Impact of Paint on Indoor Air Quality in Schools

Similar documents
Specification. Indoor Air Quality Management

File M C2 - Document DE/1 - Page 1/5 TEST REPORT. This document is a translation in the lab of original report M Document DE/2 in french

Emission Testing February 2015 LMS Energy Pty Ltd - Jilliby Plant

Safe Method of Use 7 HSNO Class Flammable Liquids

Silane Penetrating Waterproofing Treatments AND Changing VOC Regulations Presented By: Jerry Fulcher Advanced Chemical Technologies, Inc.

Pennsylvania Marcellus Shale Short- Term Ambient Air Sampling Project

Air Monitoring Guide 3500/3510, 3520/3530, 3550/3551

DuPont Surfaces. Suitable for both horizontal and vertical applications, Corian solid surfaces and Zodiaq

GC-3 Green Seal Environmental Criteria for Anti-Corrosive Paints

STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS VERSION 1.

VOC Reduction: A Pathway to Environmentally Friendly Interiors

IS800 Series. Technical Data Sheet IS802, IS803, IS808, IS Description. Key Features and Benefits. Typical Physical Properties

A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas

Safe Method of Use HSNO Class Flammable Liquids

Cartridge Change Schedule

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Indoor Air Comfort Test Report

Fans That Sense & Extract Volatile Organic Compounds and Humidity

INDOOR AIR QUALITY REASSESSMENT. Sgt. William H. Carney Memorial Academy 247 Elm Street New Bedford, Massachusetts

Innovation #9/12. of all Formaldehyde for up to

Series 2. Continuous monitoring of trace chemical vapours

STATUS REPORT ON THE ALISO CANYON GAS LEAK AND ITS IMPACT ON PORTER RANCH COMMUNITY

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants

Indoor Environmental Quality Management Plan

Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD

Caution: Children Breathing An overview of air pollution and idling vehicles at Colorado schools

Fact Sheet. Determining VOC/HAP Emissions From Sheetfed Offset Lithographic Printing Operations. By Gary A. Jones

Safety Data Sheet Customwood MDF

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Material Safety Data Sheet

Mold. Guidelines for New Jersey Residents. Understanding Mold Investigations & Remediation

How To Test For Contamination In Large Volume Water

Sulfuryl Fluoride Structural Fumigation

Draeger-Tubes and accuro Pump

STANDARD METHOD FOR MEASURING AND EVALUATING CHEMICAL EMISSIONS

ENVIRONMENTAL DATA SHEET

Air Quality in San Diego 2013 Annual Report

Tiangang TM BW-10LD (622)

COATINGS GREENFORMANCE

Technical Data SeaQueen

French national initiatives and participation in the EU harmonisation process

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Integrated Solar Radiant Systems

MATERIAL SAFETY DATA SHEET Page 01 of 05

Total Energy Recovery Wheel Contaminant Transfer Study. Report

3 Destructible Vinyl Label Material 7613T / 7930T

Thermal and Catalytic Oxidation Systems

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

1. PUBLIC HEALTH STATEMENT

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Copyright 2010 Pearson Education, Inc. Chapter Fourteen 1

Draft Healthy Home Environmental Assessment Principles

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

FLOOR TREATMENT 09610

Mold Preventing I nterior System

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

FANTASTIK SCRUBBING BUBBLES ALL PURPOSE CLEANER HEAVY DUTY

MAKING A BETTER MARK WITH INK JET As substrates, industry regulations and customer demands change, fluids are also evolving

SECTION POLISHED CONCRETE FINISHING

RULE FURTHER CONTROL OF VOC EMISSIONS FROM HIGH- EMITTING SPRAY BOOTH FACILITIES

Performance Assessment of EAGLE 5000 in Tobacco Smoke Environment. REPORT

Standard Operating Procedure

Building and Grounds Maintenance Checklist

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

How To Run A Gas Plant

Carpet Seam Sealer 8200

=========================================================================== Section 1 PRODUCT AND COMPANY IDENTIFICATION

Version 1. Print Date 12/01/2009 Revision Date 11/30/2009 MSDS Number SITE_FORM Number

BOOSTER FLUID SOLUTION I. PRODUCT IDENTIFICATION

SPILLS & SPILL KITS. Spills -General Guidelines:

Purification of reaction mixtures using flash chromatography.

