Priority School Building Programme



Similar documents
EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Adapting to Change: New Thinking on Comfort Natural ventilation in UK schools: design options for passive cooling Steven Firth* and Malcolm Cook

School Performance Specifications. SPACES Engineering Technical Meeting 22 September 2015

Mistrale. Fusion Terminal

Adaptive strategies for office spaces in the UK climate

energy in education promoting energy efficiency in schools

Energy Efficient HVAC-system and Building Design

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

Mechanical and Natural Ventilation

3-D Modeller Rendered Visualisations

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

How To Get A Passive House

Passive & Active Design

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

HEATING, VENTILATION & AIR CONDITIONING

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Information paper 20. Prepared by: David Clark. book:

Energy Saving Fact Sheet Air Conditioning

ResearcH JournaL 2009 / VOL

Acoustic design of schools: performance standards. From 2003 to 2014: a brief guide to the changes in BB 93. by Jack Harvie-Clark, 9th January 2015

Directorate for the Built Environment Building Standards Division

Life cycle cost comparison of TAB vs. other HVAC (UK) TECHNICAL BROCHURE

VENTILATIVE COOLING EBC ANNEX 62 PER HEISELBERG DEPARTMENT OF CIVIL ENGINEERING

AN APPLICATION MANUAL FOR BUILDING ENERGY AND ENVIRONMENTAL MODELLING

Parametric Analysis of School Classroom Typologies' Energy Performance

SCHOOL DESIGN: OPTIMISING THE INTERNAL ENVIRONMENT BUILDING OUR FUTURE: SCOTLAND S SCHOOL ESTATE

Guidelines for Environmental Design in Schools

Air Conditioning, Comfort and Energy in India s Commercial Building Sector

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

CIBSE Weather Files 2016 release: Technical Briefing and Testing

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

Energy savings in the residential area are essential in

Energy Efficiency HOSPITALITY.

Norwegian Tax Authority - Oslo Norway

ELIMINATING AIR CONDITIONERS IN NEW SOUTHERN CALIFORNIA HOUSING

White Paper Nest Learning Thermostat Efficiency Simulation for France. Nest Labs September 2014

Holistic Approach in Delivering Government Buildings The Low Carbon Concept

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Using Time-of-Day Scheduling To Save Energy

Passive Solar Design and Concepts

High Performance School Buildings Resource and Strategy Guide

IES <Virtual Environment> Tutorial. Apache Sim (Version 6.0)

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

Home Screen...4. Quick Start Guide...5. MyAir Standalone Zone Controls only...5. MyAir Zone Controls With Integrated Unit On/Off Control...

VE Compliance FAQ. Top Tips for Achieving Compliance

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Energy efficient home design

BREEAM Refurbishment and Fit-out 2014 Briefings. Part of the BRE Trust

HVAC Processes. Lecture 7

Draft UCL Heating, Cooling and Ventilation Policy

National Calculation Methodology (NCM) modelling guide (for buildings other than dwellings in England and Wales)

CONTROL STRATEGIES FOR HVAC SYSTEMS

Condensing Boiler Efficiency

Federation of European Heating, Ventilation and Air-conditioning Associations

DK2 IEA. Replacing mechanical ventilation with natural ventilation at Enghøjskolen school in Denmark

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

How To Design A Room Air Conditioning System

Heating and cooling. Insulation. Quick facts on insulation:

Using Building Energy Management Systems (BEMS) Best Practice for Energy and Carbon Savings.

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Bright Ideas. A Smarter Business Guide to Energy Efficiency

Acoustic design of schools: performance standards. Building bulletin 93

CHAPTER 3. The sun and the seasons. Locating the position of the sun

Hybrid heat pumps. saving energy and reducing carbon emissions

A Roof Integrated Solar Heating System Without Storage

CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?

Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes

CEN/TC 156. pren Date: CEN/TC 156. Secretariat: BSI ICS: Descriptors:

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

Kan behovsstyrt ventilasjon erstatte lokal varme? Axel Cablé, SINTEF Seminar

DesignBuilder EMS - Intro

The Business Case Annual fuel cost savings of 26% worth more than 28,000 Annual fuel savings of 1.3million kwh Annual CO2 savings of over 245 tonnes

Catalyst RTU Controller Study Report

Innovative solution for heat recovery of ventilation air in older apartment buildings - with low intervention affecting the residents

APPLICATION OF DATA MINING TECHNIQUES FOR BUILDING SIMULATION PERFORMANCE PREDICTION ANALYSIS.

