23/11/2015 TASK 4 REPORT - TECHNICAL ANALYSIS. Use of Task 4 analyses. Introduction and approach - Task 4 objective

Similar documents
Preparatory study on Smart Appliances. Task 1 Scope

Perspectives for ESS in Germany and Europe legal situation and applications StoREgio energy storage system association

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Grid Connected Storage Various Applications Realised with Proven Technologies. Wilhelm van Butselaar Clean Energy Week 2013, Brisbane July 2013

Half the cost Half the carbon

SolarEdge Export Limitation Guide

Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites

Overview - Danfoss Link and living software versions

14. Troubleshooting Guide

sma FlexIble storage system

CUTES Solar Power System

Introduction to the ELSA pilots & use cases

Your own power station: For continuous power

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Self-consumption. that you need to purchase from your power company. Bosch Solar Energy recommends photovoltaic systems with self-consumption.

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

EcoDesign & Labelling Directive (ErP)

Failure code manual. content

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

8 Ways Power Optimizers are Better by Design

REMOTE CONTROL MANUAL

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Totally Integrated Power SIESTORAGE. The modular energy storage system for a reliable power supply.

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Smart buildings in smart grids KNX City. Rafael Marculescu May 2013

Enabling 24/7 Automated Demand Response and the Smart Grid using Dynamic Forward Price Offers

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?

Fronius IG Plus. The next generation grid-connected PV inverter

Wind-Diesel Hybrid System Options for Alaska. Steve Drouilhet National Renewable Energy Laboratory Golden, CO

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

Energy saving tips for home

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

How To Make A Fronius Cl Power Inverter

Appliance Guide. Turn the Page To Turn On Energy Savings

Home Passport Gateway Series Simplify your Life with Smart Solutions

Additional Solar System Information and Resources

Rules of Thumb Energy Efficiency in Buildings

PERFORMANCE OF MPPT CHARGE CONTROLLERS A STATE OF THE ART ANALYSIS

Monitoring solar PV output

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

Water Heating and Heat Recovery 1

Continuous flow direct water heating for potable hot water

The Basics of Solar Power for Producing Electricity An excellent place to start for those just beginning. The basics of solar power: 1000 W/m²

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

M2-ATX. 6-24V Intelligent Automotive ATX Power Supply. Installation Guide Version 1.4 (firmware v1.5, 10/15/2009) P/N M2-ATX-01

Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet'

Storage Battery System Using Lithium ion Batteries

Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia

A SOLAR GUIDE - EVERYTHING YOU NEED TO KNOW

M3-ATX-HV. 6-34V Intelligent ATX Power Supply. Installation Guide Version 1.0c P/N M3-ATX-HV-01

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

Field experience and best practices in managing MW scale Li-ion energy storage systems coupled to large wind and solar plants

NEW. Solar-Log & GE Meter Residential Solar PV Monitoring & Metering Built into a Single Device

SMART GRIDS PLUS INITIATIVE

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

EssPro Energy Storage Grid Substation The power to control energy

HEAVY DUTY STORAGE GAS

Case Study -Sandy Grove Middle School First Net Positive Energy P3 School In North Carolina

HVAC Processes. Lecture 7

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Natural geothermal energy.

GUIDE TO NET ENERGY METERING.

NIPSCO AIR CONDITIONER (AC) CYCLING PROGRAM. Frequently Asked Questions. 1. Can I really make a difference by participating?

SYSTEM MONITORING Locally and remotely

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Commercial Outlook for Solar Power Generation

Riga Smart City Concept. Timurs Safiuļins Riga Energy Agency

ALL STAR ELECTRIC COMPANY 10,000 Trumbull SE, Suite #F Albuquerque, NM (505) voice & fax NM License

SETUP INFO THA-103AC (V1.0R) THA-103AC UPC #

Emerging End Use Technologies

1 Different types of systems Sub-systems Different types of control systems Simple systems analysis... 10

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Dehumidifier D 850E. - Instruction manual version 02

PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

The natural ombination

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

INVERTER SYSTEM PRODUCT BROCHURE

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

Coordinated and Optimized Control of Distributed Generation Integration

ABB central inverters PVS to 1000 kw

Energy Systems Integration

European Distribution System Operators for Smart Grids. Flexibility: The role of DSOs in tomorrow s electricity market

Daikin Altherma. hybrid heat pump. The natural combination

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

SA Power Networks Planning for Solar PV? Customer information guide to network connected solar PV inverter systems

