Configuring and Launching ANSYS FLUENT 16.0 - Distributed using IBM Platform MPI or Intel MPI



Similar documents
Promap V4 ActiveX MSI File

1. CONFIGURING REMOTE ACCESS TO SQL SERVER EXPRESS

Distributing SMS v2.0

Nexio Connectus Cluster Set Up with SQL Server Backend

Important Notes for WinConnect Server ES Software Installation:

How to Configure Terminal Services for Pro-Watch in Remote Administration Mode (Windows 2000)

for Networks Installation Guide for the application on the server July 2014 (GUIDE 2) Lucid Rapid Version 6.05-N and later

Installation Manual (MSI Version)

Pearl Echo Installation Checklist

Active Directory Software Deployment

Tool Tip. SyAM Management Utilities and Non-Admin Domain Users

DigitalPersona Pro Server for Active Directory v4.x Quick Start Installation Guide

Configuring Network Load Balancing with Cerberus FTP Server

Immotec Systems, Inc. SQL Server 2005 Installation Document

Nexio Connectus with Nexio G-Scribe

Important Notes for WinConnect Server VS Software Installation:

Set Up Setup with Microsoft Outlook 2007 using POP3

Virtual Office Remote Installation Guide

Backing Up and Restoring Microsoft Exchange Server Cloud Attached Storage. August 2012 Version 3.2

Introduction. Before you begin. Installing efax from our CD-ROM. Installing efax after downloading from the internet

Sage HRMS 2014 Sage Employee Self Service Tech Installation Guide for Windows 2003, 2008, and October 2013

Creating client-server setup with multiple clients

Video Administration Backup and Restore Procedures

Installation Guide: Delta Module Manager Launcher

ContentWatch Auto Deployment Tool

Guide to Installing BBL Crystal MIND on Windows 7

Migrating MSDE to Microsoft SQL 2008 R2 Express

VERITAS Backup Exec TM 10.0 for Windows Servers

BusinessObjects Enterprise XI Release 2

Installation Instruction STATISTICA Enterprise Server

Kepware Technologies Remote OPC DA Quick Start Guide (DCOM)

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

...2. Standard Installation...4. Example Installation Scenarios...5. Network Installation...8. Advanced Settings Product Requirements

Network Printing In Windows 95/98/ME

FTP Server Configuration

QUANTIFY INSTALLATION GUIDE

PC Power Down. MSI Deployment Guide

Ascend Interface Service Installation

Installing Cobra 4.7

SQL Server Setup for Assistant/Pro applications Compliance Information Systems

Cloud Services ADM. Agent Deployment Guide

Xactimate v.27 Network Installation

Setting up DCOM for Windows XP. Research

JAVS Scheduled Publishing. Installation/Configuration... 4 Manual Operation... 6 Automating Scheduled Publishing... 7 Windows XP... 7 Windows 7...

STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS

Sage HRMS 2012 Sage Employee Self Service. Technical Installation Guide for Windows Server 2003 and Windows Server 2008

Install SQL Server 2014 Express Edition

Installation Instruction STATISTICA Enterprise Small Business

Error: "Object reference not set to an instance of an object" When Opening Any Database

isupplier PORTAL ACCESS SYSTEM REQUIREMENTS

Web Deployment on Windows 2012 Server. Updated: August 28, 2013

SARANGSoft WinBackup Business v2.5 Client Installation Guide

BioWin Network Installation

SAS 9.3 Foundation for Microsoft Windows

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

4cast Client Specification and Installation

To install the SMTP service:

INSTALLATION INSTRUCTIONS FOR UKSSOGATEWAY

Insight Video Net. LLC. CMS 2.0. Quick Installation Guide

Security Guidelines for MapInfo Discovery 1.1

HP Client Automation Standard Fast Track guide

Geomatica 10.2 Floating License Server Installation Procedures

Installation and Deployment

SSL Installing your new Certificate

Using Logon Agent for Transparent User Identification

Configuring Your Firewall for Client Access in Professional Edition

Troubleshooting Guide

Universal Management Service 2015

Installation Guide - Client. Rev 1.5.0

for Networks Installation Guide for the application on the server August 2014 (GUIDE 2) Lucid Exact Version 1.7-N and later

