REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours



Similar documents
This qualification has been reviewed. The last date to meet the requirements is 31 December 2022.

REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE

Session 2: Hot Water Supply

What to Expect From the Examination. How to Study the Plumbing Codes

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Qualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation

New Zealand Certificate in Plumbing (Level 4)

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

HEAVY DUTY STORAGE GAS

STANDARD PLUMBING AND DRAINAGE REGULATION 2003

A guide to plumbing, drainlaying, and gasfitting that does not require a building consent. Superseded. Building Act 2004.

your water pressure explained

2010 Residential Water Heater Replacement Check List

Element D Services Plumbing

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

When Should Examination Preparation Begin?

6. Principles of effective plumbing systems

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

UNDERSTANDING CENTRAL HEATING SYSTEMS

12. Design of plumbing systems for single dwellings

Job Ready Assessment Blueprint. Plumbing. Test Code: 3061 / Version: 01

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

CERTIFYING DRAINLAYER

PLUMBING ROUGH IN INSPECTION

WHITE PLAINS PLUMBING CODE PART 1. GENERAL REQUIREMENTS

Plumbing for retail food businesses

Vaillant s plain English guide to. simple, concise and precise

Assembly and instructions

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

DEALING WITH PLUMBING AND HEATING EMERGENCIES

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

Plumbing Code Sections For Commercial Food Facilities

CHAPTER 26 PLUMBING CODE

Water Supply (Water Fittings) Regulations 1999

CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System

OWNER S MANUAL & INSTALLATION GUIDE. Installation Details Owner s Information Warranty. 80L - 400L Electric Storage Water Heaters

Plumbing Apprenticeship Program Curriculum

SIZING OF WATER PIPING SYSTEM

Introduction to Water Pipe Sizing

Proposed plumbing system within units at the Bluewater Hotel, 10 West Quay, Ahuriri, Napier

Link-Up. Solid Fuel Association Guide to Central Heating.

Australian/New Zealand Standard

Georgia State Amendments to the International Plumbing Code

Builder Specifications for Solar Ready Homes

Residential Plumbing BCN 1058

The Plumbing Pipeline

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

Approved courses for licences and licence endorsements detailed in the Plumbing and Drainage Regulation 2003 (Qld) Licences

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

Compliance Document for New Zealand Building Code Clause G13 Foul Water Second Edition

INSTALLATION INSTRUCTIONS & OWNERS GUIDE

Division A. Compliance, Objectives and Functional Statements

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

Boiler & Pressure Vessel Inspection discrepancies and failures

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Premier Plumbing & Gas

CHAPTER 11 STORM DRAINAGE

Please also see 10 golden rules for correct Saniflo installation on

Oregon Administrative Rules, Chapter Compilation- Building Codes Division DIVISION 695

Plumbing Identification and Damage Assessment Guide

The Plumbing Pipeline

CHAPTER 11 STORM DRAINAGE

Arapahoe County Residential Water Heater Installation and Inspection Guide

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

Additional Services Agreement. Part 3: Schedule of our requirements

Assessment Blueprint PHCC Educational Foundation Plumbing Year 2

Chapter 7 Plumbing Connections

16. Storm water drainage

HOT WATER HEAT PUMP MANUAL FOR ADVICE, REPAIRS AND SERVICE: CALL (AUSTRALIA) (NZ)

Electric Instantaneous. Water Heaters. Service manual

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

GUIDELINES FOR OPERATORS OF MOBILE FOOD BUSINESSES: DESIGN, CONSTRUCTION

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

Does Wall Township require an inspection by the building department on resale of a home?

Acumen Enterprises, Inc.

Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References

Plumbing Code in Commercial Kitchens

Owner s Manual. & Installation guide. Installation Details Owner s Information Warranty. 4 Star Gas Hot Water Heater

Itho Products for Hot and Boiling water. product-

Plumbing & Gasfitting

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

foundation designed to keep water out of the basement.

later damage - Loss ControL

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES

TEXAS STATE BOARD OF PLUMBING EXAMINERS EXAMINATION AND REGISTRATION Endorsement Training Programs

Instructions for designing heating systems.

