Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - Sweden



Similar documents
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - Sweden

Safety Data Sheet SOMAmer Reagent

SAFETY DATA SHEET SureSeq Solid Tumour Panel

OneSeq Human Reference DNA, Male, Part Number OneSeq Human Reference DNA, Male, Part Number

SAFETY DATA SHEET WINTERHALTER A81 BLUE ENZYME DRAIN CLEANER

SureFISH Probes - Green, Part Numbers G100000G through G100199G CHEMTREC :

PATHWAYS DRAIN TREATMENT. Use only for the purpose on the product label.

SAFETY DATA SHEET. Sika 1+

SAFETY DATA SHEET PRIVATE LABEL SULPHURIC ACID DRAIN CLEANER SPD1047/SPD1046

SAFETY DATA SHEET. Section 1: Identification of the substance/mixture and of the company/undertaking. KaVo Everest ZS-Blanks und Ronden

Material Safety Data Sheet JM Roofing System Urethane Adhesive, Part 2.

Material Safety Data Sheet

SAFETY DATA SHEET BOSTIK AQUAGRIP 536

Material Safety Data Sheet

Ponasterone A, Part Number SECTION 1: Identification of the substance/mixture and of the company/ undertaking.

SAFETY DATA SHEET EVO-STIK PLUMBERS MAIT

SECTION 1: Identification of the substance/mixture and of the company/undertaking

SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING. Enzymatic Drain Cleaner and Maintainer

Safety Data Sheet. (REACH Regulation (EC) No. 1907/2006 No. 453/2010)

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Not applicable 3.2. Mixture

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830 - United Kingdom (UK)

Safety data sheet. May cause slight irritation to the skin and eyes.

: MR MUSCLE Window & Glass Cleaner

SECTION 1 Identification of the substance/mixture and of the company

SAFETY DATA SHEET ELEGANCE R.T.U.

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II and Regulation (EC) No. 1272/2008 (CLP) - Europe. Bona Wood Floor Cleaner

SAFETY DATA SHEET CLEENOL LIFT WINDOW & MIRROR CLEANER

1. Identification of the substance/preparation and the company/undertaking

Current version : 2.0.1, issued: Replaced version: 2.0.0, issued: Region: GB

: Water and Glycol Leak Detection Solution

Material Safety Data Sheet

SAFETY DATA SHEET CLEENOL LIFT SPRAY CLEANER WITH BACTERICIDE

ENZYMATIC DRAIN CLEANER AND

SAFETY DATA SHEET CLEENOL LIFT ORIGINAL MULTIPURPOSE CLEANER

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING SULPHURIC ACID DRAIN CLEANER

MATERIAL SAFETY DATA SHEET according to the (US) Hazard Communication Standard (29 CFR )

Safety data sheet. Revision: Replaces: Version: 02.00/GBR

1-Bromo-2,5-dimethoxybenzene

Main Drain Opener Safety Data Sheet

advice (show the label where possible).

1. IDENTIFICATION. US IVD HCCA, portioned BD Bruker US IVD HCCA, Portioned

SAFETY DATA SHEET CLEENOL LIFT SPRAY CLEANER WITH BACTERICIDE

SAFETY DATA SHEET CLEENOL LIFT WAX FREE POLISH

Sikafloor 20/21/29/31 Purcem Part A. Sika Australia Pty. Ltd. 55 Elizabeth Street (Locked Bag 482 BDC) Wetherill Park, NSW 2164 Australia

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Regulation (EU) No. 2015/830 - United Kingdom (UK)

SAFETY DATA SHEET CLEENOL LIFT PEACH ORCHARD AIR FRESHENER

SAFETY DATA SHEET. 1 Identification of the substance/mixture and of the company/undertaking. 2 Hazards identification

SAFETY DATA SHEET Revised edition no : 1 SDS/MSDS Date : 26 / 11 / 2012

SAFETY DATA SHEET. HEAT SINK COMPOUND Tube

Calendula Extract Safety Data Sheet

: GLADE Aerosol - Lavender

SAFETY DATA SHEET EVO-STIK GRIPFILL SOLVENT FREE (Irl)

