Application Note Sensors and Flexible Heaters in Sleep Apnea Machines



Similar documents
Airflow Sensors Line Guide

humidity sensors Line Guide FEATURES Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH7000 Series, HIH8000 Series

Medical Applications. Sensing and Control. Sensors and Switches for Potential Medical Applications

Medical Applications. sensing and control. Thermal Management Solutions

HIH-4000 Series Humidity Sensors

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH8000 Series ±2.0 %RH Accuracy. Datasheet

Medical Applications SENSING AND CONTROL. Sensor and Switch Solutions

FEATURES Temperature-compensated magnetics Miniature plastic package Low voltage: 3.8 V operation

Honeywell Pressure Switches Line Guide

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Speed Sensors Line Guide

Heavy Duty Pressure Sensors/ Transducers Line Guide

Industrial VRS Magnetic Speed Sensors

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

General Purpose Thermal Mass Flowmeter Model 4140/4143

OEM-EP Pressure Controllers

The PACE5000 Modular Pressure Controller/Indicator

Fiber Optics and Liquid Level Sensors Line Guide

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Subminiature Load Cell Model 8417

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Temp. & humidity Transmitter Instructions

PRODUCT PROFILE FEATURES

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

SEMICONDUCTOR TECHNICAL DATA

Industrial Semi Metal USB

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Application Information Improving Efficiency in Smart Grid Applications With Fully Integrated Current Sensing ICs

, User s Manual

User Manual THR840DUK Digital Thermostat

Duct Humidity Transmitter

Design Challenges for Adding Relative Humidity Sensors

Application Note for SDP600 and SDP1000 Series Measuring Differential Pressure and Air Volume with Sensirion s CMOSens technology

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Precision Mass Flow Metering For CVD Applications.

Mass Flow Meters & Controllers

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

SMART SENSOR COLLECTION

Typical Aluminum GFM Mass Flow Meter

How To Power A Power Control Microprocessor (Power Control) Microprocessor 2 (Power) (Power Power) (Control) (Repower) Microcontroller (Power/Reflow) (Mini) (Microprocessor) (Wired) (Wire

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Brushless DC Motor Controller Product Specification Assembly 025F0129

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Rackmount Intelligent Pressure Scanners

TEMPERATURE SENSORS AND PROBES FOR BIO-MEDICAL APPLICATIONS

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

Battery Powered Digital Mass Flow Meters for Gases

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

HVAC Processes. Lecture 7

Technical Note Series

Problem / Solution. The problem:

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Thermal Flow Sensor Die

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Asset Condition Monitoring Solutions

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

SDI Multi Sensor Module with Charger Enclosure Station Support

Aera Transformer Digital Mass Flow Products. Transform your process with greater flexibility and lower cost of ownership

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Accurate Air Flow Measurement in Electronics Cooling

PIEZOMETER AIRFLOW MEASURING RING

Gas sensors for greenhouse measurements

Models SFP33 & SFP32 Pressure Transmitters

INDUSTRIAL AUTOMATION EQUIPMENT EDITION

Fundamentals of Mass Flow Control

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

CQM1-SF200/CS1W-SF200

VSO MAX HP High Flow Proportional Valve

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Continuous flow direct water heating for potable hot water

Water Leak Detection System

Analog Servo Drive 25A8

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Battery Powered Thermal Mass Flow Meters for Gases

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

How is Dew Point Measured Reliably?

The Heartbeat behind Portable Medical Devices: Ultra-Low-Power Mixed-Signal Microcontrollers

Battery Powered Thermal Mass Flow Meters for Gases

DUST EMISSION MONITORING SYSTEM

Measuring Temperature withthermistors a Tutorial David Potter

HM1500LF Relative Humidity Module

Humidity Sensor. Model HU-224/225

Fossil fuel heating equipment

Transcription:

