Use and Care Manual. Model CPA12KH AIR CONDITIONER



Similar documents
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

PORTABLE AIR CONDITIONER

Meaco 30L and Meaco 40L dehumidifier instruction manual

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Important Safeguards

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

PORTABLE AIR CONDITIONER (LOCAL)

USER S MANUAL HSC-24A

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

Dehumidifier Users manual. For Models: DH45S DH65S

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

SAFEGUARDING THE ENVIRONMENT

Portable Air Conditioner

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

PORTABLE AIR CONDITIONER

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Climax Air Inc. DC Inverter Portable Air Conditioner Model VS12 12,000 BTU Introducing The World s Most Efficient Portable Air Conditioner

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Get Me Cool Now Portable Air Conditioner User s Manual

Room Air Conditioners

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Instruction manual for Firstline FCS12000CH

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

Taurus Series YORK Window Air Conditioners

FOXAIR 60/50 ALL MODELS

Room Air Conditioners

Split Type Room Air Conditioner. KSWM units

Operating Instructions Air Conditioner

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

REMOTE CONTROL MANUAL

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

INDOOR UNIT/OUTDOOR UNIT

Portable Air Conditioner INSTRUCTION MANUAL

Split Air Conditioner

LG Room Air Conditioner OWNER'S MANUAL

WINDOW ROOM AIR CONDITIONER

Operating Instructions Split System Air Conditioner

2KW CERAMIC HEATER DHCER20. User Manual

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

OPTIONAL SLENDER REMOTE CONTROL

Dehumidifier D 850E. - Instruction manual version 02

LG Multi Type Air Conditioner

Platinum Range PLAC12000HP PORTABLE AIR CONDITIONER WITH HEAT PUMP USER MANUAL HIGH MID COLL HEAT DRY FAN LOW F C TIMER SLEEP SWING

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

PORTABLE AIR CONDITIONER

VACUUM CLEANER INSTRUCTION MANUAL

Installation Instructions and Owner's Manual. Double-Hung Windows Room Air Conditioner. This manual must be left with the owner of the equipment.

SYSTEM Inverter Air Conditioners

DUCT TYPE AIR CONDITIONER

PORTABLE AIR CONDITIONER

DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

GenStore Archive Cabinet

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Multifunction. vax.co.uk Series. What s your Vax model number?

Meaco DD8L desiccant dehumidifier Instruction Manual

PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Ultrasonic support removal tank

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Room Air Conditioners

LG Wireless Remote Controller

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

Hot Water Urns. all models. Helpline. v3.0

DAIKIN ROOM AIR CONDITIONER FT50BSG FT60BSG MODELS. Operation Manual

LG Floor Standing-Type Air Conditioner OWNER'S MANUAL

SWIMMING POOL HEAT PUMP

Central Air Conditioner

OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Cambridge Electric Infared Fireplace User Manual

Air Conditioning System

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

DAIKIN ROOM AIR CONDITIONER FTKD50BSG FTKD60BSG FTKD71BSG MODELS. Operation Manual

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Transcription:

Use and Care Manual Model CPA12KH AIR CONDITIONER

Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage or office. The appliance can be moved from room to room within your home and set-up in just minutes. It is a multi-functional room air exchanging, air-processing appliance, designed to offer you the functions of: Air Conditioning, Dehumidifying, and Independent Fan, and Heating. This manual will provide you with valuable information necessary for the proper care and maintenance for your new appliance. Please take a few moments and read the instructions thoroughly. If properly maintained, your appliance will give you many years of trouble free operation. Electrical Specifications 1.All wiring must comply with local and national electrical codes and be installed by a qualified electrician If you have any questions regarding the following instructions, contact a qualified electrician. 2.Check available power supply and resolve any wiring problems before installation and operation of this unit. 3.For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly grounded, please consult a electrician. Do not use plug adapters or extension cords with this unit use alone if using with extension cord. ( available at most local hardware stores.) 1