Stachybotrys chartarum a mold that may be found in water-damaged homes

ISANE Isoparaffin Products

A. Product data. Unless otherwise indicated, submit the following for each type of product provided under work of this Section: SPECIFIER NOTE:

PRODUCT DATA SHEET DESCRIPTION:

SAFETY DATA SHEET Glen-Pak TM DNA purification cartridge (for use with disposable syringes) xx

WINDEX ORIGINAL GLASS CLEANER

IEQ Management Plan. Denver Museum of Nature and Science ECF Addition

SIGMAFAST 210. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

MATERIAL SAFETY DATA SHEET

WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS. HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE

Benzene and Natural Gas Production

Mold. Clean Up, Removal, Safety Concerns

DOW CORNING CORPORATION Material Safety Data Sheet

WATER DAMAGE INVESTIGATION. Massachusetts Department of Public Utilities 1 South Station Boston, Massachusetts

The photoionization detector (PID) utilizes ultraviolet

FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Material Safety Data Sheet

WATERPROOFING OF WET ROOMS

Pintura is a color coated glass product manufactured. by Pulp Studio, Inc, and is ideally suited for commercial

Guidance for Selecting a Contractor for the Installation of Spray Polyurethane Foam (SPF) in School Buildings

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Transcription:

Impact of Paint on Indoor Air Quality in Schools Marilyn Black UL-GREENGUARD Steve Revnew The Sherwin-Williams Company

SUMMARY The health and comfort of students and teachers are among the many factors that contribute to learning and productivity in the classroom, which in turn affect performance and achievement. Every effort is made to achieve good indoor air quality ( IAQ ) through proper design, construction and operation of a school. A typical cause of poor IAQ is volatile organic compounds or VOCs that originate from construction materials, furnishings, and finishes. Many VOCs can produce objectionable odors and cause irritation such as headache, eye tearing, and nasal burning. Paint, a common product that contributes VOCs into the air, is frequently used to refresh school appearance and improve surface durability. The VOCs associated with paints and coatings (e.g., formaldehyde, aldehydes, benzene, toluene, and xylene) can be either ingredients that are added to the paint to enhance product performance and shelf life or they can be byproducts of the paint drying process. In the fall of 2011, UL-GREENGUARD conducted two demonstration studies at a public middle school in Savannah, Georgia, to evaluate the impact that different types of paints have on IAQ in educational environments. The studies were a collaborative effort among UL s GREENGUARD Environmental Institute, The Sherwin-Williams Company ( Sherwin-Williams ), the Georgia chapter of the U.S. Green Building Council, and the Chatham County (Georgia) School District. The primary objective of the first school demonstration study was to compare airborne levels of VOCs when a conventional semi-gloss paint was used on interior wall surfaces versus a formulation of low VOC semi-gloss paint (VOC 50 g/l). The low VOC semi-gloss paint was compliant with the GREENGUARD Children and Schools emissions criteria and also met the recommended California chronic reference levels ( CRELS ) as traditionally specified in various green building programs. Airborne measurements of VOCs were made up to 14 days following painting. The data showed significant IAQ differences between the two paints studied in the school classrooms. The low VOC paint resulted in a greater than 90% reduction in total VOCs added to the air within 24 hours after application in comparison to the conventional paint. In addition, all of the VOCs associated with the low VOC paint were below detectable levels within 7 days whereas emissions of the conventional paint could still be observed in the air after 14 days. The second school demonstration study evaluated the impact of using Sherwin-Williams enhanced Harmony formulation with formaldehyde reducing technology (currently available in flat and eg-shel sheens) in school classrooms. Enhanced Harmony Paint was specially formulated to help promote better IAQ by reducing airborne concentrations of formaldehyde and other aldehydes. Use of enhanced Harmony Paint demonstrated a 45% reduction in a classroom airborne formaldehyde level whereas use of the conventional and low VOC semi-gloss paints did not demonstrate such a reduction. Additional laboratory studies confirmed airborne formaldehyde reduction with use of enhanced Harmony Paint containing formaldehyde reducing technology. KEYWORDS VOC emissions; paint emissions; school study; VOC exposure 2

