713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.



Similar documents
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

MJK 713 Open Channel Flowmeter

Mobrey open channel flow measurement systems

2.24. Pump Controller 704. Data Sheet

Regards from the Team at Rheology Solutions.

Mobrey open channel flow measurement systems

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Configuring the HydroRanger 200 to measure open channel flow. Specific parameter setting to configure the following primary measurement devices:

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

O C M III. Open Channel Flow Monitor

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Electronic Control Devices The European Product Catalogue 2007

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

IFC 070 Technical Datasheet

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.

PRODUCT PROFILE FEATURES

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

Contents. Document information

3DLevelScanner II TECHNICAL DATA SHEET

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Series DFMT Digital Paddlewheel Flowmeter

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Inductive sensor NI10-M18-Y1X-H1141

Adjustment functions for both span and shift have been incorporated

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Rosemount 333 HART Tri-Loop

Centro-Matic Automatic Lubrication Systems System Controls

3500/62 Process Variable Monitor

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Digital inductive conductivity transmitter

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

S-series Mass Connection Solutions

For Multi-Parameter Meters see mvx

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Electronic Control Devices The European Product Catalogue 2007

and Accelerometers

Short information Parameters are programmed via front-side membrane keypad

Galvanic Parts Per Million Dissolved Oxygen Systems

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Technical Data Sheet. 3DLevelScanner

Thermal Mass Flow Meter (Series MST)

Open channel & partially filled pipe Ultrasonic flow meters

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Multifunction devices

Plastic tube flowmeters Series PT/PS

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Series 510 Submersible Level Transmitters

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

PIEZOMETER AIRFLOW MEASURING RING

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Steven R. McManus Environmental Product Support Teledyne Isco

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Rosemount 333 HART Tri-Loop

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Analog signal converters CC-E I/I Current / current isolators

Duct Humidity Transmitter

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

E-STOP relays, safety gate monitors

FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes

Agilent 4338B Milliohm Meter

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Subminiature Load Cell Model 8417

How To Use A Ds340 (Dsp)

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Micro Motion 3098 Gas Specific Gravity Meter

Buckeye Detection Systems Fixed Detection Systems Application Survey

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

PART 1 - INTRODUCTION...

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Power Supplies 3. SDN-P DIN Rail Series

Triple Waveband Infra-Red Flame Detection

Preset Counter signo 721

Product Specification instalert Rapid Messenger Variable Message Sign

Transcription:

and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the stated specifications and dimensions without prior notice.

General The measures the flow rate of water or wastewater in all types of weirs and flumes and provides a display of both current flow rate and totalized flow. The can be used with either ultrasonic or hydrostatic level sensors. Features Available with either Shuttle Ultrasonic Sensor, Hydrostatic Level Transmitter or with 4-20 ma input. High measuring accuracy in ranges from 0-4 in. to 0-10 ft. The 713 Flowmeter is calibrated from the front panel. Easy to operate with user dialogue in English or Spanish. Security access code prevents altering of settings and readout of recorded data. Backlit 2-line 48-character LCD display. No loss of settings from power interruption as all values are stored in an EEPROM. Indicates actual flow and average flow for the last hour, today and previous day. Totalizer for the last hour, today and 99 previous days. Alarms can be set for system failure, high and low flow and high volumes. Built-in power monitoring. Power failures are registered in the alarm log. Application The is commonly used for flow measurement in municipal and industrial sewage treatment plants, in fish farms and for flow measurement in streams and rivers, anywhere a weir or flume can be installed. Function The linearizes the signal from the sensor making it proportional to the flow rate by calculating the flow using one of the following methods: preprogrammed formulas for the most commonly used flumes and weirs, such as Parshall or Palmer-Bowlus flumes, V- notch weirs and rectangular weirs when using other flumes or weirs not preprogrammed, the exponent and factor for those primary devices may be entered to allow accurate measurement, e.g. Cipoletti weirs, trapezoidal flumes, etc. for flumes where no formula exists, a number of Q/h-values can be entered and level vs. flow is calculated Sensors Suitable for narrow channels; 7 beam angle. High resolution and accuracy from 0-4 in. to 10 ft. Easily adaptable to any weir or flume with standard mountings. Sensors are FM approved for use in Class 1 Div. 1 Groups A-G applications. Hydrostatic Level Transmitter Rugged construction with excellent stability. Standard 1 NPT threaded for pipe mounting. Easy to install in stilling wells, which is recommended when using a hydrostatic level transmitter in flowing water. 3400 series hydrostatic level transmitter is UL approved for use in Class 1, Div 1, groups A-D applications and ATEX approved for zone 1+2. 2

