Temperature Humidity Current Voltage Light
Kistock new range HVAC p.04 Laboratories p.07 Food industry p.08 Temperature / Humidity / Current / Voltage / Light C F ma V %RH lux 1 Configure 2 Measure/Record Easy, user-friendly configuration with KISTOCK software. USB 2.0 connection. Install the KISTOCK and required probes to measure and store data. 3 Download 4 Process/Print/Save Connect KISTOCK or KNT Data recorder to your PC and download all measurements in a few seconds. Fast, easy analysis of your measurement data using graphs and tables built thanks to KISTOCK software. 02
Data processing software KILOG Configuration of dataloggers In 3 steps, easily configure: - your instrument - your channels - your recording Data download 1 click and you can quickly download data from your KISTOCK or from the KNT data recorder. - automatic save - archive storage Data processing - creation of graphs and tables - automatic calculations - add calculation functions - export data to a spreadsheet KILOG CFR Data security KILOG CFR is the key software for users who require traceability under the strict standards of 21 CFR part 11 standard. Security and integrity of data are guaranteed - no possibility to modify or tamper with data. KILOG & KILOG CFR softwares are compatible with the former KISTOCK range. Kistock accessories Printer for KNT data recorder KNT data collector for mobile data transfer Anti-theft system wall-mounting bracket EN 12830 norm KT 150 and KT 250, models dedicated to food industry, meet with requirements of EN 12830 norm. This certification is required for transportation, storage and distribution of refrigerated, freezed and deep-freezed food, and ice cream (see page 8-9). Certification is done by an independent laboratory, COFRAC accredited. 03
Range for HVAC Class 110 Housing IP40 1 line display or without display Easy use Up to 3 parameters Up to 16,000 record points Temperature KT 110 I (internal measurement) KT 110 A (internal measurement + 1 input for external probe) Internal sensor Temperature........ -40 to +70 C Memory KT 110 I............ KT 110 A... 12,000 pts 16,000 pts Humidity, temperature & light KH 110 A (internal measurement) Internal sensors Humidity...5 to 95 %RH Resolution..............0.1 %RH Light............ 0 to 10,000 lux Resolution..................1 lux Temperature........ -20 to +70 C Memory............. 16,000 pts Magnetic mounting 04
Range for HVAC Class 210 Housing IP40 2-line display or without display Multi-probe Up to 5 parameters Up to 4 external inputs 20,000 record points Temperature KT 210 A (internal measurement + 4 inputs for external probes) Internal sensor Temperature........ -40 to +70 C Humidity, temperature & light KH 210 A (internal measurement + 2 inputs for external probes) KH 210 D (remote probe + 2 inputs for external probes) Internal sensor Humidity...5 to 95 %RH Resolution..............0.1 %RH Temperature........ -20 to +70 C Remote probe Humidity...5 to 95 %RH Resolution..............0.1 %RH Temperature........ -20 to +80 C Light............ 0 to 10,000 lux Resolution..................1 lux 05
Range for HVAC Class 310 Datalogger Housing IP54 2-line display Multi-probe 2 thermocouple external inputs 100,000 record points Thermocouple temperature KTT 310 (2 inputs for external probes) Thermocouple temperature K............. -200 to +1,000 C J............... -100 to +750 C T............... -200 to +400 C To prevent legionnaire s disease Check of hot water Sanitary network With Velcro probes or spring clamp probes, KTT 310 is a key instrument to control and monitor your hot water / sanitary network. Thermometer Function In addition to its datalogging function, KTT 310 allows you to perform on-demand display of measurements. 06
Range for Laboratories Class 350 IP65 2-line display Multi-probe Pt 100 temperature probes Up to 4 parameters 100,000 record points Pt 100 temperature KTR 350 (2 inputs for external probes) Pt 100 remote probes Temperature..... -100 to +400 C Thermometer Function Humidity & Pt 100 temperature KTH 350 A (internal measurement + 1 input for external probe) KTH 350 P (2 inputs for external probes - supplied with polycarbonate probe) KTH 350 I (2 inputs for external probes - supplied with stainless steel probe) Internal sensors Humidity...0 to 100 %RH Resolution..............0.1 %RH Temperature........ -20 to +70 C Thermo-hygrometer Function Stainless steel remote probe Humidity...0 to 100 %RH Temperature.......-40 to +180 C Polycarbonate remote probe Humidity...0 to 100 %RH Temperature.......-20 to +120 C 07