1 INTRODUCTION IAQ in schools. Twenty percent of the U.S. population, or nearly 55 million people, spend their days in our elementary and secondary schools. Studies show that one-half of our nation's 115,000 schools have problems linked to IAQ. Young students in particular are at greater risk to exposure to indoor air pollutants because of the hours spent in school facilities, their biological susceptibility, and the inability to detect airborne hazards. Children breathe at a faster rate than adults; this coupled with their smaller body mass results in a higher dose of available pollutants for a child than an adult. Asthma remains the leading cause of school absenteeism and hospitalizations in children under the age of 15. In a recent study, for example, children aged 5 to 17 years with at least one asthma attack in the previous year missed 10.5 million school days in the aggregate that year. The health and comfort of students and teachers are among the many factors that contribute to learning and productivity in the classroom, which in turn affect performance and achievement. Every effort is made to achieve good IAQ through proper design, construction and operation of a school. A typical cause of poor IAQ is VOCs that originate from construction materials, furnishings, and finishes. Many VOCs can produce objectionable odors and cause irritation such as headache, eye tearing, and nasal burning. Studies have shown that children exposed to high levels of VOCs are four times more likely to develop asthma than adults (Rumchev et al, 2004). Other studies also have found an association between VOCs and asthma in children (CARB, 2005). The US Environmental Protection Agency ( USEPA ) and other public health advisories indicate one of the most effective ways of achieving good IAQ is source control, which involves the selection and use of low VOC building materials and processes that contribute minimal VOCs into the air. Source control, in combination with good building ventilation and controlled cleaning practices, can significantly reduce indoor air pollution and improve overall IAQ. Role of interior paints. Numerous products can contribute or off gas VOCs into the air including certain flooring types, cleaning chemicals, furniture, printers, ceiling systems, wall coverings, paint, adhesives and sealants, and art supplies. Paint products, a common source of VOCs, are frequently used to refresh school appearance and improve surface durability. The VOCs associated with paints and coatings (e.g., formaldehyde, aldehydes, benzene, toluene, and xylene) can be either ingredients that are added to the paint to enhance product performance and shelf life or they can be byproducts of the paint drying process. Currently, high quality, low VOC paint and coating products with desired performance characteristics are available for use in school environments. These types of paint and coating products minimize indoor air pollution loads and reduce health risks to both workers and occupants. School Demonstration Studies. In the fall of 2011, UL-GREENGUARD conducted two demonstration studies at a public middle school in Savannah, Georgia, to evaluate the impact that different types of paints have on IAQ in educational environments. The studies were a collaborative effort among UL s GREENGUARD Environmental Institute, Sherwin-Williams, the Georgia chapter of the U.S. Green Building Council, and the Chatham County (Georgia) School District. The primary objective of the first school demonstration study was to compare airborne levels of VOCs when a 3