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

Ecofys VII U-Values for Better Energy Performance of Buildings

Energy Efficiency in Buildings

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

The impact of climate change on the environmental design of buildings

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Transcription:

UPDATE Includes June 2013 changes to FOS Priority School Building Programme Making sense of the new Priority School Output Specification from the Education Funding Agency. How is the output specification different from previous guidelines, how do the standard school designs meet the output specification and how Breathing Buildings can help you model the ventilation system energy use in IES. Background The Education Funding Agency (EFA launched their baseline designs for schools in October 2012. The school designs set out to show examples of how the Output Specification for schools to be built under the Priority School Building Programme (PSBP could be achieved within the set costs and area allowances. Breathing Buildings worked with the EFA to develop the Output Specification, helping them assess alternative ventilation strategies and review the energy modelling results. The baseline designs cover 3 standard schools: a 420 place primary, with a nursery of 26; a 1,200 place fingerblock secondary school; and a 1,200 place superblock secondary school. Key Design Principles The baseline designs have been developed using the following key principles: Functionality Health & Safety Standardisation Future-proofing Sustainability The final Facilities Output Specification was issued in June 2013. The EFA have stated that they expect contractors to develop their own schemes to meet the Output Specification. The baseline designs are a potential starting point, but if contractors have different ideas they will be accepted so long as they meet the Output Specification criteria and cost targets. This document lays out the key ventilation design challenges and how Breathing Buildings can help you comply.

