PRACTICE BULLETIN ACOG

Similar documents
Doppler Ultrasound in the Management of Fetal Growth Restriction Chukwuma I. Onyeije, M.D. Atlanta Perinatal Associates

Obstetric Guideline 6B ELECTRONIC FETAL MONITORING IN LABOUR, SCALP SAMPLING, & CORD BLOOD GASES

Umbilical Artery Doppler Waveform Indices in Normal Pregnancies

Obstetrical units should develop a procedure for archiving the fetal monitoring tracings within their own institution.

A8b. Resuscitation of a Term Infant with Meconium Staining. Session Summary. Session Objectives. References

Cord Blood Erythropoietin and Markers of Fetal Hypoxia

Applications of Doppler Ultrasound in Fetal Growth Assessment. David Cole

Article. Anthony O. Odibo, MD, Christopher Riddick, Emmanuelle Pare, MD, David M. Stamilio, MD, MSCE, George A. Macones, MD, MSCE

CONFIDENT CODING FOR OB/GYN CONFIDENT CODING FOR OB/GYN

ST Segment Analysis (STAN) as an Adjunct to Electronic Fetal Monitoring, Part II: Clinical Studies and Future Directions

SWISS SOCIETY OF NEONATOLOGY. Umbilical cord complications in two subsequent pregnancies

Newborn outcomes after cesarean section for fetal distress in BC

Cerebral Palsy An Expensive Enigma

Evaluation of cardiotocographic and cord blood changes in induced labor with dinoprostone and misoprostol

Fetal Acid Base Status and Umbilical Cord Sampling. David Acker, MD

Measurement of fetal scalp lactate to determine fetal well being in labour

FETAL SCALP LACTATE RESEARCH STUDY COMPARISON OF TWO POINT OF CARE METERS

1 NCC Monograph, Volume 3, No. 1, 2010

Assessment of Fetal Growth

as severe fetal growth restriction worsens

TIMING OF ASPHYXIAL INJURY AND BIRTH TRAUMA

ROLE OF DOPPLER STUDY IN THE EVALUATION OF INTRAUTERINE GROWTH RETARDATION G. V. Prasad 1, Jyothi 2, Sarvottam 3

Correlation of Fetal Heart Rate Tracings and Scalp Stimulation Test in Labor with Cord Blood ph and Perinatal Outcome

Assessing the at-risk fetus: Doppler ultrasound Camille Hoffman and Henry L. Galan

THE LABOUR ADMISSION CTG An assessment of the test s predictive values, reliability and effect How the test is perceived by practicing midwives

Differentiation between normal and abnormal fetal growth

Second stage fetal heart rate patterns and neonatal acid-base status Faridah Hanim Zam Zam 1, Nazimah Idris 2, Tham Seng Woh 1

Clinical Policy Title: Home uterine activity monitoring

Correlation between Umbilical Cord ph and Apgar Score in High Risk Pregnancy

ABSTRACT LABOR AND DELIVERY

Umbilical Arterial Blood Gas and Perinatal Outcome in the Second Twin according to the Planned Mode of Delivery

Advanced Fetal Assessment and Monitoring: Online Program. Advanced Practice Strategies, LLC

BIRTH INJURY AND NEWBORN BRAIN DAMAGE

C. P. Noel McCarthy, MD Risk Reduction Strategies in Risk Obstetrics & Gynecology

How To Compare Pregnancy Complications With Pregnancy And Labor

Delayed Cord Clamping

Vanderbilt University Medical Center Policy Manual

CORD BLOOD COLLECTION / ANALYSIS- AT BIRTH

Fetal Prognosis in Varix of the Intrafetal Umbilical Vein

Document Classification

Baltimore, MD * The Corporation Trust Inc 351 West Camden Street * Baltimore, MD KATHLEEN WARD, M.D South Hanover Street *

Rural Health Advisory Committee s Rural Obstetric Services Work Group

Guideline for the Use of Oxytocin December 2012

CHAPTER 11 FETAL HEALTH SURVEILLANCE IN LABOUR

Intrapartum Fetal Heart Rate Monitoring. A Standardized Approach to Interpretation and Management

Maj Alison Baum. R3, Nellis FMR

Certified Professional Midwives Caring for Mothers and Babies in Virginia

Staff using electronic fetal monitoring should be aware of its limitations and artefacts, such as doubling maternal heart rate being displayed.

POLICIES AND PROCEDURES

How To Test For Fetal Blood

Distortions in Fetal Growth Standards

Provider Notification Obstetrical Billing

Oregon Birth Outcomes, by Planned Birth Place and Attendant Pursuant to: HB 2380 (2011)


Perinatal features and umbilical cord blood gases in newborns complicated with nuchal cord

Registered Nurse Initiated Activities Decision Support Tool No. 8A: Obstetrical Emergencies Cord Prolapse

UMBILICAL CORD CLAMPING FOR TERM INFANTS 37 WEEKS

Renown Regional Medical Center Department Of Obstetrics and Gynecology. Policies and Procedures Certified Nurse Midwives ( CNM S)

Fetal Blood Sampling Guideline

What do we mean by birth asphyxia

Neonatal Nucleated Red Blood Cell Counts

LECTURE OBJECTIVES & OUTLINES

SAMPLE. UK Obstetric Surveillance System. Management of Pregnancy following Laparoscopic Adjustable Gastric Band Surgery.

Chapter 14. Board of Certified Direct-Entry Midwives.

Evaluation and Follow-up of Fetal Hydronephrosis

A look at continuing developments in the field, including history of fetal monitoring and causation issues

Small for gestational age (SGA) and intrauterine growth

Preconception Clinical Care for Women Medical Conditions

Red Flags that should not be ignored

Why is prematurity a concern?

4/15/2013. Maribeth Inturrisi RN MS CNS CDE Perinatal Diabetes Educator

Fetal umbilical cord oxygen values and birth to placental weight ratio in relation to size at birth

CLINICAL GUIDELINE FOR VAGINAL BIRTH AFTER CAESAREAN SECTION (VBAC)

School of Diagnostic Medical Sonography

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE

Policy Title/Number: Fetal Heart Rate Monitoring AS Area Specific Labor and Delivery

8/13/2014. Blood, Sweat (and Tears): Delayed Cord Clamping and Delivery Room Temperature. Delayed Cord Clamping

OXYTOCIN: THE NEW HIGH ALERT MEDICATION. A. Oxytocin Becomes a High Alert Drug

A single center experience with 1000 consecutive cases of multifetal pregnancy reduction

Progression of Doppler abnormalities in intrauterine growth restriction

Corporate Reimbursement Policy

ANMC Certified-Nurse Midwife Practice Guideline

Umbilical and fetal middle cerebral artery Doppler at weeks gestation in the prediction of adverse perinatal outcome

The total cesarean section rate in the United States. Effect of Peer Review and Trial of Labor on Lowering Cesarean Section Rates.