conventional semi-gloss paint was used on interior wall surfaces versus a formulation of low VOC semi-gloss paint (VOC 50 g/l). In this first study, two separate classrooms were chosen to be painted, one with a conventional semi-gloss paint and one with a GREENGUARD certified low VOC semi-gloss interior paint satisfying the GREENGUARD Children and Schools chemical emission standards, including the California 1350 individual chemical requirements for chronic reference exposure levels (GEI-GGPS.002, 2011 and CDPH, 2010). Paint was applied to each room by the school s maintenance staff using standard practices. Paint was applied to the walls with rollers, and brushes were used to paint trim, edges and other finishing requirements. Each room was painted at a unique time, and care taken to ensure that ventilation systems among rooms were separate and did not introduce cross contamination. VOC testing of each room was conducted prior to the paint being applied and immediately following complete application. Periodic monitoring extended for 14 days following the initial paint application. Prior to application of these two paints in the school, laboratory emission profiles were determined for each paint using small environmental chambers following standard test and measurement protocols (ASTM D 5116, 2009 and GEI, GGTM.P066, 2011). Each paint was evaluated for the identification and quantitation of VOCs, extending out to 14 days. Each of the paints contained the same quantum of tint as to be applied in the school. In addition, a second school demonstration study was also conducted to evaluate the effectiveness of a new paint specifically formulated to reduce airborne concentrations of formaldehyde and other aldehydes. This new paint, Sherwin-Williams enhanced Harmony Paint, was also used to paint a comparative classroom. The measured IAQ in this classroom was then compared to that of the other classrooms painted with the conventional semi-gloss paint and the low VOC semi-gloss paint. 2 MATERIALS / METHODS Monitoring of VOCs. Airborne VOC samples were evaluated using gas chromatography with mass spectrometric detection ( GC/MS ). Chamber air was collected onto a sorbent tube which was thermally desorbed into the GC/MS. The sorbent collection, separation, and detection methodology had been adapted from techniques presented by the USEPA and other researchers. The technique followed standard measurement methods (USEPA Method IP1B, 1999 and ASTM D 6196, 2009) that are generally applicable to C6 - C16 organic chemicals with boiling points ranging from 35ºC to 250ºC. Measurements were reported to a quantifiable level of 1 µg/m³. A total VOC ( TVOC ) measurement was made by adding all individual VOC responses obtained by the mass spectrometer and calibrating the total mass relative to toluene. Individual VOCs were quantified to authentic standards if available; others were calibrated as toluene equivalents. Product Testing and Verification. All paint products applied in the first school demonstration study were chamber tested according to the GREENGUARD Standard Method for Measuring and Evaluating Building Materials, Finishes, and Furnishings Using Dynamic Environmental Chambers (GEI, GGTM.P066, 2011), as well 4

as standard guidance for VOC measurements using environmental chambers (ASTM D5116, 2010). The paints were applied to a standard wall substrate and emissions of VOCs were measured and identified. Data from the emissions tests were used to track VOCs found in the freshly painted classrooms. 3 RESULTS / DISCUSSION Environmental Chamber Emission Studies. Table 1 presents the TVOC levels measured from the conventional semi-gloss paint and the low VOC semi-gloss paint over a 14-day study period. The two paints remained in the environmental chamber during the complete study. In addition, the primary VOCs found emitting from each paint are presented in Table 2. Table 1. Chamber Emission Profiles TVOC MEASURED TIME POINT (hr) CONVENTIONAL PAINT EMISSION FACTOR (µg/m² hr) LOW VOC PAINT EMISSION FACTOR (µg/m² hr) 6 2172 286 24 502 32 48 272 7.7 72 155 2.1 96 127 2.0 168 90 --- 336 51 --- Table 2. Primary VOCs Measured from Paint Emission (Highest Emitting) CONVENTIONAL PAINT ANALYTE LOW VOC PAINT ANALYTE EMISSION FACTORS (µg/m² hr) 1-Hexanol, 2-ethyl 476 Undecane 29 Cyclotetrasiloxane, octamethyl 449 Ethylene glycol 23 2-Propenoic acid, 2-methyl-, 206 n-butyl ether 22 butyl ester (Butyl methacrylate) Acetic acid, 2-ethylhexyl ester 152 1,2-Propanediol (Propylene 18 glycol) 1-Butanol (N-Butyl alcohol) 134 Dipropylene glycol 17 1-Hexanol (N-Hexyl alcohol) 95 Dodecane 13 Ethanol, 2-(2-butoxyethoxy) 79 1-Propanol, 2,2'-oxybis- 11 Chloroacetic acid, 2-ethylhexyl 58 1-Propanol, 3,3'-oxybis- 9 ester Benzene, ethyl 49 Cyclohexane, 1-ethyl-2-9 propyl Xylenes 31 Cyclohexanone, 3-butyl- 9 EMISSION FACTORS (µg/m² hr) 5

