrics can be utilized to judge the quality of lighting products. The primary documents that are currently available for test and measurement of optical waveforms and TLA are: [1] National Electrical Manufacturers Association (NEMA) NEMA 77-2017 Temporal Light Artifacts: Test Methods and Guidance; [2] International Electrotechnical Commission (IEC) TR 61547-1:2017 ED2 Equipment for general lighting purposes - EMC immunity requirements - Part 1: An objective light flickermeter and voltage fluctuation immunity test method; and [3] (IEC) TR 63158:2018 Equipment for general lighting purposes - Objective test method for stroboscopic effects of lighting equipment. These three documents provide guidance for performing accurate measurements, but many laboratories struggle making consistent and accurate measurements of temporal light artefacts. Keywords: Photometry, TLA, stroboscopic effect, flicker effect, Pst LM, SVM, TLM 2 Methods Signify developed a measurement setup and verification methods for TLA, utilizing a novel reference modulation radiator (aka Reference Radiator) to validate the TLA measurement systems. 2.1 TLA Acquisition setup The test set-up utilized in Signify follow the approach outlined in NEMA-77 and in the IEC documents and [1,2,3] and a block-diagram of the setup is presented in Figure 1. Figure 1 Signify TLA Acquisition setup scheme Proceedings of 29th CIE Session 2019 3

The measurement Setup contains: Power Supply Photodiode with Eye response curve Trans-Impendence Amplifier 1 ST Order Low Pass filter Voltage Capture Device Acquisition Software developed by Signify 2.2 Signify TLA Reference Radiator Proper verification of the TLA setup can be challenging due to novelty of measurement methods and often not knowing the limitations of TLA acquisition setups that may cause wrong measurements of TLA. The Signify TLA Reference Radiator (Figure 2) can be used to evaluate the measurement abilities of the setup. The radiator generates pre-programmed periodic light waveforms with different shapes, modulation frequencies & modulation levels. The exact values of the TLA metrics (Pst LM, SVM, FI, MD) are known for the input waveforms (mathematical representations) and it can generate very stable and reproducible optical signals. The unit is used to: Demonstrate TLA effects (education) Examine the appropriateness of existing metrics Validate TLA test set-ups Provide a controlled round robin sample for interlaboratory comparison there are more than 26 optical waveshapes that have been programmed into the unit And may be used to test metric limits (research) Figure 2 Signify Reference Radiator - Description Figure 3 shows example Ideal vs. measured sawtooth waveform #9 which has a modulation depth of 100 % and a frequency of 50 Hz. The graph shows a good linear relationship between applied LED current waveform and actual measured light waveform. 4 Proceedings of 29th CIE Session 2019

3 Results Figure 3 Example waveform #9 analytical (ideal) and measured waveforms For the verification of the Reference Radiator, the mathematically calculated values were compared with the measured values. Graph (Figure 4) shows a good correlation for Pst LM and SVM between measured and numerical/analytical values of the waveforms. 100.000 PstLM measured vs. reference values 8.000 SVM measured vs. reference values 80.000 6.000 y = 0.99x R² = 1.00 PstLM measured 60.000 40.000 y = 1.00x R² = 1.00 SVM measured 4.000 2.000 20.000 0.000 0.000 20.000 40.000 60.000 80.000 100.000 PstLM reference (numerical) 0.000 0.000 2.000 4.000 6.000 8.000 SVM reference (analytical) Figure 4 Pst LM and SVM measured values vs reference values Additionally, the reference radiator was utilized to carry out an interlaboratory comparison between three light measurement laboratories. Several pre-programmed waveforms of which the TLA metrics were known analytically were chosen for the comparison. The TLA measurement capabilities as well as the limitations of the laboratories were examined. The proper acquisition of the light waveforms and the proper data processing and calculation of the metrics were the main points of attention of this study. Proceedings of 29th CIE Session 2019 5

4 Conclusions A proper verification of the TLA measurement system and, knowing its limitation is important to ensure high quality measurements at Photometrical Laboratories. The verification method developed by Signify using the reference radiator provides a solution to laboratories to have the ability to measure and calculate quantities correctly. Interlaboratory comparison results show alignment between laboratories where the reference radiator was utilized for verification of the set-up. The first two NVLAP accredited laboratories to the NEMA 77-2017 standard were Signify Laboratories Salina/USA and Shanghai/China. This proves that Signify verification method helps reach ability and reproducibility of measured quantities at the developed setups. Signify experts are also involved in Division 2 TC2-89 activities on TLA/TLM Measurements Technical Note, which is guidance document for Photometrical Laboratories to enable proper measurements. More details on Reference Radiator abilities and results of comparison of results between Signify Lighting Test Centers will be presented during the oral presentation at CIE conference. References [1] National Electrical Manufacturers Association (NEMA) NEMA 77-2017 Temporal Light Artifacts: Test Methods and Guidance; [2] International Electrotechnical Commission (IEC) TR 61547-1:2017 ED2 Equipment for general lighting purposes - EMC immunity requirements - Part 1: An objective light flickermeter and voltage fluctuation immunity test method; and [3] International Electrotechnical Commission (IEC) TR 63158:2018 Equipment for general lighting purposes - Objective test method for stroboscopic effects of lighting equipment. 6 Proceedings of 29th CIE Session 2019