Transcription:

Preparatory study analysing the technical, economic, environmental, market and societal aspects with a view to a broad introduction of smart appliances and developing adequate policy approaches Under multiple framework contract N ENER/C3/2012-418-Lot N 1 TASK 4 REPORT - TECHNICAL ANALYSIS Rainer Stamminger & Jasmin Geppert, University of Bonn Philippe Rivière & Marcel Perret-Gentil, Armines/Mines ParisTech Sven De Breucker/Grietus Mulder, VITO/EnergyVille Jan Viegand, Viegand Maagøe A/S 2 Introduction and approach - Task 4 objective What Technical analysis of products in scope Assessment of technical parameters related to life cycle performance Focus on use phase very little impact on production, distribution and end-of-life phases Products currently on market and in future with potential for DR Which Focus on the selected product group examples products Why Input to next tasks Use of Task 4 analyses Task 4 Technical analyses - Technologies - Energy impact - Product cost Task 5 Base-cases Task 6 Design options Task 7 Scenarios Energy Environment Economy Employment 3 4 1

Limitations and how to overcome them Technologies Only few smart appliances on market Limited data received on current products Analyses based on estimations and data available Can improve report with more precise and updated data Request data from industry Traditional appliances modified for DR e.g.:» Other control systems to process and react on the DR response signals» Other components for DR e.g. energy storage, safety circuits, measurement circuits, sensors etc.» Modifications in existing control system programming» Additional power supply to electronics 5 6 Use phase Energy consumption impacts Use phase Energy regulation Additional electronics Longer on-time for the electronics Consumption home energy manager Network standby horizontal requirement:» From 1 January 2015: 6.00 W» From 1 January 2017: 3.00 W» From 1 January 2019: 2.00 W (subject to review) 1275/2008 Increased losses in energy storage systems (batteries, water tanks, building components for storing heat etc.) Consumption smart meter Vertical requirements such as lamp control gear: 1 W (0.5 W Sept. 2016) 7 8 2

Use phase Network connections Network type Power consumption, Watt Min Max Average Bluetooth Classic 1 Bluetooth 4.0 0.000147 0.5 0.250074 Wi-Fi 0.51 1.9 1.205 ZigBee 0.068 0.589 0.3285 Z-Wave 0.07 Ethernet, active link, 1000 Mbps 0.425 1.64 1.0325 Ethernet, active link, 100 Mbps 0.22 0.65 0.435 Ethernet, active link, 10 Mbps 0.22 0.69 0.455 APPLIANCE EXAMPLES Appliances:» Dishwashers, washing machines, tumble dryers, washer-dryers» Radiators and built-in inertia radiators» Boilers» Heat pumps» Circulators» Residential air conditioners» Ventilation» Residential energy storage system» Lighting Assessments: (product price = manufacturer cost + mark-up) (cost, environment) 9 10 Periodical appliances (dishwashers, washing machines, tumble dryers, washer-dryers) Periodical appliances (dishwashers, washing machines, tumble dryers, washer-dryers) possibilities comprise:» Wi-Fi connection» Connection via Gateway» Frequency sensing Some models are already available from a few manufactures in the European market needed:» Respective network connection device» Switch to activate / deactivate smart operation : Enabling periodical appliances for DR-functions requires new control software (dependent on level of smartness anticipated) and an extension of memory capacities.» Signal activation: software to recognize signals from the grid and to activate device before a predefined deadline is reached.» Remote activation: software allowing bidirectional communication and activating the machine in response to the remote signal.» Altered electricity consumption pattern: signal recognition software and an energy management software to find the most suitable reaction in response to signal and transform it into action. 11 12 3

