Risk Assessment: Biosafety Cabinet



Similar documents
Procedures for the Effective Use of Biological Safety Cabinets

Biosafety Level 2 (BSL-2) Safety Guidelines

PI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3)

The following standard practices, safety equipment, and facility requirements apply to BSL-1:

BIOLOGICAL SAFETY CABINET PROGRAM

Laboratory Biosafety Level 3 Criteria

Biosafety Level 2 Criteria

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

UNIVERSITY OF NEVADA LAS VEGAS BSL-3 LABORATORY STANDARD OPERATING PROCEDURES (SOPS)

Microbiology Lab Practices and Safety Rules

Response to Biological Spills in the Laboratory (Intentional or Accidental)

Lab Biosafety Level 3 Checklist (dates: April 16, 1998)

Required Biosafety Level Three (BSL-3) Practices, Procedures, Facilities, and Safety Equipment For BSL-3 and BSL3/2 Laboratories

Laboratory Biosafety Manual Contents

A Guide to Biosafety & Biological Safety Cabinets

Appendix J IBC Biohazard Spill Management Plan

Office of Health and Safety (OHS) BMBL Appendix I

Carnegie Mellon University. Institutional Biological Safety Committee SAFETY PLAN FOR THE USE OF BIOLOGICAL MATERIALS AND ASSOCIATED DEVICES

CDC Import Permit Inspection Checklist for ABSL-3 Laboratories (BMBL 5th Edition)

How To Manage A Bsl 4 Laboratory

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Laboratory Design & Construction Guidelines

THE UNIVERSITY OF NEWCASTLE- SCHOOL of BIOMEDICAL SCIENCES

Biological Safety Program

Biosafety Program University of Colorado. BSL-1 Audit Checklist

The following standard practices, safety equipment, and facility requirements apply to BSL-1:

Date Last Revised: 3/08 Number of Pages: 69 BIOSAFETY PROGRAM. Section 2. Applicable Regulatory Requirements and Guidelines

STANDARD OPERATING PROCEDURES SPILL RESPONSE AND CLEAN-UP OUTSIDE BIOSAFETY CABINET

Biosafety Guidelines. 5. Pipetting Mechanical pipetting devices must be available and used. Mouth pipetting is prohibited.

Appendix A Primary Containment for Biohazards: Selection, Installation and Use of Biological Safety Cabinets

Fume Hood Questions and Answers

Section III Principles of Biosafety

Carnegie Mellon University s Policy and Procedures for Recombinant and Synthetic Nucleic Acid Materials Spills

Biosafety Spill Response Guide

Biosafety in the Mycobacteriology Laboratory

Texas Tech University Standard Operating Procedures Manual. Biosafety Level 2 Laboratory. of Dr. Boyd Butler

Policies. Prep Room Policies

BSL 1 Laboratory Biosafety Manual

Chemical Fume Hoods. Environmental Health and Safety

BOSTON COLLEGE ENVIRONMENTAL HEALTH AND SAFETY LABORATORY GUIDE FOR RENOVATIONS, REMODELS, MOVES AND TERMINATIONS

Scott & White Institutional Biosafety Committee Compliance Program Biohazardous Material Spill Clean-Up Procedure Policy #IBC.002

Laboratory Biosafty In Molecular Biology and its levels

Department of Environmental Health and Safety & Emergency Management

Knowledge and Awareness of Proper Waste Disposal and Routine Biosafety Measures Among HealthCare Workers in Karachi, Pakistan (JUW-BEP-BSAP Project)

Biological Safety Cabinet Management Program

Bill Mixon, RPh, MS Senior Associate Gates Healthcare Associates

UNH SAFETY AUDIT Office of Environmental Health and Safety

DNA Analyst Training Laboratory Training Manual Protocol 2.02 Clean Technique

Laboratory Biosafety Plan Template. For Biosafety Level 1 and 2

Recommendations for the Safe Use of Handling of Cytotoxic Drugs

Dr Ali A. Mohammadi President Global Health and Security Consultants. 18/3/2013 Global Health & Security Consultants

