centro ricerche-sviluppo e laboratori prove Date received: 13/02/15 Date of issue: 05/03/15 33048 S. Giovanni al at. UD KUBIKOFF S.R.L. VIA PISAA, 80 - LOC. LE GRILLAIE 50021 BARBERIO DI VAL D'ELSA (FI) Report consists of 8 test reports. Defects before testing: one Sample name: SLICE DIMPLE CLOSED CHAIR SAMPLE 190761 Overall dimensions: 525 x 575 x 865 (h) mm List performed tests: 1. Seat and back static load test E 1728:2012+AC:2013 2. Vertical load on back rest E 1728:2012+AC:2013 3. Seat and back fatigue test E 1728:2012+AC:2013 4. Seat front edge durability test E 1728:2012+AC:2013 5. Leg forward static load test E 1728:2012+AC:2013 6. Leg sideways static load test E 1728:2012+AC:2013 7. Seat impact test E 1728:2012+AC:2013 8. Back impact test E 1728:2012+AC:2013 Page 1 of 2
33048 S. Giovanni al at. UD Sample weight: ot determined Sample name: SLICE DIMPLE CLOSED CHAIR SAMPLE 190761 Side view Rear view Bottom view report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be Page 2 of 2
33048 S. Giovanni al at. UD 190761 / 1 Date of test: 16/02/15 VIA PISAA, 80 - LOC. LE GRILLAIE! 50021 BARBERIO DI VAL D'ELSA (FI)! Seat and back static load test E 1728:2012+AC:2013 Seat and back static load test, clause 6.4 Seat load! Back force! umber! of cycles 2.000 620 10 o defects ote: According to E 1728:2012, back force has been reduced from 700 to 620 to avoid tipping. Seat front edge static load, clause 6.5 Seat load! umber! of cycles 1.600 10 o defects ote: The test has been carried out according to table 1 of E 16139:2013, level L2 - extreme.
33048 S. Giovanni al at. UD 190761 / 2 Date of test: 16/02/15 VIA PISAA, 80 - LOC. LE GRILLAIE! 50021 BARBERIO DI VAL D'ELSA (FI)! Vertical load on back rest E 1728:2012+AC:2013 Vertical static load on back rest clause 6.6 Seat! load! Downwards! force! umber of! applications 1.800 900 10 o defects ote: The test has been carried out according to table 1 of E 16139:2013, level L2 - extreme.
33048 S. Giovanni al at. UD 190761 / 3 Date of test: 19/02/15 VIA PISAA, 80 - LOC. LE GRILLAIE! 50021 BARBERIO DI VAL D'ELSA (FI)! Seat and back fatigue test E 1728:2012+AC:2013 Seat and back fatigue test, clause 6.17 Seat force! Back force! umber! of cycles 1.000 300 200.000 o defects ote: The test has been carried out according to table 1 of E 16139:2013, level L2 - extreme.
33048 S. Giovanni al at. UD 190761 / 4 Date of test: 27/02/15 VIA PISAA, 80 - LOC. LE GRILLAIE! 50021 BARBERIO DI VAL D'ELSA (FI)! Seat front edge durability test E 1728:2012+AC:2013 Seat front edge durability test clause 6.18 Points of! application Seat force! umber of! cycles 100 mm back from! the front edge 800 100.000 o defects ote: The test has been carried out according to table 1 of E 16139:2013, level L2 - extreme.
33048 S. Giovanni al at. UD 190761 / 5 Date of test: 05/03/15 VIA PISAA, 80 - LOC. LE GRILLAIE! 50021 BARBERIO DI VAL D'ELSA (FI)! Leg forward static load test E 1728:2012+AC:2013 Leg forward static load test clause 6.15 Forward! horizontal force! Balancing! seat force! umber! of cycles 620 1.800 10 o defects ote: The test has been carried out according to table 1 of E 16139:2013, level L2 - extreme.
33048 S. Giovanni al at. UD 190761 / 6 Date of test: 05/03/15 VIA PISAA, 80 - LOC. LE GRILLAIE! 50021 BARBERIO DI VAL D'ELSA (FI)! Leg sideways static load test E 1728:2012+AC:2013 Leg sideways static load test clause 6.16 Sideways! horizontal force! Balancing! seat force! umber! of cycles 640 1.800 10 o defects ote: According to E 1728:2012, horizontal force has been reduced from 760 to 640 to avoid tipping. The test has been carried out according to table 1 of E 16139:2013, level L2 - extreme.
33048 S. Giovanni al at. UD 190761 / 7 Date of test: 05/03/15 VIA PISAA, 80 - LOC. LE GRILLAIE! 50021 BARBERIO DI VAL D'ELSA (FI)! Seat impact test E 1728:2012+AC:2013 Seat impact test clause 6.24 Mass of! impactor! kg Height! of drop! mm umber! of drops 25 300 10 o defects ote: The test has been carried out according to table 1 of E 16139:2013, level L2 - extreme.
33048 S. Giovanni al at. UD 190761 / 8 Date of test: 05/03/15 VIA PISAA, 80 - LOC. LE GRILLAIE! 50021 BARBERIO DI VAL D'ELSA (FI)! Back impact test E 1728:2012+AC:2013 Back impact test clause 6.25 Angle! Mass of! impactor! kg umber! of cycles 48 6,5 10 o defects ote: The test has been carried out according to table 1 of E 16139:2013, level L2 - extreme.