Classroom VOC Field Studies. Airborne VOC levels in each classroom painted with the semi-gloss conventional and low VOC formulations were studied over a 14-day period following application of the paints. Initial measurements were made one hour following paint application. The primary VOCs (top 6) of each paint, as identified in the chamber emission studies, were individually tracked over time. The results for the conventional semi-gloss paint and the low VOC semi-gloss paint are presented below in Tables 3 and 4, respectively. While this first study was taking place, VOCs were also measured in the classroom painted with Sherwin-Williams enhanced Harmony Paint for comparison purposes. Results with respect to enhanced Harmony Paint are shown in Table 5. Table 3. Primary Paint VOCs Measured in Classroom after Painting Conventional Semi-Gloss Paint Concentrations (µg/m 3 ) ANALYTE TIME AFTER PAINTING 1 HR 24 HR 7 DAYS 14 DAYS Cyclopentasiloxane, decamethyl 380 121 26 16 Acetic acid, 2-ethylhexyl ester 250 35 18 12 1-Hexanol, 2-ethyl 230 35 8 3 2-Propenoic acid, 2-methyl-, butyl ester (Butyl 212 32 nd nd methacrylate) Cyclotetrasiloxane, octamethyl 190 61 15 8 nd - not detected Table 4. Primary Paint VOCs Measured in Classroom after Painting Low VOC Semi-Gloss Paint Concentrations (µg/m 3 ) ANALYTE TIME AFTER PAINTING 1 HR 24 HR 7 DAYS 14 DAYS 1,2-Propanediol (Propylene glycol) 19 2 nd nd Dipropylene glycol 14 3 nd nd n-butyl ether 13 nd nd nd Undecane 7 nd nd nd 1-Propanol, 2, (2-hydroxypropoxy) 4 nd nd nd nd - not detected ANALYTE Table 5. Primary Paint VOCs Measured in Classroom after Painting Enhanced Harmony PaintConcentrations (µg/m 3 ) TIME AFTER PAINTING 1 HR 24 HR 7 DAYS 14 DAYS n-butyl ether 11 nd nd nd Butyl propionate 6 nd nd nd 1-Butanol 4 nd nd nd Butylacetate 2 nd nd nd nd - not detected 6

Conventional Semi-Gloss Paint vs. Low VOC Semi-Gloss Paint Emission Study. Environmental chamber studies showed a significant difference in total VOC emissions between the conventional and low VOC semigloss paints studied and the length of time emissions were detected. The conventional semi-gloss paint showed initial TVOC levels approximately 8 times higher than the low VOC semi-gloss paint, with both exhibiting decreasing emissions over time. The low VOC semi-gloss paint reached non-detectable levels within 7 days and the conventional semi-gloss paint within 14 days. Individual VOCs varied among the two paints. Primary emissions of the conventional semi-gloss paint included various siloxanes, acrylates, alcohols and aromatic solvents, and the low VOC semi-gloss paint demonstrated emissions of glycols, other alcohols and numerous alkanes. Individual VOCs associated with the conventional semi-gloss paint were typically found at levels 10 times the magnitude of those measured in the low VOC semi-gloss paint. Laboratory VOC Reduction Study - Formaldehyde Reduction Measure External Laboratory Methodology. Data was obtained from dried paint films placed into inert chambers that were subsequently spiked with formaldehyde. The 7 mil (wet) paint films were prepared on aluminum panels and dried for 3 days under clean air conditions of 75 o F and 50% relative humidity. These paint panels were placed into Tedlar bags (10 liter) and 1% formaldehyde solution in water was injected into each bag to yield the appropriate equivalent air concentration (1, 10 or 100 ppm). At various time intervals, the formaldehyde present in each bag was measured with direct injection GC/MS or high performance liquid chromatography ( HPLC ) via derivatization in accordance with ISO-16000-3. Data for external calibration standards and the baseline for empty bags were measured with each series and used to determine actual formaldehyde levels and % reduction. The rate of formaldehyde reduction shown in the following 3 figures was measured by spiking the static bag with 1 ppm formaldehyde and then measuring the level over the next 2 days. There is significant reduction of formaldehyde in the empty bag at this low concentration Figure 1. Rate of formaldehyde reduction in an empty bag (calculated ppm) 7

