The information contained in this document is intended for healthcare professionals only.



Similar documents
Total Hip Joint Replacement. A Patient s Guide

Acetabular Wedge Augment System

Why an Exactech Hip is Right for You

i-polymers for i-arthroplasty New Polymer Technologies for HIP Arthroplasty

The Crosslinked Ultra-high Molecular Weight Polyethylene

Affected Product: Polyethylene Implants from Gender Solutions Natural-Knee Flex, Natural-Knee, Natural-Knee II, MOST Options, and Apollo Systems

The Right Choice. Exeter. total hip system

BONE CEMENT. History, Performance, and Choice TECHNICAL MONOGRAPH

VERILAST Technology for Hip Replacement Implants

The information contained in this document is intended for healthcare professionals only.

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

The information contained in this document is intended for healthcare professionals only.

Knotilus TM. Anchor Instability Repair. Technique Guide

CHROMIUM STEEL POWDERS FOR COMPONENTS. JEANETTE LEWENHAGEN Höganäs AB, Sweden

Artificial Hip Implants 2011

Appendice Caratteristiche Dettagliate dei Materiali Utilizzati

on-metal Hips: Device Mechanics and Failure Modes

Zimmer Longevity Highly Cross-linked Polyethylene

Praxis Technology: Enhancements to Ti-MIM processing bring medical implants a step closer

VEGA System. PS Knee Replacement Technology. Aesculap Orthopaedics

Rim Cracking of the Cross-Linked Longevity Polyethylene Acetabular Liner After Total Hip Arthroplasty

All Suture Anchor. with IntelliBraid Technology

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

Chlorinated polyethylene ELASLEN TM. Application for Wire and Cable

DuPont Kapton HN. polyimide film

T H E A A M A C E R T I F I C A T I O N P R O G R A M

Material data sheet. EOS CobaltChrome MP1. Description

TOTAL HIP REPLACEMENT FOR A LIFETIME: THE CEMENTLESS METAL ON METAL RECONSTRUCTION

MICRO PLASTICS MOLDED NYLON 6/6 FASTENERS MECHANICAL TEST DATA - UNC - UNF SECTION

it s time for rubber to meet the road

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Amodel AS-1133 HS. polyphthalamide. Technical Data Sheet

AISI O1 Cold work tool steel

.URGENT DEVICE CORRECTION

Metal Injection Molding (MIM) of components made of Titanium and its alloys

KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET

2. Deposition process

SALT SPRAY AND IMMERSION CORROSION TESTING OF PM STAINLESS STEEL MATERIALS. W. Brian James Hoeganaes Corporation. Cinnaminson, NJ 08077

North American Stainless

X15TN TM. A high hardness, corrosion and fatigue resistance martensitic grade CONTINUOUS INNOVATION RESEARCH SERVICE.

Lap Fillet Weld Calculations and FEA Techniques

Patient Labeling Information System Description

North American Stainless

Outline of a quality system and standard for the certification of conformity

ABSTRACT INTRODUCTION

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

GUR PE-UHMW. Micropowder GUR Micropowders as Additives. Micropowder GUR Micropowders as Additives


HW 10. = 3.3 GPa (483,000 psi)

GENERAL PROPERTIES //////////////////////////////////////////////////////

Impact of ionizing radiation on the properties of a hydrobiodegradable aliphatic-aromatic copolyester

Standard Specification for Polyethylene Plastics Molding and Extrusion Materials 1

B05: Cable protection and sheathing

Validation of biomedical coatings

GRI Test Method GM19* Seam Strength and Related Properties of Thermally Bonded Polyolefin Geomembranes

Physical Dry Conditioned Unit Test method

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

Technical Data BLUE SHEET. Martensitic. stainless steels. Types 410, 420, 425 Mod, and 440A GENERAL PROPERTIES APPLICATIONS PRODUCT FORM

A new technology for high current, low insertion force, low resistance and long cycle life power connectors

