UniFlux 10: hollow fiber conversion kit (03-0089-67) installation instruction



Similar documents
CU-950 Installation Guide

Page finder. 1. Legal Handling Safety warnings and precautions Storage Expiry 4

UNICORN MS SQL Server Integration

GE Healthcare. UNICORN 5.2 vs Software Change Description

GE Healthcare. UNICORN 6.x. SQL Server 2008 configuration for UNICORN installations

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

How to Download a GE Healthcare License File

UNICORN. Hardening Guide

soft ware change description

ReadyKart Mobile Processing Station Instructions for Use

Gain efficiency in your process development with ÄKTA avant

Amersham High Molecular Weight Calibration Kit for native electrophoresis

GE Healthcare Life Sciences. Validation Services. Compliance support through life cycle management

GAMP5 - a lifecycle management framework for customized bioprocess solutions

Summary of GE Healthcare's Quality Management System (QMS) Covering BioProcess chromatography media, equipment, software, and spare parts

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

Instrument services for WAVE Bioreactor systems

DeCyder Extended Data Analysis (EDA) Software

His GraviTrap. GE Healthcare. Operation

HiTrap Heparin HP, 1 ml and 5 ml

UNICORN 7.0 software. Description. gelifesciences.com

Cord Blood Re-imagined The use of cord blood stem cells for clinical applications and medical innovations

Administration and Technical Manual

UNICORN control software

GE Healthcare s cell culture media, sera and process liquids

Smart Asset Management Services

Process-scale purification of monoclonal antibodies polishing using Capto Q

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Image Lab Software for the GS-900 Densitometer

Fast Trak Training & Education

How To Buy Eclipse Premium

We decided that we would build IFS Applications on standards so our customers would not be locked into any particular technology. We still do.

How does a venture capitalist appraise investment opportunities?

How To Build A Powerline Box Powerline Generator

illustra MicroSpin G-25 Columns

G8-VOIPREC. VoIP Recording Card G8-VOIPREC. Datasheet

Get the benefits of Norgren s unique range of Online services

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

WD Sentinel DX4000. Small Office Storage Server. Administrator s Quick Install Guide

Report on Government Information Requests

WD Sentinel DX4000. Small Office Storage Server Administrator s Quick Install Guide

White paper. Four reasons why you need to consolidate your packages

FiberOptix TM. AP Sensor Zeroing and Calibration Guide INTRA-AORTIC BALLOON PRODUCT SUPPORT HOTLINE. U.S. and Canada: IABP (4227)

WHITE PAPER WHY ENTERPRISE RESOURCE PLANNING SOFTWARE IS YOUR BEST BUSINESS INTELLIGENCE TOOL

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

GLOBAL DATA CENTER INVESTMENT 2013

Canada GO 2535 TM World Traveller's edition Maps of North America (Canada, US, Mexico), Western and Central Europe (including Russia) CAD 349,95

designed WORK IPGphor II First-Dimension Isoelectric Focusing System AA

ab vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use.

WHITE PAPER SIX ESSENTIAL CONSIDERATIONS WHEN CHOOSING A FIELD SERVICE SOFTWARE SOLUTION

Triple-play subscriptions to rocket to 400 mil.

Safety information...3 Important Information...3 Alert Signals...3 Introduction...4 General Usage...4 Principles of Operation...4 Installation...

Fax Getting Started Guide

Report on Government Information Requests

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

Release Notes: PowerChute plus for Windows 95 and Windows 98

Updating the QIAcube operating software

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

IFS ApplIcAtIonS For ElEctronIc components xxxxxxxxxxxxx

Blue Sepharose 6 Fast Flow

GLOBAL DATA CENTER SPACE 2013

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

4RU High Density Shelf Installation Instructions

Clinical and Laboratory Practices Workshops. Helping to improve laboratory skills and the quality of care in resource-limited settings