Standard Operating Procedure for Dacarbazine in Animals

GUIDELINES FOR HANDLING PATHOGENIC MICROORGANISMS AND DISPOSING BIOHAZARDOUS WASTE. Biohazard Recognition and Control

Decontamination and Waste Management

PRINCIPAL INVESTIGATOR REGISTRATION FOR SELECT AGENTS

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

Shop Safety. Action Tattoo 3525 Del Mar Heights Rd., Suite 7 San Diego, CA 92130

Laboratory Ventilation Safety. J. Scott Ward

Biohazard and Biosafety

Blood Borne Pathogen Exposure Control Plan Checklist

Safe Operating Procedure

Questions & Answers (Q & A) Regarding Asbestos Treatment with the Fire Suppression and Renovation Project

Laboratory Safety Inspection Checklist (Biology and Biochemistry)

Laminar Flow Cabinets and Workstations

Water should be removed as soon as possible once the safety of the structure has been verified.

Laboratory Safety: Work Practices for Mycobacterium tuberculosis

PROJECT HAZARD ASSESSMENT FORM CHEMICAL HAZARDS

Minimizing Occupational Exposure to Hazardous Chemicals in Animal Protocols

Biological Safety Manual

Decommissioning and clearance of laboratories

Section 4 EMERGENCY EYEWASH AND SAFETY SHOWER EQUIPMENT

SAFE USE OF MICROBIOLOGICAL SAFETY CABINETS

IX. Decontamination and Spills

Fumigation of Safety Cabinets

CHAPTER V: DISPOSAL OF WASTES CONTAMINATED WITH INFECTIOUS AGENTS

OESO Ergonomics Division ERGO(3746) Duke Police Corporate Risk Management

Waste Management Log Book

Public Health Laboratory Services Branch Centre for Health Protection, Department of Health Hong Kong Special Administrative Region

Biosafety Level One/Two (BSL-1/2) Inspection Checklist

COMPREHESIVE LAB SAFETY CHECKLIST

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Particularly Hazardous Substances (PHS) Standard Operating Procedure (SOP)

Best Practices for Handling Nanomaterials in Laboratories

Sample Pharmacy CLEANING AND SANITIZING PROCEDURE P-304.1

Lab Safety and Standard Operating Procedures. Faculty of Dentistry And School of Biomedical Engineering

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Laboratory Audit Sheet Auditor s Name: Date of Inspection: / / Building Name: Room# Principal Investigator:

CHEMICAL SPILL MANAGEMENT GUIDELINES

SPILL RESPONSE PROCEDURE

INFECTION CONTROL POLICY MANUAL

Archived. Gloves should be changed frequently during the analysis.

Hazardous Drugs Compounded by a Prescriber.

Beware that ordinary prescription glasses do not provide adequate protection. This is also true with poorly fitting safety glasses.

Edith Cowan University Faculty of Health, Engineering and Science Work Health and Safety Committee

Laboratory Safety and Environmental Health Assessment Program

Bloodborne Pathogens Program Revised July,

Transcription:

