EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. www.lascarelectronics.com Page 1 of 5



Similar documents

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB mA Current Loop USB Data Logger

USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-500 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

USER S GUIDE Humidity and Temperature USB Datalogger

USB-500/600 Series Low-Cost Data Loggers and Accessories

Data Logging Solutions from Lascar Electronics

Temperature Datalogger Users Manual

Current Monitoring Kit

Data Loggers for Real Time Temperature Monitoring - WiFi

Current Monitoring Kit QUICK START GUIDE

DataView DVTH Data Logger for Temperature and Humidity

SupcoLog Logger Interface Software

TFA. KlimaLogg Pro. User Manual. Revision: 0.1

Datalogger Graph Software Help

User Guide. Temperature and Humidity Datalogger. Model 42280

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Wireless Data Logger Monitoring Systems

HOBO U14 Data Logger User Manual

4-Channel Thermometer / Datalogger

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

FT-1000/GPS-N. System of remote monitoring and control of physical

Single Use USB Data Logger EBI 330-T30 / EBI 330-T85. User Manual

SMS GSM Alarm Messenger

HOBO Single Channel Thermocouple Data Logger (UX M) Manual

Dual Laser InfraRed (IR) Thermometer

SA-9600 Surface Area Software Manual

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Temperature & Humidity SMS Alert Controller

USB-Based Temperature & Humidity Sensor

Manual. CANcaseXL CANcaseXL log. Version 5.1 English

is then retained absolutely without interruption.

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

USB Edition TM-STD30 User Guide

USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright Pico Technology Limited. All rights reserved.

Data Logger Basics For VFC Providers. Montana Immunization Program

iminiplus PDF User Guide Version 2.0

Instruction Manual. T3111 T3111L T3111P T3111Ex

Microwave Meter. Instruction Manual

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

GX-2009 Data Logger Management Program Operator s Manual

1. SAFETY INFORMATION

User Manual. SenseAir Alarm. Portable carbon dioxide sensor and alarm unit for personal safety with Real Time Clock

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Online Infrared Flue Gas Analyzer Gasboard 3000

SoundLAB Software Download Software from the Bogen website:

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

GSM HOME SECURITY SYSTEM

Preparing Log-ic 360 USB Loggers for Use

Guidelines for Storage and Temperature Monitoring of Refrigerated Vaccines

Inwall 4 Input / 4 Output Module

Test equipment for temperature and its reduction

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

User's Guide DylosLogger Software Version 1.6

RFID Logger Software User Manual Rev 1.0

Mini InfraRed Thermometer with Laser Pointer

RS DIGITAL THERMOMETER

S P E C I F I C A T I O N F O R L I T H I U M B A T T E R Y. M o d e l : C R

T0118 T2118 T3118. Instruction Manual

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

SubCue Analyzer Software - Introduction

Inwall Room Temperature Unit

STERILIZERS, LABORATORY DRYING OVENS

NoiseMeters. dosebadge. Monitoring Personal Noise Exposure

Model: Manual DC: WIRELESS COLOR FORECAST STATION

USER MANUAL V5.0 ST100

Hand-held thermometer Model CTH7000

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Temperature Humidity Meter

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

Temperature Alert. LAN-based Temperature and Humidity Data Logger

PTR/DTR. Printing Thermometer Software. Software User Manual

OT 40L / 90L. Laboratory Steam Sterilizers

BTMPico Data Management Software

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Integrating Sound Level Meter and Datalogger

Introducing AUDIT-BUDDY

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

Chapter 7 Event Log. Click the [Alarm (Event Log)] icon, and [Event Log] dialog appears as below:

Premium Server Client Software

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

Model UT201/202: OPERATING MANUAL. Table of Contents

Changers Kalhuohfummi User Manual

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Model SL355 Noise Dosimeter/Datalogger

HWg-STE HWg-STE PoE MANUAL

NortechCommander Software Operating Manual MAN R6

WD-AMX Water Detection Controllers

Manual Ranging MultiMeter

THUM - Temperature Humidity USB Monitor

Transcription:

This standalone data logger measures and stores up to 16,379 relative humidity and 16,379 temperature readings over 0 to 100%RH and -35 to +80 C (-31 to +176 F) measurement ranges. The user can easily set up the logger and view downloaded data by plugging the module into a PC's USB port and using the supplied software. Relative humidity, temperature and dew point (the temperature at which water vapour present in the air begins to condense) data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of temperature and humidity information. At the touch of a button, the user can cycle between the current temperature and humidity, along with the maximum and minimum stored values for temperature and humidity. The data logger is supplied complete with a long-life lithium battery, which can typically allow logging for up to 1 year. FEATURES 0 to +100%RH measurement range -35 to +80 C (-31 to +176 F) measurement range Dew point indication via Windows control software USB interface for set-up and data download User-programmable alarm thresholds for %RH & T Status indication via red and green LEDs High contrast LCD, with two and a half digit temperature and humidity display function Immediate, delayed and push-to-start logging Supplied complete with replaceable internal lithium battery and Windows control software WINDOWS CONTROL SOFTWARE Easy to install and use, the control software runs under Windows 2000, XP (Home and Professional Editions) and Vista (32-bit). It allows the user to set up and download data from any EL-USB product. The latest version of the control software may be downloaded from www.lascarelectronics.com DISPLAY FUNCTIONS Six different functions are available, which can be cycled through using the built-in push button. The most recent logged value, maximum logged value and minimum logged value can be displayed separately for humidity and temperature. In addition, logging and alarm status is shown using two high intensity LEDs. DATA LOGGER SETUP VARIABLES Logger name C, F Logging rate (10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms Immediate, delayed and push-to-start logging Display off, on for 30 seconds after button press, or permanently on Data rollover (Allows unlimited logging periods by overwriting the oldest data when the memory is full) ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD and Battery) Replacement Battery Stock Number EL-USB-2-LCD BAT 3V6 LASCAR ELECTRONICS LTD. LASCAR ELECTRONICS INC. LASCAR ELECTRONICS (HK) LIMITED MODULE HOUSE 4258 West 12th Street Unit Nos. 6-8, 19/F., Futura Plaza WHITEPARISH Erie 111-113 How Ming Street WILTSHIRE SP5 2SJ PA 16505 Kwun Tong, Kowloon UK USA Hong Kong TEL: +44 (1794) 884567 TEL: +1 (814) 835 0621 TEL: +852 2389 6502 FAX: +44 (1794) 884616 FAX: +1 (814) 838 8141 FAX: +852 2389 6535 E-mail: sales@lascar.co.uk E-mail: us-sales@lascarelectronics.com E-mail: saleshk@lascar.com.hk www.lascarelectronics.com Page 1 of 5