A conventional paint, used as the control, lowers the level of formaldehyde in the chamber, but there is a slow release back to the environment over time as shown in Figure 2. Figure 2. Rate of formaldehyde reduction in the presence of conventional paint (calculated ppm) As indicated below in Figure 3, Sherwin-Williams enhanced Harmony Paint reduces the level of formaldehyde more quickly than conventional paint and to lower levels. In addition, enhanced Harmony Paint does not release the formaldehyde over time as was seen with the conventional paint. Figure 3. Rate of formaldehyde reduction in the presence of enhanced Harmony Paint (calculated ppm) 8

Studies were completed to determine if the reaction between formaldehyde and Sherwin-Williams enhanced Harmony Paint was reversible. This test was completed using 100 ppm of formaldehyde in a Tedlar bag. After 6 days of equilibration, the bag was purged, refilled with clean air, allowed to re-equilibrate for 3 days and then the level of formaldehyde was measured. This process was repeated to determine if formaldehyde would be released from enhanced Harmony Paint. The amount released was then compared to the amount released by an empty bag or the conventional paint. The results show that Sherwin-Williams enhanced Harmony Paint reduces the level of formaldehyde in the bag significantly more than the conventional paint. A slight amount of formaldehyde is lost to the surface of the empty chamber. The enhanced Harmony Paint absorbs nearly 4 times more formaldehyde than the conventional control paint as shown in Figure 4. Figure 4. Formaldehyde reduction (%) % Formaldeyde Reduction 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 100 ppm Formaldehyde Spiking Conventional Paint Enhanced Harmony Paint Empty Chamber Figure 5. Formaldehyde released (%) % of Total Reduction 100% 90% 80% 70% 60% 50% 40% 30% 20% Conventional Paint Enhanced Harmony Paint Empty Chamber 10% 0% 1st Purge 2nd Purge The actual data from the reversibility study is shown in ppm in Table 6. 9

Table 6. Formaldehyde released after purging with clean air (ppm) 100ppm to Start 1st Purge then 2nd Purge then PPM Formaldehyde 3-Day 3-Day Remaining Equilibrate Equilibrate Conventional Paint 79 10.7 3.2 Enhanced Harmony Paint 22 4.9 1.7 Empty Chamber 94 4.7 1.0 Blind validation testing was completed on samples using 10 ppm formaldehyde in a Tedlar Bag and allowing it to equilibrate for 3 days. Results are shown in Table 7. Similar results were obtained with tinted versus untinted samples. Overall, testing confirmed that enhanced Harmony Paint was effective in reducing formaldehyde at levels varying from 1 to 100 ppm. Table 7. Blind Validation Testing at 10 ppm Formaldehyde over 3 Days Paint Description Formaldehyde Reduction Enhanced Harmony Paint Batch Untinted 100% Batch Tinted 100% Conventional (Control) Paint 44% Alternate Methodology. This technique is similar to the external methodology, but involves the exposure of a cured paint film (48 hours dry at room temperature and humidity and cut to 1/4 inch diameter circle) to known concentrations of formaldehyde in sealed vials. The vials are left to equilibrate in an environmental chamber at 23 o C for 24 hours. The measurement of formaldehyde remaining in the vapor phase after exposure is completed by sweeping the headspace onto a formaldehyde absorbing cartridge for subsequent HPLC analysis. Figure 6 shows the amount of formaldehyde remaining in the gas phase after exposure to paint films. Each point of the graph is a separate vial exposed to increasingly higher levels of formaldehyde. At the lower levels, the total amount of formaldehyde added is completely consumed by the small volume of enhanced Harmony Paint, up to 200 ng/ml or approximately 150 ppm. Even when exposed to high levels of formaldehyde, the enhanced Harmony Paint consumes significantly more formaldehyde than a conventional paint. 10