Risk Assessment: Biosafety Cabinet Biosafety cabinets (BSCs) serve as primary containment devices for operations involving potential splashes, spills or aerosolization of hazardous biological materials. They are designed to provide personnel, environmental and product protection when appropriate practices and procedures are followed. Three kinds of biosafety cabinets, designated as Class I, II and III, have been developed to meet varying research and clinical needs. They can effectively contain and capture microbial contaminants and infectious agents using HEPA (High Efficiency Particulate Air) filters. An overview is provided in Table 1-3 of the various classes of BSCs, the level of protection afforded by each and the appropriate risk assessment considerations. BSCs should not confused with laminar flow hood which only protect the material being worked with and are not suitable for work with infectious or toxic material. BSCs should not be confused with conventional fume hoods that do not filter microorganisms. Hazards Occupational illness due to exposure of potentially hazardous biological agents (e.g. infectious organisms) Occupational illness due to exposure of chemical (e.g. carcinogens) and radiological hazards as these are commonly used in microbial procedures. Fire may occur when the vapour from volatile or toxic chemicals build up inside an unducted Class II, Type A cabinet. Who is likely to be injured? The laboratory workers, other people (public), and the environment are at potential risk if biosafety protective measures and regulations are not adhered to. Control Measures Biosafety Guidelines and Effective Use of Biosafety Cabinets 1. Purchase The class of cabinet selected will depend on a) the risk level of the agent to be used b) the degree of protection required for the work c) whether volatile chemicals or radioisotopes will be used in the cabinet d) the type of procedure to be carried out in the cabinet Other factors: a) cost b) the other uses of the room into which the cabinet will be installed Version 2 Page 1 of 6

c) the amount of space available for installation of the cabinet. d) size of doorways which cabinet must pass through to the final point of use. e) adequate headspace for installation and for the maintenance of the filter boxes exhaust ducts, alarm systems and fans. There should be, preferably, a 30 cm clearance from the walls and ceiling. f) Availability of service connections, such as electricity 2. Certification/ Recertification BSCs must be tested and certified/ recertified after each installation within the laboratory, after each relocation, and at least annually thereafter to ensure the effectiveness of the unit. They must be certified by an approved company and the contractor to provide a copy of their certification report to the laboratory contact. 3. Operation 3.1. Start-up Procedures: a. Turn on the UV if appropriate for 15 minutes prior to use. UV irradiation is effective in killing many microorganisms. Ensure that the sash is in appropriate position. b. Turn off UV lights and turn on fluorescent light and cabinet blower. c. Check the air intake and exhaust grilles for obstructions. d. If the cabinet is equipped with an alarm, test the alarm and switch it to the "on" position. e. Confirm inward airflow by holding a tissue at the middle of the edge of the viewing panel and ensuring that it is drawn in. f. Disinfect the interior surfaces with a suitable, non-corrosive disinfectant. g. Wait 5 minutes to purge airborne contaminants from the work area. 3.2. Preparing work in the BSC: a. Before using, wipe work surface with 70% alcohol or any other disinfectant suitable for the agent(s) in use. Wipe off each item you need for your procedures before placing it inside cabinet. b. DO NOT place any objects over the front air intake grille. DO NOT block the rear exhaust grille. c. Segregate contaminated and clean items. Work from "clean to dirty." d. Place a pan with disinfectant and/or sharps container inside the BSC for pipette discard. DO NOT use vertical pipette discard canisters on the floor outside the cabinet. e. It is not necessary to flame items. When deemed absolutely necessary, touch-plate microburners equipped with a pilot light to provide a flame on demand may be used. Alternatively, use aseptic techniques and sterilized labware. f. Move arms slowly when removing or introducing new items into the BSC. g. If you use a piece of equipment that creates air turbulence in the BSC (such as a microcentrifuge or vortex), place equipment in the back 1/3 of the cabinet; stop other work while equipment is operating. h. Protect the building vacuum system from biohazards by placing a cartridge filter between the vacuum trap and the source valve in the cabinet. i. Clean up spills in the cabinet immediately. Wait 10 minutes before resuming work. 3.3. Procedures upon completion of the work: Version 2 Page 2 of 6

