MEDICAL DEVICE GUIDANCE



Similar documents
FINAL DOCUMENT. Global Harmonization Task Force. Title: Label and Instructions for Use for Medical Devices

GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES

SMF Awareness Seminar 2014

2002 No. 618 CONSUMER PROTECTION. The Medical Devices Regulations 2002

Contents. Abstract...i. Committee Membership... iii. Foreword... vii. 1 Scope...1

Ethiopian Food, Medicine and Healthcare Administration and Control Authority. Medical Equipment Donation Directive

EUROPEAN COMMISSION HEALTH AND CONSUMERS DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union

GOOD DISTRIBUTION PRACTICE FOR MEDICAL DEVICES (GDPMD)

What Does Having a FDA Cleared Pregnancy Test Mean?

GUIDANCE NOTES FOR MANUFACTURERS OF CLASS I MEDICAL DEVICES

Validation and Calibration. Definitions and Terminology

REGULATION (EEC) No 2309/93

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

Medical Software Development. International standards requirements and practice

Update: Proposed Medical Device Regulation (MDR) & IVD Regulation (IVDR)

Guidance on the In Vitro Diagnostic Medical Devices Directive 98/79/EC

GUIDELINES ON MEDICAL DEVICES. IVD GUIDANCES : Borderline issues A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

Risk Assessment for Medical Devices. Linda Braddon, Ph.D. Bring your medical device to market faster 1

The Regulation of Medical Devices in the UK

Manual for ITC's clients, Conformity assessment of ACTIVE IMPLANTABLE MEDICAL DEVICES pursuant to Council Directive 90/385/EEC

Guidance Notes for Applicants of the Certificate for Clinical Trial on Medical Device

(OJ L 169, , p. 1)

Guide for Custom-Made Dental Device Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994

Good Research Practice

Pre-market Information - Class III and IV

Having regard to the Treaty establishing the European Economic Community, and in particular Article 100 thereof;

2.0 Rationale, Purpose and Scope Definitions General Principles... 7

Aesculap Service Systems Instrument Management

DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

REQUIREMENTS FOR AN ACCREDITED VETERINARY MEDICAL DIAGNOSTIC LABORATORY

RADIOPHARMACEUTICALS BASED ON MONOCLONAL ANTIBODIES

Australian Medical Devices Guidance Document Number XX. Custom Made Medical Devices

Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702

SPECIFICATIONS AND CONTROL TESTS ON THE FINISHED PRODUCT

International Consortium for Harmonization of Clinical Laboratory Results. Operating Procedures

Medical Devices/Equipment Management. Compliance with the HSE s Medical Devices and Equipment Management Standard. Guidance for Service Areas

Quality Assurance (QA) & Quality Control (QC)

Content Sheet 3-1: Equipment Management Overview

MEDICAL DEVICES SECTOR

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION

Medical Devices: CE Marking Step-by Step

FDA Public Hearing on Clinical Accuracy Requirements for Point of Care Blood Glucose Meters (BGMs)

The Act on Medical Devices

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

How To Inspect A Blood Bank

Content Sheet 5-1: Overview of Sample Management

PROPOSED UPDATED TEXT FOR WHO GOOD MANUFACTURING PRACTICES FOR PHARMACEUTICAL PRODUCTS: MAIN PRINCIPLES (JANUARY 2013)

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

UNDERSTANDING THE EC DIRECTIVE 98/79/EC ON IN VITRO DIAGNOSTIC MEDICAL DEVICES

COMMISSION DIRECTIVE 2003/94/EC

JANUARY 2013 PREPARATION OF A SITE MASTER FILE FOR A MANUFACTURER OF COSMETIC PRODUCTS

GUIDELINES FOR FOOD IMPORT CONTROL SYSTEMS

Med-Info. Council Directive 93/42/EEC on Medical Devices. TÜV SÜD Product Service GmbH

Policy Document Control Page

2. Contact Person: Garo Mimaryan, MS., RAC 7 Technical Regulatory Affairs Specialist III 3. Phone Number: (914)

Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702

SUPPLIER QUALITY MANAGEMENT SYSTEM QUESTIONNAIRE

Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM

Federal Wage System Job Grading Standard For Laboratory Working, Table of Contents