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006 Doc. N C rev.0 Date of issue: 23/03/2015

: Fairy Professional Original Washing Up Liquid 5L

: WOLF RADIATOR SEALER & CONDITIONER

: Mystic Home Pest Control

SAFETY DATA SHEET CLEENOL LIFT SPRAY CLEANER WITH BACTERICIDE

MATERIAL SAFETY DATA SHEET DakotaSyn Full Synthetic 75W-90; 0005 MSDS PREPARATION DATE: 1/6/14

SAFETY DATA SHEET CLEENOL LIFT GRAFFITI REMOVER

SAFETY DATA SHEET ACCORDING TO EC-REGULATIONS 1907/2006 (REACH), 1272/2008 (CLP) & 453/2010

SAFETY DATA SHEET. Synonyms Part Numbers: 25605, 25615, 25631, 25636, 25641, 25641R, 35646

Epinephrine (cas ) MSDS

SAFETY DATA SHEET. Order T: Moulton Street Cambridge, MA 02138, USA

Material Safety Data Sheet

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 13 / 7 / 2012

: Henko all weather comp B

Safety Data Sheet. Substance. Revision 1.01 modified: 15/03/2011 SECTION 1: Identification of the substance/mixture and of the company

Safety data sheet according to 1907/2006/EC, Article 31

SAFETY DATA SHEET TIDYFOAM E2 HAND CLEANER SANITIZER

SAFETY DATA SHEET TRI-STAR SO FRESH

Safety Data Sheet UNICO 3

Material Safety Data Sheet

SAFETY DATA SHEET Confirms to OSHA Hazard Communication Standard (CFR ) HazCom 2012

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 10 / 7 / 2012

SAFETY DATA SHEET RINSE AID

Issue Date: 04-Oct-2013 Revision Date: 19-Nov-2014 Version Number: Identification. 2. Hazards Identification

92699, 92708, 92732, 53825, 53810, : D-55Y Yellow UV Leak Detection Dye Concentrate

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 18 / 7 / 2012

Material Safety Data Sheet

SAFETY DATA SHEET. Everbuild Multipurpose Linseed Oil Putty - Natural. Everbuild Multipurpose Linseed Oil Putty - Natural

Material Safety Data Sheet

Replaces Version: - / CH. 1. Identification of the substance/mixture and of the company/undertaking. Relaroom extract

Safety Data Sheet acc. to OSHA HCS

PRODUCT SAFETY DATA SHEET Product name: SOFT LEAD PRODUCTS

Magnesium Carbonate, Lite, Powder USP

Engine and Transmission Flush

SECTION 2: HAZARDS IDENTIFICATION OSHA/HCS Status: This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR ).

SECTION 1: Identification of the substance/mixture and of the company/undertaking

3M Flip-Top Dilution Bottle - Peptone Water (formerly Biotrace Flip Top Dilution Bottles, 99ml Peptone Water) 07/31/15

Issuing Date: 27-Feb-2015 Revision Date: 27-Feb-2015 Version 1 1. IDENTIFICATION. Finished Product - Consumer (Retail) Use Only

Transcription:

SikaFiresil N Product name SAFETY DATA SHEET Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II Sweden SECTION 1 Identification of the substance/mixture and of the company/ undertaking 1.1 Product identifier SikaFiresil N 1.2 Relevant identified uses of the substance or mixture and uses advised against At present there is no complete information available on identified uses. When the data becomes available, it will be integrated into the safety data sheet. Product use Sealant/adhesive. 1.3 Details of the supplier of the safety data sheet Manufacturer/Distributor Telephone no. Emergency telephone number Sika Sverige AB Box 8061 163 08 Spånga Sverige 086218900 Fax no. 086218989 email address of person responsible for this SDS EHS@se.sika.com 112 Begär Giftinformation 1.4 Emergency telephone number Supplier Telephone number 112 Begär Giftinformation SECTION 2 Hazards identification 2.1 Classification of the substance or mixture Product definition Mixture Classification according to Regulation (EC) No. 1272/2008 [CLP/GHS] Not classified. The product is not classified as hazardous according to Regulation (EC) 1272/2008 as amended. Classification according to Directive 1999/45/EC [DPD] The product is not classified as dangerous according to Directive 1999/45/EC and its amendments. Classification Not classified. See Section 16 for the full text of the R phrases or H statements declared above. See Section 11 for more detailed information on health effects and symptoms. 2.2 Label elements Hazard pictograms Signal word Hazard statements Precautionary statements Hazardous ingredients Supplemental label elements No signal word. No known significant effects or critical hazards. Safety data sheet available on request. Date of issue 05.06.2015. MSDS no. 1114871 1/10