a. Close or cover open containers before removing them from the cabinet. b. Surface disinfects objects in contact with contaminated material before removal from the cabinet. c. Turn off the fluorescent light and cabinet blower when appropriate (some cabinets must be left on at all times; if you are unsure, check with your cabinet certifier or safety officer or building maintenance personnel). d. When work is finished, remove all materials and wipe all interior surfaces with 70% alcohol or any other disinfectant suitable for the agent(s) in use. e. Remove lab coat, gloves and other Personal Protective Equipment (PPE) and wash hands thoroughly before leaving the laboratory. 4. Training a) Every employee working in a BSC must be trained in its correct use and always adhere to biosafety precautions when conducting experiments. This will effectively reduce or eliminate the risk of exposure to potentially hazardous agents used in research. b) Have a good understanding of the different types of cabinets and how they work (attend a BSC seminar). Risk Remaining BSCs in which chemical and radiological materials are used require design modifications in the cabinet or building exhaust system to include charcoal filters, since HEPA filters do not retain agents which vapourize or sublimate. Evaluation of inherent chemicals must be part of assessment when selecting a BSC. Table 1. Selection of a Safety Cabinet Through Risk Assessment Biological Risk Protection Provided Assessed Personnel Product Environmental BSC Class BSL 1-3 YES NO YES I BSL 1-3 YES YES YES BSL 4 YES YES YES II (A, B1, B2, B3) III B1, B2 Version 2 Page 3 of 6

Table 2. Classification of Biosafety Levels for Infectious Agents Biosafety level (BSL) Agents Practices Safety Equipment (Primary Barriers) Facilities (Secondary- Barriers) 1. Not known to cause disease in healthy adult humans Standard Microbiological Practices None required Open bench top sink required 2. Associated with human disease, hazard= autoinoculation, ingestion, mucous membrane exposure BSL-1 practice plus: Limited access; Biohazard warning signs; Sharps precautions; Biosafety manual defining any needed waste decontamination or medical surveillance policies. Primary barriers= Class I or II BSC or other physical containment devices used for all manipulations of agents that cause splashes or aerosols of infectious materials; laboratory coats; gloves; face protection as needed. BSL-1 plus: Autoclave. 3. Indigenous or exotic agents with potential for aerosol transmission; disease may have serious or lethal consequences BSL-2 practice plus: Controlled access; Decontamination of all waste: Decontamination of lab clothing before laundering; Baseline serum. Primary barriers=class I or II BCSs or other physical containment devices used for all manipulations of agents; protective lab clothing; gloves; respiratory protection as needed BSL-2 plus: Physical separation from access corridors; Selfclosing, doubledoor access; Exhausted air not recirculated; Negative airflow into laboratory 4. Dangerous/exotic agents which pose high risk of life-threatening disease, aerosol- BSL-3 practices plus: Clothing change before entering; Shower on exit; Primary barriers= All procedures conducted in Class III BSCs BSL-3 plus: Separate building or isolated zone; dedicated Version 2 Page 4 of 6

transmitted lab infections; or related agents with unknown risk of transmission all material decontaminated on exit from facility. or Class I or II BSCs in combination with full-body, air-supplied, positive pressure personnel suit. supply/exhaust, vacuum, and Decon systems; requirements outlined in the reference1 Table 3. Types of Biohazard Safety Cabinets Type Face Velocity (lfpm) Airflow Pattern Radionuclides/Toxic Chemicals Biosafety Level (s) Product Protection Class I*, open front Class II: Type A 75 In at front; out rear and top through HEPA** filter 75 70% recirculated through HEPA; exhaust through HEPA No 2, 3 No No 2, 3 Yes Type B1 100 30% recirculated through HEPA; exhaust via HEPA and hard ducted Yes (Low Levels/volatility) 2, 3 Yes Type B2 100 No recirculation; total exhaust via HEPA and hard ducted Type B3 100 Same as IIA, but plus Yes 2, 3 Yes Yes 2, 3 Yes Version 2 Page 5 of 6

under negative pressure to room and exhaust air is ducted Class III NA Supply air inlets and exhaust through 2 HEPA filters Yes 3, 4 Yes *Glove panels may be added and will increase face velocity to 150 lfpm; gloves may be added with an inlet air pressure release that will allow work with chemicals/radionuclides ** HEPA: High Efficiency Particulate Airfilter lfpm: linear flow per minute Date: 26 November 2009 Prepared By: Shirley Kham Approved By: A/Prof Daniel Goh Head of Department Version 2 Page 6 of 6