DNA Analyst Training Laboratory Training Manual Protocol 2.02 Clean Technique



Similar documents
Archived. Gloves should be changed frequently during the analysis.

Appendix J IBC Biohazard Spill Management Plan

Biosafety Spill Response Guide

Scott & White Institutional Biosafety Committee Compliance Program Biohazardous Material Spill Clean-Up Procedure Policy #IBC.002

Blood Collection and Processing SOP

FAD-DNA-SOP-TOC.1 Page 1 of 2 Issued by Technical Leader

Carnegie Mellon University s Policy and Procedures for Recombinant and Synthetic Nucleic Acid Materials Spills

Protocol for Disinfection of Cell Culture and Tissue Culture in Media:

STANDARD OPERATING PROCEDURES SPILL RESPONSE AND CLEAN-UP OUTSIDE BIOSAFETY CABINET

Standard Operating Procedure for Dacarbazine in Animals

BSL 1 Laboratory Biosafety Manual

Guidelines for Ethidium Bromide Waste Management & Disposal. University of Tennessee-Knoxville

Biosafety Level 2 Criteria

Biological Safety Program

OESO Ergonomics Division ERGO(3746) Duke Police Corporate Risk Management

THE UNIVERSITY OF NEWCASTLE- SCHOOL of BIOMEDICAL SCIENCES

The following standard practices, safety equipment, and facility requirements apply to BSL-1:

Laboratory Biosafety Plan Template. For Biosafety Level 1 and 2

Biosafety Guidelines. 5. Pipetting Mechanical pipetting devices must be available and used. Mouth pipetting is prohibited.

Risk Assessment: Biosafety Cabinet

Safe Operating Procedure

BOSTON COLLEGE ENVIRONMENTAL HEALTH AND SAFETY LABORATORY GUIDE FOR RENOVATIONS, REMODELS, MOVES AND TERMINATIONS

Lab Safety and Standard Operating Procedures. Faculty of Dentistry And School of Biomedical Engineering

Procedures for the Effective Use of Biological Safety Cabinets

Laboratory Biosafty In Molecular Biology and its levels

Lab Biosafety Level 3 Checklist (dates: April 16, 1998)

Particularly Hazardous Substances (PHS) Standard Operating Procedure (SOP)

Laboratory Biosafety Level 3 Criteria

Response to Biological Spills in the Laboratory (Intentional or Accidental)

The Arkansas State Crime Laboratory. Forensic DNA Section. Quality Assurance Manual

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Beware that ordinary prescription glasses do not provide adequate protection. This is also true with poorly fitting safety glasses.

Biosafety Level 2 (BSL-2) Safety Guidelines

PI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3)

Training on Standard Operating Procedures for Health Care Waste Management Swaziland 12 May, 2011

UltraClean PCR Clean-Up Kit

HBV Quantitative Real Time PCR Kit

Laboratory Safety Inspection Checklist (Biology and Biochemistry)

Blood Borne Pathogen Exposure Control Plan Checklist

UNIVERSITY OF NEVADA LAS VEGAS BSL-3 LABORATORY STANDARD OPERATING PROCEDURES (SOPS)

CITY OF CHESTERFIELD POLICE DEPARTMENT GENERAL ORDER EFFECTIVE: MAY 5, 2011 CANCELS: GENERAL ORDER

Coating and Extraction of Honeycomb Denuders

UNH SAFETY AUDIT Office of Environmental Health and Safety

Policies. Prep Room Policies

Laboratory Biosafety Manual Contents

Revised EHS Biosafety. 1 Select appropriate containers/bags for autoclaving.

RealLine HCV PCR Qualitative - Uni-Format

Biosafety Program University of Colorado. BSL-1 Audit Checklist

GEORGIA INSTITUTE OF TECHNOLOGY ENVIRONMENTAL HEALTH AND SAFETY PERSONAL PROTECTIVE EQUIPMENT

Hazardous Waste Procedures

Bloodborne Pathogens Program Revised July,

Guidelines for the Management of Spillage of Cytotoxic Drugs. No changes have been made as evidence base remains current.

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

Biohazardous, Medical & Biological Waste Guidance Chart

INSTITUTIONAL POLICY AND PROCEDURE (IPP) Department: Manual: Section:

STANDARD OPERATING PROCEDURES Safe Autoclave Operations

Aseptic Technique. A GMP/GTP Training Module

BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

ASTCCR2 - SQA Unit Code H Carry out and complete clean-room cleaning operations

IX. Decontamination and Spills

Decontamination and Waste Management

Job Hazard/Safety Analysis For the Lab Worker

Microbiology Lab Practices and Safety Rules

Standard Operating Procedure

Required Biosafety Level Three (BSL-3) Practices, Procedures, Facilities, and Safety Equipment For BSL-3 and BSL3/2 Laboratories

Infectious Waste Management Plan

DNA Analyst Training Laboratory Training Manual Protocol 2.01 Quality Assurance

Texas Tech University Standard Operating Procedures Manual. Biosafety Level 2 Laboratory. of Dr. Boyd Butler