Information and advice Safety first!! If the air conditioner is knocked over during use, turn off the unit and unplug from the mains supply immediately. Your air conditioner should be used in such a way that it is protected from moisture e.g. condensation and splashed water. Do not place or store the unit where it can fall or be pulled into water, or any other liquid. Do not operate your air conditioner in a wet room such as a bathroom or laundry room. Do not touch the unit with wet/damp hands or when barefoot. Do not press the buttons on the control panel with anything other than your fingers. Always transport your air conditioner in a vertical position and stand on a stable, level surface during use. Do not allow the unit to sit on top of the mains lead. Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged. Do not wet the housing or control panel. Do not place objects or let any person sit on top of the unit. Do not operate the unit with damaged plug or loose socket point. Always turn the unit off and remove the power plug from the socket when cleaning. Do not cover or obstruct the unit. Never use the mains switch to start and stop the unit.. Always use the switch on the control panel or remote controller. Turn off the unit when not in use. If the unit is not going to be used over a long period of time, disconnect from the mains. Always contact a qualified person to carry out repairs. If the supply cord is damaged it must be repaired by a qualified person. Do not use hazardous chemicals to clean or allow to come into contact with the unit. Do not use the unit in the presence of inflammable substances or vapour such as alcohol, insecticide, petrol etc. Do not allow children to operate the unit unsupervised. Never use the unit without the filter. Do not use the unit for functions other than those described in this instruction manual. Use a minimum of two people to move this unit safely. Do not attempt to remove any part of the casing unless by an authorised technician. Use only the correct power supply AC220V-240V/50Hz. NOTE: Make sure that the back of the unit is at least 50cm or more from a wall. Do not place the unit in front of curtains or drapes incase they fall against the back air intake. 2

Identification of parts Identification of parts 1. Air outlet 2. ON / OFF switch 3.Evaporator air intake 4. Air inlet 3 5.Air outlet hose 4 5 6. Casters 7.Drainage pipe 8. Power supply 6 7 8 3

Operation CONTROL PANEL Mode Control The Mode Control has 4 settings: Cool Dehumidify Fan Heating The settings are adjusted with Mode Control button. A light will indicate which setting is currently being used. Indication symbols on LCD : Cooling mode High fan speed Dehumidify mode Med fan speed Fan only mode Low fan speed Display set temperature Warning light the machine will stop running Display timer setting of auto switch on/off Heating mode Power Control Control Power The power power control control turns turns the the unit unit on on and and off. off. The Warning Light Light Warning Condensed water water may may accumulate accumulate inin the the unit. unit.ifif Condensed the internal internal tank tank becomes becomes full, full,the the Warning Warning signal Light the the unit inwilltheshine LCDand Display will will lightnot upoperate and theuntil unitthe will unitoperate has been not untildrained. the unit has been drained. Fan Speed Speed Control Control Fan The Fan Speed Control has 3 settings: High, The Fan Speed Control has 3 settings: High, Medium, And Low. Medium, and Low. Timer control Auto turn off : With machine in running mode, press timer button for setting timer control. Press " " or " " to select number of hours you would like the unit to run before it automatically shuts off. Auto turn on : With machine in stand by mode, press timer button for setting timer control. Press " " or " " to select number of hours before the until automatically starts running in airconditioning mode. Temperature controls Used for adjusting the thermostat. The default display is room temperature. In cooling mode, when " " or " " button is pressed, the set temperature is displayed and may be adjusted. After 15 seconds the display will revert back to room temperature. Temperature is only adjustable in Cool mode. Note : By pressing both " "/ " " buttons at the same time for more than 3 seconds, the display will toggle between Celsius and Fahrenheit. After switching the air conditioner off, you must wait 3 minutes before switching it back on again. 4 Cooling Mode When cool mode is selected, " " will show in the LCD Display. During the cooling mode the air is cooled and hot air is exhausted to the outside through the exhaust tube. Adjust fan speed and air temperature to suit your desired comfort level. Note : The air exchange hoses must vent outside the room when using cool mode. Dehumidify Mode When Dehumidify mode is selected, " " will show in the LCD Display. Air is dehumidified as it passes through the unit, without being in full cooling mode. If room temperature is 25 degree Fahrenheit, fan speed can be adjusted; otherwise fan speed is fixed to " low ". Note : The warm air exchange hoses must vent inside the room when using Dehumidify Mode, not outside as it does when cooling. If the unit is vented outside some cooling will occur. Fan Mode When Fan mode is selected, " ", " " or " " will be shown in the LCD Display. Air is circulated throughout the room with no cooling. Note: unit does not need to be vented in Fan mode Heating Mode When heating mode is selected," "will show in the LCD Display. Heating is activated only when the ambient temperature is below 27.In this mode, the desired temperature can be set between 16 and 27 Note: When the device is in heating mode, both air hoses must be connected and led outside.