File and Printer Sharing with Microsoft Windows

Installation Troubleshooting Guide

For Active Directory Installation Guide

Mercy s Remote Access Instructions

Sophos Anti-Virus for NetApp Storage Systems startup guide

Lab - Configure a Windows 7 Firewall

GlobalSCAPE DMZ Gateway, v1. User Guide

for Networks Installation Guide for the application on a server September 2015 (GUIDE 2) Memory Booster version 1.3-N and later

LifeCyclePlus Version 1

Snow Active Directory Discovery

Installation Instructions Release Version 15.0 January 30 th, 2011

Active Directory Management. Agent Deployment Guide

LICENSE MANAGER VERSION 7.2. Procedures for Use of Sentinel LM7.2 Server for CHEMCAD. rev

Install MS SQL Server 2012 Express Edition

NSi Mobile Installation Guide. Version 6.2

In this lab you will explore the Windows XP Firewall and configure some advanced settings.

CODESOFT Installation Scenarios

NetIQ Advanced Authentication Framework. FIDO U2F Authentication Provider Installation Guide. Version 5.1.0

Freshservice Discovery Probe User Guide

NETWRIX FILE SERVER CHANGE REPORTER

INSTALLING AND USING ENTEL PROGRAMMER IN WINDOWS 7 Technical Support Bulletin

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

How to Install and Setup IIS Server

AlphaCard ID Suite Small Business Server Installation Guide

DriveLock Quick Start Guide

Troubleshooting File and Printer Sharing in Microsoft Windows XP

SafeWord Domain Login Agent Step-by-Step Guide

How To Create An Easybelle History Database On A Microsoft Powerbook (Windows)

TECHNICAL SUPPORT GUIDE

Transcription:

Configuring and Launching ANSYS FLUENT 16.0 - Distributed using IBM Platform MPI or Intel MPI Table of Contents BEFORE YOU PROCEED... 1 Launching FLUENT Using Shared Memory... 2 Configuring FLUENT to run across Multiple Computers (Distributed Memory)... 2 Sharing a Directory... 2 Mapping a Network Drive... 3 Installing the Message Passing Interface (MPI)... 3 Installing IBM Platform MPI or Installing INTEL MPI... 3 Installing IBM Platform MPI... 5 Issue We Have Seen and Best Practices... 8 Launching FLUENT... 8 Troubleshooting... 10 Firewalls... 10 BEFORE YOU PROCEED ANSYS Fluent runs using MPI (required for running on more than one computer) must be members of an Active Directory domain and the same Active Directory domain. Trying to run Fluent or any ANSYS solvers requiring MPI on more than one computer and being in a WORKGROUP environment instead of a DOMAIN will not work and is not supported by the MPI vendors or ANSYS. Active Directory is used by the MPIs for username/password authentication for security purposes. Before you proceed check your system to make sure you are a member of a Domain. Open up Control Panel > System, look for the term Domain with a domain name. If you see the word WORKGOUP do not proceed and contact your IT folks about adding your computer to Active Directory. 1

1. Go to Control Panel > System to check if your computer is a member of a WORKGROUP or DOMAIN NOTE: The steps listed in this document are for running FLUENT across multiple computers ONLY not for running on multiple processors on the same computer. Some of these steps require administrator privileges. Please contact your Systems Administrator for assistance. Launching FLUENT Using Shared Memory To launch FLUENT using multiple processors (Shared Memory) on the same computer select parallel in the FLUENT Launcher and then choose the number of processors. There is no need to install or configure an MPI. NOTE: If you are just running Fluent on one computer there is no need to proceed further Configuring FLUENT to run across Multiple Computers (Distributed Memory) 1. Install FLUENT (it is only necessary to install FLUENT on the submit machine). The default location will install FLUENT in C:\Program Files\ANSYS Inc\v160\fluent 2. Share the ANSYS Inc directory located by default at C:\Program Files\ANSYS Inc o that all computers on the cluster can access this shared directory through the network. Make sure you give Full Control. Sharing a Directory 1. Right-click on the ANSYS Inc directory located at C:\Program Files\ANSYS Inc 2. Go to Properties (Not Share With) 3. Choose the Sharing tab > Advanced Sharing. 4. Check Share this Folder 5. Select the Permissions button 6. Choose Full Control 7. Create a working directory on any computer that you will be launching Fluent from. (A working directory is the directory where your case and data files reside) 8. Share your Working directory giving Full Control for permissions. (same instructions as above) 9. Map a Network Drive letter to the shared Working directory. (The mapped drive letter (Z: in my example below) will be used in the FLUENT Launcher) 2