SPECIFICATIONS Specification Min. Typ. Max. Unit Relative Humidity Measurement range 0 100 %RH Repeatability (short term) ±0.1 %RH Accuracy (overall error) ±3.0* ±6.0 %RH Internal resolution 0.5 %RH Long term stability 0.5 %RH/Yr Temperature Measurement range -35 (-31) +80 (176) C ( F) Repeatability ±0.1 (0.2) C ( F) Accuracy (overall error) ±0.5 (1) ±2 (±4) C ( F) Internal resolution 0.5 (1) C ( F) Dew Point Accuracy (overall error) ±1.1 (±2)** C ( F) Logging rate every 10s every 12hr - Operating temperature range -35 (-31) +80 (176) C ( F) 1/2AA 3.6V Lithium Battery Life*** 1 Year * This specifies the overall error in the logged readings for relative humidity measurements between 20 and 80%RH. ** This specifies the overall error in the calculated dew point for relative humidity measurements between 40 and 100%RH at 25 C. *** Depending on sample rate, ambient temperature and use of LCD display. At temperatures below -20 C (-4 F) the LCD will exhibit slower response times of approximately 10 seconds. LED AND LCD INDICATORS The EL-USB-2-LCD features a high contrast LCD and two bi-colour LEDs. The LCD shows logged temperature and humidity values using seven segment numbers, along with annunciators. The LCD can also show information regarding the logging status. www.lascarelectronics.com Page 2 of 5

LCD status indicators: Display Logger status Explanation Delayed Start This is shown when the logger is set to start at a specific date and time* Push to Start This is shown when the logger is setup for push to start logging Logging This is shown when the logger is running in LCD off mode, and the button is pressed. The display clears again after three seconds Stopped If the logger has not been set to log and the button is pressed, three dashes are displayed for three seconds *If the logger is set to LCD off or LCD on for 30 seconds mode, then this will only be shown after the button is pressed. Otherwise the display will remain blank. The number of flashes and colours indicate: (Single LED, Single Flash) (Single LED, Double flash) (Single LED, Triple flash) The channel is logging, no alarm Delayed start Logger full, no alarm (Single LED, Single Flash) (Single LED, Double flash) (Single LED, Triple flash) The channel is logging, low alarm The channel is logging, high alarm Logger full, alarm www.lascarelectronics.com Page 3 of 5

LEDs Meaning Action No LEDs flash - No logging started. or - Battery fitted buy completely discharged. or - No battery fitted. Plug the data logger into the PC and run the control software to find out which condition applied. Alternating green double flash every 10 seconds Start logging. Replace battery. Fit battery, start logging. - Logger configured for delayed start. No action needed, logger will start at a later date and time. Alternating greens single flash every 10 seconds - Logger operating. - Last stored Humidity and Temperature readings within set alarm levels. (If hold is enabled, then a flashing Green LED indicates that no alarm condition has ever been logged). Alternating between green and red single flash every 10 seconds None. - The green LED indicates the parameter that is within set alarm levels. - The red LED indicates the parameter for which the Low alarm level has been exceeded. (If hold is enabled, then the alarm condition may have been triggered at any point during the current logging session). Alternating between single green and double red flash every 10 seconds - The green LED indicates the parameter that is within set alarm levels. - The red LED indicates the parameter for which the high alarm level has been exceeded. (If hold is enabled, then the alarm condition may have been triggered at any point during the current logging session). Alternating between green or red triple flash every 10 seconds Warning : Logger memory is full. In this condition, hold is automatically enabled, and a flashing Green LED indicates that no alarm condition has ever been logged. A Red LED indicates that an alarm condition has been logger. Download Data. Simultaneous red single flash every 60 seconds Warning : Battery is nearly discharged. No alarm conditions are indicated. Once the battery is exhausted, no LEDs will flash. Fit new battery and download data. www.lascarelectronics.com Page 4 of 5

DIMENSIONS All Dimensions in mm CAUTION Exposure of the internal sensor to chemical vapours such as those produced by some plastics and foamed materials may interfere with the internal sensor and cause inaccurate readings to be logged. In a clean environment, this will slowly rectify itself, therefore ensure that the logger is used in a ventilated area i.e. air exchange is allowed. Exposure to extreme conditions or chemical vapours will require the following reconditioning procedure to bring the internal sensor back to calibration state. 80 C (176 F) at <5%RH for 36h (baking) followed by 20-30 C (70-90 F) at >74% RH for 48h (re-hydration). High levels of pollutants may cause permanent damage to the internal sensor. www.lascarelectronics.com Page 5 of 5