Ground 4 5 1 8 Data Sheet Dimensions 713 Flowmeter MJK 3400 Level Transmitter Universal bracket Sensor bracket, standard MNPT 5.31 1.26 Sensor bracket, short Dia.1.97 713U System Package 713U Flowmeter 713 with Standard cable length 39 ft. Special order longer cable lengths are available up to 150 ft. No. 1 = brown No. 2 = red No. 3 = orange No. 4 = yellow No. 5 = black Power supply Relay out 1 Relay out 2 Relay out 3 Relay out 4 Totalizer output Current output (0 / 4-20 ma) 713S System Package 713S Flowmeter 713 with ultrasonic sensor using Shuttle Level Transmitter as signal amplifier Power supply Shuttle Level Transmitter If the cable length between the ultrasonic sensor and the MJK 713 flowmeter exceeds 150 ft, a Shuttle Level Transmitter can be used as signal amplifier. 713P System Package 713P Flowmeter 713 with hydrostatic level transmitter Level Transmitter Max. 600 ohm loop resistance. When the 3400 sensor is installed in a hazardous area, a zener barrier or isolator has to be installed in the safe area. Zener barrier 202995 Safe area Power supply Relay out 1 Relay out 2 Relay out 3 Relay out 4 Totalizer output Current output (0 / 4-20 ma) 3

Specifications - one year warranty Measuring range: 0-1 ft., 0-3 ft., 0-10 ft. Frequency: 30 / 75 khz Beam angle: 3 / 7 Temperature range: - 5 to + 150 F Accuracy: ± 0.04 " Deadband: 14 " Dimensions: Dia. 4.06 ", height 4.17 " Materials: VALOX (reg. tm of General Electric Co.) Cable: Shielded, oil resistant PUR insulation, length 39 ft. Can be extended to 150 ft. using MJK 690010 cable. Enclosure: NEMA 6P, waterproof, withstands submersion up to 30 ft. Approvals: FM Class 1 Division 1 Groups A-G CE EN50081-1, EN50082-1 Model 3400 Hydrostatic Level Transmitter - one year warranty Temperature range: 15 160 F Temperature deviation, zero point: Better than ± 0.01 % / F Temperature deviation, full range: Better than ± 0.005 % / F Linearity / Stability: Better than ± 0.5 % FS Measurement accuracy: Better than ± 0.1 % FS @ 50 to 85 F Better than ± 0.2 % FS @ full temperature range. Long time stability: Better than ± 0.1% FS per year Materiale: Housing: PPS / Diaphragm: 99.9 % Al 2 O 3 / Measurement cell packing: Viton Supply voltage: 10-30 V DC (12-30 V DC for cable lengths above 315 ft.) Output: Two-wire 4-20 ma (passive transmitter) Cable: 2 AWG 20, shielded, oil resistant PUR insulation Cable length: 39 ft. Longer cable lengths available, consult the factory. Enclosure: NEMA 6P, withstands a static pressure equal to max. measuring range. Approvals: UL Class 1 Division 1 Groups A-D and ATEX Ex ia IIC T6 CE EN50081-1, EN50082-1 Can be delivered with other cable lengths on request. 713 Series Open Channel Flowmeter Measuring ranges: 0-1 ft., 0-3 ft., 0-10 ft. or custom ranges Dimensions: height 7.28, width 9.45, depth 4.53 Power supply: 110-120 V AC, power consumption max. 10 W Temperature range: - 5 to + 150 F Accuracy: 0.2 % of adjusted range Materials: Polystyrene (housing and cover) Enclosure: NEMA 4X Input signal: Either from ultrasonic sensor or from hydrostatic level transmitter or other (0)4-20 ma signal. Digital outputs: Terminal 6-17: relay no. 1-4, max. 250 V, max. 4 A resistive / max. 100 W inductive load. Selectable as alarm, counter, flow > 0 or sampler output. Terminal 19-20: Totalizer output (optocoupler), max. 36 V AC/DC, 50 ma, one shot, programmable from 100 ms to 10 s. Analog output: Terminal 21-22: (0)4-20 ma, max. 500 ohm loop resistance, galvanically isolated. Calculation: Standard formulas according to ASTM standards and US Department of the Interior. Optional formula Q = C hx or 10 point level to flow curve linearization. Indication 2 24 character backlit LCD display for reading and calibration. Approvals: UL-cUL listed*, file # 194021 UL 508/c22: 2 No. 142-M1987 Warranty: 1-year limited warranty 4