Operation Control Panel Power Key On / Off Mode key : lamp is on when in cooling mode : lamp is on when in dehumidification mode Air Conditioner Remote Control The functions work the same as your air conditioner's touch controls. Batteries : Remove the cover on the back of the remote controller and insert the batteries with the ( + ) and ( - ) poles pointing in the proper direction. ON/OFF Mode : lamp is on when in fan mode Fan Speed Key Heating : Heating mode Fan Speed Up :HIGH :MED :LOW Timer / Temperature Buttons On / Off Timer Key In running mode : Auto switch off In standby mode: Auto switch on Timer Down Used for adjusting the timer and thermostat. The default display is room temperature. When " " or " " button is pressed, the set temperature is displayed and may be adjusted. After 15 seconds the display will revert back to room temperature. CAUTION Use only AAA or IEC R03 1.5V batteries. Remove the batteries if the remote controller is not used for a month or longer. Do not attempt to recharge the supplied batteries All batteries should be replaced at the same time. Do not dispose of the batteries in a fire as they may explode. 5

Installation instructions Installation accessories 1 Description Quantity 1.Air inlet hose...1 / set 2 2.Air outlet hose...1 / set 3.Window exhaust adapter...2 purchase 3 Note: Before moving the product, please ensure all water is removed from the product. (See Maintenance after use on page 9.) IMPORTANT: Do not have any sharp bends or twisting it the umbilical cord. For permanent installation follow instructions. If you are not sure contact a service company. Continuous Drainage (OPTION) METHOD : The umbilical cord can pass through partly open door or window. Fig.1 Caution The location of the indoor unit must have at lease 50cm space at the rear and away from curtains/drapes. 6 Fig.2 If the unit is placed in a location allowing continuous drainage, connect the drainage pipe to the drainage hole (Fig 1/2), and put the other end in a suitable drainage location ie. outside.

Troubleshooting The following cases may not always be a malfunction, please check it before asking for service. Trouble Does not run Analysis If the protector trip or fuse is blown. Please wait for 3 minutes and start again, protector device may be preventing unit to work. If batteries in the remote controller exhausted. If the plug is not properly plugged. Run a short while only If the set temperature is close to room temperature, you can low the set temperature. Air outlet be blocked by obstacle. Take the obstacle away. Run but not cool Do not run and water full indicator lights If the door or window open. If there is other heater appliance work, like heater or lamp, etc... The air filter is dirty, please clean it. Air outlet or intake be blocked. Set temperature is too high. Drain the water into a prepared container by the drainage pipe on the rear panel of the unit. If still doesn't work, please consult a qualified technician. 7

Troubleshooting 1 Appliance maintenance Cut off the power supply Turn off the appliance first before disconnecting from power supply 2 3 4 Wipe with a soft ant dry cloth. Use lukewarm water (below 40 ) to clean the appliance is very dirty. Never use volatile substance such as gasoline or polishing powder to clean the appliance. Never sprinkle water onto the main unit. Dangerous! Electric shock! Air filter maintenance It is necessary to clean the air filter after using it for about 100 hours. Clean it as follows: 1 Stop the appliance and remove the air filter. Stop the appliance first, then pull back the air filter. 2 Clean and reinstall the air filter If the dirt is conspicuous, wash it with a solution of detergent in lukewarm water. After cleaning, dry it in a shaded and cool place, then reinstall it... 3 Clean the air filter every two weeks If the air conditioner operates in an extremely dusty environment. Maintenance after using 1.If the appliance will not be used for a long time, be sure to Pull out the rubber plug of the drain port underside, in order to drain the water. 2.Before storing away run the unit in fan mode only for few hours to dry any moisture on the coils to prevent mould. 3.Stop the appliance and pull out the power supply plug, then take out the batteries of remote controller and keep it well. 4.Clean the air filter and reinstall it. 5.Remove the air hoses and keep them well, and cover the hole tightly. 8

Specifications Figures noted, in the contents are for reference only; variation may result due to application in different countries or regions, and shall be based on the best of practical operation. Description of product Portable Air Conditioner Model CPA12KH Voltage/Frequency AC 220-240V ~ 50Hz Input power(cooling/heating) Operating current(cooling/heating) Capacity(Cooling /Heating) Dehumidifying capacity Coolant 1400 W/1350W 6.4A/6.2A 3.5kW(12000B.T.U./h) / 3.2kW(11000B.T.U./h) 2.0 L/hour R-410A This symbol on the product or the instructions means that your electrical and electronic equipment should be disposed at the end of its life separately from your household waste. There are separate collection systems for recycling in EU. For more information, please contact the local authority or your retailer where you purchased the product. Timer 24 hour Dimensions (W) X(H)X (D) Weight 500 X 900 X 400 mm 38 kg 9

Visit Partmaster.co.uk today for the easiest way to buy electrical spares and accessories. With over 1 million apares and accessories in stock we can deliver direct to your door the very next day. Visit www.partmaster.co.uk or call 0870 6001 338 (UK customers only) Call charged at National Rate.