High-Speed Inter Connect (HSIC) Solution

Report on Government Information Requests

Connect Alias autosampler to ÄKTA pure or ÄKTA avant. Instructions

Offshore outsourcing of business services Threat or Opportunity

our service / Expertise Global Reach Financial Security Bespoke Approach Claims Management

PROPOSAL GENERAL BUSINESS AND PRODUCTS LIABILITY INSURANCE

Second Quarter and First Half 2015 Trading Update

How To Control A Record System

Supported Payment Methods

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

Biacore S200. Main applications. GE Healthcare. Label-free interaction analysis

Boston Scientific Spinal Cord Stimulation (SCS) Systems

Business Plan Calls Tariff The Choice for Business Telecoms

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Report on Government Information Requests

Supported Payment Methods

We decided that we would build IFS Applications on standards so our customers would not be locked into any particular technology. We still do.

E-Seminar. Financial Management Internet Business Solution Seminar

Advanced Software Upgrade Guide

Agilent Television Power Consumption Testing. Application Note

Health Care Systems: An International Comparison. Strategic Policy and Research Intergovernmental Affairs May 2001

How many students study abroad and where do they go?

Radiography & Fluoroscopy

Planned Healthcare in Europe for Lothian residents

Delegation in human resource management

Foods With Healthy Supplements and Organics Have Room for Growth

Brochure More information from

UK Television Exports FY 2014/2015

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

GfK PURCHASING POWER INTERNATIONAL

Transcription:

GE Healthcare Instruction 28-9052-35 AA UniFlux 10: hollow fiber conversion kit (03-0089-67) installation instruction Important! Before commencing with the installation, carefully read through this document. Please refer to the drawing included in Customer Binder in the hollow fiber conversion kit for details regarding different parts. Use appropriate personal protective equipment such as protective glasses, and gloves resistant to chemicals used. It is recommended to clean the system before starting installing the hollow fiber, for example by flushing the system with a non-hazardous solution. Scope This instruction provides information of how to reconfigure a UniFlux 10 from cassette to hollow fiber filter. There are two different hollow fiber sizes which can be used for UniFlux 10, Cartridge size 5 and Cartridge size 6. Note: To reconfigure a UniFlux 10 back to cassette from hollow fiber perform all steps in this instruction in reversed order. However, the hollow fiber drain valve can be left mounted on the system. Equipment required UniFlux 10 system equipped with cassette holder Workflow 1. Dismount the Cassette holder 2. Change position of Magnetic Flow Sensor and Pressure gauge 3. Mounting of piping and drip tray 4. Mounting and installation of Filter Drain valve 5. Mount hollow fiber 6. Define new settings in UNICORN 7. Test the installation WARNING! Ensure that the main power supply and compressed air supply are switched off before starting the installation. WARNING! The existing piping, tubing and filter cassette may contain hazardous solutions under pressure - please follow necessary precautions and use protective gear, such as protective glasses, and gloves resistant to chemicals used. WARNING! Dropping of any loosened parts during the hollow fiber conversion kit installation may cause personal injury. CAUTION! Dropping of any loosened parts during the hollow fiber conversion kit installation may cause instrument damage. Computer with control software UNICORN Hollow fiber Cartridge size 5 or Cartridge size 6 UniFlux 10 kit for conversion from cassette to hollow fiber

Support clams To facilitate the identification of different support clams used during conversion of UniFlux 10 from cassette to hollow fiber, pictures and references of support clams are listed in the Table below. Support clam picture Support clam reference (in this instruction / product number) SC1 / 03-0055-75 Comments This support clam is mounted when using UniFlux 10 with a cassette. It should be dismounted and not used when using hollow fiber. SC2 / 03-0058-40 SC3 / 03-0105-22 SC4 / 03-0058-37 SC5 / 28-4070-81 2 Instruction 28-9052-35 AA