SikaFiresil N 05.06.2015 2/10 SECTION 2 Hazards identification Annex XVII Restrictions on the manufacture, placing on the market and use of certain dangerous substances, mixtures and articles 2.3 Other hazards Other hazards which do not result in classification None known. SECTION 3 Composition/information on ingredients Substance/mixture Chemical family/ Characteristics Mixture Polysiloxane Product/ingredient name Identifiers bis(ethyl acetoacetatoo1',o3)bis (2methylpropan1olato)titanium EC 2811616 CAS 83877912 % >=1 <5 R10 Xi; R36 67/548/EEC See Section 16 for the full text of the Rphrases declared above. Classification Regulation (EC) No. 1272/2008 [CLP] Flam. Liq. 3, H226 Eye Irrit. 2, H319 See Section 16 for the full text of the H statements declared above. Type [1] There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs or vpvbs or have been assigned a workplace exposure limit and hence require reporting in this section. Type [1] Substance classified with a health or environmental hazard [2] Substance with a workplace exposure limit [3] Substance meets the criteria for PBT according to Regulation (EC) No. 1907/2006, Annex XIII [4] Substance meets the criteria for vpvb according to Regulation (EC) No. 1907/2006, Annex XIII [5] Substance of equivalent concern Occupational exposure limits, if available, are listed in Section 8. SECTION 4 First aid measures 4.1 Description of first aid measures Eye contact Inhalation Skin contact Ingestion Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs. Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur. Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur. Date of issue 05.06.2015. MSDS no. 1114871 2/10

SikaFiresil N 05.06.2015 3/10 SECTION 4 First aid measures 4.2 Most important symptoms and effects, both acute and delayed Potential acute health effects Eye contact No known significant effects or critical hazards. Inhalation No known significant effects or critical hazards. Skin contact No known significant effects or critical hazards. Ingestion No known significant effects or critical hazards. Overexposure signs/symptoms Eye contact No specific data. Inhalation No specific data. Skin contact No specific data. Ingestion No specific data. 4.3 Indication of any immediate medical attention and special treatment needed Notes to physician Specific treatments Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled. No specific treatment. SECTION 5 Firefighting measures 5.1 Extinguishing media Suitable extinguishing media Unsuitable extinguishing media Use an extinguishing agent suitable for the surrounding fire. None known. 5.2 Special hazards arising from the substance or mixture Hazards from the substance or mixture Hazardous thermal decomposition products In a fire or if heated, a pressure increase will occur and the container may burst. Decomposition products may include the following materials carbon dioxide carbon monoxide metal oxide/oxides 5.3 Advice for firefighters Special protective actions for firefighters Special protective equipment for firefighters Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Firefighters should wear appropriate protective equipment and selfcontained breathing apparatus (SCBA) with a full facepiece operated in positive pressure mode. Clothing for firefighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents. Date of issue 05.06.2015. MSDS no. 1114871 3/10

SikaFiresil N 05.06.2015 4/10 SECTION 6 Accidental release measures 6.1 Personal precautions, protective equipment and emergency procedures For nonemergency personnel For emergency responders No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment. If specialised clothing is required to deal with the spillage, take note of any information in Section 8 on suitable and unsuitable materials. See also the information in "For nonemergency personnel". 6.2 Environmental precautions Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air). 6.3 Methods and materials for containment and cleaning up Small spill Large spill Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if watersoluble. Alternatively, or if waterinsoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor. Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with noncombustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. 6.4 Reference to other sections See Section 1 for emergency contact information. See Section 8 for information on appropriate personal protective equipment. See Section 13 for additional waste treatment information. SECTION 7 Handling and storage 7.1 Precautions for safe handling Protective measures Advice on general occupational hygiene Put on appropriate personal protective equipment (see Section 8). Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures. 7.2 Conditions for safe storage, including any incompatibilities Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and wellventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination. 7.3 Specific end use(s) Recommendations Industrial sector specific solutions Date of issue 05.06.2015. MSDS no. 1114871 4/10

