foundation ventilation systems for moisture and termite control



Similar documents
Foundation. Foundation

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.

Common Problems with Walls

HOW TO INSULATE A CRAWLSPACE

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

CLOSED CRAWLSPACES. Have you ever been in your crawlspace? If not, have you ever even

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

The Fallacies of Venting Crawl Spaces January 3, 2002 Craig DeWitt, PhD, PE

Installation Instructions

bout your house before you start Renovating Your Basement Moisture Problems

bout your HOUSE before you start Renovating Your Basement Moisture Problems

Preventing Ice Dams on Roofs

Dealing with damp and mould growth

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Facts About Home Cooling

FOXAIR 60/50 ALL MODELS

Basic Mold Prevention

Dehumidifier Users manual. For Models: DH45S DH65S

Smaller. Quieter. Smarter.

Critical for healthy indoor air quality.

HOME INSPECTION CHECKLIST

Vision Home Inspection

Product Data Bulletin

Controlling moisture. For your home. Bellevue, WA Puget Sound Energy. pse.com/myrebates. P.O. Box /14

Best Practices for Crawl Space Insulation

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

With colder weather approaching and heating costs continuing to skyrocket, ASHRAE is offering some simple ways to save energy and keep you and your

Ceiling Mount Air Handler Manual

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Mold and Mildew Mold and mildew can be detected by sight, smell and touch.

ATMOX is a moisture control system for crawl spaces and attics. ATMOX uses controls, sensors, and fans for proper ventilation.

CHAPTER 4 VENTILATION

about your house Before You Start Renovating Your Basement Moisture Problems Figure 1 Moisture problems to solve

Renovating Your Basement

Attic condensation during winter can

COMMONLY USED RESIDENTIAL BUILDING CODES

Residential Foundations and Basements

City of St. Charles Basement Finish or Remodel

PORTABLE AIR CONDITIONER

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Home Management Checklist: Preventing Home Moisture Damage. Exterior Checklist

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

SWIMMING POOL HEAT PUMP

Orlando Home Inspection Services

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Dehumidification Frequently Asked Questions

air conditioners how to choose a cooling system

Cuyahoga County Urban Mold & Moisture Project

MovinCool Office Pro Series. The Portable Spot Cooling Solution

Pre-Drywall Inspection Report

Your Guide to Buying an Energy-Efficient Central Air Conditioner

Energy Efficiency. Energy Efficient Home Cooling:

Single Family Residential Basement Finish

Termites: How to Reduce Your Home's Risk of Infestation

French Door Refrigerator E23BC78IPS professional series

October 5, 2015 Dear Client,

Heat Pumps for Swimming Pools

Glossary of HVAC Terms

CONDENSATION IN REFRIDGERATED BUILDINGS

What I will cover: Cuyahoga County Urban Mold & Moisture Project. Mold & moisture problems. Mold and moisture problems. Mold & moisture problems

WINDOW ROOM AIR CONDITIONER

Portable Air Conditioner

Chapter 2: Foundations

Water Management & Damage Prevention:

Product Catalog. Innovative Designs for the Construction Industry.

Joseph Laquatra Cornell University

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

CertainTeed. Protecting Your Home From Ice Dams Homeowner s Guide

STAINLESS STEEL WINE / BEVERAGE COOLER INSTRUCTION MANUAL HVBC31ST

3.6 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects

Mold Inspection Report (Initial Assessment)

THREE. Heating and Cooling

GenStore Archive Cabinet

20 GALLON WET DRY VACUUM

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

HVAC Code Requirements

DISPLAY & EXH I B I T

Installation Instructions For Slider Casement Air Conditioners

Home Inspection Report

ATMOX is a moisture control system for crawl spaces and attics and heat reduction system for attics.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Inspecting to a higher standard.

The Benefits Really Add Up

Facility Requirements for the elan2 Office Liquid Nitrogen Generator

Housing Services Guidance for tackling condensation, damp and mould in your home

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

This section gives you some helpful information and tips on running your home and the equipment in it.

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Transcription:

foundation ventilation systems for moisture and termite control

Help Protect Foundations with Temp-Vent The foundation is critical to the integrity of the home. That s why foundation ventilation is crucial. Unventilated foundations are subject to built-up moisture that can cause damp rot and eventually lead to costly damage. Temp-Vent foundation ventilation systems help protect this critical area of the home. What s more, ventilation can rid houses of other harmful conditions that could lead to problems including mold, mildew, fungi and unhealthy air. But there s more. If there s one thing termites are attracted to, it s warm, moist, dead air environments such as those found under houses in crawlspaces or unfinished basements. Termites need moisture as a food source. Temp-Vent foundation vents work to provide ventilation that can reduce moisture in these areas, which helps control termites, that can damage the structure. With Temp-Vent s complete line of easy-to-install foundation ventilation products, you can offer customers help in a total, long-term solution to termites and other moisture-damage problems as part of your total service package. Designed for the pest management professional, Temp-Vent foundation vents help control moisture buildup and termites in crawlspaces. TEMP-VENT