1: Dismount the Cassette holder WARNING! The existing piping and filter cassette may contain hazardous solutions under pressure - please follow necessary precautions and use protective gear. Note: It is recommended to clean the system before starting installing the hollow fiber, for example by flushing the system with a with a non-hazardous solution. 1. Remove the drip tray (A). 3. Disconnect piping for Retentate (C), Permeate (D) and Inlet (E) and remove the cassette holder (F). WARNING! Dropping of any loosened parts during the hollow fiber conversion kit installation may cause personal injury. CAUTION! Dropping of any loosened parts during the hollow fiber conversion kit installation may cause instrument damage. C D E A F 2. Unscrew the 4 bolts (B) on the lower side of the Cassette holder. B B B B Instruction 28-9052-35 AA 3

2: Change position of Magnetic Flow Sensor and Pressure gauge 1. Disconnect piping at position (G). 2. Disconnect the support clam (SC1) from UniFlux 10 and piping. 3: Mounting of piping and drip tray 1. Place drip tray (DT), which is included in the hollow fiber conversion kit, as indicated. Note that it should be placed below the position of the hollow fiber, see Section 5. 2. Fasten support clams (SC2 and SC3) to indicated positions to the frame of UniFlux 10. SC2 DT G SC1 SC3 3. Remove pipe part (H) and support clam (SC1). H and SC1 are not used when the system is converted for hollow fiber. 4. Unfasten the Magnetic Flow Sensor (I) at position (J), turn it 180, and fasten it. SC1 3. Connect Magnetic Flow Sensor (I) at position (G), see step 1 in Section 2. 4. Fasten support clams (SC2 and SC3) to the piping. SC2 and SC3 should already be mounted to the frame of UniFlux 10 according to step 2, this Section. Adjust the support clams (SC2 and SC3) to fit the piping. Note: The arrow on the Magnetic Flow Sensor MUST be in the flow direction, i.e. point towards the hollow fiber. J H I I SC3 SC2 4 Instruction 28-9052-35 AA

4: Mounting and installation of Filter Drain valve 1. Mount the Filter Drain valve (K) with the Position Indicator (L) with support clam (SC4 ). L 5: Mount hollow fiber Note: There are two different sizes of hollow fiber for UniFlux 10. Follow instructions for either hollow fiber Cartridge size 5 (Section 5A) or size 6 (Section 5B). 5A: Mount hollow fiber Cartridge size 5 1. Connect the hollow fiber cartridge to the inlet (O) with a TC-clam. 2. Fix hollow Fibre with a support clam (SC5). K SC4 SC5 SC4 K O 2. Connect the cable from the Filter Drain Valve at position (M). The position is marked XV 064 valve. 3. Connect the tubing from the Filter Drain Valve at position (N). The position is marked XV 064 valve. 3. Connect drain flexible tube (P) 450 mm. P 4. Connect Permeate (Q) 550 mm and Retentate (R) 500 mm flexible tubes. M N R Q Instruction 28-9052-35 AA 5

5B: Mount hollow fiber Cartridge size 6 1. Connect the hollow fiber cartridge to the inlet (O) with a TC-clam, as described for step 1, hollow fiber Cartridge size 5 in section 5A. 2. Fix hollow Fibre with a support clam (SC5). 6: Define hollow fiber settings in UNICORN SC5 Fig. 1. UniFlux 10 flow scheme in UNICORN before installation of hollow fiber Cartridge. 3. Connect drain flexible tube (P) 450 mm. 1. Start UNICORN and open the UNICORN Manager window. 2. Select Administration:System Setup P 4. Connect Permeate (Q) 550 mm and Retentate (R) 500 mm flexible tubes. R 3. In the System Setup window, select desired system (System 1 in example) and click Edit Q 6 Instruction 28-9052-35 AA

