Lab Exercise 3: Media, incubation, and aseptic technique



Similar documents
Transferring a Broth Culture to Fresh Broth

LAB 4. Cultivation of Bacteria INTRODUCTION

Lab Exercise 2 Media and Culture

Bacterial Transformation with Green Fluorescent Protein. Table of Contents Fall 2012

Transformation Protocol

BUGS" THAT PRODUCE DRUGS TO KILL "BUGS Microbes Produce Antibiotics

Potato Microbiology. Sarah Follenweider, The English High School 2009 Summer Research Internship Program

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

Microbiology Laboratory Safety and Basic Procedures Safety in a microbiology laboratory is important in the prevention of infection that might be

In order to be useful, a smear must have the following qualities:

COMMON LABORATORY APPARATUS

EUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS

BACTERIAL ENUMERATION

Mixtures and Pure Substances

National Food Safety Standard Food microbiological examination: Aerobic plate count

Experiment 12- Classification of Matter Experiment

PURE CULTURE TECHNIQUES. To demonstrate good aseptic technique in culture transfer or inoculation and in handling sterile materials.

DETECTION OF BACTERIAL MOTILITY. To demonstrate bacterial motility by microscopic and macroscopic techniques.

ENUMERATION OF MICROORGANISMS. To learn the different techniques used to count the number of microorganisms in a sample.

Culture Media Preparation Review ( Modified from Supplemental Lecture by Stephen T. Abedon)

EH&S. Sheet. Fact. Safe and Effective Use of Autoclaves. What are autoclaves? Factors for effective sterilization. Dry heat cycle - when to use

Chem 100 Lab Experiment #9 - ACID/BASE INDICATORS

Laboratory Biosafty In Molecular Biology and its levels

Aerobic Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Aerobic Count Plate

Transformation of the bacterium E. coli. using a gene for Green Fluorescent Protein

Biological Sciences Initiative

Result: COMPLETE Report Date: 08-OCT-2012

Welcome to Implementing Inquirybased Microbial Project. Veronica Ardi, PhD

Physical and Chemical Properties and Changes

Catalytic Activity of Enzymes

SEPARATION OF A MIXTURE OF SUBSTANCES LAB

Decontamination and Waste Management

MICROSCOPY OF LIVING MICROBES

Experiment 1: Colligative Properties

PREPARATION FOR CHEMISTRY LAB: COMBUSTION

Evaluation of Microbial Growth and Survival on Construction materials treated with Anabec NewBuild 30

Experiment 7: Titration of an Antacid

Agarose Gel Electrophoresis with Food Color- Teacher Guide

Environmental Monitoring

Rauserv Steam Sterilizers, Laboratory and Hospital Equipment. Brewery Laboratory Equipment

Recovery of Elemental Copper from Copper (II) Nitrate

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces

FACT SHEET : Using Autoclaves Safely

Sugar or Salt? Ionic and Covalent Bonds

Transformation Kit BACTERIAL TRANSFORMATION: GREEN FLUORESCENT PROTEIN. Partnership for Biotechnology and Genomics Education

SOLUBILITY OF A SALT IN WATER AT VARIOUS TEMPERATURES LAB

Quantifying Bacterial Concentration using a Calibrated Growth Curve

CHM 130LL: ph, Buffers, and Indicators

Biosafety Level 2 (BSL-2) Safety Guidelines

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

Biotechnology. Unit 2: Microbiological Techniques. Student Materials [HIGHER] Margot McKerrell. abc. Learning and Teaching Scotland

Agrobacterium tumefaciens-mediated transformation of Colletotrichum graminicola and Colletotrichum sublineolum

Laboratory Protocols Level 2 Training Course Serotypning of Salmonella enterica O and H antigen.