Figure 6. Reduction of formaldehyde (ng/ml) Reduction of Formaldehyde in Gas Phase by Different Extra White Egshell Paints 800 Formaldehyde Concentration in Vial with Paint Present (ng/ml) 700 Enhanced Harmony Paint Conventional Paint 600 500 400 300 200 100 0 0 100 200 300 400 500 600 700 800 900 1000-100 Formaldehyde Concentration in Empty Vial (ng/ml) Another way to look at the data is shown in Figure 7. This graph shows the calculated amount of formaldehyde consumed by the paint film. Each point is a separate test at increasingly higher initial levels of formaldehyde. Enhanced Harmony Paint continues to consume formaldehyde up to 2000 ng/mg until the paint reaches saturation and then the formaldehyde starts to build up in the vapor phase. Figure 7. Calculated amount of formaldehyde reduction (ng/ml) Formaldehyde Concentration in Extra White Egshell Paint Film Versus Concentration in Gas Phase When Exposed to Different Levels of Formaldehyde 6000 Formaldehyde Concentration in Paint Film (ng/mg) 5000 Conventional Paint Enhanced Harmony Paint 4000 3000 2000 1000 0 0 100 200 300 400 500 600-1000 Formaldehyde Concentration in Gas Phase (ng/ml) 11

Dynamic Chamber Studies of Formaldehyde Reduction. Formaldehyde reduction studies were conducted by challenging both a low VOC paint (the control paint) and Sherwin-Williams enhanced Harmony Paint with dynamic air containing known concentrations of formaldehyde. Paint samples applied to wall board were prepared for the VOC emission chamber studies. These samples were placed in dynamic environmental chambers, and supplied with air containing known concentrations of formaldehyde. Constant formaldehyde concentrations were achieved with calibrated permeation tubes and maintained over a 7-day period for each of the chamber studies. Periodic air data was obtained across the 7-day period, and reduction measures were made by comparing the formaldehyde level in the chamber before and after introduction of the paint product. Net formaldehyde reduction was the difference from that obtained for the control paint and the enhanced Harmony Paint containing the formaldehyde reducing technology. Reduction was studied for a low and high concentration of airborne formaldehyde, 60 ug/m 3 and 500 ug/m 3, respectively. The 60 ug/m 3 (49 parts per billion or 49 ppb) value represents a typical indoor environment. Results as demonstrated in Table 8 indicate a measurable formaldehyde reduction with the enhanced Harmony Paint in comparison to the control low VOC paint at formaldehyde concentrations, averaging 15.7 % for 60 ug/m 3 and 19.1% for 500 ug/m 3. Reduction levels appear to equilibrate within 48 hours of formaldehyde exposure and hold constant throughout the 7-day test period as demonstrated in Figure 8. 12

Table 8. Formaldehyde reduction for control paint and enhanced Harmony Paint at two target concentrations Target Inlet Concentration Percent Formaldehyde Reduction Following Air Exposure 60 µg/m³ Control Paint 9.4% Enhanced Harmony Paint 25.1% Net Reduction 15.7% 500 µg/m³ Control Paint 7.8% Enhanced Harmony Paint 26.9% Net Reduction 19.1% Figure 8. 500 µg/m 3 Formaldehyde Target Challenge 600 Chamber Concentration (µg/m³) 500 400 300 200 100 0 0hr 24hr 48hr 72hr 96hr 120hr 144hr 168hr 17710-020AB Control Paint (500 µg/m³) 17710-030AB Enhanced Harmony Paint (500 µg/m³) 13