Periodical appliances (dishwashers, washing machines, tumble dryers, washer-dryers) s:» Remote or signal activation: the user selected programme is remotely activated or activated by a signal coming from the grid before the user deadline is reached.» Altered electricity consumption pattern: while the appliance is activated, the consumption patterns changed through pausing the operation, changing the temperatures, changing heating power, changing spinning speed (in the case of washing machines and washer dryers) etc. Periodical appliances (dishwashers, washing machines, tumble dryers, washer-dryers) : dependent on the level of smartness anticipated:» Signal activation: a signal recognition unit as well as a start-time delay function/ time function are needed (assumed additional costs 10-50 )» Remote activation: a switch is needed to signal activation and a communication module is required enabling bidirectional communication (assumed additional costs 30-130 )» Altered electricity consumption pattern: a signal recognition unit and an energy management software are necessary (assumed additional costs 10-100 ) 13 14 Periodical appliances (dishwashers, washing machines, tumble dryers, washer-dryers) : : maximum energy values stipulated in the amended standby regulation (COMMISSION REGULATION (EU) No 1275/2008) are assumed» Standby energy consumption (signal or remote activation): while waiting for start of machine or at the end of a cycle (standby power max. 0.5 W, 1 W in case of informative displays)» Short-term interruptions: may increase energy consumption due to the need to recover heat losses» Lowering process temperature: may reduce energy consumption» Pausing of operation: may require energy consuming measures to maintain performance of the process (e.g. drum rotation etc.) Radiators and built-in inertia radiators» Pilot wire to smart meter, wireless networks» Electronic thermostat capable of sending/receiving external signals (i.e. from the grid, the user)» Adaptability between the electronic thermostat and the radiator (Nest Heat Link i.e.) 15 16 4

Radiators and built-in inertia radiators Electric Boilers» Radiators work on/off. Modulating programs (Comfort, Eco, Cold) by varying indoor temperature set point i.e.» Due to energy consumption: (4.5W/1000*8760h*0.20 /kwh=8 ).» Installation of demand response: electronic thermostat (Wi-Fi enabled =~ 200, Honeywell, Nest )» RTE approximation (receiving only) 35/85» If wireless enabled, estimation of 6W (3W by 2019, EU regulations). Manufacturers estimate nowadays an average consumption of 4,5W for a communicating device» Wireless technologies via electronic thermostat» Electronic thermostat that controls the water drained from the boiler to the radiators.» Adaptability between the thermostat and the boiler (i.e. Nest Heat Link) 17 18 Electric Boilers» On/off. Possibility to store energy in a tank and use it afterwards» Due to energy consumption: (4.5W/1000*8760h*0.20 /kwh=8 ).» Installation of demand response: electronic thermostat (Wi-Fi enabled =~ 200, Honeywell, Nest )» RTE approximation (signal receiving only) 35/85» If wireless enabled, estimation of 6W (3W by 2019, EU regulations). Manufacturers estimate nowadays an average consumption of 4,5W for a communicating device Heat pumps» Wireless technologies via electronic thermostat» Electronic thermostat, capable of modulating the charge?» Adaptability between the thermostat and the heat pump (intermediate device between the thermostat and the heat pump, software). If the heat pump is used for hot water supply, a storage tank could be used to gain more shifting potential» On/off, modulating the charge of the compressor, signals to storing water in a storage tank. According to (Delta Study), must manufacturers agree that variable tariffs is the way to optimize profits from a DR program 19 20 5

Heat pumps Boiler Circulators» Due to energy consumption: (4.5W/1000*8760h*0.20 /kwh=8 ).» Installation of demand response: electronic thermostat (Wi-Fi enabled =~ 200, Honeywell, Nest )» RTE approximation (receiving only) 35/85» Manufacturer information: 100 /200 to enable DR (software adaptability, intervention)» If wireless enabled, estimation of 6W (3W by 2019, EU regulations). Manufacturers estimate nowadays an average consumption of 4,5W for a communicating device» The pumps are integrated to the boiler s control system, and will operate when the boiler according to the demand» Control interface capable of sending a signal from the boiler to the pumps according to the demand requested.» Communication between the pump and the boiler, variable speed drives pumps to enable part load regimes» On/off, part load regime : Communication between the circulators and the boiler 0 : 0 21 22 Air conditioners Air conditioners» Electronic thermostat (via wireless technologies)» Electronic thermostat (capable of receiving external signals), software adaptability» Adaptability between the thermostat and the air conditioner (intermediate device between the thermostat and the A/C).» On/off, part load regime via inverter A/C» Due to energy consumption: (4.5W/1000*8760h*0.20 /kwh=8 ).» Installation of demand response: electronic thermostat (Wi-Fi enabled =~ 200, Honeywell, Nest )» RTE approximation (receiving only) 35/85» Manufacturer information: 100 /200 to enable DR (software adaptability, intervention)» If wireless enabled, estimation of 6W (3W by 2019, EU regulations). Manufacturers estimate nowadays an average consumption of 4,5W for a communicating device 23 24 6