02 03 Air freshness GOODBYE BB101 Hello Adaptive Thermal Comfort For naturally ventilated buildings, the maximum daily average carbon dioxide (CO 2 levels are still 1,500ppm (the same as BB101, although the maximum acceptable value for a maximum of 20 minutes has been reduced to 2,000ppm. Internal Climate The baseline designs share many of our core beliefs about the importance of a sustainable ventilation strategy in achieving a sustainable building. Notably they incorporate the following: Cross ventilation (enhanced airflow in all parts of a room leads to improved thermal comfort especially in warmer weather Low energy hybrid (some fan use within an otherwise natural ventilation scheme provides a much more robust way of minimising energy use whilst at the same time preventing cold draughts in winter and managing the risks of overheating in summer Not using windows in winter as these invariably cause cold draughts Using thermal mass to manage risks of summertime overheating. Baseline Designs in IES For us it is not enough to simply understand the challenges of the output specification, we have demonstrated compliance by modelling the schools in IES and 4DFlo. This shows that we not only meet the output specification but that using our products gives better performance than a MVHR solution. The Future We believe that the output specification will drive the development of future issues of BB101 and BB93. Having helped in the development of the output specification we are uniquely placed to help contractors and engineers ensure that their school design project delivers a low energy project with a superb indoor climate. Winter Mode Winter Mixing Ventilation Weather files PSBP stipulates the use of the Design Summer Year (DSY weather files, which makes it more challenging to avoid overheating than BB101 which accepted the use of the cooler Test Reference Year (TRY weather files. Operative temperature PSBP sees the use of operative temperature as a measure of thermal comfort. In CIBSE Guide A operative temperature is defined as: operative temperature = ½ (air temp + ½ (mean radiant temp The Breathing Buildings 4DFlo software calculates the operative temperature which makes design work easier. Furthermore, the Breathing Buildings dynamic thermal modelling software automatically informs the designer whether the design complies with the new overheating criteria without post-processing. This makes the design process much faster. Adaptive Comfort One aspect of the adaptive comfort philosophy is based on the premise that past thermal history modifies building occupants thermal expectations and preferences. An example of this would be that during a warm weather spell, occupants would feel comfortable in a building that would otherwise be considered too warm. To calculate the acceptable temperatures and the number of hours exceeding these, PSBP requires the use of a number of values from thermal modelling. These are automatically generated by the Breathing Buildings dynamic thermal modelling software 4DFlo: Running mean temperature, T rm (calculated from weather files Operative temperature, T op (calculated from dynamic thermal modelling, such as Breathing Buildings 4DFlo Maximum acceptable temperature, T max (calculated from weather files Hours of Exceedance, H e (calculated from dynamic thermal modelling Weighted Exceedance, W e (calculated from dynamic thermal modelling Threshold / upper limit temperature, T upp (calculated from weather files For mechanically ventilated buildings, this requirement has been lowered to a maximum daily average of 1,000ppm, with a maximum of 1,500ppm for a maximum of 20 minutes per day. This has implications involving the amount of heat lost in cold weather, and the fan power required to provide nearly twice as much outside air for a mechanical system compared with a natural system. Overheating Criteria In the same way as BB101, there are three criteria, of which you must pass two but can fail one. However in general there is a shift from the use of 28 C, 32 C and a 5 C ΔT as a metric, to the use of Adaptive Comfort (EN 15251 to set the maximum desired internal temp (T max in the space. The Adaptive Comfort criteria are in line with the new criteria replacing the existing criteria in CIBSE Guide A. For free running (not mechanically cooled buildings T max is calculated using the equation: T max = 0.33T rm + 21.8 Where T rm is the running mean temperature, which is a weighted daily average of external temperatures over the previous 7 days. This can be calculated using the following equation: T rm = (T (ed-1+0.8t (ed-2+0.6t (ed-3+0.5t (ed-4+0.4t (ed-5+0.3t (ed-6+0.2t (ed-7 3.8 T rm can also be found in CIBSE KS16 or TM52. The maximum desired internal temperature is T max = 0.33 T rm + 21.8 for normal new school buildings. This is based on the understanding that the target comfort temperature T comf =0.33T rm +18.8, and T max = T comf + (acceptable range for building type and use, which is 3K for new school buildings. The following is a brief summary of the three criteria: 2.8.17.10 Criterion 1 is that the number of Hours of Exceedance must be no more than 40 when the predicted operative temperature exceeds T max by 1K, or more, during the five summer months (May-September. (c.f. number of hours above 28 C <120 in BB101. 2.8.17.11 Criterion 2 is the sum of the Weighted Exceedance (W e for each degree K above T max (1K, 2K and 3K on any one day. W e = Σh e x wf = (h e0 x 0 + (h e1 x 1 + (h e2 x 2 + (h e0 x 3, where the weighting factor wf=0 if ΔT 0, otherwise wf = ΔT, h ey = time in hours when wf = y, and ΔT = (T op T max, rounded to a whole number (i.e. for ΔT between 0.5 and 1.5 the value used is 1 C, for 1.5 to 2.5 the value used is 2 C and so on These three criteria are difficult to measure in a building. Therefore, a different criterion has been selected against which the performance of the building will actually be assessed during use. 2.8.17.17.1 Performance in Use (Effectively Criterion 4, which must be met is that the Contractor shall ensure that the design for New Buildings and for refurbished buildings achieves an acceptable standard of thermal comfort in each teaching space over the year. The Contractor shall demonstrate within spaces that are occupied for more than 30 minutes at a time that, during the Required Period, the average internal air temperature does not exceed the average external air temperature by more than 5ºC, both temperatures being averaged over the time period when the external air temperature is 20ºC, or higher. However, Service Failure or Unavailability Deductions will only apply when the diurnal temperature range (lowest temperature from the previous night to the maximum daytime temperature the following day exceeds 4ºC. Thermal comfort - occupants There is much more emphasis on the conditions in the space being comfortable, in particular the importance of mitigating cold draughts. There is now a requirement for pre-mixing of outdoor air, which rules out simple openings close to the occupant, which then leaves MVHR or e-stack. MVHR is penalised by the requirement for more outside air to meet the new lower CO 2 restrictions, which results in higher energy consumption over the year compared with e-stack. 2.8.17.12 Criterion 3 is that the predicted operative temperature should not exceed the T max by 4K or more at any time, i.e. T upp = maximum value of ΔT = 4 (c.f. ΔT<5 C and T max = 32 C in BB101