SikaFiresil N 05.06.2015 5/10 SECTION 8 Exposure controls/personal protection The information in this section contains generic advice and guidance. Information is provided based on typical anticipated uses of the product. Additional measures might be required for bulk handling or other uses that could significantly increase worker or exposure or environmental releases. 8.1 Control parameters Occupational exposure limits No exposure limit value known. Recommended monitoring procedures DNELs/DMELs No DELs available. PNECs No PECs available. If this product contains ingredients with exposure limits, personal, workplace atmosphere or biological monitoring may be required to determine the effectiveness of the ventilation or other control measures and/or the necessity to use respiratory protective equipment. Reference should be made to monitoring standards, such as the following European Standard EN 689 (Workplace atmospheres Guidance for the assessment of exposure by inhalation to chemical agents for comparison with limit values and measurement strategy) European Standard EN 14042 (Workplace atmospheres Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents) European Standard EN 482 (Workplace atmospheres General requirements for the performance of procedures for the measurement of chemical agents) Reference to national guidance documents for methods for the determination of hazardous substances will also be required. 8.2 Exposure controls Appropriate engineering controls Individual protection measures Hygiene measures Eye/face protection Skin protection Hand protection Body protection Other skin protection Respiratory protection Environmental exposure controls Good general ventilation should be sufficient to control worker exposure to airborne contaminants. Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period. Appropriate techniques should be used to remove potentially contaminated clothing. Wash contaminated clothing before reusing. Ensure that eyewash stations and safety showers are close to the workstation location. Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection safety glasses with sideshields. Chemicalresistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Reference number EN 374. Recommended Butyl rubber/nitrile rubber gloves. Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. No special measures required. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels. Date of issue 05.06.2015. MSDS no. 1114871 5/10

SikaFiresil N 05.06.2015 6/10 SECTION 8 Exposure controls/personal protection SECTION 9 Physical and chemical properties 9.1 Information on basic physical and chemical properties Appearance Physical state Color Odor Odor threshold ph Melting point/freezing point Initial boiling point and boiling range Flash point Evaporation rate Flammability (solid, gas) Burning time Burning rate Upper/lower flammability or explosive limits Vapor pressure Vapor density Density Relative density Solubility(ies) Partition coefficient noctanol/ water Autoignition temperature Decomposition temperature Viscosity Explosive properties Oxidizing properties Paste. Various Fruity. Closed cup ~1.5 g/cm³ [20 C (68 F)] Dynamic (room temperature) 500000 mpa s Kinematic (40 C) >0.205 cm 2 /s 9.2 Other information No additional information. SECTION 10 Stability and reactivity 10.1 Reactivity No specific test data related to reactivity available for this product or its ingredients. 10.2 Chemical stability The product is stable. 10.3 Possibility of hazardous reactions Under normal conditions of storage and use, hazardous reactions will not occur. 10.4 Conditions to avoid No specific data. 10.5 Incompatible materials No specific data. Date of issue 05.06.2015. MSDS no. 1114871 6/10

SikaFiresil N 05.06.2015 7/10 SECTION 10 Stability and reactivity 10.6 Hazardous decomposition products Under normal conditions of storage and use, hazardous decomposition products should not be produced. SECTION 11 Toxicological information 11.1 Information on toxicological effects Acute toxicity Conclusion/Summary Irritation/Corrosion Conclusion/Summary Sensitization Conclusion/Summary Mutagenicity Conclusion/Summary Carcinogenicity Conclusion/Summary Reproductive toxicity Conclusion/Summary Teratogenicity Conclusion/Summary Specific target organ toxicity (single exposure) Specific target organ toxicity (repeated exposure) Aspiration hazard Information on the likely routes of exposure Potential acute health effects Eye contact Inhalation Skin contact Ingestion No known significant effects or critical hazards. No known significant effects or critical hazards. No known significant effects or critical hazards. No known significant effects or critical hazards. Delayed and immediate effects and also chronic effects from short and long term exposure Short term exposure Potential immediate effects Potential delayed effects Long term exposure Potential immediate effects Potential delayed effects Potential chronic health effects Conclusion/Summary General No known significant effects or critical hazards. Date of issue 05.06.2015. MSDS no. 1114871 7/10