PTFE Slide Bearings 04/10 149

Lentur Cable System. Surgical Technique

DENT IMPLANT restoring qualit S: of LIfE

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

ALLOY 7475 PLATE AND SHEET HIGHEST TOUGHNESS/STRENGTH

Development of an innovative bio-based structural adhesive

Effect of Sterilization Techniques on Polymers

Automotive Engineered Attachment Systems

PRELIMINARY BROCHURE. Uddeholm Ramax HH

How To Improve Metal Ion Release From An Implant

UDDEHOLM VANADIS 30 SUPERCLEAN

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

How To Make An Implant From A Metal That Is Like Bone

Biomechanics of the Lumbar Spine

Answers to commonly asked questions from patients with metal-on-metal hip replacements / resurfacings. Contents

Environmental Stress Crack Resistance Of Polyethylene

Part and tooling design. Eastman Tritan copolyester

8.7 BILLION SALES GLOBALLY ABOUT STRYKER CURRENT LANDSCAPE

PRESENTATIONS/PAPERS INTERNATIONAL. RAISING STANDARDS IN JOINT ARTHROPLASTY Course Co-Chairman, The Great Debate - London, June 2013

North American Stainless

Zimmer Persona Adverse Events Reported to FDA Through 3/27/2015

Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

North American Stainless

FM FILM ADHESIVE

PIEZOELECTRIC FILMS TECHNICAL INFORMATION

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

Experimental Pin-on-Disc Testing for Wear Simulation of Metallic and Non Metallic Pin Implant materials

Barrier Coatings: Conversion and Production Status

Projects and R&D activities

METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING

Nomex KD Technology. DuPont TM. DuPont s Heritage in Hot Gas Filtration Application. For over 4 decades, a filter media made of Nomex

North American Stainless

3M Dual Lock Reclosable Fastener

INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS

Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application

Options for Cervical Disc Degeneration A Guide to the M6-C. clinical study

Prime TC. Transport Chair. Patient Transport Redefined.

Transcription:

The information contained in this document is intended for healthcare professionals only.

X3 Knee Technology The Next Generation in Highly Crosslinked Knee Polyethylene

Innovation Matters As a pioneer in wear performance technologies, Stryker Orthopaedics has been dedicated to offering bearing surface improvements. Most recent bearing technologies have focused on hip application. While these technologies have helped to improve hip bearings, they have not been widely applied to knee bearings as wear patterns and modes vary between hips and knees. Most commercial crosslinking processes involve both irradiation and a subsequent remelting step, which decreases the strength of the polyethylene 1. Stryker s patented annealing process provides wear 2, 3, 4, 5 reduction without compromising structural strength. Wear performance technologies for knee applications cannot come at the expense of the structural strength of the polyethylene. Keeping this in mind, Stryker developed a next generation process with three sequential irradiation/annealing steps to create X3 polyethylene. The results > Preserved Strength 2, 6 4, 5, 7 > Reduced Wear 2, 8, 9 > Oxidation Resistance The X3 process:

Strength Matters Remelting following irradiation of polyethylene significantly alters the crystallinity and crystalline morphology, with to up to a 35% drop in ultimate tensile strength and a 15% drop in yield stress 1 (Figure 1). Figure 1: The higher the irradiation dose, the more remelting compromises the tensile strength of the polyethylene. In contrast to remelting, annealing following irradiation has been shown to maintain those morphologies leading to preserved structural strength 2 (Figure 2). This structural strength allows X3 technology to be applied to knee applications where abrasive, adhesive and fatigue wear may be present due to a more linear motion pattern. 10 Figure 2: Maintenance of structural strength allows X3 technology to be applied to tibial bearings that are subject to greater shear stresses such as posteriorly stabilized tibial inserts. These shear loads on the PS post create a moment arm to the locking mechanism, increasing the stress on the polyethylene in the posterior region of the mechanism. 11

