SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS



Similar documents
ELECTRIC INSTANTANEOUS WATER HEATER

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX

Overheating limit control

SF15K SF05KSS, SF10KSS

SERVICE MANUAL Order No.WH0911S001V0

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Portable Air Conditioner

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Oil and Coolant Circulating Heating System. Model - OCSM

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Shower Handbook (Also covers 650 chrome variant)

Electric Instantaneous. Water Heaters. Service manual

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Meaco 30L and Meaco 40L dehumidifier instruction manual

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Operators manual Basic water heater

Use and Care Manual. Model CPA12KH AIR CONDITIONER

INFRARED QUARTZ WALL HEATER

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

SunMaxx Solar Filling Station Operating Instructions

Liquorice Kitchen Sink Tap

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

USER S MANUAL HSC-24A

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Elson 10/15L Unvented Water Heater

Chill 4 Hole Bath Shower Mixer

Important Safeguards

Artisan Thermostatic Bath Shower Mixer

Design Utility Lever Thermostatic Bath Shower Mixer

ELECTRIC CENTRAL HEATING FLOW BOILER

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

INSTALLATION INSTRUCTIONS BL-8704

Almond Kitchen Sink Tap

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Installation and maintenance instructions. Danfoss Vent

Assembly and instructions

INSTALLATION INSTRUCTIONS MK-8704

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Apricot Kitchen Sink Tap

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

SWIMMING POOL HEAT PUMP

Isotemp Basic, Slim/B & Slim Square

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

Gas Instantaneous Water Heater

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Itho Products for Hot and Boiling water. product-

2-SLICE COOL TOUCH TOASTER

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

Aquatap (Boil and Chill / Boil and Ambient) Installation and user manual

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

INSTALLATION & TECHNICAL MANUAL

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

User's Instructions. Alpha HE CB25/33 and HE SY25

User Manual THR840DUK Digital Thermostat

Alpha CD13R,18R and 24R

CARING FOR YOUR WATER HEATER

TAMPERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

Please read operating instructions carefully before use and keep for further reference.

Installation, Operating and Servicing Instructions. Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Electric Water Heater

SWIMMING POOL HEAT PUMP Owners Manual

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Please also see 10 golden rules for correct Saniflo installation on

Geyser-R Heat pump water heater Installation manual

Aquamax Australia Pty Ltd ABN

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

3 IN 1 BATHROOM HEATER

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

For installation guide see reverse of book

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Thermostatic bar showers. Troubleshooting and maintenance

B150 Series Commercial Brewer. Direct Plumb Kit

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

ATS Overhead Table Shelf System INSTRUCTION MANUAL

SELECTION, APPLICATION AND MAINTENANCE

LUCCI AIRFUSION QUEST II CEILING FAN

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

Transcription:

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

2 This water heater must be installed (water and electrical installation), commissioned and serviced by approved service technicians in accordance with these instructions. Please read carefully Read these instruction carefully before using the appliance and retain them for future reference. If the appliance is passed on the third party please hand these instructions to the new user. - This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. - Children should be supervised to ensure that they do not play with the appliance.

1. Installation instructions for the qualitified installer 3 Functions Fixing method Shower head level must not be higher than the unit min. 4,5 mm max. 10 mm 10 A B D C 11 Fig 1 Fig 3 Mounting dimensions Electrical connection 9 8 The unit must be earthed! 360 mm 280 mm 360 mm. 7 100 mm 212 mm 105 mm The cable bushing must be used to provide protection against the penertration of water. Fig 2 Fig 4

4 1. Installation instructions for the qualitified installer Fixing, cleaning Wiring Diagram a d f 12 13 e b c Fig 5 Fig 6 14 15 g a - Heating Element b - Electronic control set (Phase Cut) c - ELSD Circuit d - Triac Set e - Auto Thermostat f - ELSD-Button Board g - ELSD Sensor Coil

5 1. Installation instructions for the qualitified installer 1.1 Description of the unit The AEG BS pressureless (open) small instantaneous water heater is a device for heating water for shower. The electricalpower is electronically controlled. The flow is controlled by using the water valve (C). The unit switches the power on once the flow volume reach 1.5-2 l/min. The Power light (A) indicates that the unit is switched on. If the temperature adjustment rotary (B) switch is turned to the left, it is possible to take a cold shower (the heating will not be switched on). The BS is fitted with an overheating protection device. In the event of overheating the heating power will be cut off. 1.2 The essentials-in brief (Fig. 1) A Power light B Rotary control for temperature adjustment C Water valve D Shower accessories Warning! If the Trip light activate after reset or if the light activate during shower, never try to fix it. Contact your dealer for a check and repair. 1.4 Care and Maintenance All that is needed for cleaning is a damp cloth. Do not use any abrasive cleaning agents or agents containing solvents. Maintenance work may only be carried out by a qualified installer. 1.5 Hot water capacity The hot water capacity depends on the power of the unit, the cold water temperature, and the flow volume 1.3 Important information The unit must not be put under pressure. The outlet of the unit is also used as a vent. A periodical scale removal is essential for the function of the shower head. The unit is optional equipped with an ELSD (Type BS...E only). It is recommended to test the ELSD one time per month. How to test: Switch on the electrical supply. Press the Test button, the Trip light will go on. Press the Reset button.