Crime Scene Unit Presumptive Testing Procedures. Evidence Collection Division

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

Adeno-Associated Viral Vectors

Applied Biosystems KRAS Mutation Analysis Reagents. Protocol

Aptima Specimen Transfer Kit

Introduction BIOMEDICAL WASTE

Minimizing Occupational Exposure to Hazardous Chemicals in Animal Protocols

CONTROLLING CROSS INFECTION IN THE DENTAL LABORATORY. Best Practice Guide

Fundamental Autoclave Techniques

FORENSIC BIOLOGY PROTOCOLS FOR FORENSIC STR ANALYSIS Approving Authority: Eugene Y. Lien, Technical Leader Nuclear DNA Operations

Use of Micropipettes

Guidance on safe use of Autoclaves

Knowledge and Awareness of Proper Waste Disposal and Routine Biosafety Measures Among HealthCare Workers in Karachi, Pakistan (JUW-BEP-BSAP Project)

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

PERSONAL PROTECTIVE EQUIPMENT (PPE)

4. Infection control measures

Biohazardous Waste Management Plan

Conservation of Momentum Greg Kifer

The Role of the Laboratory in Clinical Trials. Basma Elgamal, M.D. Professor of Clinical Pathology National Cancer Institute, Cairo University

CRIME SCENE REMINDER CARD. "Interview, Examine, Photograph, Sketch, Process"

Safety introduction. In the event of fire and accidents, you have a responsibility to know the location of:

Catalytic Activity of Enzymes

LAB 11 PLASMID DNA MINIPREP

6 Body Fluid Stains and Standards

The Control and Avoidance of Contamination In Crime Scene Examination involving DNA Evidence Recovery

Occupational Health and Safety in the Laboratory (Undergraduate Students)

BIOLOGICAL WASTE DISPOSAL (Biohazardous & Anatomical Wastes)

Safe Handling of Cytotoxic Materials

POLICY 08:18:00 BLOODBORNE PATHOGENS CONTROL PLAN

Leader s Guide E4017. Bloodborne Pathogens: Always Protect Yourself

Transcription:

DNA Analyst Training Laboratory Training Manual Protocol 2.02 Clean Technique This laboratory protocol (or part thereof) has been provided as an example of a laboratory SOP, courtesy of the Illinois State Police. It has been included for training and example purposes only.

INTRODUCTION All Forensic Biologists and DNA analysts must follow clean technique. The purpose of clean technique is to prevent unwanted DNA from entering a sample. The first line supervisor through the laboratory director is responsible for ensuring this policy is followed. There are many sources of contamination such as: aerosols, liquids or dry flakes/dust, unclean tools, unclean gloves, and contaminating materials on lab coats. There are also laboratory areas that are more at risk for the introduction of unwanted DNA such as evidence examination areas and extraction areas. Proper precautions must be taken to reduce the risk of contamination. SAFETY CONSIDERATION Observe Standard Laboratory Practices. Warning: Treat all reagents/samples as potential biohazards. Refer to safety considerations under the DNA Isolation/Methods section. Personal Protective Equipment (PPE) Gloves must be worn whenever an individual is handling equipment or instruments that are used for casework within the Forensic Biology/DNA laboratory. Forensic Biologist/DNA Analysts must wear a mask, gloves and disposable lab coat or reusable lab coat in conjunction with disposable sleeve covers while examining all items of evidence. The gloves must either be sterile or after putting the gloves on, they must be bleached with 10% bleach and dried. Gloves must be changed or bleached between exhibits. Gloves must also be changed after handling non-evidence items prior to returning to casework. These non-evidence items may include but are not limited to, refrigerators/freezers, biohazard waste bins, equipment, computers, and telephones. Gloves should be changed often. Personal Protective Equipment (PPE) in Post-PCR Disposable or designated lab coats must be worn in the post-pcr rooms and these lab coats must be worn only in the post-pcr rooms. Non-disposable lab coats must be removed from the laboratory for cleaning in a closed container. PREPARATION 10% Bleach Solution INSTRUMENTATION Standard Laboratory Instrumentation MINIMUM STANDARDS AND CONTROLS pdi_lab_pro_2.02.pdf President's DNA Initiative - DNA Analyst Training Page 1 of 4