2 Specifying Temp-Vent Products When you recommend Temp-Vent foundation ventilation products to reduce moisture, you can install automatic, non-powered or electrical powered ventilators. Specifying a Temp-Vent foundation vent system is simple. All ventilators are sized to fit 8" x 16" standard block openings with 1" outside frame on each of four sides. However, the design of the system and the number of vents required are different for powered and non-powered vents. Automatic Foundation Vents The non-powered Automatic Foundation Vent will open and close automatically using a temperature sensitive coil. The louvers open completely at approximately 70 F and close completely at approximately 40 F. Unlike manual vents that can waste energy when no one remembers to open or close them, these vents self-adjust all year long to minimize moisture and help prevent damage from termites, mildew and other factors. To Specify: Whenever possible, vents should be placed on all sides of the foundation. This will create an intake/exhaust system that delivers a steady flow of air. Most building codes require one square foot of open ventilation area for every 150 square feet of crawlspace with one vent placed within three feet of each corner of the building. Temp-Vent Automatic Foundation Vents have 50 inches of net free area per vent. Therefore, you should install one vent for every 50 square feet of crawlspace to satisfy the 1/150 code requirement. For crawlspaces with a vapor retarder installed on 100% of the floor, the ventilation requirement changes to one square foot of ventilation for every 1500 square feet of crawlspace with a minimum of four vents installed to provide cross ventilation. Another way of looking at this, for crawlspaces with a vapor retarder, install at least one vent for every 500 feet of crawlspace to satisfy the 1/1500 code requirement. Powered Foundation Vents Powered Temp-Vent systems are designed for difficult moisture problems. These systems can move a larger amount of air per hour. Temp-Vent recommends powered vents be fitted with a Thermostat and a Humidistat to control the vent. To Specify: To determine the correct number of Powered Foundation Vents use the following formula: 1) Multiply the square feet of the crawlspace by the height in feet. This gives the number of cubic feet in the crawlspace. 2) Multiply the cubic feet in the crawlspace by the number of air changes per hour desired (4-6 is the recommendation). This gives the total number of cubic feet of air that has to be moved per hour to produce the desired number of air changes. 3) Divide this number by either 7,200 or 11,160 depending on which model is being used to obtain the number of powered vents needed. 4) Install vents to provide air intake on one side of the foundation with the powered vents on the other side to create a system of intake and exhaust. Example: 1500 square foot crawlspace x 3 feet high = 4500 4500 cubic feet x 6 = 27,000 / 7,200 = 3.74 Install four Quiet powered vents with intake vents on the opposite side. Customer Service: 1-800-525-3271 Fax: 1-800-635-7006 www.tempvent.com

3 Powered Foundation Vents Series 6 Series 5 and Series 6 s For homes with problems, Temp-Vent Powered Foundation Vents are the ideal choice. Powered vents are quick, convenient and economical when it comes to helping to solve moisture, mold and odor problems. Easy to install in standard 8" x 16" block openings, no mortar is required. Each unit is low voltage so no electrician is required in most situations. Air is suctioned out of the crawlspace and replaced with fresh outside air. Negative pressure helps prevent dampness and odor from rising into living areas of the home. Totally enclosed motors feature a custom plug and are 0.01 HP rated (Quiet ) or 0.017 HP rated (High Output ) for continuous operation. These motors are 24VAC. Series 6 is a one-piece vent and Series 5 vents have a removable front frame that can be snapped on after installation. Series 5 Power vents should be placed on one side of the house, with non-powered vents that act as intake vents on all remaining sides. The controls kit is required and sold separately. It can operate up to three power vents. The Temp-Vent Radon The Powered Temp-Vent Radon uses positive pressure ventilation to help remove potentially harmful radon from the crawlspace before it creeps into the home. It also reduces radon emission from the soil in the crawlspace. Radon Specifications Colors Series 6, High Output 3000 rpm TV6LVHPBL Black 1.0 amps, 24 volts 11,160 cubic ft./hr. Series 6, Quiet 1550 rpm TV6LVQPBL Black.9 amps, 24 volts 7,200 cubic ft./hr. Series 5, High Output 3000 rpm TV5LVHPBL Black removable front frame 1.0 amps, 24 volts 11,160 cubic ft./hr. Series 5, Quiet 1550 rpm TV5LVQPBL Black removable front frame.9 amps, 24 volts 7,200 cubic ft./hr. Radon Radon Quiet 1550 rpm PRQM Black (No Control Kit Required).5 amps, 115 volts 7,200 cubic ft./hr.