VOC Reduction in the Classroom. Measured VOCs in the classrooms painted with the conventional semigloss and low VOC semi-gloss paints were compared to those found in the classroom painted with Sherwin- Williams enhanced Harmony Paint. Measurements were made prior to painting and up to 336 hours following painting. The data showed a meaningful reduction of airborne formaldehyde, as demonstrated in Figure 9, for the classroom painted with enhanced Harmony Paint. Figure 9. Formaldehyde comparison across classrooms following application of various paints (µg/m 3 ) 35 30 Formaldehyde level µg/m 3 25 20 15 10 5 Conventional Semi-Gloss Low VOC Semi-Gloss Enhanced Harmony 0 pre 6 24 72 168 334 Time Prepaint and hours following painting 4 CONCLUSIONS The first school demonstration study showed that the low VOC semi-gloss paint contributed lower levels of VOCs to the air when compared to the conventional semi-gloss paint previously used by the school. The low VOC paint s highest contribution to the classroom air was propylene glycol at 19 ug/m 3. All other contributing VOCs were lower in concentration. In addition, all individual VOCs were less than 5 ug/m 3 within 24 hours after paint application, and there were no detectable paint emissions 7 days after application. In contrast, the conventional paint showed VOC contribution greater than 100 ug/m 3 for numerous VOCs, and some of these VOCs were still present in the classroom 14 days after paint application. Total VOC load and relative levels of VOCs can be an indicator of expected human comfort and acceptance of the air quality. Consequently, expectations of higher quality indoor air with lower chemical exposure and greater human comfort would be expected with use of a low VOC paint. Various laboratory methods confirm that Sherwin-Williams enhanced Harmony Paint with formaldehyde reducing technology can reduce the amount of formaldehyde from the gaseous phase near the paint. This was validated in the second school demonstration study conducted by UL-GREENGUARD. The second school demonstration study showed that airborne formaldehyde levels were significantly reduced in the classroom through use of enhanced Harmony Paint. The average 5-day airborne levels for each classroom prior to painting were compared to the 7-day (168 hour) average level after painting. There was a 45% reduction in 14

airborne formaldehyde in the room painted with enhanced Harmony Paint. In contrast, there was no reduction of formaldehyde level in the room painted with the conventional semi-gloss paint and a 9% reduction in the room painted with the low VOC semi-gloss paint. The 9% reduction was not significant since it was within the typical room formaldehyde concentration variation of 12%. 5 ACKNOWLEDGEMENTS The authors respectfully acknowledge the assistance of Ms. Leesa Carter, Executive Director of U.S. Green Building Council - Georgia in coordinating the project effort as part of the state of Georgia s High Performance Healthy School Program. In addition, we thank Mr. Michael Coon, Director of Facilities, and his staff at the Savannah-Chatham County Public School System, for providing school access and study support. Dr. Elliott Horner of Air Quality Sciences, Inc. of Atlanta, Georgia, coordinated building air testing and measurements. 6 REFERENCES ASTM D 5116, "Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products." ASTM, West Conshohocken, PA, 2010. ASTM D 6196 Practice for the Selection of Sorbents and Pumped Sampling/ Thermal Desorption Analysis Procedures for Volatile Organic Compounds in Air. ASTM, West Conshohocken, PA, 2009. CARB. Draft Report to the California Legislature: Indoor Air Pollution in California. California Air Resources Board. Sacramento, California. February 2005. CDPH/EHLB/Standard Method V1.1 Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions From Indoor Sources Using Environmental Chambers Version 1.1 dated February 2010. http://www.cal-iaq.org/vocs/standard-method EPA, Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air - Second Edition, (EPA/625/R-96/010b), Center for Environmental Research Information, Office of Research and Development, USEPA Cincinnati, OH, 1999. http://www.epa.gov/ttnamti1/files/ambient/airtox/tocomp99.pdf GGTM.P066, GREENGUARD Product Certification Program, Standard Method For Measuring And Evaluating Chemical Emissions From Building Materials, Finishes And Furnishings Using Dynamic Environmental Chambers, http://www.greenguard.org, 2010. GREENGUARD Environmental Institute, GREENGUARD Certification Standards for Low-Emitting Products for the Indoor Environment, GEI, Atlanta, Georgia, 2010. ISO 16000-3, Indoor air Part 3: Determination of formaldehyde and other carbonyl compounds Active sampling method International Organization for Standardization, Geneva, Switzerland, 2001. Rumchev K, Spickett J, Bulsara M et al. Association of domestic exposure to volatile organic compounds with asthma in young children. Thorax. 59: 746 751. 2004. 15