Re-Evaluation of Cord Blood Arterial and Venous Reference Ranges for ph, po 2, pco 2, According to Spontaneous or Cesarean Delivery

Why the INFANT Study

How To Write An International Fetal Surveillance Guideline

South Dakota Task Force to Study Abortion Pierre, South Dakota September 21, 2005

Clinical Significance of First Trimester Umbilical Cord Cysts

Reference values for umbilical cord diameters in placenta specimens

Patient & Family Guide Pre-Existing Diabetes and Pregnancy

Diagnosis Codes for Pregnancy and Complications of Pregnancy

Relations Between Umbilical Troponin T Levels And Fetal Distress.

Transcription:

ACOG PRACTICE BULLETIN CLINICAL MANAGEMENT GUIDELINES FOR OBSTETRICIAN GYNECOLOGISTS NUMBER 9, OCTOBER 1999 (Replaces Technical Bulletin Number 188, January 1994) This Practice Bulletin was developed by the ACOG Committee on Practice Bulletins Obstetrics with the assistance of Dwight J. Rouse, MD. The information is designed to aid practitioners in making decisions about appropriate obstetric and gynecologic care. These guidelines should not be construed as dictating an exclusive course of treatment or procedure. Variations in practice may be warranted based on the needs of the individual patient, resources, and limitations unique to the institution or type of practice. Reaffirmed 2012 Antepartum Fetal Surveillance The goal of antepartum fetal surveillance is to prevent fetal death. Antepartum fetal surveillance techniques based on assessment of fetal heart rate patterns have been in clinical use for almost three decades. More recently, real-time ultrasonography and Doppler velocimetry have been used to evaluate fetal well-being. Antepartum fetal surveillance techniques are now routinely used to assess the risk of fetal death in pregnancies complicated by preexisting maternal conditions (eg, type 1 diabetes mellitus) as well as those in which complications have developed (eg, intrauterine growth restriction). This document will review the current indications for and techniques of antepartum fetal surveillance and outline management guidelines for antepartum fetal surveillance, consistent with the best contemporary scientific evidence. Background Physiology of Fetal Heart Response and Fetal Behavioral State Alteration In both animals and humans, fetal heart rate pattern, level of activity, and degree of muscular tone are sensitive to hypoxemia and acidemia (1 4). Redistribution of fetal blood flow in response to hypoxemia may result in diminished renal perfusion and oligohydramnios (5). Surveillance techniques such as cardiotocography, real-time ultrasonography, and maternal perception of fetal movement can identify the fetus that is either suboptimally oxygenated or, with increasing degrees of placental dysfunction, acidemic. Identification of suspected fetal compromise provides the opportunity to intervene before progressive metabolic acidosis can lead to fetal death. However, acute, catastrophic changes in fetal status, such as those that can occur with abruptio placentae or an umbilical cord accident, are generally not predicted by tests of fetal well-being. Therefore, fetal deaths from such events are not as amenable to prevention.

In humans, the range of normal umbilical blood gas parameters has been established by cordocentesis performed in pregnancies in which the fetus ultimately proved to be healthy, and ranges vary by gestational age (6). Although the degree of hypoxemia and acidemia at which various indices of fetal well-being become abnormal is not known with precision, it can be estimated, based on data from published studies. In one investigation, the fetal biophysical profile (BPP) was performed immediately before cordocentesis. Fetuses with a nonreactive nonstress test (NST) were found to have a mean (± standard deviation) umbilical vein ph of 7.28 ± 0.11. Cessation of fetal movement appears to occur at lower ph levels; fetuses with abnormal movement were found to have an umbilical vein ph of 7.16 ± 0.08 (7). Thus, a reasonable correlation between certain measurable aspects of fetal heart rate and behavior and evidence of fetal metabolic compromise can be inferred. However, when abnormal antepartum fetal surveillance results are compared with evidence of hypoxia or acidemia, the degree of acid base disturbance may range from mild to severe. Furthermore, factors other than acid base and oxygenation status (eg, prematurity, fetal sleep wake cycle, maternal medication exposure, and fetal central nervous system abnormalities) can adversely affect biophysical parameters. Finally, neither the degree nor the duration of intrauterine hypoxemia and acidemia necessary to adversely affect short- and long-term neonatal outcome has been established with any precision. Antepartum Fetal Surveillance Techniques Several antepartum fetal surveillance techniques (tests) are in use. These include fetal movement assessment, NST, contraction stress test (CST), BPP, modified BPP, and umbilical artery Doppler velocimetry. Fetal Movement Assessment A diminution in the maternal perception of fetal movement often but not invariably precedes fetal death, in some cases by several days (8). This observation provides the rationale for fetal movement assessment by the mother ( kick counts ) as a means of antepartum fetal surveillance. Although several counting protocols have been employed, neither the optimal number of movements nor the ideal duration for counting movements has been defined. Thus, numerous protocols have been reported and appear to be acceptable. In one approach, the woman lies on her side and counts distinct fetal movements (9). Perception of 10 distinct movements in a period of up to 2 hours is considered reassuring. Once 10 movements have been perceived, the count may be discontinued. In another approach, women are instructed to count fetal movements for 1 hour three times per week (10). The count is considered reassuring if it equals or exceeds the woman s previously established baseline count. In the absence of a reassuring count, further fetal assessment is recommended. Contraction Stress Test The CST is based on the response of the fetal heart rate to uterine contractions. It relies on the premise that fetal oxygenation will be transiently worsened by uterine contractions. In the suboptimally oxygenated fetus, the resultant intermittent worsening in oxygenation will, in turn, lead to the fetal heart rate pattern of late decelerations. Uterine contractions also may provoke or accentuate a pattern of variable decelerations caused by fetal umbilical cord compression, which in some cases is associated with oligohydramnios. With the patient in the lateral recumbent position, the fetal heart rate and uterine contractions are simultaneously recorded with an external fetal monitor. If at least three spontaneous contractions of 40 seconds duration each or longer are present in a 10-minute period, no uterine stimulation is necessary. If fewer than three contractions of at least 40 seconds duration occur in 10 minutes, contractions are induced with either nipple stimulation or intravenous administration of dilute oxytocin. Nipple stimulation usually is successful in inducing an adequate contraction pattern and allows completion of testing in approximately half the time required when intravenous oxytocin is given (11). In one nipple stimulation technique, the woman is instructed to rub one nipple through her clothing for 2 minutes or until a contraction begins (11). If by that time the contraction frequency has not become adequate (as defined previously), stimulation is stopped and restarted again after 5 minutes. If nipple stimulation is unsuccessful, or if the use of oxytocin is preferred, an intravenous infusion of dilute oxytocin may be initiated at a rate of 0.5 mu/min and doubled every 20 minutes until an adequate contraction pattern is achieved (12). The CST is interpreted according to the presence or absence of late fetal heart rate decelerations (13), which are defined as decelerations that reach their nadir after the peak of the contraction and that usually persist beyond the end of the contraction. The results of the CST are categorized as follows: Negative: no late or significant variable decelerations 2 ACOG Practice Bulletin No. 9