Ventilation Ventilation» Ventilation potential in the residential sector is negligible (very low energy consumption from the extractor fans in kitchen and bathrooms). In addition, most of the time there s no control from the users.» Mechanical ventilation units do only have an on/off switch, the connectivity to the network must be done via a hardware installation (wire between the electric meter to the ventilation unit)» New circuits that can receive signal from the aggregator/utility and can turn on/off the ventilation, must be installed.» On/off, part load regime via variable speed drive» Appliance modification: variable speed drive, on/off circuit» No available information» No available information 25 26 System characteristics» Current markets in Europe: Germany, Austria, Switzerland» +40 suppliers, +200 systems» 25,000 systems installed in GE: 13 ct/kwh feed-in, 30 ct/kwh electricity price => 17 ct/kwh self-consumption incentive» Increase self-consumption from 20-40 % to 60-70 %» Grid connection: 1ph or 3ph» E: 2-10 kwh residential 100 kwh SME» P: 1,5-10 kw Network connection: Integrated system Input = PV array / Output = Grid connection Extensive power electronics: Dc-dc converters for PV Dc-dc converter for battery Grid-inverter Increased efficiency, but SPOF Network connection: Separate AC First system: Battery & dc-dc converter & grid-inverter Second system: PV-string (& dc-dc converter) & grid-inverter Requires PV measurement comm to battery system More conversion losses 27 28 7

Inherent grid services: ~ Peak shaving» Store PV peak, supply demand peak => voltage support» Overvoltage: PV peak» Undervoltage: demand peak => Q support» Voltage support by Q injection (grid losses) Grid frequency services:» Primary frequency reserve: Emphasis on power, discharging and charging of battery BUT limited energy exchange» secondary frequency reserve (down-regulation): battery charged with e.g. excess wind energy if frequency too high Current capabilities Drastically increase self consumption Local weather forecasting Home energy management ~ local demand response: Remote control of HH appliances: start washing machine at PV peak Remote control of heat pump or airco EEbus protocol, OpenHab Protocol Ready for VPP and dynamic pricing Internet connection for aggregator communication 29 30 Current concerns» All systems capable of grid energy storage, sometimes forbidden by legislation» System efficiency:» 98 % grid-inverter, 97 % dc-dc converter [+ 0,1-0,4, ++ 0,4-1 P nom]» 90 % battery» Integrated system storing PV: 15% loss [0,97*0,9*0,97] PV» Grid storage: ~20% loss [0,98*0,97*0,9*0,97*0,98]» Standy losses: up to 5-80 W, 30 W ave => 263 kwh per year GRID AC- DC CTRL DC-link DC- DC DC- DC BAT Hardware: none Bidirectional currents possible for integrated and separate systems Software: from basic to advanced Basic: I to grid, V/f off-grid, f support > 50,2 Hz, PV peak shaving Energy mgmt: power settings PV, battery, heat pumps, EV, white goods & advanced weather forecasting Integral part of residential storage or separate system Internal SP or external SP aggregator 31 32 8

Software: from basic to advanced Self-learning algorithms: distributed measurement, flexibility, nearterm power requirements Grid interaction software: Advanced frequency support: primary [49,8-50,2 Hz] From aggregator: Secondary down-regulation Voltage droop: active power curtailment Reactive power support Current redistribution between phases : Not predictable, ~ complexity, ~ extensiveness Energy impact» Increase in self consumption: 5,4 TWh 15 % lost in conversion losses: 0,8 TWh gone» Available flexibility: 1,1 TWh 20 % losses in grid E-storage: 0,2 TWh gone» 6,5 TWh energy shifted, 1 TWh conversion losses» 5 W standby loss: 0,2 TWh 1,2 TWh» 80 W standby loss: 3 TWh 7,2 TWh GRID 5,4 TWh 5,4 TWh 1,1 TWh PV 18 TWh 33 0,2 TWh 0,8 TWh 34 Lighting» Wired (mainly Ethernet)» Wireless connections (Wi-FI, Bluetooth, Zigbee etc.)» Electronics for communicating with central energy manager (CEM)» Some systems include control box for LED bulbs» None or few (assuming communication with CEM)» Reduce light intensity or switch off» Substantial costs today on remote managed systems» Energy for electronics» Products within 1194/2012: Lamp control: < 1 W Commercial refrigeration? 35 36 9

Discussion» Can we get closer to real life data incl. for commercial refrigeration?» Will costs of DR enabling of appliances be reduced over time with more integrated solutions?» Will we see a DR System on Chip with reduction of price and consumption? 37 10