Science. NZQA Support Material Page 1 of 8. Unit standard version 1 Perform methods for animal tissue culture Level 6 Credits 5

Experiment 3: Extraction: Separation of an Acidic, a Basic and a Neutral Substance

ENVIRONMENTAL MONITORING

UTILIZATION of PLASMA ACTIVATED WATER in Biotechnology, Pharmacology and Medicine. JSC TECHNOSYSTEM-ECO Moscow, Russia April, 2009

Science in the Real World Microbes In Action

Gel Electrophoresis Teacher Instructions Suggested Grade Level: Grades 7-14 Class Time Required: 1 period (50 minutes)

ISOLATION OF CAFFEINE FROM TEA

or

Dusted! PROCESS SKILLS SCIENCE TOPICS VOCABULARY

A Guide to Managing Your Biological Waste at the University at Albany

Isolation of Starch degrading bacteria Enzymes in Action

Microbiological Evaluation of the STI Series 2000 Medical Waste Treatment Process

Coating and Extraction of Honeycomb Denuders

Metabolism: Cellular Respiration, Fermentation and Photosynthesis

Disc Diffusion Susceptibility Methods

Microbiology BIOL 275 DILUTIONS

Transformation of E.coli with pgal

STERILIZATION AND DISINFECTION

Standard Operating Procedure (SOP)

Total Aerobic Bacteria, Yeasts and Molds

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Laboratory- and sterilisation equipment HMC EUROPE

Effective Use of Autoclaves

LABORATORY ORGANIZATION

Biotechnology Explorer

Human Physiology Lab (Biol 236L) Digestive Physiology: Amylase hydrolysis of starch

STANDARD OPERATING PROCEDURES Safe Autoclave Operations

THE ACTIVITY OF LACTASE

Environmental Monitoring of Clean Rooms

Experiment 5 Preparation of Cyclohexene

Luminol Test PROCESS SKILLS SCIENCE TOPICS VOCABULARY

EXPERIMENT 15: Ideal Gas Law: Molecular Weight of a Vapor

Fundamental Autoclave Techniques

Green Fluorescent Protein (GFP): Genetic Transformation, Synthesis and Purification of the Recombinant Protein

OBJECTIVES: Visitors learn what an antioxidant is and how it behaves. They also learn how to test for the presence of vitamin C..

PLANT TISSUE CULTURE

Basic Practical Microbiology

Jennifer Cosgrove & Julie Ertmann Developer of Curriculum Unit

KGI MEDICAL WASTE MANAGEMENT PLAN

Steam Sterilization Cycles for Lab Applications

Experiment 8 Synthesis of Aspirin

Hazardous Waste Procedures

Policies. Prep Room Policies

RESTRICTION ENZYME ANALYSIS OF DNA

1. The Determination of Boiling Point

Transcription:

Lab Exercise 3: Media, incubation, and aseptic technique Objectives 1. Compare the different types of media. 2. Describe the different formats of media, plate, tube etc. 3. Explain how to sterilize it, and how to distribute it in different formats. 4. Produce Nutrient agar (NA) plates, NA slants, and Nutrient broths (NB)which will be used in subsequent lab periods. 5. Know the laboratory equipment and culture media needed to develop and maintain pure cultures 6. Carry out aseptic technique for the removal and transfer of microorganisms for culturing. 7. Correctly sterilize and flame transfer instruments and tubes. 8. Properly incubate culture media at the appropriate temperature for the organism and the length of incubation. Introduction I. Media Media Containers: Media can come in liquid forms called broths. If a solidifying agent like agar is added the broth, is now a solid media. Solid media is prepared into Petri plates or in tubes as slants or deeps. If a larger tube is filled with a solid media it is called a Pour and is used to pour the media into a plate at a later time. Slants Deeps Petri plate