04 05 Priority Schools Output Specification Challenge Breathing Buildings Solution Priority Schools Output Specification Challenge Breathing Buildings Solution 1.5.6 Page 21 The health and comfort needs of pupils and staff are recognised through providing a healthy working environment that encourages self-esteem and motivation. Good schools understand the connection between children s physical and mental health and their educational achievement. The Generic Design Brief therefore requires an effective healthy indoor environment to support educational attainment with good daylight, ventilation, thermal comfort and acoustics. 2.6.1.1.5 Page 46 Optimising the benefits of daylight and natural, hybrid or mixed-mode ventilation. 2.6.1.2 Page 46 The Contractor shall ensure that the Building Services and components of the Building are well coordinated, work well in full use and are easy to operate. The users should be able to easily adjust or operate components that affect their comfort, such as lighting switches, ventilation controls and opening windows. Wherever possible, systems should default to off. 2.7.11.7 Page 54 The Contractor shall ensure that windows, vents and shading are designed and constructed to: 2.7.11.7.1 Provide sufficient light and natural ventilation. 2.8.16.3 Page 74 In naturally ventilated spaces, the Contractor shall provide mixing of ventilation air with room air to avoid cold draughts in the occupied zone during wintertime. In wintertime the minimum temperature of air delivered to the occupied zone at 1.4m above floor level shall be not more than 5 C below the normal maintained air temperature given in paragraph 2.8.19.1. 2.8.17.1 Page 74 The Contractor shall design the Building so as to limit the maximum internal temperature. The Contractor shall assess its design for overheating using the most relevant weather files from CIBSE s Summer Design Reference Years. 2.8.17.2 Page 74 The Contractor shall ensure that mechanical ventilation is not the sole method of summer-time ventilation in occupied spaces and that the occupied space should wherever possible also have opening windows or vents, with an effective opening area equal to at least 5% of floor area. The Contractor should also provide controls in each room to switch the mechanical ventilation on or off as required. 2.8.17.14 Page 77 The Contractor shall employ passive measures, such as thermal mass with night ventilation and external shading, where possible to reduce the possibility of overheating. Breathing Buildings provides controlled natural ventilation systems which ensure that teaching spaces are always provided with the necessary amounts of fresh air to ensure high air quality is maintained. The systems also ensure that the spaces are kept comfortable in terms of temperature by maximising the benefits of free cooling in summer, and using the patented e-stack concept to maximise the internal heat gains and deliver warm conditions in winter with the lowest heating use in the natural ventilation industry. On noisy sites we also provide acoustic attenuators which fit within the shafts of the natural ventilation system. The Breathing Buildings range of e-stack equipment and standard dampers, window actuators and controls helps contractors avoid mechanical ventilation in nearly all areas of a school. All Breathing Buildings systems have an interface which is easy to use. The system can be turned on/off and into purge mode as required by the room users. Breathing Buildings equipment is all about natural ventilation. The range of products is there to ensure sufficient natural ventilation is provided at all times of the year, and without cold draughts or excessive heating bills. The Breathing Buildings e-stack range of natural ventilation equipment is the only robust solution available to pre-mix the incoming cold fresh air in winter and minimise the risk of cold draughts. Opening windows or vents simply dump cold air in winter. The Breathing Buildings unique engineering team undertake dynamic thermal modelling calculations for every space for which we provide equipment. The modelling is undertaken using our own 4DFlo software which has been developed by academics from the University of Cambridge. We also use IES to support design teams if this is desired. Breathing Buildings provides natural ventilation systems which work in conjunction with mechanical systems. We provide a unique solution to the industry by delivering hybrid ventilation systems where purely natural ventilation schemes can t work, such as particularly deep-plan classrooms with no access to the roof or an atrium. All Breathing Buildings natural ventilation systems include a finely controlled night cooling mode which enables any thermal mass within a building to be exploited for cooling purposes in the summer. 2.8.21 Page 83 Ventilation of densely occupied spaces, such as classrooms, needs careful consideration as raised carbon dioxide levels have been shown to significantly reduce educational performance. 2.8.21.2.1 Page 84 The Contractor shall ensure that where natural ventilation is used, the system is capable of providing enough fresh air so that the average concentration of carbon dioxide during the Required Period is less than 1500ppm and so that the maximum concentration does not exceed 2000ppm for more than 20 minutes each day. 2.8.21.3 Page 84 The Contractor shall endeavour to design natural, mechanical or hybrid ventilation systems to meet the space heating and thermal energy targets given in the Energy and Utilities paragraphs of the FOS. 2.8.21.4 Page 84 The Contractor should also incorporate thermal mass and night cooling into the design where necessary to prevent summertime overheating. 2.8.21.6 Page 84 The Contractor shall maintain the required ventilation during room dim-out / blackout, and it shall not be impaired by security or safety requirements. The Contractor shall ensure that when outside air is introduced into a teaching space ventilation air and room air will be mixed to avoid cold draughts during wintertime. In wintertime the minimum air temperature of air delivered to the occupied zone at 1.4m above floor level shall be not more than 5 C below the normal maintained air temperature given in paragraph 2.8.19.1 2.8.21.7 Page 84 The Contractor shall ensure that the control of natural ventilation systems in densely occupied spaces such as classrooms is provided by means of an indoor air quality or carbon dioxide sensor that provides a clear and easily understood indication of indoor air quality to alert the teacher and possibly the pupils to the need to increase the ventilation by opening windows or vents; or an indoor air quality or carbon dioxide sensor linked to a ventilation system or an automatic window or vent opening system. 2.8.21.8.1 Page 84 The Contractor shall ensure that all ventilation systems are capable of dealing with localised conditions and responding to changes in demand. The consulting engineering team at Breathing Buildings is comprised of engineers from Cambridge University with PhDs and Masters degrees. Our team works closely with contractors and design teams to develop the most appropriate ventilation strategy for each teaching space. We model the ventilation requirements for all teaching spaces based on the occupancy profiles at design stage, and size the equipment accordingly. In addition, the systems we provide always include room CO 2 sensors. The Breathing Buildings control systems use this information to ensure that the dampers are adjusted to deliver the required amount of fresh air. The patented e-stack range is the only natural ventilation system available which reduces energy consumption whilst at the same time minimising the risk of cold draughts. Breathing Buildings also provides a patented integrated heating and ventilation controller to minimise the heating energy used in a building. The controller first ensures that the ventilation system never fights the heating system, but in addition, uses a regulating algorithm so that the energy use of the heating system is minimised. All Breathing Buildings natural ventilation systems include a finely controlled night cooling mode which enables any thermal mass within a building to be exploited for cooling purposes in the summer. The Breathing Buildings e-stack range of equipment is the only robust solution available to pre-mix the incoming cold fresh air in winter and minimise the risk of cold draughts. Opening windows or vents simply dump cold air in winter. Every Breathing Buildings natural ventilation system includes a number of temperature and CO 2 sensors. We monitor: The exterior temperature to assess whether it is acceptable to bring fresh air in directly onto occupants the interior CO 2 levels to determine the fresh air requirements in terms of air quality the room temperature to determine whether more than the minimum fresh air rate is needed to help cool the space the temperature of the mixed air in winter mode to determine the mixing ratio which the e-stack units need to achieve to mitigate the risk of cold draughts. Every Breathing Buildings natural ventilation system includes a number of temperature and CO 2 sensors. We monitor: a the exterior temperature to assess whether it is acceptable to bring fresh air in directly onto occupants. b the interior CO 2 levels to determine the fresh air requirements in terms of air quality. c the room temperature to determine whether more than the minimum fresh air rate is needed to help cool the space. d the temperature of the mixed air in winter mode to determine the mixing ratio which the e-stack units need to achieve to mitigate the risk of cold draughts.