Positive: late decelerations following 50% or more of contractions (even if the contraction frequency is fewer than three in 10 minutes) Equivocal suspicious: intermittent late decelerations or significant variable decelerations Equivocal hyperstimulatory: fetal heart rate decelerations that occur in the presence of contractions more frequent than every 2 minutes or lasting longer than 90 seconds Unsatisfactory: fewer than three contractions in 10 minutes or an uninterpretable tracing Relative contraindications to the CST generally include conditions associated with an increased risk of preterm labor and delivery, uterine rupture, or uterine bleeding. These include the following (12): Preterm labor or certain patients at high risk of preterm labor Preterm membrane rupture History of extensive uterine surgery or classical cesarean delivery Known placenta previa Nonstress Test The NST is based on the premise that the heart rate of the fetus that is not acidotic or neurologically depressed will temporarily accelerate with fetal movement. Heart rate reactivity is thought to be a good indicator of normal fetal autonomic function. Loss of reactivity is associated most commonly with a fetal sleep cycle but may result from any cause of central nervous system depression, including fetal acidosis. With the patient in the lateral tilt position, the fetal heart rate is monitored with an external transducer. Ideally, the patient should not have smoked recently, because this may adversely affect test results (14). The tracing is observed for fetal heart rate accelerations that peak (but do not necessarily remain) at least 15 beats per minute above the baseline and last 15 seconds from baseline to baseline. It may be necessary to continue the tracing for 40 minutes or longer to take into account the variations of the fetal sleep wake cycle. Acoustic stimulation of the nonacidotic fetus may elicit fetal heart rate accelerations that appear to be valid in the prediction of fetal well-being. Such stimulation offers the advantage of safely reducing overall testing time without compromising detection of the acidotic fetus (15 17). To perform acoustic stimulation, an artificial larynx (ideally one of the commercially available models especially designed for this purpose) is positioned on the maternal abdomen and a stimulus of 1 2 seconds is applied. This may be repeated up to three times for progressively longer durations of up to 3 seconds to elicit fetal heart rate accelerations. Nonstress test results are categorized as reactive or nonreactive. Various definitions of reactivity have been used. Using the most common definition, the NST is considered reactive (normal) if there are two or more fetal heart rate accelerations (as defined previously) within a 20-minute period, with or without fetal movement discernible by the woman (18). A nonreactive NST is one that lacks sufficient fetal heart rate accelerations over a 40-minute period. The NST of the noncompromised preterm fetus is frequently nonreactive: from 24 to 28 weeks of gestation, up to 50% of NSTs may not be reactive (19), and from 28 to 32 weeks of gestation, 15% of NSTs are not reactive (20, 21). Variable decelerations may be observed in up to 50% of NSTs (22). If nonrepetitive and brief (<30 seconds), they indicate neither fetal compromise nor the need for obstetric intervention (22). Repetitive variable decelerations (at least 3 in 20 minutes), even if mild, have been associated with an increased risk of cesarean delivery for a nonreassuring intrapartum fetal heart rate pattern (23, 24). Fetal heart rate decelerations during an NST that persist for 1 minute or longer are associated with a markedly increased risk of both cesarean delivery for a nonreassuring fetal heart rate pattern and fetal demise (25 27). Biophysical Profile The BPP consists of an NST combined with four observations made by real-time ultrasonography (28). Thus, the BPP comprises five components: 1. Nonstress test (which, if all four ultrasound components are normal, may be omitted without compromising the validity of the test results) (28) 2. Fetal breathing movements (one or more episodes of rhythmic fetal breathing movements of 30 seconds or more within 30 minutes) 3. Fetal movement (three or more discrete body or limb movements within 30 minutes) 4. Fetal tone (one or more episodes of extension of a fetal extremity with return to flexion, or opening or closing of a hand) 5. Determination of the amniotic fluid volume (a single vertical pocket of amniotic fluid exceeding 2 cm is considered evidence of adequate amniotic fluid) (29, 30) Each of the five components is assigned a score of either 2 (normal or present as defined previously) or 0 (abnormal, absent, or insufficient). A composite score of 8 ACOG Practice Bulletin No. 9 3

or 10 is normal, a score of 6 is considered equivocal, and a score of 4 or less is abnormal. Regardless of the composite score, in the presence of oligohydramnios (largest vertical pocket of amniotic fluid volume 2 cm), further evaluation is warranted (30). Modified Biophysical Profile In the late second- or third-trimester fetus, amniotic fluid reflects fetal urine production. Placental dysfunction may result in diminished fetal renal perfusion, leading to oligohydramnios (5). Amniotic fluid volume assessment can therefore be used to evaluate long-term uteroplacental function. This observation fostered the development of what has come to be termed the modified BPP as a primary mode of antepartum fetal surveillance. The modified BPP combines the NST (with the option of acoustic stimulation), as a short-term indicator of fetal acid base status, with the amniotic fluid index (AFI), which is the sum of measurements of the deepest cord-free amniotic fluid pocket in each of the abdominal quadrants, as an indicator of long-term placental function (15). An AFI greater than 5 cm generally is considered to represent an adequate volume of amniotic fluid (31). Thus, the modified BPP is considered normal if the NST is reactive and the AFI is more than 5, and abnormal if either the NST is nonreactive or the AFI is 5 or less. Umbilical Artery Doppler Velocimetry Doppler ultrasonography is a noninvasive technique used to assess the hemodynamic components of vascular impedance. Umbilical artery Doppler flow velocimetry has been adapted for use as a technique of fetal surveillance, based on the observation that flow velocity waveforms in the umbilical artery of normally growing fetuses differ from those of growth-restricted fetuses. Specifically, the umbilical flow velocity waveform of normally growing fetuses is characterized by highvelocity diastolic flow, whereas with intrauterine growth restriction, there is diminution of umbilical artery diastolic flow (32 34). In some cases of extreme intrauterine growth restriction, flow is absent or even reversed. The perinatal mortality rate in such pregnancies is quite high (35). Abnormal flow velocity waveforms have been correlated histopathologically with small-artery obliteration in placental tertiary villi (36) and functionally with fetal hypoxia and acidosis (37), as well as with perinatal morbidity and mortality (35). Commonly measured flow indices, based on the characteristics of peak systolic frequency shift (S), end-diastolic frequency shift (D), and mean peak frequency shift over the cardiac cycle (A), include the following: Systolic to diastolic ratio (S/D) Resistance index (S-D/S) Pulsatility index (S-D/A) Randomized studies (38 44) of the utility of umbilical artery Doppler velocimetry generally have defined abnormal flow as either absent end diastolic flow, or a flow index greater than two standard deviations above the mean for gestational age. To maximize interpretability, multiple waveforms should be assessed, and wall-filter settings should be set low enough (typically <150 Hz) to avoid masking diastolic flow. Clinical Considerations and Recommendations Is there compelling evidence that any form of antepartum fetal surveillance decreases the risk of fetal demise or otherwise improves perinatal outcome? There is a dearth of evidence from randomized controlled trials that antepartum fetal surveillance decreases the risk of fetal death (45). Moreover, in one comprehensive review, antepartum fetal surveillance was categorized as a form of care likely to be ineffective or harmful (46). In spite of its unproven value, antepartum fetal surveillance is widely integrated into clinical practice in the developed world. Therefore, a definitive evaluation of antepartum fetal surveillance (which would require the random allocation of gravidas to prenatal care that included some form of antepartum fetal surveillance versus prenatal care that did not include any form of antepartum fetal surveillance) is unlikely to be conducted in a setting that can be generalized to current U.S. obstetric practice. In the absence of a definitive, relevant randomized clinical trial, evidence for the value of antepartum fetal surveillance will remain circumstantial and rest principally on the observation that antepartum fetal surveillance has been consistently associated with rates of fetal death that are substantially lower than the rates of fetal death in both untested (and presumably lower-risk) contemporaneous pregnancies from the same institutions (15, 16, 47) and pregnancies with similar complicating factors that were managed before the advent of currently employed techniques of antepartum fetal surveillance (historic controls). However, these perceived benefits of antepartum fetal surveillance may be influenced by the low incidence of adverse fetal outcome in the general population. The lower the incidence of adverse outcomes, the more likely favorable outcomes will be achieved regardless of test performance. 4 ACOG Practice Bulletin No. 9