Microbiology Media Preparation: Bacteria and fungi are grown on or in microbiological media of different types. The medium that is used to culture the microorganism depends on the microorganism that one is trying grow. Added certain substances to the medium can make it useful for selecting different types of organisms and differentiating between types as well. Sometimes a ph indicator may be added for differentiation of microbes based on their biochemical reactions: the indicators may turn one color when slightly acidic, another color when slightly basic. In this lab, your group will make media called nutrient broth and nutrient agar. These 2 media----one a liquid and the other a solid---are the exact same formula save for the addition of agar agar (really---agar agar), an extract from the cell walls of red algae. This particular medium will grow MOST bacteria that we use in lab. There are two general types of media. One is made with a chemical recipe. This medium is called a chemically defined media. Some of our media is made from extracts and digests of yeast, meats or other food sources. Since this type of medium has some unknown ingredients it is called complex media. It is really not very complex to make complex media: 1. rehydrate the powder form of the medium 2. stir and just bring to a boil the medium to get it all well dissolved 3. distribute the media into tubes or leave in flask for plates 4. autoclave to sterilize the tube media 5. autoclave the agar medium for plate production and then pour into sterile petri dishes and cool STERILIZATION AND THE AUTOCLAVE When microbiological media has been made, it still has to be sterilized because of microbial contamination from air, glassware, hands, etc. There will be thousands of bacteria reproducing in the media so it has to be sterilized quickly before the microbes start using the nutrients up. The sterilization process is a 100% kill, and guarantees that the medium will stay sterile UNLESS exposed to contaminants by less that adequate aseptic technique to exposure to air. Media sterilization is carried out with the autoclave, basically a huge steam cooker. Steam enters into a jacket surrounding the chamber. When the pressure from the steam is at a certain point in the jacket, a valve allows the steam to enter the chamber. The pressure will go up over 15 pounds per square inch (psi): at this point the timer begins to count down---usually for 15 minutes, depending on the type of media. The high pressure in a closed container allows the temperature to go above the highest temperature one could get by just boiling, around 121 C. Therefore, we general set the autoclave to sterilize at 121 C at, 15 psi for 15 minutes. Fifteen minutes is for most organisms (except some really hardy spore formers). The prepared media is distributed in different containers, depending on the form one is making. Broths, agar slants and deeps are put into tubes and then sterilized. A rack with agar slant tubes are laid on a slant, tilted after sterilizing to allow the agar to solidify in a slanted fashion. Agar medium to will be poured into plates is sterilized in a flask, and then poured afterward autoclaving. Not all media or solutions can be sterilized via an autoclave.

II. Incubation Cultivation chambers called incubators are used to grow microbes at a range of temperatures. In this lab, we have set incubators for two temperatures most commonly used as optimum temperatures by the microbes we work with: 25 C and 37 C. We also have an incubator set at 4 C (aka a refrigerator!) that can be used to store cultures that have already grown. Unless otherwise noted in a laboratory exercise, you should use the following guidelines for incubation: 2 day incubations- 37 C 5 day incubations- 25 C III. Aseptic techniques Aseptic technique refers to protocols and procedures you use to insure that no microbes contaminate your experiment and that the microbes you are working with do not contaminate you, your colleagues, or working environment, or your loved ones at home! Because microorganisms are ubiquitous, you need to assume that every environment is replete with them. This laboratory exercise will introduce you to the procedures required to ensure a safe and aseptic laboratory. Before beginning today s laboratory exercise, become acquainted with the terminology and techniques: Work area disinfection Before beginning any laboratory experiment, you must spray down the lab bench with a surface disinfectant, such as Cavicide. Saturate the bench with the solution and rub in to cover the area. Do NOT use paper towels to completely dry the surface, but instead let the disinfectant evaporate. A large portion of the disinfectant s ability to kill microbes is based on contact with the microbe itself. You must repeat this procedure at the end of every laboratory session. Transfer instruments- loops and needles Wire loops and needles are made from inert metals such as platinum. They are extremely durable and can be sterilized by incineration. To do this, place the loop or needle into the flame of a Bunsen burner (the hottest portion is in the blue flame). Allow the loop or needle to get red hot, and then remove. Make sure the transfer instrument is cool before inserting into a culture for inoculation. You will do this prior to any inoculation and after any inoculation. Culture tube flaming Prior to inserting a cooled transfer instrument into a culture tube, you need to remove the cap and flame the lip of the tube. This will help prevent contamination with transient and airborne microbes. You will do this before and after any contact with a transfer instrument. Culture tube inoculation To inoculate a culture tube, you must determine the type of culture tube being used and follow the appropriate protocol: Broth tube: using aseptic technique as outlined above, deliver microbes using a loop and twist several times to ensure microbes are deposited into liquid medium Agar slant: using aseptic technique as outline above, deliver microbes using a loop by swiping across surface of slant in a sinusoidal pattern from the bottom to the top. Agar deep: using aseptic technique as outline above, deliver microbes by using a needle and stabbing the deep down the center of the agar. Agar plates Solid agar media can also be placed in Petri dishes. These are never flamed, but care must be taken to avoid contamination with airborne microbes. Always work near an open flame and keep the lid on the