State Meat and Poultry Inspection (MPI) Program Laboratory Quality Management System Checklist

IMPURITIES IN NEW DRUG PRODUCTS

Quality Management System Manual

Procedure for Equipment Calibration and Maintenance

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Guidance for Industry

Recent Updates on European Requirements and what QPs are expected to do

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Medical Device Regulatory Requirements for Taiwan

RESOLUTION-RDC Nr- 48, OF OCTOBER 6, 2009

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Florida Nursing Assistant Academy #2926 COURSE SYLLABUS

Guidance for manufacturers and Notified Bodies on reporting of Design Changes and Changes of the Quality System

Good Clinical Laboratory Practice (GCLP) An international quality system for laboratories which undertake the analysis of samples from clinical trials

Final Document. Software as a Medical Device (SaMD): Key Definitions. Date: 9 December Despina Spanou, IMDRF Chair. IMDRF/SaMD WG/N10FINAL:2013

5th Edition NetCord-FACT International Standards for Cord Blood Collection, Banking, and Release for Administration. Summary of Changes

APPLICABLE TO: All UTMB Health personnel, students, departments and properties

NC SBI QUALITY ASSURANCE PROGRAM

SAMPLE. Effects of Different Sample Types on Glucose Measurements

MEDICAL LABORATORY SUPERVISOR COMPETENCY PROFILE ROLE DESCRIPTIONS BY COMPETENCY LEVEL

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

GUIDELINES FOR IMPORT AND MANUFACTURE OF MEDICAL DEVICES

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

For more information please contact your local UL field representative

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

Hazardous Substances and New Organisms Act 1996

OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA)

In vitro diagnostic reagent, calibrator and control material stability

MEDICAL DEVICES INTERIM REGULATION

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

MEDICAL DEVICE TECHNICAL SPECIFICATION

Correspondence between ISO 13485:2003 and the US Quality System Regulation

American Association for Laboratory Accreditation

Medical Device Regulatory Requirements for Mexico

MLT 118L Clinical Immunology/Immunohematology Lab

Medical/Clinical Assistant CIP Task Grid

Unique Device Identifier System: Frequently Asked Questions, Vol. 1 Guidance for Industry and Food and Drug Administration Staff

Transcription:

May 2014 MEDICAL DEVICE GUIDANCE GN-23: Guidance on Labelling for Medical Devices

PREFACE This document is intended to provide general guidance. Although we have tried to ensure that the information contained here is accurate, we do not, however, warrant its accuracy or completeness. The Health Sciences Authority (HSA) accepts no liability for any errors or omissions in this document, or for any action/decision taken or not taken as a result of using this document. The information contained in this document should not be a substitute for professional advice from your own professional and healthcare advisors. HEALTH SCIENCES AUTHORITY HEALTH PRODUCTS REGULATION GROUP Page 2 of 13

1. INTRODUCTION 1.1. Purpose This document is meant to provide general guidance on labelling for medical devices. 1.2. Background Labelling serves to communicate safety and performance related information to users of medical devices and/or patients as well as to identify individual devices. Such information may appear on the device itself, on the packaging, as instructions for use or in a patient information leaflet. 1.3. Scope This document applies to all medical devices, including in vitro diagnostic medical devices. 1.4. Definitions Definitions that do not indicate they are set out in the Health Products Act 2007 (Act) or Health Products (Medical Devices) Regulations (Regulations) are intended as guidance in this document. These definitions are not taken verbatim from the above legislation and should not be used in any legal context. These definitions are meant to provide guidance in layman terms. CLINICAL INVESTIGATION: Any systematic investigation or study in or on one or more human subjects, undertaken to assess the safety and/or performance of a medical device. Explanation: This term is synonymous with clinical trial and clinical study. Clinical investigations include feasibility studies and those conducted for the purpose of gaining market approval, as well as investigations conducted following marketing approval. HEALTH SCIENCES AUTHORITY HEALTH PRODUCTS REGULATION GROUP Page 3 of 13