Wear Matters X3 polyethylene has been shown to reduce the wear rate of tibial inserts by up to 79% compared to 4, 5, 7 conventional polyethylene (Figure 3). Figure 3: Knee simulator testing shows up to 79% wear reduction in Scorpio CR tibial inserts compared to conventional polyethylene. X3 polyethylene shows a 41% reduction in wear compared to Prolong highly crosslinked polyethylene. This test compared wear rates of Scorpio X3 tibial inserts vs. Scorpio inserts machined from packaged Zimmer Prolong NexGen inserts 12 (Figure 4). Prolong material is prepared by electron beam irradiation of UHMWPE stock to 65 kgy followed by remelting. 13 Figure 4: For this test, large sized packaged Prolong tibial inserts were machined into the shape of Scorpio inserts. A head-to-head test was performed to compare the wear rates of the two materials.

Oxidation Resistance X3 polyethylene demonstrates high oxidation resistance under extreme laboratory conditions (immersion in 5 atmospheres of oxygen at 70 degrees Celsius for 14 days) 2 (Figure 5). Figure 5: Oxidation resistance is shown to be similar to virgin, unirradiated polyethylene. X3 polyethylene maintains mechanical properties after accelerated oxidative age laboratory testing. No statistical difference was found for tensile-yield strength, ultimate 2, 8, 9 tensile strength, and elongation (Figure 6). Figure 6: X3 maintains mechanical strength after artificial accelerated aging.