What are the indications for antepartum fetal surveillance? Because antepartum fetal surveillance results have not been definitively demonstrated to improve perinatal outcome, all indications for antepartum testing must be considered somewhat relative. In general, antepartum fetal surveillance has been employed in pregnancies in which the risk of antepartum fetal demise is increased. Accordingly, some of the conditions under which testing may be appropriate include the following: Maternal conditions Antiphospholipid syndrome Hyperthyroidism (poorly controlled) Hemoglobinopathies (hemoglobin SS, SC, or S-thalassemia) Cyanotic heart disease Systemic lupus erythematosus Chronic renal disease Type 1 diabetes mellitus Hypertensive disorders Pregnancy-related conditions Pregnancy-induced hypertension Decreased fetal movement Oligohydramnios Polyhydramnios Intrauterine growth restriction Postterm pregnancy Isoimmunization (moderate to severe) Previous fetal demise (unexplained or recurrent risk) Multiple gestation (with significant growth discrepancy) When during gestation should antepartum fetal surveillance be initiated? Choosing the appropriate point in gestation to begin antepartum testing depends on balancing several considerations, including the prognosis for neonatal survival, the severity of maternal disease, the risk of fetal death, and the potential for iatrogenic prematurity complications resulting from false-positive test results. The importance of the last consideration is illustrated by the experience of one large center, in which 60% of infants delivered because of an abnormal antepartum test result had no evidence of short-term or long-term fetal compromise (16). Both theoretic models (48) and large clinical studies (49, 50) confirm that initiating testing at 32 34 weeks of gestation is appropriate for most at-risk patients. However, in pregnancies with multiple or particularly worrisome high-risk conditions (eg, chronic hypertension with suspected intrauterine growth restriction), testing might begin as early as 26 28 weeks of gestation. What is the proper frequency of testing? How frequently to perform fetal testing depends on several factors, including clinical judgment. If the indication for testing is not persistent (eg, a single episode of decreased fetal movement followed by reassuring testing in an otherwise uncomplicated pregnancy), it need not be repeated. When the clinical condition that prompted testing persists, the test should be repeated periodically until delivery to monitor for continued fetal well-being. If the maternal medical condition is stable and CST results are negative, the CST is typically repeated in 1 week (12). Other tests of fetal well-being (NST, BPP, or modified BPP) are typically repeated at weekly intervals (16), but in the presence of certain high-risk conditions, such as postterm pregnancy, type 1 diabetes, intrauterine growth restriction, or pregnancy-induced hypertension, some investigators have performed twice-weekly NST, BPP, or modified BPP testing. Any significant deterioration in the maternal medical status requires fetal reevaluation, as does any acute diminution in fetal activity, regardless of the amount of time that has elapsed since the last test. How reassuring is a normal test result? In most cases, a normal test result is highly reassuring, as reflected in the false-negative rate of antepartum fetal surveillance, defined as the incidence of stillbirth occurring within 1 week of a normal test result. The stillbirth rate, corrected for lethal congenital anomalies and unpredictable causes of demise, was 1.9 per 1,000 in the largest series of NSTs (5,861) versus 0.3 per 1,000 in 12,656 CSTs (13), 0.8 per 1,000 in 44,828 BPPs (51), and 0.8 per 1,000 in 54,617 modified BPPs (16). Based on these data, the negative predictive value of the NST is 99.8%, and greater than 99.9% for the CST, BPP, and modified BPP. Although similar data from a large series are not available for umbilical artery Doppler velocimetry, in one randomized clinical trial among women with pregnancies complicated by intrauterine growth restriction (38), no stillbirths occurred in 214 pregnancies in which umbilical artery Doppler velocimetry was the primary means of antepartum fetal surveillance (negative predictive value of 100%). The low false-negative rate of these tests depends on an appropriate response to any significant deterioration in the maternal clinical status, including retesting of the fetal condition. As mentioned previously, these tests generally do not predict stillbirths related to acute changes in maternal fetal status, such as those that occur with abruptio placentae or an umbilical cord accident. Moreover, recent, normal antepartum fetal test ACOG Practice Bulletin No. 9 5