Petri dish as much as possible. When taking an inoculum from an agar plate, lift the lid slightly and touch the surface of the colony/ sample with your loop. Remember, microbes are microscopic! You do not need to scoop up a large chunk of bacteria to have enough to transfer. Too much can be problematic. In the next lab session, you will learn how to inoculate agar plates to get pure colonies. LAB EXERCISES I. Culture Media Group supplies 1 sleeve of plastic petri plates 1 small test tube rack 1 jar nutrient nutrient broth powder 12 blue caps 1 jar agar powder 12 green caps 1-1 liter Erlenmeyer flask 4 yellow caps 1 graduated cylinder 1 pipette pump 1 magnetic stir bar 1 pipette disposal cylinder 1 spatula 10 ml pipettes 28 medium test tubes large and small rack Protocol (see flowchart on board or below): 1. Prepare 500 ml of nutrient broth (read the label for grams of powder and then add 500 ml of di water in a 1 L flask 2. Just barely bring to a boil, all you need to do is completely dissolve the powder in the water. 3. Pipette 3 ml into 12 tubes, cap blue, place in small rack. 4. Add 7 grams of agar to remaining broth 5. Bring just to a boil, set on counter to cool 6. Pipette 4 ml into tubes cap green for slants and place in large rack. 7. Pipette 10 ml into tubes for pours use yellow caps to make pours and place in small rack. 8. Now have all autoclaved, flask, broths, future slants and deeps while autoclaving label plates with date, media and group 8. After autoclaving allow flask to cool for about several minutes before attempting to hold flask 9. Set the Petri dishes out, RIGHT SIDE UP (small side down), tops covering the dishes. 10. When you are ready to pour your plates, obtain your flask of agar and pour the plates. Cover the bottom of each plate approximately 2/3 of the way across, put on the lid and gently rotate the plate to distribute the agar across the entire dish bottom. Plate will be about a third to half full. 11. Allow all plates to stand until they are completely solidified. Once they have solidified, place them on the tray at the back counter. 12. Agar plates are always placed UPSIDE DOWN (bottom dish with agar on top), definitely so when you are incubating your cultures. Why are agar plates incubated upside down? Often you will see a bit of water condensation on the top of the agar plate, particularly when they have been at 37 degrees C. The water molecules are cohesive and tend to run together. If the plate was sitting right side up, the water droplets could then fall onto the agar, creating a kind of little lake on the agar plate and messing up your plates. Upside down plates prevents the condensation from dropping on the agar surface.

QUESTIONS: 1. What is a complex medium? 2. Why are ph buffers added to the growth media for microbes? 3. How can the temperature in the autoclave go above boiling temperature of 212 F? 4. Why do you have boil the agar solution BEFORE dispensing it into tubes? 5. At what temperature does agar solidify? II. Incubation Cultivation chambers called incubators are used to grow microbes at a range of temperatures. In this lab, we have set incubators for two temperatures most commonly used as optimum temperatures by the microbes we work with: 25 C and 37 C. We also have an incubator set at 4 C (aka a refrigerator!) that can be used to store cultures that have already grown. Unless otherwise noted in a laboratory exercise, you should use the following guidelines for incubation: 2 day incubations- 37 C 5 day incubations- 25 C III. Aseptic techniques Aseptic technique refers to protocols and procedures you use to insure that no microbes contaminate your experiment and that the microbes you are working with do not contaminate you, your colleagues, or working environment, or your loved ones at home! Because microorganisms are ubiquitous, you need to assume that every environment is replete with them. This laboratory exercise will introduce you to the procedures required to ensure a safe and aseptic laboratory. Before beginning today s laboratory exercise, become acquainted with the terminology and techniques: Work area disinfection Before beginning any laboratory experiment, you must spray down the lab bench with a surface disinfectant, such as Cavicide. Saturate the bench with the solution and rub in to cover the area. Do NOT use paper towels to completely dry the surface, but instead let the disinfectant evaporate. A large portion of the disinfectant s ability to kill microbes is based on contact with the microbe itself. You must repeat this procedure at the end of every laboratory session. Transfer instruments- loops and needles Wire loops and needles are made from inert metals such as platinum. They are extremely durable and can be sterilized by incineration. To do this, place the loop or needle into the flame of a Bunsen burner (the hottest portion is in the blue flame). Allow the loop or needle to get red hot, and then remove. Make sure the transfer instrument is cool before inserting into a culture for inoculation. You will do this prior to any inoculation and after any inoculation. Culture tube flaming Prior to inserting a cooled transfer instrument into a culture tube, you need to remove the cap and flame the lip of the tube. This will help prevent contamination with transient and airborne microbes. You will do this before and after any contact with a transfer instrument.