Home Inspection Report

PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Transcription:

Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, JUNE 009 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE hours Check that the Candidate Code Number on your admission slip is the same as the number on the label at the top of this page. Do not start writing until you are told to do so by the Supervisor. Total marks for this examination: 00. The pass mark for this examination is 60 marks. Write your answers and draw your sketches in this booklet. If you need more paper, use the blank pages at the back of this booklet. Clearly write the question number if any of these pages are used. All working in calculations must be shown. Candidates are permitted to use the following in this examination: Drawing instruments, approved calculators The following are NOT permitted in the examination room: Any publications, Acts, Regulations, Codes of Practice, or Standards Check that this booklet has all of 5 pages in the correct order and that none of these pages is blank. YOU MUST HAND THIS BOOKLET TO THE SUPERVISOR AT THE END OF THE EXAMINATION Plumbers, Gasfitters and Drainlayers Board, 009. All rights reserved. No part of this publication may be reproduced by any means without the prior permission of the Plumbers, Gasfitters and Drainlayers Board.

QUESTION (a) State where an isolating transformer or residual current device (RCD) should be connected in order to provide electrical safety protection. ( mark) (b) A trench is to be dug.700m deep. State SIX safety measures, excluding personal protection equipment (PPE), that could be taken to protect workers when working in the trench. 3 4 5 6 (6 marks) (c) The New Zealand Building Code G/AS gives maximum temperatures at which hot water may be discharged when serving sanitary fixtures used for personal hygiene. State this temperature for: (i) schools, old people s homes and early childhood centres (ii) domestic dwellings. ( mark) Total 8 marks Plumbing 99, June 009

QUESTION (a) The temperature and pressure relief valve on a domestic hot-water cylinder is releasing steam. (i) State what action should be taken immediately. (ii) Give a possible cause of this condition. (b) A water heating system is required to heat water for both a radiator heating system and a potable hot water supply. State the type of system that must be used. ( mark) (c) Explain the following terms in relation to a hot water system that uses a plate heat exchanger. (i) Primary flow: (ii) Secondary flow: Plumbing 99, June 009

QUESTION (cont d) (d) The starter drawing below is of a free outlet (push through) hot water service supplying hot and cold water to a sink. The capacity of the hot water cylinder is 0 litres. Both hot and cold water are to discharge through the centre spout over the sink bowl. Complete the hot and cold water service and label all relevant points. Hot tap Spout Cold tap Inlet Outlet Cold water supply (3 marks) Total 8 marks Plumbing 99, June 009 3

QUESTION 3 (a) State the THREE requirements a person must meet to become registered with the Plumbers, Gasfitters and Drainlayers Board as a registered plumber. 3 (3 marks) (b) Give TWO occasions when a plumber must give 4 hours notice to any Territorial Authority regarding plumbing installations. Plumbing 99, June 009 4

QUESTION 3 (cont d) (c) A solid fuel space heater is to be installed. State FOUR New Zealand Building Code requirements that must be met regarding the installation. 3 4 (4 marks) (d) State when it is necessary to provide overflow outlets to roof gutters. ( mark) (e) Complete the following Functional Requirement as stated in the New Zealand Building Code Clause G3 Foul Water. Functional Requirement Buildings in which sanitary fixtures and sanitary appliances using waterborne waste disposal are installed must be provided with an adequate plumbing and drainage system to ( mark) Total marks Plumbing 99, June 009 5

Question 4 (a) A pump is to be installed in the basement of a two-storey dwelling. The pump is to supply water to the upper floor of the dwelling from a water supply below the level of the pump. Give FOUR items of information required when selecting the pump. 3 4 (4 marks) (b) A hydro-pneumatic pressure system installed in a domestic situation has a waterlogged pressure vessel. (i) State the probable effect this will have on the system. (ii) State what action is required to remedy the situation. (c) A new 00mm potable water main has been installed. List TWO procedures that must be carried out on the water main before the supply is put into service. Plumbing 99, June 009 6

QUESTION 4 (cont d) (d) A plumber has arrived at an occupied apartment block to carry out repairs to the metallic water main. It is necessary for the plumber to cut through a section of the main. After having exposed the main, list FOUR steps the plumber should carry out before cutting the pipe. 3 4 (e) An open-vented low pressure water system is being installed. State TWO ways in which the performance of the system will be affected if it does not have the correct hydraulic gradient. (f) A well is one form of water supply. Give the essential feature of the following wells. (i) Deep well (ii) Shallow well Total 4 marks Plumbing 99, June 009 7

QUESTION 5 (a) (i) Explain how electrolysis occurs. (ii) State an effect of electrolysis. (3 marks) (b) Describe the following physical properties of plumbing materials. (i) Ductility: (ii) Conductivity: (iii) Malleability: (iv) Tenacity: (v) Fusibility: (5 marks) (c) Explain what is meant by the term ambient temperature. ( mark) Total 9 marks Plumbing 99, June 009 8