Background Sleep apnea is the repeated cessation of breathing during sleep, sometimes hundreds of times during the night and often for a minute or longer. If left untreated, sleep apnea can cause high blood pressure, cardiovascular disease, memory loss, and weight problems. Recent medical studies indicate that long-term sleep apnea may also increase the risk of dying of cancer. The resulting lack of restful sleep may also be responsible for job impairment and motor vehicle accidents. A main treatment option is the use of a Positive Airway Pressure (PAP) machine. (See Figure 1.) The patient wears a mask that uses pressure to send air flowing through the nasal passages so they don t collapse and cause breathing to cease. There are three main categories of PAPs (in order of complexity/cost): 1. CPAP (Continuous Positive Airway Pressure) provides a constant pressure to the patient. This positive pressure keeps the throat from collapsing during sleep and allows the patient to breathe freely without worry of episodes of non-breathing. 2. Auto-PAP (Automatic Positive Airway Pressure) measures the resistance in a patient s breathing. The amount of continuous pressure delivered to the patient is then automatically tuned to the minimum required to maintain an unobstructed airway on a breath-by-breath basis. Sleep apnea machine 3. Bilevel-PAP (Bilevel Positive Airway Pressure) provides two levels of pressure: IPAP (Inspiratory Positive Airway Pressure) and a lower EPAP (Expiratory Positive Airway Pressure). Solutions Honeywell manufactures many sensors and flexible heaters that may be used in sleep apnea machines. They are designed to help control airflow, pressure, humidity and temperature, and to provide output for smooth motor control. (See Figure 1.) 7 Room Air Air Filter Temperature Sensor Fan Control 5 4 Humidifier 1 Pump 2 Sensors LCD 1 2 3 4 5 Water 2 6 Backlight Sleep Apnea Machine Power 1 2 3 4 Airflow Sensors* Honeywell Zephyr TM HAF Series or AWM90000 Series (AWM92100V) Flexible Heater Assembly Humidity Sensors Honeywell HumidIcon TM HIH8000 Series, HIH9000 Series; HIH-5031/5032 Series, HIH-4030/4031 Series, HIH-4020/4021 Series, HIH-4000 Series, HCH-1000 Series Low Pressure Board Mount Pressure Sensors TruStability HSC Series, SSC Series 5 6 7 Figure 1. Potential Honeywell products used in sleep apnea machines Touch Screen Control Feedback and Monitors Discrete Thermistors 192 Series or 194 Series or Packaged Temperature Probes 500 Series Commercial Thermostats 2450RC Series Magnetic Sensor ICs SS400 Series * Typically there is only one airflow sensor per machine. Some customers place it before the blower and some after the blower. 1 Humidifier may be designed in house or puchased from a third party. 2 Some CPAP machines may not utilize a pump. Sensing and Control

Airflow Sensors These products monitor the patient s breathing and send an output that reduces the flow of the machine s internal blower fan when the patient starts to exhale. The resulting lowered resistance prevents the patient from feeling as though he is fighting against the machine when breathing, reducing discomfort. Machines that use airflow sensors to detect the breathing cycle are more comfortable for the patient and are more likely to be used regularly than equipment without this feature. Some insurance companies and doctors often prefer this equipment due to greater patient compliance. These sensors are used in Auto-PAP and Bilevel-PAP machines. Simplifies customer s production requirements: ASIC-based I 2 C digital output compatibility eases integration to microprocessors or micro-controllers, reducing PCB complexity and component count Small: Occupies less space on PCB, allowing easier fit and potentially reducing production costs; PCB size may also be reduced for easier fit into space-constrained applications Flexible: Low 3.3 Vdc voltage option and low power supply allows for battery-driven and other portable applications Honeywell Zephyr Digital Airflow Sensors (HAF Series) 10 SLPM to 300 SLPM ( = competitive differentiator) Honeywell Zephyr Analog or Digital Airflow Sensors (HAF Series) ±50 SCCM to ±750 SCCM ( = competitive differentiator) High 12-bit resolution (digital) or high 11-bit resolution (analog) increases the ability to sense small airflow changes, allowing for more precise control of the application Meet high accuracy specifications: High 2.5% accuracy allows for very precise airflow measurement, often ideal for demanding applications with high accuracy requirements Customizable: Allows the sensor to be designed to meet specific end-user needs High sensitivity at very low flows: Allows the customer s application to detect presence or absence of airflow High stability: Reduces errors due to thermal effects and null shift to provide accurate readings over time, often eliminating need for system calibration after printed circuit board mount, and periodically over time Low pressure drop: Low pressure drop typically improves patient comfort in medical applications, and reduces noise and system wear in components such as motors/pumps Saves customers time and money: Linear output provides a more intuitive sensor signal than the raw output of basic airflow sensors, often eliminating the need for customers having to linearize the output which can help to reduce production and design costs and implementation time 2 sensing.honeywell.com Industry s smallest Total Error Band (TEB) allows for precise airflow measurement, often ideal for demanding applications with high accuracy requirements High accuracy is ideal for use in demanding applications Fast response time allows the customer s application to respond quickly to airflow change, important in critical medical (e.g., anesthesia) and industrial (e.g., fume hood) applications High stability reduces errors due to thermal effects and null shift to provide accurate readings over time and often eliminating the need for system calibration after PCB mount and periodically over time High sensitivity at very low flows provides a fast response time at the onet of cessation of flow High 12-bit resolution increases the ability to sense small airflow changes, allowing customers to more precisely control their application Wide airflow range measures mass flow with standard flow ranges of 10 SLPM, 15 SLPM, 20 SLPM, 50 SLPM, 100 SLPM, 200 SLPM or 300 SLPM, or custom flow ranges, increasing the options for integrating the sensor into the application Choice of port styles (manifold mount, 22 mm OD tapered male fitting, and G 3/8 female threaded fitting) provide flexibility to choose the pneumatic connection that is best for the customer s application Linear output provides a more intuitive sensor signal than the raw output of basic airflow sensors, which can help