Not applicable. PROCEDURE OR ANALYSIS General Information 1. Analysts should avoid taking phone calls when working in the laboratory. Conversations between laboratory personnel should be kept at a minimum when an analyst is working with evidence samples. 2. Tube openers should be used to uncap tubes (microcentrifuge tubes, Microcons, etc.). The tubes must be centrifuged prior to opening. Open only one tube at a time. Tube openers should be cleaned in a 10% bleach solution after each use. 3. Each analyst must use individual mini-stocks of each reagent. These mini-stocks may not be shared between analysts. Mini-stocks may be replenished from the large stock solution. 4. Do not pipette from a stock reagent bottle. Reagents must be poured from the stock reagent bottle into a disposable beaker. When finished, discard the beaker and its contents. All stock reagents must be closed when processing stains for extraction. 5. Exhibits will be processed one at a time. Only one exhibit will be open at a time. 6. The analyst will attempt to process unknown samples in an order from small or dilute samples to large or concentrated samples. 7. Unknowns must be processed first and separately from standards throughout the screening and DNA processes. Decontamination: 1. Decontaminate the surface on which samples are to be processed with a 10% bleach solution. Ensure the surface is dry before examining evidence. Make a new bleach solution daily. 2. All instruments which will be used to process forensic samples (e.g., forceps, scissors, centrifuge rotors, bone cutting equipment, pipetters and metal probes) must be decontaminated by autoclaving or rinsing with a 10% bleach solution. In addition, these items may be placed under an ultraviolet (UV) light source for at least 15 minutes. 3. Use a 10% bleach solution to rinse or wipe tools between samples. Tools may be rinsed with distilled water. After rinsing with a 10% bleach solution, use a disposable cloth to dry. Use a new disposable cloth each time. 4. Fresh paper must be used for each exhibit throughout the screening process. The work area must be bleached with a 10% bleach solution between each exhibit. The only exception to this procedure is during the examination of exhibits from a Criminal Sexual Assault (CSA) kit. pdi_lab_pro_2.02.pdf President's DNA Initiative - DNA Analyst Training Page 2 of 4

Sample Processing - DNA Extraction: 1. The process of examining DNA evidence, cutting samples for DNA extraction, and adding reagents will take place in a biohood, if available. The biohood provides a clean environment for DNA extraction and must have a hepa filter and a UV light. It must be cleaned throughly with a 10% bleach solution. All tubes that will be used in the extraction process must also be exposed to UV light for 30 minutes prior to their use. When finished, the biohood must be bleached with a 10% bleach solution. If a biohood is not available, the analyst may process samples on a freshly bleached bench top. Tubes that will be used in the extraction process must still be exposed to 30 minutes of UV light prior to their use. 2. A separate extraction process can be accomplished as follows: A. Extraction of standards and unknown samples can be conducted on different days or at different times. B. Extraction of standards and unknowns samples can be conducted in different biohoods. C. If samples are to be processed on the same day using the same hood, the analyst must keep the unknown samples and their manipulation blank(s) in their own rack and process them first. The standard samples and their manipulation blank(s) will be kept in their own rack and processed after the unknowns throughout the analysis, when applicable. 3. The order the samples are extracted and processed must be clearly documented in the case notes. This documentation must show the separate handling of the unknowns and their manipulation blank(s) from the standards and their manipulation blank(s). This can be accomplished by listing the samples in the order of extraction in the case notes along with the date the extraction is started. 4. For each extraction protocol followed, a sterile swab or piece of cotton material must be processed as a manipulation blank. A manipulation blank must be processed with each set of unknown samples and each set of standard samples (separate manipulation blanks). Process the manipulation blank identically to all of the other samples. Unknowns from different cases may be batched together with one manipulation blank for each extraction protocol used. Standards from different cases may also be batched together with one manipulation blank. 5. Exhibits will be processed one at a time. Only one exhibit will be opened at a time. Unknowns must be processed first and separately from standards throughout the DNA analysis. Unknowns will be cut, placed into tubes and placed into their own samples rack. A manipulation blank will then be cut for the unknown samples and added to the unknown samples rack. After the unknowns have been processed, the hood will be thoroughly bleached. The standards can then be cut, placed into tubes and placed into their own samples rack. A manipulation blank will then be cut for the known samples and added to the standard samples rack. pdi_lab_pro_2.02.pdf President's DNA Initiative - DNA Analyst Training Page 3 of 4

Amplification Set-up: 1. All amplifications must be set up in designated biohoods. If the face shield on the hood does not shield the analyst s face, the analyst must wear a face mask during amplification set up. 2. Pipetters that are dedicated for amplification set-up must be used. 3. The set-up biohood must be cleaned thoroughly with a 10% bleach solution. Any tubes that will be used in amplification set-up must be exposed to 30 minutes of UV light prior to their use. The biohood must be on during amplification set-up. 4. One master mix of amplification chemicals can be used for both unknown and standard samples. The amplification chemicals can be added to tubes in the rack of unknown samples and the tubes in the rack of standard samples. Close all tubes. Unknown samples and their manipulation blank(s) will continue to be contained within their own rack and processed prior to the rack of standard samples and their manipulation blank(s). The positive and negative amplification controls will be setup last. 5. All samples can be amplified at the same time using the same thermal cycler. Do not set the tube rack down in the post-amplification room while transferring samples to the thermal cycler. If the rack is set down, it must be bleached with a 10% bleach solution before being used in the main laboratory again. Post-Amplification: 1. After working with amplified DNA, an analyst must not work with any other biology or non-amplified evidence. 2. The door to the post-amp room must remain closed. 3. The sample preparation hood and pipetters must be cleaned with a 10% bleach solution before and after the samples are prepared. 4. The unknown samples and their manipulation blank(s) are prepared for injection first and separately from the standards and their manipulation blank(s), when applicable. Return to Laboratory Training Manual User Guide pdi_lab_pro_2.02.pdf President's DNA Initiative - DNA Analyst Training Page 4 of 4