Routine post market surveillance may not constitute a clinical investigation (e.g. investigation of complaints, individual vigilance reports, literature reviews). LABEL (as set out in the Act): in relation to a health product or an active ingredient, means any written, printed or graphic representation that appears on or is attached to the health product or active ingredient or any part of its packaging, and includes any informational sheet or leaflet that accompanies the health product or active ingredient when it is being supplied. LAY PERSON: An individual who does not have formal training in a relevant field or discipline. INSTRUCTIONS FOR USE: Information provided by the product owner to inform the device user of the product s proper use and of any precautions to be taken. INTENDED PURPOSE: The use for which the medical device is intended according to the specifications of its product owner as stated on any or all of the following: the label of the medical device; the instructions for use of the medical device; the promotional materials in relation to the medical device. MEDICAL DEVICE: means a medical device as described in the First Schedule of the Act. PERFORMANCE EVALUATION: A review of the performance of a medical device based upon data already available, scientific literature and, where appropriate, laboratory, animal or clinical investigations. PRODUCT OWNER: for the purposes of this guidance document, means a person who sells a medical device under his own name, or under a trademark, design, trade name or other name or mark owned or controlled by the HEALTH SCIENCES AUTHORITY HEALTH PRODUCTS REGULATION GROUP Page 4 of 13

person, and who is responsible for designing, manufacturing, assembling, processing, labelling, packaging, refurbishing or modifying the device, or for assigning to it a purpose, whether those tasks are performed by that person or on their behalf. REFURBISHMENT: A refurbishment of a medical device is taken to have occurred if the medical device, or a part of the device, is substantially rebuilt from one or more used medical devices of that kind so as to create a medical device that is able to be used for the purpose originally intended by the product owner of the original device. A refurbishment of a medical device may involve the following actions: stripping the device into component parts or sub-assemblies; checking parts of the device for suitability for reuse; replacing component parts or sub-assemblies of the device that are not suitable for reuse; assembling reclaimed or replacement component parts or sub-assemblies of the device or another used device; testing a reassembled device against the specifications of the original device or, if the product owner has revised those specifications, the revised specifications; identifying an assembled device as a refurbished device. RESEARCH USE ONLY MEDICAL DEVICE: A medical device that has been made available to institutions/laboratories solely for their use in studies involving the collation of data. The device is not intended for any medical purpose or objective. HEALTH SCIENCES AUTHORITY HEALTH PRODUCTS REGULATION GROUP Page 5 of 13

2. LABELLING REQUIREMENTS 2.1. General Guidelines The labelling for all medical devices should adhere to these general guidelines:- As far as it is practical and appropriate, the information needed to identify and use the device safely should be provided on the device itself, and /or on the packaging for each unit (primary level of packaging), and / or on the packaging of multiple devices (secondary level of packaging). If individual packaging of each unit is not practicable, the information should be set out in the leaflet, packaging insert or other media supplied with, or applicable to, one or multiple devices. Where the product owner supplies multiple devices to a single user and/or location, it may be sufficient and appropriate to provide with them only a single copy of the instructions for use. In these circumstances the device user should have access to further copies upon request. The medium, format, content, readability and location of labelling should be appropriate to the particular device, its intended purpose and the technical knowledge, experience, education or training of the intended user(s). In particular, instructions for use should be written in terms readily understood by the intended user and, where appropriate, supplemented with drawings and diagrams. Some devices may require separate information for the healthcare professional and the lay user. Instructions For Use (IFU) may not be needed or may be abbreviated for devices of low or moderate risk if they can be used safely and as intended by the product owner without any such instructions. Paper versions of all labelling must accompany the product. Any residual risk identified in the risk analysis should be reflected as contraindications or warnings within the labelling. The use of internationally recognised symbols is encouraged provided that device safety is not compromised by a lack of understanding on the part of the patient or user. Where the meaning of the symbol is not obvious to the device user, e.g. for a lay-user or for a newly introduced symbol, an HEALTH SCIENCES AUTHORITY HEALTH PRODUCTS REGULATION GROUP Page 6 of 13