QUESTION 6 (a) A cylindrical supply tank is to pass through a 500mm square ceiling opening. The tank is to have a capacity of 80 litres. A clearance of 5mm is to be allowed on each side of the tank within the opening. Calculate the height of the tank. Show all working to three decimal places. Formula: V = 0.7854 D² H where V = Volume D = Diameter H = Height (3 marks) Plumbing 99, June 009 9

QUESTION 6 (cont d) (b) A cylindrical tube is to be constructed from a flat sheet. The tube is to be 400mm in diameter and.00m in length. A 0mm allowance is to be made for the seam. Calculate the area of sheet metal required. Show all working to three decimal places. Formula: C = π D where C = Circumference D = Diameter Plumbing 99, June 009 0

QUESTION 6 (cont d) (c) A hydraulic ram is supplied with 30 litres of water per hour. The head of water on the inlet side of the ram is 3.500m. The ram must lift the water 6.000m to fill the tank. The efficiency of the ram is 55%. Calculate the quantity of water per hour delivered by the ram. Show all working to three decimal places. Formula: q = Q x h x e 00 x H where q = number of litres of water delivered per hour Q = number of litres of water flowing to the ram per hour h = head on inlet side of ram in metres e = efficiency of ram (%) H = height to which water is raised in metres Total 7 marks Plumbing 99, June 009

QUESTION 7 Name the THREE types of view of a building that may be shown on a set of building plans. 3 Total 3 marks Plumbing 99, June 009

QUESTION 8 (a) A heating and ventilation system is to be installed in a building. List FOUR factors used to determine the number of air changes per hour that are required. 3 4 (4 marks) (b) A reliable supply of dust-free air is not available for a ducted supply-air ventilating system. State what should be done to rectify the situation. (c) State TWO advantages of a mechanical inlet and natural return air supply system. (d) State the effect of a clogged air filter on a ventilation system. ( marks) Total 9 marks Plumbing 99, June 009 3

QUESTION 9 The drawings below show a square to square transition. On the page opposite, develop the pattern from the information provided by using the triangulation method. Use the line AB drawn to start the development. Vertical height A/ B/ D C 4 3 Seam A B Total 5 marks Plumbing 99, June 009 4

B A Plumbing 99, June 009 5

QUESTION 0 (a) A valve train is fitted to the supply line for a mains pressure hot water cylinder. A cold water expansion (relief) valve is to be fitted in the valve train. State TWO requirements that must be met when determining the pressure rating for the valve. (b) State the purpose of a pressure limiting valve in the cold water supply line to a mains pressure hot water cylinder. ( mark) (c) Give TWO reasons for fitting a cold water relief valve to a mains pressure hot water cylinder. Plumbing 99, June 009 6

Question 0 (cont d) (d) State TWO installation factors that must be considered when installing cold water expansion valves and temperature-pressure relief valves. (e) Name TWO types of valve that can be used to control the cold water supply pressure to a hot water cylinder. ( mark) (f) Multiple water heaters are to be installed in parallel. State TWO requirements the pipework must meet in relation to water flow. Total 0 marks Plumbing 99, June 009 7

QUESTION (a) Water seal loss in a sanitary fixture trap may be caused by momentum. Explain how this occurs. (b) Water seal loss in a sanitary fixture trap may be caused by oscillation. Explain how this occurs. (c) State the minimum performance requirement of any urinal flushing apparatus. ( mark) Total 5 marks Plumbing 99, June 009 8

Question (a) Explain the term break tank in relation to plumbing. ( mark) (b) Draw the side elevation of an above ground water meter installation and name all the components. Indicate the direction of flow and ground level. (4 marks) Plumbing 99, June 009 9

Question (cont d) (c) Using drawing equipment, draw a schematic diagram of a testable double check valve backflow prevention device. Show all test points to enable full testing of the device. Clearly label all components. (3 marks) (d) Using drawing equipment, draw a line drawing of a vacuum column suitable for back flow protection. Show the relevant measurement. ( mark) Plumbing 99, June 009 0

Question (cont d) (e) State TWO methods of preventing backflow from a sanitary fixture in a domestic dwelling. Total marks Plumbing 99, June 009

This page is available for additional working or answers Question number Plumbing 99, June 009

This page is available for additional working or answers Question number Plumbing 99, June 009 3

This page is available for additional working or answers Question number Plumbing 99, June 009 4

This page is available for additional working or answers Question number Plumbing 99, June 009 5

For Examiner s use only Question number Marks Marks 3 4 5 6 7 8 9 0 Total