reduce production costs, design, and implementation time Wide supply voltage range: flexible regulated power circuit (3 Vdc to 10 Vdc) gives the designer the flexibility to choose the supply voltage that works best in the system ASIC-based I 2 C digital output simplifies integration to microprocessors or microcontrollers, reducing PCB complexity and component count Factory or custom calibration for multiple gas types: can be factory calibrated for many gases, such as dry air, helium (He), argon (Ar), nitrogen (N 2 ), nitrous oxide (N 2 O), and carbon dioxide (CO 2 ), or custom calibrated for the end customer, eliminating the need to implement gas correction factors RoHS-compliant materials meet Directive 2002/95/EC Custom Configurations Flat, molded-to-shape, spiral wrap, transparent, and hightemperature configurations Single, multiple or variable Watt densities designed to customize heat output Variety of manufacturing materials, including silicone and other flexible dielectric components Hall-Effect Sensor ICs The durable SS400 Series is designed to provide enhanced output accuracy for smooth motor control that reduces noise and vibration in motor assembly fan systems. AWM90000 Series AWM92100V Mass flow and low differential pressure sensing Sensitivity to low flows (0.1 SCCM to 200 SLPM) Cost effective Low power consumption Analog output Enhanced response time Unamplified Non-compensated (external customer-supplied bypass needed) Flexible Heater Assembly Moisture introduced into the air stream is generated by either mist or heated vapor. This is often best accomplished by heating water to a vapor and introducing it into the air stream. This method often has an advantage over the misting method as it creates vapor, as well as heat. These flexible heaters are custom-designed to customer requirements. On-board sensors such as thermistor thermal links and electrical fuses are commonly added. Its small size often reduces replacement costs and allows for design into many compact, automated, lower-cost assemblies. A thermally-balanced integrated circuit that is accurate over a full temperature range is designed to provide proper fan functionality. SS400 Series Quad Hall-effect design minimizes effects of mechanical or thermal stress on output, and promotes a stable output Unipolar, bipolar or bipolar latching magnetics and customizable operate/release points provide application flexibility Negative compensation slope optimized to match negative temperature coefficient of lower-cost magnets, providing robust design over wide temperature range Band gap regulation promotes stable operation over supply voltage range Low power consumption enhances energy efficiency Honeywell Sensing and Control 3

HUMIDITY SENSORS These sensors may be used to deliver warm and moist air, which often enhances patient comfort. When introducing moisture into the air stream, it must be monitored and controlled. Honeywell s humidity sensors are installed either directly into the air stream or in a parallel branch. The sensor is coupled to a microcontroller designed to measure the humidity of the air stream and to interact with the controller that ensures the correct level of moisture is present. HIH8000 Series HIH9000 Series ( = competitive differentiator) Industry-leading long term stability (1.2 %RH over five years: - Minimizes system performance issues - Helps support system uptime by eliminating the need to service or replace the sensor during its application life - Eliminates the need to regularly recalibrate the sensor in the application, which can be inconvenient and costly Industry-leading reliability (MTTF 9,312,507 HR): Thermoset-polymer capacitive sensing element s multilayer construction provides resistance to most application hazards such as condensation, dust, dirt, oil, and common environmental chemicals, which help provide industryleading reliability. Lowest total cost solution: Delivers the lowest total cost solution due to the sensor s industry-leading combined humidity/temperature sensor Combined humidity and temperature sensor: Allows the RH measurement to be temperature compensated, and provides a second, standalone temperature sensor output; allows the user to purchase one sensor instead of two Energy efficient: - Low supply voltage: Can operate down to 2.3 Vdc, which allows use in low energy and wireless-compatible applications to enhance energy savings and prolong system battery life - Low power consumption: The sensor goes into sleep mode when not taking a measurement within the application, consuming only 1 μa versus 650 μa in full operation in a battery operated system; sleep mode 4 sensing.honeywell.com helps maximize battery life, reduces power supply size, and reduces the application s overall weight High resolution: High 14-bit humidity sensor resolution and 14-bit temperature sensor resolution within the application help the user s system detect the smallest relative humidity or temperature change True, temperature-compensated digital I 2 C or SPI output: Typically allows the customer to remove the components associated with signal conditioning from the PCB to free up space and reduce costs associated with those components (e.g., acquisition, inventory, assembly). True, temperature-compensated digital I 2 C or SPI output often eliminates problems that could occur from having multiple signal conditioning components across the PCB, as well as simplifies integration to the microprocessor, eliminating the need for customer-implemented, complex signal conditioning. Housing style: SOIC-8 SMD (Surface Mount Device) or SIP 4 Pin; ultra small size allows for flexibility of use within the application, occupies less space on the PCB, and typically simplifies placement on crowded PCBs or in small devices; industry standard design simplifies design-in Filter: Available with hydrophobic filter and condensationresistance, allowing for use in many condensing environments, or without hydrophobic filter, non-condensing Tape and reel: Allows for use in high volume, automated pick-and-place manufacturing, eliminating lead misalignment to the PCB and helping the customer to reduce manufacturing costs Wide operating temperature range: -40 C to 125 C [-40 F to 257 F] allows for use in many applications Optional one or two %RH level alarm outputs: Provides the ability to monitor whether the RH level has exceeded or fallen below pre-determined and critical levels within the application Multi-function ASIC: Delivers flexibility within the application by lowering or eliminating the risk and cost of OEM calibration RoHS and WEEE compliant, halogen-free