results should not preclude the use of intrapartum fetal monitoring. How should one respond to an abnormal test result? An abnormal fetal test result should always be considered in the context of the overall clinical picture, taking into account the substantial possibility that the test result is falsely positive. Certain acute maternal conditions (eg, diabetic ketoacidosis, pneumonia with hypoxemia) can result in abnormal test results, which generally will become normal as the maternal condition improves. In these circumstances, stabilizing the maternal condition and retesting the fetus may be appropriate. In cases where an abnormal test result is not associated with any clinical evidence of worsening in the maternal status, a sequenced approach to the investigation of the fetal condition should be undertaken. Such an approach takes advantage of the high negative predictive value generally exhibited by all commonly used antepartum tests (see above), and minimizes the potential for unnecessary delivery based on a false-positive (ie, abnormal) test result. False-positive rates, in contrast to falsenegative rates, have typically not been calculated using the outcome of stillbirth. This is because most antepartum tests were introduced into clinical practice before an unbiased evaluation of their sensitivity and specificity. In clinical practice, abnormal test results usually are followed by another test or delivery is effected, which obscures the relationship between a positive test result and the subsequent risk of stillbirth. Therefore, in the absence of unbiased evaluations, the positive predictive value of antepartum tests has been estimated using surrogate markers, such as the rate of positive follow-up test results when the primary test result is positive. For example, it has been observed that up to 90% of nonreactive NSTs are followed by a negative CST result (18). Based on this observation, the positive predictive value of an NST is only 10%. Another way that the false-positive rate of fetal testing has been estimated is to calculate the incidence of abnormal test results that prompt delivery but are not associated with evidence of fetal compromise, as manifested by a nonreassuring intrapartum fetal heart rate, meconium-stained amniotic fluid, 5-minute Apgar scores of less than 7, or birth weight greater than the 10th percentile for gestational age. By this latter definition, in one large series, a testing scheme in which abnormal modified BPPs were followed by full BPPs had a false-positive rate of 60% (positive predictive value = 40%) (18). In another study in which the physicians were blinded to test results, a CST was found to have a positive predictive value of less than 35% (52). Therefore, the response to an abnormal test result should be tailored to the clinical situation. Maternal reports of decreased fetal movement should be evaluated by an NST, CST, BPP, or modified BPP; these results, if normal, usually are sufficient to exclude imminent fetal jeopardy. A nonreactive NST or an abnormal modified BPP generally should be followed by additional testing (either a CST or a full BPP). A positive CST result suggests that NST nonreactivity is a consequence of hypoxia-induced acidosis, whereas a negative result implies that the NST nonreactivity exists for another reason, such as a premature fetus, maternal exposure to certain drugs or medications, a fetal sleep cycle, or preexisting neurologic damage. In many circumstances, a positive CST result generally indicates that delivery is warranted. However, the combination of a nonreactive NST and a positive CST result is associated frequently with serious fetal malformation and justifies ultrasonographic investigation for anomalies whenever possible (53). Indeed, evaluation for grossly abnormal fetal anatomy should precede any intervention for suspected fetal compromise whenever possible. A BPP score of 6 is considered equivocal; in the term fetus, this score generally should prompt delivery, whereas in the preterm fetus, it should result in a repeat BPP in 24 hours (30). In the interim, maternal corticosteroid administration should be considered for pregnancies of less than 34 weeks of gestation. Repeat equivocal scores should result either in delivery or continued intensive surveillance. A BPP score of 4 usually indicates that delivery is warranted, although in extremely premature pregnancies, management should be individualized. Biophysical profiles less than 4 should result in expeditious delivery. Regardless of the overall score, oligohydramnios always requires further evaluation. In the absence of obstetric contraindications, delivery of the fetus with an abnormal test result often may be attempted by induction of labor, with continuous monitoring of both the fetal heart rate and contractions. Are there clinical circumstances in which one test is distinguished by its utility or lack thereof? A large-scale, definitive randomized trial comparing the relative efficacy of one technique of antepartum fetal testing to another has not yet been performed. Accordingly, in most clinical situations, no single antepartum fetal test can be considered superior to any other. As mentioned previously, in certain clinical situations, the CST is considered relatively contraindicated (increased risk of preterm labor and delivery, uterine rupture, and uterine bleeding), although even in these situa- 6 ACOG Practice Bulletin No. 9

tions the value of the information provided by the test may outweigh its potential risks. When should oligohydramnios prompt delivery? Amniotic fluid volume is estimated using ultrasonography. One widely used definition of oligohydramnios is no measurable vertical pocket of amniotic fluid greater than 2 cm (29), and another is an AFI of 5 cm or less (31). Nevertheless, from a clinical standpoint, an ideal cutoff level for intervention using the AFI has yet to be established. Determining when to intervene for oligohydramnios depends on several factors, including gestational age, the maternal and fetal clinical condition as determined by other indices of fetal well-being, and the actual measured AFI value. Because rupture of the fetal membranes can cause diminished amniotic fluid volume, an evaluation for membrane rupture may be appropriate. In postterm pregnancy, oligohydramnios is common and is associated with an increased risk of meconium staining of the amniotic fluid and cesarean delivery for nonreassuring fetal heart rate (54, 55). Thus, oligohydramnios has been considered an indication for delivery of the postterm pregnancy (15), although the effectiveness of this approach in improving perinatal outcome has not been established by randomized investigation. In a term pregnancy complicated by oligohydramnios, delivery often is the most appropriate course of action. However, management should be individualized, and in certain situations, delivery may be safely postponed (eg, an uncomplicated pregnancy with an AFI of 5 cm but otherwise reassuring fetal testing and an unfavorable cervix at 37 weeks of gestation). In the preterm fetus, depending on the maternal and fetal condition, expectant management may be the most appropriate course of action (eg, with preterm premature rupture of membranes or in the presence of fetal anomalies). Once oligohydramnios is diagnosed, if delivery is not undertaken, follow-up amniotic fluid volume and fetal growth assessments are indicated. If the oligohydramnios is persistent, close monitoring of the maternal condition and ongoing antepartum fetal surveillance should be performed to guide further management. If the oligohydramnios results from fetal membrane rupture, follow-up amniotic fluid volume assessment often may be safely omitted. What is the role of Doppler velocimetry? At least three randomized trials (38, 56, 57) have evaluated the utility of umbilical artery Doppler velocimetry as a technique of antepartum fetal surveillance in pregnancies complicated by suspected intrauterine growth restriction. In the first and largest of these trials (38), 214 pregnancies were allocated to Doppler umbilical artery velocimetry as the primary technique of fetal surveillance, and 212 were allocated to cardiotocography (NST). Overall, women in the Doppler group were significantly less likely to undergo obstetric intervention, including antepartum hospital admission, labor induction, and emergency cesarean delivery for nonreassuring fetal status. On average, women in the Doppler group underwent antenatal testing less frequently (4 times) than women in the cardiotocography group (8 times). Other perinatal outcomes, such as gestational age at birth, birthweight, Apgar scores, and cesarean birth rates, did not differ between the groups. Subsequent trials (56, 57) have supported the findings of less frequent antenatal monitoring (56) and shorter durations of maternal hospitalization (56, 57) in the Doppler group. However, rates of obstetric interventions, such as antepartum admission and labor induction, were not lower in the Doppler groups, and perinatal outcome was not improved. On balance, the available evidence suggests that primary antepartum surveillance of suspected intrauterine growth restriction with umbilical artery Doppler velocimetry can achieve at least equivalent (and possibly better) fetal and neonatal outcomes as primary antepartum surveillance based on results of the NST. Furthermore, frequency of antepartum testing and certain aspects of obstetric intervention are reduced with use of Doppler (58). If umbilical artery Doppler velocimetry is used, decisions regarding timing of delivery should be made using a combination of information from the Doppler ultrasonography and other tests of fetal wellbeing, such as amniotic fluid volume assessment, NST, CST, and BPP, along with careful monitoring of maternal status. No benefit has been demonstrated for umbilical artery velocimetry for conditions other than suspected intrauterine growth restriction, such as postterm gestation, diabetes mellitus, systemic lupus erythematosus, or antiphospholipid syndrome. Doppler ultrasonography has not been shown to be of value as a screening test for detecting fetal compromise in the general obstetric population, and its use for this purpose cannot be recommended (59). In addition to the umbilical artery, it is possible to evaluate blood flow in major fetal vessels. Multiple investigators have observed a correlation between increased flow resistance (elevated S/D ratio) in the umbilical artery and decreased resistance to flow (reduced S/D ratio) in the middle cerebral artery. This phenomenon has been attributed to a brain sparing adaptive response to fetal hypoxemia, and it has been suggested that the ratio of middle cerebral artery S/D ratio to umbilical artery S/D ratio might serve as a useful predictor of fetal compromise (60). However, the only randomized clinical trial of ACOG Practice Bulletin No. 9 7