References 1. Wang, A., Manley, M., Serkeian, P., Wear and Structural Fatigue Simulation of Crosslinked Ultra-High Molecular Weight Polyethylene for Hip and Knee Bearing Applications, Crosslinked and Thermally Treated Ultra-High Molecular Weight Polyethylene for Joint Replacements, ASTM STP1445, Kurtz, S.M., Gsell, R., and Martell, J., Eds., ASTM International, West Conshohecken, PA 2003, pp. 151-168. 2. Yau, S.S., Wang, A., Essner, A., Manley, M., Dumbleton, J., Sequential Irradiation and Annealing of highly Crosslinked Polyethylenes: Resist Oxidation without Sacrificing Physical/Mechanical Properties, Transactions of the 51st Annual Meeting of the Orthopaedic Research Society, Washington, DC 2005: 1670. 3. Essner, A., Yau, S.S., Schmidig, G., Wang, A., Dumbleton, J., Manley, M., Serekian, P., Reducing Hip Wear Without Compromising Mechanical Strength: A Next Generation Crosslinked and Annealed Polyethylene. Transactions of the 5th Combined Meeting of the Orthopaedic Research Societies of Canada, USA, Japan and Europe, Calgary, Canada 2004: 80. 4. Essner, A., Herrera, L., Yau, S.S., Wang, A., Dumbleton, J.H., Manley, M.T., Sequentially Crosslinked and Annealed UHMWPE CR Knee Wear, Transactions of the 51st Annual Meeting of the Orthopaedic Research Society, Washington, DC 2005: 312. 5. Essner, A., Zeng, H., Yau, S.S., Wang, A., Dumbleton, J.H., Manley, M.T., Stair Climbing Knee Wear Simulation: Sequentially Crosslinked and Annealed UHMWPE, Transactions of the 30th Annual Meeting of the Society for Biomaterials, Memphis 2005: 199. 6. X3 UHMWPE maintains mechanical properties for Tensile Yield Strength and Ultimate Tensile Strength of N 2 Vac gamma sterilized UHMWPE as measured by ASTM D638. Tensile Yield Strength was 23.2 +/- 0.4 MPa and 23.5 +/- 0.3 MPa for N 2 Vac UHMWPE and X3 UHMWPE, respectively. Ultimate Tensile Strength was 54.8 +/- 2.5 MPa and 56.7 +/- 2.1 MPa for N 2 Vac UHMWPE and X3 UHMWPE, respectively. 7. Stryker Orthopaedics Scorpio CR tibial inserts made from X3 UHMWPE, 72-22-0708, show a 79% reduction in volumetric wear rate versus the same insert fabricated from N 2 Vac gamma sterilized UHMWPE, 72-2-0708. The insert tested was size 7, 8mm thick. Testing was conducted under multiaxial knee simulator (multi-station MTS knee joint simulator [1]) for five million cycles using appropriate size CoCr counterfaces, a specific type of diluted calf serum lubricant and the motion and loading conditions, representing normal walking, outlined in ISO/DIS 14243-3. Volumetric wear rates were 34.6 ± 1.5mm3/10 6 cycles for test samples. Test inserts were exposed to a gas plasma sterilization process. In vitro knee wear simulator tests have not been shown to quantitatively predict clinical wear performance. [1] Essner, A., Wang, A., Stark, C., and Dumbleton, J. H., A Simulator for the Evaluation of Total Knee Replacement Wear, 5th World Biomaterials Congress, Toronto, Canada, May 1996, pg. 580. 8. X3 UHMWPE maintains mechanical properties after accelerated oxidative aging. No statistical difference was found for Tensile Yield Strength, Ultimate Tensile Strength and Elongation as measured per ASTM D638 before and after exposure to ASTM F2003 accelerated aging (5 Atmospheres (ATM) of oxygen at 70ºC for 14 days). Tensile Yield Strength was 23.5 +/- 0.3 MPa and 23.6 +/- 0.2 MPa, Ultimate Tensile Strength was 56.7 +/- 2.1 MPa and 56.3 +/- 2.3 MPa and Elongation was 267 +/- 7% and 266 +/- 9% before and after accelerated oxidative aging, respectively. 9. X3 UHMWPE resists the effects of oxidation. No statistical difference was found for Tensile Yield Strength, Elongation, Crystallinity and Density as measured per ASTM D638, D3417 and D1505 before and after ASTM F2003 accelerated aging (5 ATM of oxygen at 70ºC for 14 days). Tensile Yield Strength was 23.5 +/- 0.3 MPa, and 23.6 +/- 0.2 MPa Ultimate Tensile Strength was 56.7 +/- 2.1 MPa and 56.3 +/- 2.3 MPa, Elongation was 267 +/- 7% and 266 +/- 9%, Crystallinity was 61.7 +/- 0.6% and 61.0 +/- 0.5% and Density was 939.2 +/- 0.1kg/m3 before and after accelerated oxidative aging, respectively. 10. Wang, A., Essner, A., Stark, C., Dumbleton, J.H., A Biaxial Line-Contact Wear Machine for the Evaluation of Implant Materials for Total Knee Joint Replacement. Wear 225-229. 1999 701-707. 11. Stryker Orthopaedics Test Report: RD-04-116. 12. Herrera, L., Essner, A., Wang, A., Wear of Two Differently Crosslinked Tibial Bearing Materials Under Stair-Climbing Conditions. Report on file at Stryker Orthopaedics. 13. Zimmer Prolong product brochure. Joint Replacements Trauma Craniomaxillofacial Spine Orthobiologics Instruments Interventional Pain Navigation Endoscopy Communications Imaging Patient Handling Equipment EMS Equipment 325 Corporate Drive Mahwah, NJ 07430 t: 201 831 5000 www.stryker.com The information presented in this brochure is intended to demonstrate the breadth of Stryker product offerings. Always refer to the package insert, product label and/or user instructions before using any Stryker product. Surgeons must always rely on their own clinical judgment when deciding which treatments and procedures to use with patients. Products may not be available in all markets. Product availability is subject to the regulatory or medical practices that govern individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. Products referenced with TM designation are trademarks of Stryker. Products referenced with designation are registered trademarks of Stryker. Literature Number: LX3KB MS/GS 10m 12/05 Copyright 2005 Stryker Printed in USA