Culture tube inoculation To inoculate a culture tube, you must determine the type of culture tube being used and follow the appropriate protocol: Broth tube: using aseptic technique as outlined above, deliver microbes using a loop and twist several times to ensure microbes are deposited into liquid medium Agar slant: using aseptic technique as outline above, deliver microbes using a loop by swiping across surface of slant in a sinusoidal pattern from the bottom to the top. Agar deep: using aseptic technique as outline above, deliver microbes by using a needle and stabbing the deep down the center of the agar. Agar plates Solid agar media can also be placed in Petri dishes. These are never flamed, but care must be taken to avoid contamination with airborne microbes. Always work near an open flame and keep the lid on the Petri dish as much as possible. When taking an inoculum from an agar plate, lift the lid slightly and touch the surface of the colony/ sample with your loop. Remember, microbes are microscopic! You do not need to scoop up a large chunk of bacteria to have enough to transfer. Too much can be problematic. In the next lab session, you will learn how to inoculate agar plates to get pure colonies.

Lab Exercises II. Aseptic transfer Protocol: 1. Prepare lab bench by removing extraneous items and cleaning surface with table disinfectant. 2. Label all sterile tubes using proper technique and paper labels. 3. Sterilize your inoculating loop until it turns bright red. About 5 seconds should be fine. Allow cooling completely before proceeding. 4. With your free hand, obtain the proper E. coli culture. Use the little finger of your hand holding the loop to uncap the tube, and then pass the lip or mouth of the tube through the flame briefly. 5. Insert the cooled loop into the tube and pick up some of the culture (either touch the surface of a solid inoculum or insert into the liquid inoculum) and remove from the tube. 6. Flame the mouth of the tube as before and replace the cap. 7. Obtain proper sterile tubes, and using the same procedure as in step #4, flame the lip of the tube. 8. Insert the loop into the sterile tube and inoculate as per instructions for that particular medium type. (see Introduction to this lab exercise) 9. Flame the mouth of the tube as before and replace the cap. 10. Sterilize the loop by flaming. 11. Incubate tubes at the proper temperature, depending on the number of days before your next laboratory class. Do the following aseptic transfers: Inoculate from To sterile media 1. E. coli slant Agar slant 2. E. coli plate Broth tube 3. E. coli broth Agar slant 4. E. coli broth Broth tube 5. Sterile loop Sterile slant (to check your sterility) Data and observations 1. Did you successfully prepare uncontaminated media? What signs would indicate contamination? 2. Were all the transfers successful? 2. Was there any contamination in the transfer tubes? Discussion 1. What is a complex medium? 2. Why are ph buffers added to the growth media for microbes?

3. How can the temperature in the autoclave go above boiling temperature of 212 F? 4. Why do you have boil the agar solution BEFORE dispensing it into tubes? 5. At what temperature does agar solidify? 6. Provide three reasons why the use of aseptic technique is essential when handling microbial cultures in the lab. 7. How is air contamination prevented when an inoculating loop is used to introduce or take a bacterial sample to/from an agar plate? 8. Where and how should a label be written on an agar plate? What about on a test tube? 9. How should agar plates be incubated? Why?