middle cerebral artery Doppler velocimetry failed to demonstrate any clinical benefit to assessing this parameter (61). Moreover, women in this trial who were allocated to standard fetal evaluation plus assessment of the ratio of middle cerebral artery or umbilical artery Doppler flow, or both, were delivered on average 5.7 days earlier after the institution of fetal testing than women who were allocated to standard fetal evaluation without assessment of middle cerebral artery blood flow. This suggests that incorporation of middle cerebral artery Doppler flow assessment into clinical practice might increase unnecessary intervention. Therefore, at present, middle cerebral artery Doppler flow measurement should be considered investigational. Should all women perform daily fetal movement assessment? Whether programs of fetal movement assessment actually can reduce the risk of stillbirth is not clear. Only two randomized trials have addressed this issue. The first was conducted in a mixed high-risk (39%) and low-risk (61%) population of 3,111 Danish women who, after 32 weeks of gestation, were randomly assigned to an experimental (counting) group or a control group (10). Women in the experimental group were asked to count fetal movements for 1 hour three times a week and to contact their hospital immediately if they detected fewer movements than their previously established baseline. The control group of women were given no special fetal movement assessment instructions but were asked about fetal movement at their prenatal visits. Of the 1,583 women in the counting group, three experienced stillbirths of normally formed infants weighing more than 1,500 g, versus 12 stillbirths among the 1,569 women in the control group (P<0.05). Of women allocated to the counting group, 80% complied well with the protocol for counting, and 4% were evaluated for decreased fetal movement. The rates of operative vaginal birth and cesarean delivery did not differ significantly between the groups. The second randomized study to evaluate fetal movement allocated 68,000 women at 28 32 weeks of gestation to a counting policy (in which normal fetal movement was defined as the perception of 10 movements within 10 hours) or to routine care in which no special counting policies were employed (62). Women in the counting group with fewer than 10 movements in 10 hours for two successive days were instructed to alert their care provider, at whose discretion further evaluation was undertaken. Overall fetal death rates were low in this trial and did not differ significantly between the two groups (2.9/1,000 in the counting group versus 2.7/1,000 in the control group). More women in the counting group (7% versus 5%) underwent fetal heart rate testing, and more (5% versus 4%) were admitted antenatally to the hospital. However, the rates of labor induction and elective cesarean delivery did not differ significantly between the two groups. It should be noted that in the counting group, only 46% of women with decreased fetal movement alerted their care providers. Compliance for both recording fetal movements and reporting when they were diminished was even lower for women who experienced a stillbirth. Consistent evidence that a formal program of fetal movement assessment will result in a reduction in fetal deaths is lacking. Moreover, whether fetal movement assessment adds benefit to an established program of regular fetal surveillance has not been evaluated. One of the two randomized studies of fetal movement assessment suggests that its use may reduce stillbirths; the other does not. Formal movement assessment may increase, by a small degree, the number of antepartum visits and fetal evaluations. In the randomized trials, however, this increased surveillance did not result in a higher rate of intervention (10, 62). Summary The following recommendations are based on limited or inconsistent scientific evidence (Level B): Women with high-risk factors for stillbirth should undergo antepartum fetal surveillance using the NST, CST, BPP, or modified BPP. Initiating testing at 32 34 weeks of gestation is appropriate for most pregnancies at increased risk of stillbirth, although in pregnancies with multiple or particularly worrisome high-risk conditions, testing may be initiated as early as 26 28 weeks of gestation. When the clinical condition that has prompted testing persists, a reassuring test should be repeated periodically (either weekly or, depending on the test used and the presence of certain high-risk conditions, twice weekly) until delivery. Any significant deterioration in the maternal medical status or any acute diminution in fetal activity requires fetal reevaluation, regardless of the amount of time that has elapsed since the last test. An abnormal NST or modified BPP usually should be further evaluated by either a CST or a full BPP. Subsequent management should then be predicated on the results of the CST or BPP, the gestational age, the degree of oligohydramnios (if assessed), and the maternal condition. 8 ACOG Practice Bulletin No. 9