4 Powered Foundation Vent Accessories Controls Kit Controls Kit includes Damp Weather Shutoff, Humidistat, Power Supply Unit and Control Cables. The Controls Kit is required on Series 5 and Series 6 s and is sold separately. Damp Weather Shutoff Thermostat: The Thermostat is mounted near an intake vent opposite the side where the power vent is mounted and is set at approximately 40 o F, the Thermostat turns the unit off when the crawlspace temperature drops below the setting. Normally, when the temperature outside is at 40 o F the temperature in the crawlspace is approximately 50 o F. The Thermostat helps protect pipes and save energy by turning the vent off when the temperature is close to freezing. Damp Weather Humidistat: The Damp Weather Humidistat is in the same enclosure as the thermostat and mounted near an intake vent. Powered vents stay on when the humidity is below the setting. The vents shuts off when the outside humidity rises above the setting or if there is a quick rise in humidity, such as when it starts to rain. Thermostat/Humidistat w/built-in plug DWS Humidistat The Humidistat turns the unit on when the humidity in the crawlspace rises above a pre-set limit, usually at 50% humidity. Humidistat LVHU Power Supply Unit The Power Supply Unit is UL listed and features a three prong plug. It has 24VAC outputs to operate up to three Power Vents and two additional receptacles to accommodate the Damp Weather Shutoff and the Humidistat. Power Supply Unit LVPW Control Cables There are two 25 foot Control Cables which are used to attach the Damp Weather Shutoff and the Humidistat to the Power Supply Unit. DWS LVHU LVPW Control Cables LVCBL LVCBL Duct System The Powered Temp-Vent Duct System is ideal for homes with difficult-to-ventilate situations including: Porch areas Obstructed, divided or unusually shaped crawlspaces Interior walls in crawlspaces or weeping foundation walls Heating, air conditioning or water heater obstructions Special condensation areas The Duct Adapter attaches to a powered vent. Then the Flexible Duct is attached to the Adapter and positioned to provide targeted ventilation, pulling moist air through the Duct and exhausting it outside. Flexible Duct 25' section w/one roll of tape Duct Adapter DU AD-1 Flexible Duct and Adapter Customer Service: 1-800-525-3271 Fax: 1-800-635-7006 www.tempvent.com

5 Automatic Foundation Vents Automatic Foundation Vents take the worry out of remembering to open and close vents as the weather changes, so the home can be protected from decay. The vent has a bi-metal coil to open and close automatically without electricity. When the temperature reaches approximately 70 F, the vent is fully opened to provide fresh intake air, and fully closes at approximately 40 F to conserve energy and protect pipes. These vents are easily installed using screws, or screw anchors, or with retaining clips. Both are included with the vents. No mortar is required for installation. Temp-Vent Automatic Foundation Vents Features: A heavy-duty coil for dependable operation 8" x 16" to fit into a standard block opening Net free area of 50 square inches Removable back for easy cleaning and maintenance Optional 5" x 13" vent for smaller openings (fits between 16" OC floor joists) Series 6 The Series 6 vents are one piece, while the Series 5 vents have a removable front frame (in addition to the removable back) that can be snapped on after installation. Series 5 is also available with a 2-inch oversized frame. Colors Series 5 with oversized frame Temp-Vent Series 6 TV6 black, brown, gray Temp-Vent Series 5 - with removable front frame TV5 black, brown, gray Temp-Vent Series 5 - with oversized frame TV5-OSF black, brown, gray Solar Tek II - 5" x 13" vent ST2GR-J gray only Installation Tips: Non-Powered Foundation Vents For proper ventilation, one vent should be installed every 8-10 feet. Avoid dead air spaces by placing a vent within 3 feet of each corner. A minimum of four vents are required to provide cross- ventilation. Manual Replacement Vent Manual Foundation Vents must be manually opened in warmer months to provide ventilation and closed in cold weather to guard against pipe freeze. The Manual Replacement Vent is the same vent as the Temp-Vent Automatic Foundation Vent with no automatic coil; therefore it requires manual operation. Colors Manual Replacement Vent RM black, brown Trim shrubbery and remove obstructions from in front of the vent to allow air to flow freely.

6 Other Temp-Vent Products Vent Well The Vent Well from Temp-Vent provides air space for below grade foundation vents and helps keep water away from the crawlspace. With its sturdy, no-rust thermoplastic construction, it is an attractive alternative to unsightly, rusted and sharp-edge metal vent wells. The unit measures 21" wide by 14" high and 12" deep. D Colors Vent Well VW black, brown, gray Temp-Vent products are designed for the pest management professional. In fact, Temp-Vent is the only brand of foundation vents designed for and dedicated to serving the pest control industry. With our commitment and your knowledge of both termite and moisture control, customers will readily see the value of having a Temp-Vent foundation vent system installed. TEMP-VENT Customer Service: 1-800-525-3271 Fax: 1-800-635-7006 www.tempvent.com

4117 Pinnacle Point Drive, Suite 400 Dallas, TX 75211 Customer Service 1-800-525-3271 Fax 1-800-635-7006 www.tempvent.com TV202 9/13 2013 Temp-Vent Corporation