SikaFiresil N 05.06.2015 8/10 SECTION 11 Toxicological information Carcinogenicity No known significant effects or critical hazards. Mutagenicity No known significant effects or critical hazards. Teratogenicity No known significant effects or critical hazards. Developmental effects No known significant effects or critical hazards. Fertility effects No known significant effects or critical hazards. Other information SECTION 12 Ecological information 12.1 Toxicity Conclusion/Summary 12.2 Persistence and degradability Conclusion/Summary 12.3 Bioaccumulative potential 12.4 Mobility in soil Soil/water partition coefficient (KOC) Mobility 12.5 Results of PBT and vpvb assessment PBT vpvb 12.6 Other adverse effects No known significant effects or critical hazards. SECTION 13 Disposal considerations 13.1 Waste treatment methods Product Methods of disposal European waste catalogue (EWC) Waste code The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any byproducts should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and nonrecyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction. Waste designation 08 04 10 waste adhesives and sealants other than those mentioned in 08 04 09 Packaging Completely emptied packagings may be given for recycling. Empty packaging may still contain hazardous residues. Empty packaging should be removed by a licensed waste contractor. Date of issue 05.06.2015. MSDS no. 1114871 8/10

SikaFiresil N 05.06.2015 9/10 SECTION 14 Transport information ADR/RID ADN IMDG IATA 14.1 UN number Not regulated. Not regulated. Not regulated. 14.2 UN proper shipping name 14.3 Transport hazard class(es) 14.4 Packing group 14.5 Environmental hazards Additional information No No No 14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code SECTION 15 Regulatory information 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture EU Regulation (EC) No. 1907/2006 (REACH) Annex XIV List of substances subject to authorization Annex XIV None of the components are listed. Substances of very high concern None of the components are listed. Annex XVII Restrictions on the manufacture, placing on the market and use of certain dangerous substances, mixtures and articles Other EU regulations VOC content (EU) VOC (w/w) 0% REACH Information All substances contained in our Products are preregistered or registered by our upstream suppliers, and/or preregistered or registered by us, and/or excluded from the regulation, and/or exempted from the registration. Europe inventory All components are listed or exempted. 15.2 Chemical Safety Assessment This product contains substances for which Chemical Safety Assessments are still required. Date of issue 05.06.2015. MSDS no. 1114871 9/10

SikaFiresil N 05.06.2015 10/10 SECTION 16 Other information Indicates information that has changed from previously issued version. Abbreviations and acronyms Full text of abbreviated H statements Full text of classifications [CLP/GHS] Full text of abbreviated R phrases Full text of classifications [DSD/DPD] ATE = Acute Toxicity Estimate CLP = Classification, Labelling and Packaging Regulation [Regulation (EC) No. 1272/2008] DNEL = Derived No Effect Level EUH statement = CLPspecific Hazard statement PNEC = Predicted No Effect Concentration RRN = REACH Registration Number H226 H319 R10 Flammable. R36 Irritating to eyes. Xi Irritant Flammable liquid and vapor. Causes serious eye irritation. Eye Irrit. 2, H319 SERIOUS EYE DAMAGE/ EYE IRRITATION Category 2 Flam. Liq. 3, H226 FLAMMABLE LIQUIDS Category 3 History Date of printing 05.06.2015. Date of issue 05.06.2015. Date of previous issue 08.09.2014. Notice to reader The information contained in this Safety Data Sheet corresponds to our level of knowledge at the time of publication. All warranties are excluded. Our most current General Sales Conditions shall apply. Please consult the product data sheet prior to any use and processing. Date of issue 05.06.2015. MSDS no. 1114871 10/10