06 07 E-Stack System for the PSBP Fingerblock School In response to the release of the Facilities Output Specification for the Priority Schools Building Programme, Breathing Buildings have used IES-VE software to model a low energy natural ventilation solution which will meet the requirements of the Output Specification. The Facilities Output Specification states that; 2.8.16.3 In naturally ventilated spaces, the Contractor shall provide mixing of ventilation air with room air to avoid cold draughts in the occupied zone during wintertime. In wintertime the minimum air temperature of air delivered to the occupied zone at 1.4m above floor level shall be not more than 5 C below the normal maintained air temperature. This functionality is provided by the e-stack system, which provides a lower energy alternative than a mixed mode system which operates in natural ventilation mode in the summertime (when the external temperature is greater than 16 C and switches to MVHR when the external temperature is below 16 C in order to prevent cold draughts. The fingerblock school is well suited to the e-stack atrium system. The rooms on the ground floor and the first floor will use A Series units which connect the classrooms to the central atria, providing a pathway for summertime upwards displacement ventilation and also allowing a mixing ventilation strategy for the wintertime. On the second floor, it is most effective to use a stack based system for summertime and wintertime ventilation strategies. Our R Series system works in conjunction with low level openings in the summertime and in the wintertime operates a mixing ventilation strategy, using low powered fans to mix warm room air with incoming, cold, external air. Some types of room are not suited to natural ventilation, such as landlocked server rooms etc. Also, small rooms such as single person offices have not been included in the e-stack strategy. The rooms which have been included are highlighted on the adjacent page. In order to demonstrate compliance with the Facilities Output Specification, Breathing Buildings have modelled the baseline building using the following parameters for the typical classroom; Our IES-VE modelling demonstrates that each room which uses the e-stack system will also meet the criteria for overheating, when simulated using the Manchester DSY weather file. For more extreme weather files such as London DSY it is necessary to reduce internal gains in order to meet the overheating criteria, for example by reducing the glazing G-value to around 0.32. 2.8.17.10 Criterion 1 - Hours of Exceedence (H e 2.8.17.11 Criterion 2 - Daily Weighted Exceedance (W e 2.8.17.12 Criterion 3 - Upper Limit Temperature (T upp Occupancy (people 32 Occupancy Heat Gain (W/person 75 9am - 12pm Occupied Hours 1pm - 4pm Lighting (W/m 2 10 Additional Small Power (W 1,000 Low Level Opening Effective Free Area 0.5m 2 per std window Glazing G-value 0.64 Heating Setpoint Classrooms 21 C Heating Setpoint Class Pre-heat 18 C Heating Setpoint Atria 18 C U-value of Walls (W/m 2 K 0.35 U-value of Roof (W/m 2 K 0.25 U-value of Floor (W/m 2 K 0.25 U-value of Windows (W/m 2 K 2.2 Infiltration (ach 0.25 Thermal Mass 100mm exposed concrete soffit The e-stack system is the low energy solution for compliance with the Facilities Output Specification. In the summertime the system uses buoyancy and wind with fan boost and night cooling modes where required. In the wintertime, the two low energy fans in the units use a maximum of 50W each which is many times lower energy than the fans used by heat recovery devices. The e-stack units ensure that during occupied hours in winter, the warm room air is used to temper the incoming air, so that additional heating is not required in the space until external temperatures drop below around 7 C. Ground Floor First Floor Second Floor Breathing Buildings System The carbon emissions of a typical, highly glazed, South facing classroom from the Fingerblock School baseline design can be seen adjacent. RM2 is a ground floor room, Humanities is a first floor room and English 9 is a second floor room. MVHR System Atrium R Series room S Series room A Series room The Carbon emissions of the same rooms using MVHR can be seen in the chart below. In addition both systems have identical Equipment (15.63-30.05 Kg/m 2 and Lighting (13.13-27.88 Kg/m 2 loads, which have been omitted for clarity. Summary A review of the BSF schools found that although many of them were intended to be low energy, the heating bills are significantly higher than forecast. Furthermore, a number of them still overheat. The new PSBP Output Specification has been created to help overcome these issues. The Breathing Buildings unique approach to natural ventilation is the easiest and most robust way of meeting the new Output Specification thermal comfort and energy targets.