Oligohydramnios, defined as either no ultrasonographically measurable vertical pocket of amniotic fluid greater than 2 cm or an AFI of 5 cm or less, requires (depending on the degree of oligohydramnios, the gestational age, and the maternal clinical condition) either delivery or close maternal or fetal surveillance. In the absence of obstetric contraindications, delivery of the fetus with an abnormal test result often may be attempted by induction of labor with continuous monitoring of the fetal heart rate and contractions. If repetitive late decelerations are observed, cesarean delivery generally is indicated. Recent, normal antepartum fetal test results should not preclude the use of intrapartum fetal monitoring. Umbilical artery Doppler velocimetry has been found to be of benefit only in pregnancies complicated by intrauterine growth restriction. If used in this setting, decisions regarding timing of delivery should be made using a combination of information from the Doppler ultrasonography and other tests of fetal well-being, along with careful monitoring of maternal status. Middle cerebral artery Doppler velocimetry should be considered an investigational approach to antepartum fetal surveillance. References 1. Boddy K, Dawes GS, Fisher R, Pinter S, Robinson JS. Foetal respiratory movements, electrocortical and cardiovascular responses to hypoxaemia and hypercapnia in sheep. J Physiol 1974;243:599 618 (Level III) 2. Manning FA, Platt LD. Maternal hypoxemia and fetal breathing movements. Obstet Gynecol 1979;53:758 760 (Level III) 3. Murata Y, Martin CB Jr, Ikenoue T, Hashimoto T, Taira S, Sagawa T, et al. Fetal heart rate accelerations and late decelerations during the course of intrauterine death in chronically catheterized rhesus monkeys. Am J Obstet Gynecol 1982;144:218 223 (Level III) 4. Natale R, Clewlow F, Dawes GS. Measurement of fetal forelimb movements in the lamb in utero. Am J Obstet Gynecol 1981;140:545 551 (Level III) 5. Seeds AE. Current concepts of amniotic fluid dynamics. Am J Obstet Gynecol 1980;138:575 586 (Level III) 6. Weiner CP, Sipes SL, Wenstrom K. The effect of fetal age upon normal fetal laboratory values and venous pressure. Obstet Gynecol 1992;79:713 718 (Level III) 7. Manning FA, Snijders R, Harman CR, Nicolaides K, Menticoglou S, Morrison I. Fetal biophysical profile score. VI. Correlation with antepartum umbilical venous fetal ph. Am J Obstet Gynecol 1993;169:755 763 (Level II-2) 8. Pearson JF, Weaver JB. Fetal activity and fetal wellbeing: an evaluation. BMJ 1976;1(6021):1305 1307 (Level III) 9. Moore TR, Piacquadio K. A prospective evaluation of fetal movement screening to reduce the incidence of antepartum fetal death. Am J Obstet Gynecol 1989;160: 1075 1080 (Level II-2) 10. Neldam S. Fetal movements as an indicator of fetal wellbeing. Dan Med Bull 1983;30:274 278 (Level II-1) 11. Huddleston JF, Sutliff G, Robinson D. Contraction stress test by intermittent nipple stimulation. Obstet Gynecol 1984;63:669 673 (Level II-3) 12. Freeman RK. The use of the oxytocin challenge test for antepartum clinical evaluation of uteroplacental respiratory function. Am J Obstet Gynecol 1975;121:481 489 (Level III) 13. Freeman RK, Anderson G, Dorchester W. A prospective multi-institutional study of antepartum fetal heart rate monitoring. I. Risk of perinatal mortality and morbidity according to antepartum fetal heart rate test results. Am J Obstet Gynecol 1982;143:771 777 (Level II-3) 14. Graca LM, Cardoso CG, Clode N, Calhaz-Jorge C. Acute effects of maternal cigarette smoking on fetal heart rate and fetal body movements felt by the mother. J Perinat Med 1991;19:385 390 (Level III) 15. Clark SL, Sabey P, Jolley K. Nonstress testing with acoustic stimulation and amniotic fluid volume assessment: 5973 tests without unexpected fetal death. Am J Obstet Gynecol 1989;160:694 697 (Level II-3) 16. Miller DA, Rabello YA, Paul RH. The modified biophysical profile: antepartum testing in the 1990s. Am J Obstet Gynecol 1996;174:812 817 (Level II-3) 17. Smith CV, Phelan JP, Platt LD, Broussard P, Paul RH. Fetal acoustic stimulation testing. II. A randomized clinical comparison with the nonstress test. Am J Obstet Gynecol 1986;155:131 134 (Level I) 18. Evertson LR, Gauthier RJ, Schifrin BS, Paul RH. Antepartum fetal heart rate testing. I. Evolution of the nonstress test. Am J Obstet Gynecol 1979;133:29 33 (Level II-3) 19. Bishop EH. Fetal acceleration test. Am J Obstet Gynecol 1981;141:905 909 (Level II-2) 20. Lavin JP Jr, Miodovnik M, Barden TP. Relationship of nonstress test reactivity and gestational age. Obstet Gynecol 1984;63:338 344 (Level II-3) 21. Druzin ML, Fox A, Kogut E, Carlson C. The relationship of the nonstress test to gestational age. Am J Obstet Gynecol 1985;153:386 389 (Level III) 22. Meis PJ, Ureda JR, Swain M, Kelly RT, Penry M, Sharp P. Variable decelerations during nonstress tests are not a sign of fetal compromise. Am J Obstet Gynecol 1986;154: 586 590 (Level II-3) 23. Anyaegbunam A, Brustman L, Divon M, Langer O. The significance of antepartum variable decelerations. Am J Obstet Gynecol 1986;155:707 710 (Level II-2) 24. O Leary JA, Andrinopoulos GC, Giordano PC. Variable decelerations and the nonstress test: an indication of cord compromise. Am J Obstet Gynecol 1980;137:704 706 (Level III) ACOG Practice Bulletin No. 9 9

25. Bourgeois FJ, Thiagarajah S, Harbert GM Jr. The significance of fetal heart rate decelerations during nonstress testing. Am J Obstet Gynecol 1984;150:213 216 (Level III) 26. Druzin ML, Gratacos J, Keegan KA, Paul RH. Antepartum fetal heart rate testing. VII. The significance of fetal bradycardia. Am J Obstet Gynecol 1981;139:194 198 (Level III) 27. Pazos R, Vuolo K, Aladjem S, Lueck J, Anderson C. Association of spontaneous fetal heart rate decelerations during antepartum nonstress testing and intrauterine growth retardation. Am J Obstet Gynecol 1982;144: 574 577 (Level II-2) 28. Manning FA, Morrison I, Lange IR, Harman CR, Chamberlain PF. Fetal biophysical profile scoring: selective use of the nonstress test. Am J Obstet Gynecol 1987;156:709 712 (Level II-3) 29. Chamberlain PF, Manning FA, Morrison I, Harman CR, Lange IR. Ultrasound evaluation of amniotic fluid volume. I. The relationship of marginal and decreased amniotic fluid volumes to perinatal outcome. Am J Obstet Gynecol 1984;150:245 249 (Level II-3) 30. Manning FA, Harman CR, Morrison I, Menticoglou SM, Lange IR, Johnson JM. Fetal assessment based on fetal biophysical profile scoring. IV. An analysis of perinatal morbidity and mortality. Am J Obstet Gynecol 1990;162:703 709 (Level II-3) 31. Rutherford SE, Phelan JP, Smith CV, Jacobs N. The fourquadrant assessment of amniotic fluid volume: an adjunct to antepartum fetal heart rate testing. Obstet Gynecol 1987;70:353 356 (Level III) 32. Erskine RL, Ritchie JW. Umbilical artery blood flow characteristics in normal and growth-retarded fetuses. Br J Obstet Gynaecol 1985;92:605 610 (Level II-2) 33. Gudmundsson S, Marsal K. Umbilical and uteroplacental blood flow velocity waveforms in pregnancies with fetal growth retardation. Eur J Obstet Gynecol Reprod Biol 1988;27:187 196 (Level III) 34. Reuwer PJ, Bruinse HW, Stoutenbeek P, Haspels AA. Doppler assessment of the fetoplacental circulation in normal and growth-retarded fetuses. Eur J Obstet Gynecol Reprod Biol 1984;18:199 205 (Level II-2) 35. Karsdorp VH, van Vugt JM, van Geijn HP, Kostense PJ, Arduini D, Montenegra N, et al. Clinical significance of absent or reversed end diastolic velocity waveforms in umbilical artery. Lancet 1994;344:1664 1668 (Level II-2) 36. Giles WB, Trudinger BJ, Baird PJ. Fetal umbilical artery flow velocity waveforms and placental resistance: pathological correlation. Br J Obstet Gynaecol 1985;92:31 38 (Level II-2) 37. Nicolaides KH, Bilardo CM, Soothill PW, Campbell S. Absence of end diastolic frequencies in umbilical artery: a sign of fetal hypoxia and acidosis. BMJ 1988;297: 1026 1027 (Level III) 38. Almstrom H, Axelsson O, Cnattingius S, Ekman G, Maesel A, Ulmsten U, et al. Comparison of umbilicalartery velocimetry and cardiotocography for surveillance of small-for-gestational-age fetuses. Lancet 1992;340: 936 940 (Level I ) 39. Johnstone FD, Prescott R, Hoskins P, Greer IA, McGlew T, Compton M. The effect of introduction of umbilical Doppler recordings to obstetric practice. Br J Obstet Gynaecol 1993;100:733 741 (Level I) 40. Newnham JP, O Dea MR, Reid KP, Diepeveen DA. Doppler flow velocity waveform analysis in high risk pregnancies: a randomized controlled trial. Br J Obstet Gynaecol 1991;98:956 963 (Level I) 41. Omtzigt AM, Reuwer PJ, Bruinse HW. A randomized controlled trial on the clinical value of umbilical Doppler velocimetry in antenatal care. Am J Obstet Gynecol 1994; 170:625 634 (Level I) 42. Pattinson RC, Norman K, Odendaal HJ. The role of Doppler velocimetry in the management of high risk pregnancies. Br J Obstet Gynaecol 1994;101:114 120 (Level I) 43. Trudinger BJ, Cook CM, Giles WB, Connelly A, Thompson RS. Umbilical artery flow velocity waveforms in high-risk pregnancy. Randomised controlled trial. Lancet 1987;1(8526):188 190 (Level I) 44. Tyrrell SN, Lilford RJ, Macdonald HN, Nelson EJ, Porter J, Gupta JK. Randomized comparison of routine vs highly selective use of Doppler ultrasound and biophysical scoring to investigate high risk pregnancies. Br J Obstet Gynaecol 1990;97:909 916 (Level I) 45. Thacker SB, Berkelman RL. Assessing the diagnostic accuracy and efficacy of selected antepartum fetal surveillance techniques. Obstet Gynecol Surv 1986;41:121 141 (Level III) 46. Enkin M, Keirse MJNC, Renfrew M, Neilson J. A guide to effective care in pregnancy and childbirth. 2nd ed. Oxford: Oxford University Press, 1995:410 (Level III) 47. Nageotte MP, Towers CV, Asrat T, Freeman RK. Perinatal outcome with the modified biophysical profile. Am J Obstet Gynecol 1994;170:1672 1676 (Level I) 48. Rouse DJ, Owen J, Goldenberg RL, Cliver SP. Determinants of the optimal time in gestation to initiate antenatal fetal testing: a decision-analytic approach. Am J Obstet Gynecol 1995;173:1357 1363 (Decision Analysis) 49. Lagrew DC, Pircon RA, Towers CV, Dorchester W, Freeman RK. Antepartum fetal surveillance in patients with diabetes: when to start? Am J Obstet Gynecol 1993;168:1820 1826 (Level III) 50. Pircon RA, Lagrew DC, Towers CV, Dorchester WL, Gocke SE, Freeman RK. Antepartum testing in the hypertensive patient: when to begin. Am J Obstet Gynecol 1991;164:1563 1570 (Level III) 51. Manning FA, Morrison I, Harman CR, Lange IR, Menticoglou S. Fetal assessment based on fetal biophysical profile scoring: experience in 19,221 referred high-risk pregnancies. II. An analysis of false-negative fetal deaths. Am J Obstet Gynecol 1987;157:880 884 (Level II-3) 52. Staisch KJ, Westlake JR, Bashore RA. Blind oxytocin challenge test and perinatal outcome. Am J Obstet Gynecol 1980;138:399 403 (Level II-2) 53. Garite TJ, Linzey EM, Freeman RK, Dorchester W. Fetal heart rate patterns and fetal distress in fetuses with congenital anomalies. Obstet Gynecol 1979;53:716 720 (Level II-2) 10 ACOG Practice Bulletin No. 9