Mapping a Network Drive 1. Click Windows Start Button, Computer 2. Click Map network drive 3. Select the Drive Letter 4. Type the name of the computer using this format: \\computer_name\share_name (where computer name is the name of your computer and the share_name is the ANSYS Inc share that you created earlier). 5. Click Finish when finished. Installing the Message Passing Interface (MPI) IBM Platform MPI is the default MPI so we recommend that you install this MPI. Ensure that you have properly installed and configured the necessary Message Passing Interface (MPI). IBM Platform MPI (PCMPI) or INTEL MPI. An MPI is needed for sending data packets back and forth to the nodes. The MPI must be installed on all computers that you want to submit solve jobs to. Installing IBM Platform MPI or Installing INTEL MPI 1. To install the MPI choose the setup.exe file from the ANSYS Installation. 2. Choose "Install MPI for ANSYS Parallel Processing" 3

4

Installing IBM Platform MPI Choose Service Mode 5

This is the default Firewall port that IBM Platform MPI will use is 8636. Please add this port to the Firewall Exceptions list if applicable. 6

Proceed through the installation Restart your computer. If you have already installed ANSYS Fluent you can run the MPI installer manually by following the steps below following the steps above once the installer has started. Platform MPI (assuming the default installation location) 1. Open up Windows Explorer or File Explorer 2. Browse to C:\Program Files\ANSYS Inc\v160\commonfiles\MPI\Platform\9.1.2.1\Windows (do not choose the winx64 directory) 3. Run PlatformMPI-09.1.2.1r.w64.exe (right-click Run as Administrator ) Intel MPI (assuming the default installation location) 1. Open up Windows or File Explorer 7

2. Browse to C:\Program Files\ANSYS Inc\v160\commonfiles\MPI\Intel\4.1.3\Windows (do not choose the winx64 directory) 3. Run w_mpi-rt_p_4.1.3.045.exe (right-click Run as Administrator ) MORE NOTES: 1. If running on one machine you DO NOT need to install the MPI 2. If you choose to install Intel MPI follow the same instructions except choose Install Intel MPI. Issue We Have Seen and Best Practices 1. Using an installation shared from a Windows XP machine you may see random issues in parallel startup. This is due to Windows setting a very tight limit, 10, for network file connections, which is very easy to exceed. Users are recommended to install ANSYS on a Windows server OS machine and share from this machine. 2. MPIs are sensitive to network issues, different processor levels, memory speeds, operating systems, etc. So the things to check are: 1. Are all computers on a DOMAIN? MPI s require Active Directory Authentication. 2. Do all of the Workstations have the same processor type? 3. The same Memory Speed? 4. The same Operating System? 5. If you answered NO, to any of these questions, contact ANSYS Support for Best Practices and guidance Launching FLUENT 1. Launch FLUENT from Start Menu, All Programs, ANSYS 16.0, Fluid Dynamics, FLUENT 2. Select Parallel under Processing Options and then enter the number or Processes you will be using. 3. Choose "Show More Options". 8

4. On the General Options tab use UNC format for the FLUENT_Root Path to point to \\your_machine_name_\share_name that you set up in the Sharing a Directory section above. 5. In the Working Directory field type in the mapped drive letter you set up in the Mapping a Network Drive section above. 9

6. Select the Parallel Settings tab. NOTE: Do NOT choose "msmpi". This mpi is used exclusively when running Microsoft HPC 2008 OR 2012 Server only. Choose "Distributed Memory on a Cluster" followed by "File Containing Machine Names" 1. On the Parallel Settings tab choose File Containing Machine Names 2. Click the create file icon on the right and type in the name(s) of the computers you want to run distributed on. You only have to type the machine name once. In the example above, you have chosen to run on 16 cores. The machine file would be read and run 8 cores on Computer1 and 8 cores on Computer2. 3. Select OK to start Fluent. Troubleshooting Firewalls If you have a corporate Firewall turned on then you will not need the local Windows Firewall turned on. If you get a port error with port 8636 in the Fluent window then you will need to disable the Firewalls on all computers or add port 8636 to the Exceptions (This is the IBM Platform MPI default port) Please see Solution # 2029819 on the ANSYS Customer Portal for more troubleshooting information 10