4. In the Edit System window, click Component 7: Test the installation 1. Perform a functionality test of the Filter Drain valve using UNICORN. Open valves are indicated with green and closed valves are indicated with black. 2. Perform a leakage test under pressure (up to maximum pressure allowed for the hollow fiber used). Check all piping and connections for leakage. WARNING! Use a non-hazardous solution when performing the functionality test to avoid potential leakage of hazardous solutions. 5. In the Component window, check hollow fiber box and click OK. 6. In the Edit System window, click OK 7. In the System Setup window, click Close The hollow fiber is now added to the UNICORN software. To be able to control the hollow fiber from UNICORN strategies must include hollow fiber equipment. Fig. 2. UniFlux 10 flow scheme in UNICORN after installation of hollow fiber cartridge. The change is indicated. Instruction 28-9052-35 AA 7

www.gehealthcare.com GE Healthcare Bio-Sciences AB Björkgatan 30 751 84 Uppsala Sweden GE, imagination at work and GE monogram are trademarks of General Electric Company. UniFlux and UNICORN are trademarks of GE Healthcare companies. All goods and services are sold subject to the terms and conditions of sale of the company within GE Healthcare which supplies them. A copy of these terms are available on request. Contact your local GE Healthcare representative for the most current information. UNICORN. Any use of this software is subject to GE Healthcare Standard Software End-User License Agreement for Life Sciences Software Products. A copy of this Standard Software End-User License Agreement is available on request. 2007 General Electric Company All rights reserved. GE Healthcare Bio-Sciences AB, a General Electric company. GE Healthcare Bio-Sciences AB Björkgatan 30, SE-751 84 Uppsala, Sweden GE Healthcare Europe GmbH Munzinger Strasse 5, D-79111 Freiburg, Germany GE Healthcare UK Ltd Amersham Place, Little Chalfont, Buckinghamshire, HP7 9NA, UK GE Healthcare Bio-Sciences Corp 800 Centennial Avenue, P.O. Box 1327, Piscataway, NJ 08855-1327, USA GE Healthcare Bio-Sciences KK Sanken Bldg. 3-25-1, Hyakunincho, Shinjuku-ku, Tokyo 169-0073, Japan Asia Pacific Tel: +85 65 6 275 1830 Fax: +852 2811 5251 Australasia Tel: + 61 2 9899 0999 Fax: +61 2 9899 7511 Austria Tel: 01/57606-1619 Fax: 01/57606-1627 Belgium Tel: 0800 73 888 Fax: 03 272 1637 Canada Tel: 800 463 5800 Fax: 800 567 1008 Central, East, & South East Europe Tel: +43 1 982 3826 Fax: +43 1 985 8327 Denmark Tel: 45 16 2400 Fax: 45 16 2424 Finland & Baltics Tel: +358 (0)9 512 39 40 Fax: +358 (0)9 512 39 439 France Tel: 01 69 35 67 00 Fax: 01 69 41 96 77 Germany Tel: 0761/4903-490 Fax: 0761/4903-405 Italy Tel: 02 27322 1 Fax: 02 27302 212 Japan Tel: +81 3 5331 9336 Fax: +81 3 5331 9370 Latin America Tel: +55 11 3933 7300 Fax: +55 11 3933 7304 Middle East & Africa Tel: +30 210 9600 687 Fax: +30 210 9600 693 Netherlands Tel: 0165 580 410 Fax: 0165 580 401 Norway Tel: 815 65 555 Fax: 815 65 666 Portugal Tel: 21 417 7035 Fax: 21 417 3184 Russia & other C.I.S. & N.I.S Tel: +7 (095) 232 0250 Fax: +7 (095) 230 6377 South East Asia Tel: 60 3 8024 2080 Fax: 60 3 8024 2090 Spain Tel: 93 594 49 50 Fax: 93 594 49 55 Sweden Tel: 018 612 1900 Fax: 018 612 1910 Switzerland Tel: 0848 8028 12 Fax: 0848 8028 13 UK Tel: 0800 616928 Fax: 0800 616927 USA Tel: 800 526 3593 Fax: 877 295 8102 imagination at work Instruction 28-9052-35 AA 01/2007