How the 713 flowmeter works The 713 works by measuring flow in flumes or weirs. The 713 measures the depth of flow in the primary device and calculates the flow rate based on the standard curve for the primary device used. This is typically based on the equation: FLOW Q = level x * constant The exponent ( X ) and constant depends on the type of primary device used. A pre-programmed list of standard weirs and flumes allows easy selection of the equation required for the primary device. Plus custom curves can be configured for non-standard primary devices. The 713 is easily programmed via just 4 function keys: Flow Key, Totalizer Key, Alarm Key and the Sampler Key. The function keys allows access to the various parameters shown below: Flow key: actual flow rate average flow rate - over last hour - today - previous day Totalizer key: total flow - since startup - over last hour - today - previous day - any previous day up to 99 days back Alarm key: displays last 9 alarms with date and time stamp - sensor errors - high and low flow alarms - high and low hourly flows - high and low flow for day - power failure Sampler key: total samples total samples today total samples previous day 5

Flumes For a complete listing of flumes available from MJK, please see data sheet 3.8 Prefabricated Palmer Bowlus and Parshall Flumes. Order numbers, standard Converter Only (consult factory for 10-30 VDC power versions) 209406 713U Converter only. 115 VAC - Use with 75 khz Sensor 200650 or 200651 209410 713U Converter only. 115 VAC - Use with 30 khz Sensor 200570 or 200571 209600 713P Converter Only. 115 VAC - Use with 3400 series hydrostatic level transmitter or Shuttle Level Transmitter Converter with Sensor System Packages 209456 713U Converter. 115 VAC - Includes 75 khz Sensor 200650 with 39 ft. cable. FM Class 1 Div 1 approved 209460 713U Converter. 115 VAC - Includes 30 khz Sensor 200570 with 39 ft. cable 209465 713S Converter. 115 VAC with Shuttle Level Transmitter and 200570 30 khz Ultrasonic Level Sensor with 39 ft. cable 209650 713P Converter. 115 VAC with 3400 level transmitter 209991, 0-1 ft. range, with 39 ft. cable, 1 in MNPT threaded top. 209655 713P Converter. 115 VAC with 3400 level transmitter 209992, 0-3 ft. range, with 39 ft. cable1 in MNPT threaded top. 209660 713P Converter. 115 VAC with 3400 level transmitter 209993, 0-10 ft. range, with 39 ft. cable,1 in MNPT threaded top. Isolators and Zener Barriers (for 3400 series hydrstatic level transmitters - required for Class 1 Div 1 installations) 202993 24VDC powered loop isolator for 3400 series hydrostatic level transmitters 202995 Zener barrier for 3400 series hydrostatic level transmitters Mounting Hardware 200219 Short for use with extension arm 200220 Standard Wall Bracket 200230 Small Flume Bracket for, 22 in. wide 200235 Large Flume Bracket for, 38 in. wide 200205 Universal Bracket holds 200219 or 200220 or 200115 to rail or post 200115 Sun/rain Shield, wall mount 200105 713 Converter Panel Mounting Kit 200020 713 Converter Bezel Frame for panel mounting kit Replacement Sensors 200650 75 khz Sensor with 39 ft. cable. 0-1 or 0-3 ft. range. FM Class 1 Div 1 approved 200651 75 khz Sensor with 150 ft. cable. 0-1 or 0-3 ft. range. FM Class 1 Div 1 approved 200570 30 khz Ultrasonic Level Sensor with 39 ft. cable 200571 30 khz Ultrasonic Level Sensor with 150 ft. cable 209991 3400 hydrostatic level transmitter, 0-1 ft. range, with 39 ft. cable 1 in MNPT threaded top. 209992 3400 hydrostatic level transmitter, 0-3 ft. range, with 39 ft. cable 1 in MNPT threaded top. 209993 3400 hydrostatic level transmitter, 0-10 ft. range, with 39 ft. cable 1 in MNPT threaded top. Custom cable lengths, sensor ranges and solar powered systems are available. Please consult factory. US 3.1 713 Open Channel Flow Converter Datasheet 1202 Distributed by: MJK offices: Denmark www.mjk.dk mjk@mjk.dk +45 45 56 06 56 Norway www.mjk.no mjk@mjk.no +47 69 20 60 70 Sweden www.mjk.se kontoret@mjk.se +46 53 31 77 50 The Netherlands nl.mjk.com mjknl@mjk.com +31 251 672171 Ireland www.mjk.com mke@mjk.com +353 87 953 5625 North America +1 847 482 8655 Australia au.mjk.com mjk@mjk.com +61 3 9755 1529 Singapore www.mjk.sg mjk@mjk.sg