6 1. Installation instructions for the qualitified installer Technical Data Type 35 35 E 45 45 E Design Rate pressure Water connection BS Open outlet 0 MPa / 0 bar G ½ (Extenal Thread) Electrical connection 1/N/PE/AC 220...240 V. 60 60 E Recomended circuit breaker 20 A. 25 A. 32 A. Recomended cable size (Sqmm) 2.5-4 4-6 Rated power (kw) Rated current (A) kw - A kw - A kw - A 220 V 3.5-15.9 4.5-20.5 6.0-27.3 230 V 3.8-16.5 4.9-21.3 6.6-28.7 240 V 4.2-17.5 5.4-22.5 7.1-29.6

7 2. Operating instructions for the qualitified installer Unit structure 2 1 3 4 Fig 7 2.1 Technical description Fig. 7 1. Thermostat 2. Cable duct for electrical connection 3. Power light 4. Rotary control for temperature adjustment 5. Hot water connection for shower hose 6. Cold water connection Fig. 2 7. Lower fixing hole 8. Position for electrical connection, concealed 9. Upper fixing hole 5 16 6 Fig. 3 10. Depth for mounting screw 11. Rear wall installation Fig. 5 12. Combination filter/seal 13. Washer 14. Water valve 15. Union nut (provided by client) Fig. 7 16 ELSD (option)

8 2. Operating instructions for the user and the qualitified installer 2.2 Regulations and Provisions Regulations of the local power supply company must be observed. Regulations of the water supply company must be observed. Install the unit flush with the wall. Electrical connection to be secure. The device must be capable of being isolated from the mains, for example by fuses, with an isolating distance of at least 3.5 mm, in all poles. The unit must be earthed (see circuit diagram). 2.3 Important note All the information in these Operating and Installation Instructions must be carefully followed. These instructions provide important details regarding the safety, operation, installation, and maintenance of the unit. 2.4 Installation location The shower unit is to be installed in a frost-free room (disconnected units are to be stored in a frost-free location, since there will always be some water left in the unit) The BS is to be installed vertically on a wall (hot water connection downwards) and higher than shower head level. 2.5 Installing the unit 1. Flush the cold water pipe thoroughly. 2. Fit a secure connection cable (ensure size is correct). 3. Release cover securing screw. 4. Remove cover. 5. Determine the position of the drillholes and drill the holes. Insert the wall plugs and screw in the screws (ensure screw insertion depth is correct, 10). Fix the base to the wall. 6. Feed the connection cable through the duct (2) in the rear wall. Tighten the screws. 7. Fit the water valve (14) with the washer (13). Tighten the Union nut (15) 8. Connect the electrical supply. 9. Fit the cover and secure with the screw. 10. Turn the rotary control (B) to the left and right (internal setting lever will engage). 11. Fit the shower accessories to the unit. 2.6 First operation (Only to be carried out by a qualified installer) Before switching on, set the water valve to the right-hand stop (maximum setting) and let water run until the pipework and the unit are free of air. - Before switching on, set the rotary temperature control to OFF - Check the operation of the water heater

9 2. Operating instructions for the user and the qualitified installer Handing over the unit Explain to the user how the unit works and familiarise him or her with its use. - Advise the user about possible hazards (high water temperature) - Hand over these instructions, to be kept in a safe place. 2.7 Service note When carrying out any work, isolate the unit from the mains and shut off the water connection.

10 3. Guarantee For guarantees please refer to the respective terms and conditions of supply for your country. The installation, electrical connection and first operation of this appliance should be carried out by a qualified installer. The company does not accept liability for failure of any good supplied which have not been installed and operated in accordance with the manufacturer s instructions. 4. Trouble-shooting Fault Cause Solution No hot water despite flow volume setting at right-hand stop. The unit is not working. Electricity supply and flow available. ELSD Light on The water flow volume required for the unit to turn on has not been reached. - The shower head is blocked with dirt or limescale. - Flow volume too low The water flow volume required for the unit to turn on has not been reached. - Filter in the cold water connection pipe blocked with dirt. - Water pressure not enough - The safety device activated. - Clean shower head - Increase flow volume. - Clean the filter after shutting off the cold water intake - Increase mains pressure - Press Reset button

11

SIZE:A5 MATERIAL: GREEN READ PAPER 75 G. PLASTIC BAG : 7 x 11 INCH PART NO. 7901-269459 PART NAME : MANUAL BS Rev.04 Product code : BS 35 E : 221070 / BS 45 E : 221071 / BS 60 E : 221072