Danfoss PolyPower A/S www.polypower.com
Presentation outline Introduction PolyPower technology and functionality PolyPower applications Project: Under bandage sensor Conclusion May 2012 2
Danfoss PolyPower A/S In 1995 Danfoss President and CEO, Jørgen Mads Clausen had the idea to make a polymer fiber structure that would work like a human muscle 1995 2005, it continued as under the radar projects and skunk work In 2006, a formal project team was established to make proof of concept and secure IPR Danfoss PolyPower A/S was established on July 1st, 2008 with the mandate to commercialize PolyPower DEAP products Danfoss PolyPower A/S is 100% owned by Danfoss A/S 16 employees - R&D, Manufacturing and Sales Within the health care sector we act as a technology provider, working with commercial partners May 2012 3
Presentation outline Introduction PolyPower technology and functionality PolyPower applications Project: Under bandage sensor Conclusion May 2012 4
Unique PolyPower technology A fundamental platform technology targeting applications across industries with unique features: High force density, compact Long strains Direct acting and compliant Unparalleled energy efficiency Very fast acting Proportional Completely silent Light weight May 2012 5
Elongation Basic functionalities Sensors Elastic, capacitive strain sensors Strain capability up to 100% Linear as well as non-planar surfaces Actuators Direct acting capacitive actuators Low power consumption, noiseless and flexible Linear as well as morphing structures Voltage Generators Converts mechanical energy to electrical energy Charging and discharging large variable capacitors Direct acting, potential very high efficiency May 2012 6
Presentation outline Introduction PolyPower technology and functionality PolyPower applications Project: Under bandage sensor Conclusion May 2012 7
Health care applications Artificial Muscles Active Compression Bandage Micro massage patches/bandage Active prosthetics and braces Robotics with gentle touch Silent wearable medicine dosing pumps May 2012 8
Health care applications - Sensors Decubitus monitoring sensor Early warning by monitoring pressure distribution In cooperation with Decutech Aps Breathing monitoring Measurements of movements and/or position Direct measurement on skin Embedded in smart cloth/textiles Rehabilitation training devices Under the bandage pressure sensor May 2012 9
Presentation outline Introduction PolyPower technology and functionality PolyPower applications Project: Under bandage sensor Conclusion May 2012 10
Under bandage sensor - Development process User group study Ideas generation Functional models Group test Prototypes DEAP Value Applications Concepts Requirement Specification Design and build Worn for 2 days Feedback Redesign In progress May 2012 11
User group study User group study Ideas generation Functional models Group test Prototypes Nurses work practice and users life with wounds Existing products and pros/cons of their usage Input of value propositions of PolyPower DEAP film And where user needs could be met with the technology Decided to pursue bandage pressure measurement Note: Active compression bandage possibility May 2012 12
Ideas generation User group study Ideas generation Functional models Group test Prototypes Within scope of bandage pressure measurement Size / proportions Pressure range Usage / fitting /comfort Measurement intervals DEAP configuration Perceived value of the device: Fewer bandage changes Helps ensure correct bandage pressure Avoids high or low pressure spots Shorter healing time On demand or continuous pressure measurements Applied Pressure Inner electrode Compressible foam material Outer electrodes May 2012 13
Functional models User group study Ideas generation Functional models Group test Prototypes Physical concept (mock up) was presented and specification written Production of 5 pieces and 1 instrument setup Electrical connector Textile wiring system for comfort 5 conformable pressure sensing pixels Instrument setup to record data and aid fitting May 2012 14
mmhg Group test User group study Ideas generation Functional models Group test Prototypes User feedback Breathability between sensor and skin Large sensor area Should be less noticeable to wear Connector is uncomfortable Performance Offset in pressure reading at installation Probably caused by non-homogenous compressible material and size of pixels 80 70 60 50 40 30 20 10 0 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 Days May 2012 15
Prototypes User group study Ideas generation Functional models Group test Prototypes 20 prototypes will be produced More comfortable / flexible Smaller connector Thinner Improved accuracy Reduce offset at fitting More pixels Easier to produce Simple design Electrical connection assembly outsourced First step made on dedicated electronics (3 units will be built) Smaller More simple May 2012 16
Presentation outline Introduction PolyPower technology and functionality PolyPower applications Project: Under bandage sensor Conclusion May 2012 17
Konklusion Det har været et spændende og udfordrende projekt Professionelle med vidt forskellig baggrund, erfaringer og kompetencer Bruger dreven innovation konceptet er godt og giver værdifuldt udbytte Projektet afsluttes med et antal færdige prototyper klar til field test Samarbejde med e-stocking projekt på Aarhus universitet Projektet overvejer alternative måder at field teste Vi ønsker at finde en kommerciel partner som kan tage ejerskab for idéen og bringe den til markedet Har du/i andre idéer til anvendelse af teknologien???? May 2012 18