Range for Food industry Class 150 IP65 1 line display or without display Easy use Up to 3 parameters Up to 16,000 record points Temperature KT 150 I (internal measurement) KT 150 A (internal measurement + 1 input for external probe) Internal sensor Temperature........ -40 to +70 C Memory KT 150 I............ 12,000 pts KT 150 A... 16,000 pts New IP68 Special long-time immersion probes see p.11 IP67 Mini temperature dataloggers KT 20 G Temperature........ -40 to +85 C Memory............ 2,048 points KT 20 T Temperature.........0 to +125 C Memory............ 8,192 points KT 20 L Temperature........ -40 to +85 C Memory............ 8,192 points 08
Range for Food industry Class 250 IP65 2-line display or without display Multi-probe Up to 5 parameters Up to 4 external inputs 20,000 record points Temperature KT 250 I (internal measurement + 4 inputs for external probes) Internal sensor Temperature........ -40 to +70 C Humidity, temperature & light KH 250 A (internal measurement + 2 inputs for external probes) Internal sensors Humidity...5 to 95 %RH Resolution..............0.1 %RH Light............ 0 to 10,000 lux Resolution..................1 lux Temperature........ -20 to +70 C 09
Probes NTC temperature probes For HVAC Wire probes KCF 2 N Wire PVC cable -20 to +100 C KCG 50 N General use - stainless steel - 50 mm PVC cable -40 to +120 C KCG 150 N General use - stainless steel - 150 mm PVC cable -40 to +120 C KCA 150 N Ambient - stainless steel, perforated tip - 150 mm PVC cable -40 to +120 C KCV 200 N Velcro - length 200 mm PVC cable -20 to +90 C KCP 150 N Penetration - stainless steel - 150 mm PVC cable -40 to +120 C With polycarbonate handle KCG 150 PN General use - stainless steel - 150 mm PVC cable -40 to +120 C KCA 150 PN Ambient - stainless steel, perforated tip - 150 mm PVC cable -40 to +120 C KCP 150 PN Penetration - stainless steel - 150 mm PVC cable -40 to +120 C Current & voltage input cables KCTJ 10 N Voltage input cable PVC cable 0 to 10 V KCCJ 02 N Current input cable PVC cable 0 to 20 ma Ammeter clamps KPIJ xx N Ammeter clamps PVC cable 0 to 600 A For a wider choice of thermocouple probes for class 310 please contact us. 10
IP65 waterproof : splash proof IP68 waterproof : long-time immersion Pt 100 probes For laboratories Wires KRGA 50 General use - stainless steel - 50 mm IP 65 Teflon cable -50 to +250 C KRGA 150 General use - stainless steel - 150 mm IP 65 Teflon cable -50 to +250 C KRAM 150 Ambient - stainless steel, perforated tip - 150 mm Teflon cable -40 to +120 C KRVB 200 Velcro - length 200 mm Teflon cable -20 to +90 C KRPA 150 Penetration - stainless steel - 150 mm IP 65 Teflon cable -50 to +250 C With stainless steel handle KPI3 150 Penetration - stainless steel - 150 mm IP 65/68 Teflon cable -50 to +250 C KPIC3 150 Bent penetration - stainless steel - 150 mm IP 65/68 Teflon cable -50 to +250 C KTI3 100 Penetration with T-handle - stainless steel - 100 mm IP 65/68 Teflon cable -50 to +250 C KTBI3 100 Corkscrew twist - stainless steel - 100 mm IP 65/68 Teflon cable -50 to +250 C Current & voltage input cables KCTD 10 B Voltage input cable PVC cable 0 to 10 V KCCD 02 B Current input cable PVC cable 0 to 20 ma NTC probes - IP 65 For food industry Wires KCF 2 B Wire PVC cable -20 to +100 C KCG 50 B General use - stainless steel - 50 mm IP 65 PVC cable -40 to +120 C KCG 150 B General use - stainless steel - 150 mm IP 65 PVC cable -40 to +120 C KCA 150 B Ambient - stainless steel, perforated tip - 150 mm PVC cable -40 to +120 C KCV 200 B Velcro - length 200 mm PVC cable -20 to +90 C KCP 150 B Penetration - stainless steel - 150 mm IP 65 PVC cable -40 to +120 C With stainless steel handle KPI 150 Penetration - stainless steel - 150 mm IP 65/68 PVC cable -40 to +120 C KPIC 150 Bent penetration - stainless steel - 150 mm IP 65/68 PVC cable -40 to +120 C KPTI 100 Penetration with T-handle - stainless steel - 100 mm IP 65/68 PVC cable -40 to +120 C KPTBI 100 Corkscrew twist - stainless steel - 100 mm IP 65/68 PVC cable -40 to +120 C Current & voltage input cables KCTJ 10 N Voltage input cable PVC cable 0 to 10 V KCCJ 02 N Current input cable PVC cable 0 to 20 ma 11
Distributed by : Doc kistock - V2 - Anglais - 01/11 RCS (24) Périgueux B349 282 095 - Non-contractual document - We reserve the right to modify the characteristics of our products without prior notice. www.kimo.fr KIMO - Export Department Boulevard de Beaubourg - BP 48 Emerainville - F-77312 MARNE LA VALLEE Cedex 2 - France Tél. : +33 (0)1 60 06 69 25 - Fax : +33 (0)1 60 06 69 29 Email : export@kimo.fr