explanation should be provided. All characters on labelling must be of adequate size and legibly printed. The product labelling must be in English. 2.2. Content of Labelling 2.2.1. Primary and Secondary Levels of Packaging Contact Information It is mandatory to include the name and contact details (address and/or phone number and/or fax number and/or website address to obtain technical assistance) of the Product Owner on the labelling. General The labelling for all medical devices should bear the following:- Sufficient details for the user to identify the device and, where these are not obvious, its intended purpose, user and patient population of the device; also, where relevant, the contents of any packaging. An indication of either the batch code/lot number (e.g. on single-use disposable devices or reagents) or the serial number (e.g. on electricallypowered medical devices), where relevant, to allow appropriate actions to trace and recall the devices. An unambiguous indication of the date until when the device may be used safely, expressed at least as the year and month (e.g. on devices supplied sterile, single-use disposable devices or reagents), where this is relevant. Where relevant, the storage conditions and shelf life following the first opening of the primary container, together with the storage conditions and stability of working solutions. For devices other than those covered by the above, and as appropriate to the type of device, an indication of the date of manufacture. This indication may be included in the batch code/lot number or serial number. The information needed to verify whether the device is properly installed and can operate correctly and safely, including details of the nature, and frequency of preventative and regular maintenance, where relevant any HEALTH SCIENCES AUTHORITY HEALTH PRODUCTS REGULATION GROUP Page 7 of 13

quality control, replacement of consumable components, and calibration needed to ensure that the device operates properly and safely during its intended life. Any warnings, precautions, limitations or contra-indications. The performance intended by the product owner and, where relevant, any undesirable side effects. An indication on the external packaging of any special storage and /or handling conditions that applies. Details of any further treatment or handling needed before the device can be used (e.g. sterilisation, final assembly, calibration, preparation of reagents and/or control materials, etc.) where relevant. The inclusion of the manufacturing site of the medical device and contact information of the importer is optional. NOTE Please note that "manufactured/made in Singapore" or other similar wordings can only be printed on the labels if there is significant processing of the products in Singapore. The following are excluded: simple operations consisting of removal of dust, sifting or screening, sorting, classifying, matching (including the making up of sets of articles), washing, painting, cutting up; changes of packing and breaking up and assembly of consignments; simple placing in bottles, flasks, bags, cases, boxes, fixing on cards or boards, and all other simple packing operations; the affixing of marks, labels or other like distinguishing signs on products or their packaging; etc. Additional Requirements The labelling for some medical devices should contain the following additional information: If the device is sterile, an indication of that condition and necessary instructions in the event of damage to sterile packaging and, where appropriate, description of methods of re-sterilisation. If the device has been specified by the product owner as intended for single-use only, an indication of that state. If the device is reusable, information on the appropriate processes to allow reuse, including cleaning, disinfection, packaging and, where HEALTH SCIENCES AUTHORITY HEALTH PRODUCTS REGULATION GROUP Page 8 of 13

appropriate, the method of re-sterilisation and any restriction on the number of reuses. Where a device is supplied with the intention that it is sterilised before use, the instructions for cleaning and sterilisation should be such that, if correctly followed, the device will still perform as intended by the product owner and comply with the Essential Principles of Safety and Performance of Medical Devices. If the device is a refurbished device, identification of the device as a refurbished device. If the device is for use by a single individual and has been manufactured according to a written prescription or pattern (i.e. it is custom-made), an indication of that state. If the device is intended for clinical investigation or, for in vitro diagnostic medical devices, performance evaluation only, an indication of that situation. If the device is intended for research use only, it must be labelled as research use only. If the device is intended for presentation or demonstration purposes only, it must be labelled as for presentation or demonstration purposes only: not for use on humans. If the device is implantable, information regarding any particular risks in connection with its implantation. If the device emits radiation for medical purposes, details of the nature, type and where appropriate, the intensity and distribution of this radiation. Information regarding the risks of reciprocal interference posed by the reasonably foreseeable presence of the device during specific investigations, evaluations, treatment or use (e.g. electromagnetic interference from other equipment). If the device is to be installed with or connected to other medical devices or equipment, or with dedicated software, in order to operate as required for its intended use, sufficient details of its characteristics to identify the correct devices or equipment to use in order to obtain a safe combination. If the device is an in vitro diagnostic medical device, it must be labelled as in vitro diagnostic or IVD. HEALTH SCIENCES AUTHORITY HEALTH PRODUCTS REGULATION GROUP Page 9 of 13