08 Proving it works We are proud of our understanding of natural ventilation and our ability to deliver low energy buildings with great internal environments. We have monitored many installations to make sure that they are ventilating properly and mitigating cold draughts. These charts show data from Linton Village College where we installed S Series units. Winter supply In winter it is important to manage the ventilation requirements with heating and thermal comfort. As you can see from Figure 01 even when the outside temperature is below 5 C we are able to successfully mitigate cold draughts with the supply temperature remaining at a comfortable level. Figure 02 looks at the daily average CO 2 levels in the space during the winter months, which BB101 and the EFA Facilities Output Specification require to be below a daily average of 1,500ppm. The Breathing Buildings system delivers this using CO 2 sensors in the space and our patented winter mixing system. Independent research of our competitor systems has shown that without a draught mitigation strategy occupants simply turn the system off in winter, the space does not ventilate and CO 2 rises significantly. Figure 01 Modelling We are often asked what IES shows for natural ventilation and alternative ventilation strategies. The short answer is the e-stack system provides significant energy savings not just compared with traditional natural ventilation but also with MVHR, as shown in Figures 03 and 04. But don t take our word for it, let us help you to model your classroom with different ventilation strategies using IES. Figure 02 Figure 03 Figure 04 Get In Touch Visit our website www.breathingbuildings.com for more details or go to a specific page using the QR codes below: Breathing Buildings The Courtyard, 15 Sturton Street, Cambridge CB1 2SN Projects Products Downloads Tel: +44 (0 1223 450 060 Fax: +44 (0 1223 450 061 Email: info@breathingbuildings.com