54. Leveno KJ, Quirk JG Jr, Cunningham FG, Nelson SD, Santos-Ramos R, Toofanian A, et al. Prolonged pregnancy. I. Observations concerning the causes of fetal distress. Am J Obstet Gynecol 1984;150:465 473 (Level III) 55. Phelan JP, Platt LD, Yeh SY, Broussard P, Paul RH. The role of ultrasound assessment of amniotic fluid volume in the management of the postdate pregnancy. Am J Obstet Gynecol 1985;151:304 308 (Level II-2) 56. Haley J, Tuffnell DJ, Johnson N. Randomised controlled trial of cardiotocography versus umbilical artery Doppler in the management of small for gestational age fetuses. Br J Obstet Gynaecol 1997;104:431 435 (Level I) 57. Nienhuis SJ, Vles JS, Gerver WJ, Hoogland HJ. Doppler ultrasonography in suspected intrauterine growth retardation: a randomized clinical trial. Ultrasound Obstet Gynecol 1997;9:6 13 (Level I) 58. Neilson JP, Alfirevic Z. Doppler ultrasound for fetal assessment in high risk pregnancies (Cochrane Review). In: The Cochrane Library, Issue 3, 1999. Oxford: Update Software (Meta-analysis) 59. Mason GC, Lilford RJ, Porter J, Nelson E, Tyrell S. Randomised comparison of routine versus highly selective use of Doppler ultrasound in low risk pregnancies. Br J Obstet Gynaecol 1993;100:130 133 (Level I) 60. Mari G, Deter RL. Middle cerebral artery flow velocity waveforms in normal and small-for-gestational-age fetuses. Am J Obstet Gynecol 1992;166:1262 1270 (Level II- 2) 61. Ott WJ, Mora G, Arias F, Sunderji S, Sheldon G. Comparison of the modified biophysical profile to a new biophysical profile incorporating the middle cerebral artery to umbilical artery velocity flow systolic/diastolic ratio. Am J Obstet Gynecol 1998;178:1346 1353 (Level I) 62. Grant A, Elbourne D, Valentin L, Alexander S. Routine formal fetal movement counting and risk of antepartum late death in normally formed singletons. Lancet 1989;2(8659):345 349 (Level I) ACOG Practice Bulletin No. 9 11

The MEDLINE database, the Cochrane Library, and ACOG s own internal resources and documents were used to conduct a literature search to locate relevant articles published between January 1985 and February 1999. The search was restricted to articles published in the English language. Priority was given to articles reporting results of original research, although review articles and commentaries also were consulted. Abstracts of research presented at symposia and scientific conferences were not considered adequate for inclusion in this document. Guidelines published by organizations or institutions such as the National Institutes of Health and the American College of Obstetricians and Gynecologists were reviewed, and additional studies were located by reviewing bibliographies of identified articles. When reliable research was not available, expert opinions from obstetrician gynecologists were used. Studies were reviewed and evaluated for quality according to the method outlined by the U.S. Preventive Services Task Force: I Evidence obtained from at least one properly designed randomized controlled trial. II-1 Evidence obtained from well-designed controlled trials without randomization. II-2 Evidence obtained from well-designed cohort or case control analytic studies, preferably from more than one center or research group. II-3 Evidence obtained from multiple time series with or without the intervention. Dramatic results in uncontrolled experiments also could be regarded as this type of evidence. III Opinions of respected authorities, based on clinical experience, descriptive studies, or reports of expert committees. Copyright October 1999 by the American College of Obstetricians and Gynecologists. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from the publisher. Requests for authorization to make photocopies should be directed to Copyright Clearance Center, 222 Rosewood Drive, Danvers, MA 01923, (978) 750-8400. ISSN 1099-3630 The American College of Obstetricians and Gynecologists 409 12th Street, SW PO Box 96920 Washington, DC 20090-6920 Based on the highest level of evidence found in the data, recommendations are provided and graded according to the following categories: Level A Recommendations are based on good and consistent scientific evidence. Level B Recommendations are based on limited or inconsistent scientific evidence. Level C Recommendations are based primarily on consensus and expert opinion. 12 ACOG Practice Bulletin No. 9