2.2.2. Instructions For Use (IFU)/ Patient Information Leaflet For medical devices where an IFU or a patient information leaflet is applicable, additional information on the date of issue or latest revision of the instructions for use and, where appropriate, an identification number should be provided. The instructions for use should also include, where appropriate, details informing the users and/or patient and allowing the medical staff to brief the patient on any contra-indications, warnings and any precautions to be taken. These details should, in particular, cover:- Precautions and/or measures to be taken in the event of changes in the performance, or malfunction, of the device including a contact telephone number, if appropriate. Precautions and/or measures to be taken as regards exposure, in reasonably foreseeable environmental conditions, to magnetic fields, external electrical influences, electrostatic discharge, pressure or variations in pressure, temperature, humidity, acceleration, thermal ignition sources, proximity to other devices, etc. If the device administers medicinal products, adequate information regarding any medicinal product(s) that the device in question is designed to administer, including any limitations in the choice of substances to be delivered. Any medicinal substances or biological material incorporated into the device as an integral part of the device. If the device has a measuring function, the degree of accuracy claimed for it. Any requirement for special facilities, or special training, or particular qualifications of the device user and/or third parties. Any precautions to be taken related to the disposal of the device and/or its accessories (e.g. lancets), to any consumables used with it (e.g. batteries or reagents) or to any potentially infectious substances of human or animal origin. HEALTH SCIENCES AUTHORITY HEALTH PRODUCTS REGULATION GROUP Page 10 of 13

Where relevant, for devices intended for lay persons a statement clearly directing the user not to make any decision of medical relevance without first consulting his or her health care provider. In Vitro Diagnostic Medical Devices For in vitro diagnostic medical devices, in addition to the information required above, directions/instructions for the proper use of in vitro diagnostic medical devices that should be contained in the labelling include: Intended purpose, including the following information:- (a) Type of analyte or measurand of the assay. (b) Whether the test is quantitative or qualitative. (c) Role of the test in the clinical use e.g. screening, diagnostic or detection, aid to diagnostic, monitoring. (d) Disease or condition that the test is intended for. (e) Type of specimen to be used e.g. serum, plasma, etc. (f) The intended users (e.g. self-testing by lay person, near-patient by trained personnel or professionals). (g) Assay type (e.g. immunoassay, chemistry, cytochemistry, image analysis, immunohistochemistry, etc). (h) The specific name of the instrument required for the assay, if any. (i) For instruments, the intended use should also include the modes of operation for instruments e.g., random access, batch, stat, open tube, closed tube, automatic, manual. Test principle. Specimen type. Conditions for collection, handling, storage and preparation of the specimen. Reagent description and any limitation (e.g. use with a dedicated instrument only). The metrological traceability of values assigned to calibrators and trueness-control materials, including identification of applicable reference materials and/or reference measurement procedures of higher order. Assay procedure including calculations and interpretation of results. HEALTH SCIENCES AUTHORITY HEALTH PRODUCTS REGULATION GROUP Page 11 of 13

Information on interfering substances that may affect the performance of the assay. Performance characteristics (summarised analytical and diagnostic sensitivity, specificity, reproducibility, etc). Reference intervals. Study design (population studies, N, type of sample, matrix, dilution, target concentrations, etc). HISTORY HEALTH SCIENCES AUTHORITY HEALTH PRODUCTS REGULATION GROUP Page 12 of 13

Contact Information: Medical Device Branch Pre-marketing Division Health Products Regulation Group Health Sciences Authority 11 Biopolis Way, #11-03 Helios Singapore 138667 www.hsa.gov.sg Tel: 6866 3560 Fax: 6478 9028 Email: hsa_md_info@hsa.gov.sg