HIH-5030/5031 Series HIH-4030/4031 Series HCH-1000 Series Multilayer construction designed to provide enhanced resistance to wetting, dirt, and common environmental chemicals. Available covered, filtered/unfiltered for application flexibility Surface mount design Low current draw Factory calibration data designed to provide individuallymatched downstream electronics and accuracy. Voltage supply: HIH-5030/5031: 2.7 Vdc to 5.5 Vdc HIH-4030/4031: 4 Vdc to 5.8 Vdc Unbuffered capacitive output for a cost-effective solution Reduced temperature dependence Low hysteresis Long-term stability Enhanced sensitivity/response Pressure Sensors These sensors monitor the pressure delivered to the patient in all three PAP machine types. HIH-4020/4021 Series HIH-4000 Series Instrumentation-quality RH sensing performance in a competitively priced, solderable SIP Accurate, fast response Multilayer construction provides enhanced resistance to wetting, dirt, and common environmental chemicals Laser trimmed for stable, low drift performance Factory calibration data designed to provide individuallymatched downstream electronics and accuracy HIH-4020/4021 Series: Available covered/uncovered and filtered/unfiltered for application flexibility TruStability Board Mount Pressure Sensors (HSC Series and SSC Series) Temperature compensation and calibration provide an amplified signal, typically allowing removal of components associated with signal conditioning from the PCB, increasing space and reducing associated costs Industry-leading stability often eliminates need for calibration after PCB mount, and periodically over time Digital ASIC output in either I 2 C or SPI protocols from digital sensors accelerates performance through reduced conversion requirements and the convenience of direct interface to microprocessors and microcontrollers Multiple packaging, mounting, power, and signal options combine with customized calibration capabilities to increase flexibility Honeywell Sensing and Control 5

Temperature Sensors Discrete Thermistors: Air that is warm and moist helps to provide the patient with a comfortable breathing situation and may reduce sore throats caused by breathing cold, dry air. As such, the temperature of the air delivery system is often monitored and controlled to help ensure that the air stream is maintained at the desired level of warmth. The 192 Series and 194 Series are installed directly into the air stream, and are designed to monitor and control air temperature. The sensor is coupled to a microcontroller designed to monitor air stream temperature and interact with the controller which controls and regulates the temperature of the air stream. Honeywell offers several types of configurations. The packaged sensors are available as discreet components for customer-built assemblies, or Honeywell can provide a full assembly solution that the customer may simply pigtail into the system. Enhanced reliability, precision and stability allow the customer greater flexibility in temperature monitoring and control Wide operating temperature range of -60 C to 300 C [-76 F to 572 F] provides application flexibility Available in wide variety of housing styles and materials, R-T curves, mounting methods, mechanical interface, electrical interface and connector types to meet most application needs COMMERCIAL THERMOSTATS Bimetallic thermostats may be included in sleep apnea machines as on-board (stand-alone) devices on flexible heaters for temperature control without the need to add associated software or electronics. 2450RC Series 192 Series 194 Series Bare leads (192 Series) or insulated leads (194 Series) designed for improved application flexibility Resistance temperature (R-T) curve interchangeability designed to offer standardization of circuit components and simplification of design/replacement, as well as potential cost savings Small size often eases use in confined spaces Cost effective Custom operating temperatures and tolerances to fit customer-specific applications Wide variety of mounting brackets and terminals increase flexibility within the application Small product size allows enhanced response to temperature changes Packaged Temperature Probes: These small, easy to install probe assemblies support and position their thermistor elements within the media to be monitored as well as protect the thermistors against damage in use or handling. The assemblies also help direct thermal or fluid flow evenly across the thermistors for accurate temperature sensing. 500 Series 6 sensing.honeywell.com

Find out more To learn more about Honeywell s sensing and control products, call 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 008155-9-EN January 2014 Copyright 2014 Honeywell International Inc. All rights reserved.