SmartClass Ethernet 10M-1G Ethernet Tester



Similar documents
FST-2802 TestPad Gigabit Ethernet Services Module Test Ethernet, Fibre Channel, and IP services using one test instrument!

FST-2802 TestPad Gigabit Ethernet Services Module Now able to test Ethernet, Fibre Channel, and IP services in a single test instrument!

MPX100 Intelligent Ethernet Test Probe

VePAL MX300. Platform Highlights. Key Features. 10GbE LAN/WAN and Gigabit Ethernet and Fast Ethernet Test Set. Metro Expert

Advanced Test Set for 10/100/Gigabit Ethernet

HST-3000 Ethernet Service Interface Module (SIM)

CMA5000 SPECIFICATIONS Gigabit Ethernet Module

Advanced Test Set for 10/100/Gigabit Ethernet

GigE Triple Play PIM. Comprehensive prioritization support including VLAN Q-in-Q, layer 3 IP ToS and Cisco DSCP

Verifying Metro Ethernet Quality of Service

APPLICATION NOTE 209 QUALITY OF SERVICE: KEY CONCEPTS AND TESTING NEEDS. Quality of Service Drivers. Why Test Quality of Service?

Carrier Ethernet: New Game Plan for Media Converters

CMA Ethernet interface measurement options SPECIFICATIONS

Central Office Testing of Network Services

Opternus GmbH. optische Spleiss- und Messtechnik. Tel. +49(0) Fax +49(0)

Network Master Gigabit Ethernet Tester. Network Master Gigabit Ethernet Tester. Introduction. By Ole Sørensen Product manager.

The MTS-8000 Transport Module SDH, PDH, and Ethernet Test Module for the MTS-8000

AXS-200/850 ETHERNET TEST SET. part of the SharpTESTER Access Line

Cisco SLM Port Gigabit Smart Switch Cisco Small Business Smart Switches

Ethernet Link SGI-2424

Ethernet Link SGI-4844F

Chapter 4 Connecting to the Internet through an ISP

JDSU HST-3000 RFC-2544 Ethernet Testing Guide

Gigabit Ethernet Turn-up Procedure using the JDSU T-BERD 8000 or T-BERD 6000A March 4, 2009

Cisco SLM Port Gigabit Smart Switch Cisco Small Business Smart Switches

Installation, Commissioning, and Maintenance of Metro Ethernet Networks Using T-BERD/MTS 8000 and NetComplete (QT-600) Metro Ethernet Service Solution

Service Definition. Internet Service. Introduction. Product Overview. Service Specification

JDSU Ethernet Testing

Testing VoIP on MPLS Networks

ParaScope 1GE-1. Handheld Ethernet/Fibre Channel Tester. Key Features

Acterna DSL Services Tester TPI 350+ Application Highlights

RFC 2544 Testing of Ethernet Services in Telecom Networks

RFC 6349 Testing with TrueSpeed from JDSU Experience Your Network as Your Customers Do

Troubleshooting LANs with Network Statistics Analysis

ParaScope 10GE-1. Handheld 10G Ethernet/Fibre Channel Tester. Key Features

Cisco Small Business Managed Switches

Ethernet Service OAM. Standards and Functionality. Connectivity Fault Management (CFM) Fault Detection. White Paper

Troubleshooting LANs with Wirespeed Packet Capture and Expert Analysis

T-BERD /MTS-4000 Multiple Services Test Platform Enterprise Services Application Module (ESAM)

SSVP SIP School VoIP Professional Certification

TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P.

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL

Cisco Small Business Smart Switches

Packet Capture and Expert Troubleshooting with the Viavi Solutions T-BERD /MTS-6000A

VePAL MX100+ Key Features. Platform Highlights. Handheld Ethernet Test Set

TP-LINK L2 Managed Switch

HST-3000 Ethernet Service Interface Module (SIM)

AXS-200/850 ETHERNET TEST SET. part of the SharpTESTER Access Line

Cisco SRW2024P 24-Port Gigabit Switch: WebView/PoE Cisco Small Business Managed Switches

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL5428E.

TP-LINK. 24-Port Gigabit Smart Switch with 4 SFP Slots. Overview. Datasheet T1600G-28TS (TL-SG2424)

Cisco Small Business Managed Switches

AXS-200/650 IP TRIPLE-PLAY TEST SET. part of the SharpTESTER Access Line. Telecom Test and Measurement

JDSU NetCompleteTM Metro Ethernet Service Assurance Solution Brochure

Cisco SLM248P 48-Port 10/ Port Gigabit Smart Switch: SFPs/PoE

axs-200/650 IP TRIPLE-PLAY TEST SET

Auditing the LAN with Network Discovery

SSVVP SIP School VVoIP Professional Certification

TP-LINK. JetStream 28-Port Gigabit Stackable L3 Managed Switch. Overview. Datasheet T3700G-28TQ.

TP-LINK. 48-Port Gigabit Smart Switch with 4 SFP Slots. Overview. Datasheet T1600G-52TS (TL-SG2452)

HES-3106-RF Series Managed CPE Switch

SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series

Networking 4 Voice and Video over IP (VVoIP)

TP-LINK. Gigabit L2 Managed Switch. Overview. Datasheet TL-SG3216 / TL-SG

EX 3500 ETHERNET SWITCH

DA-3600A Data Network Analyzer Advanced Network analysis and troubleshooting

Layer 3 Network + Dedicated Internet Connectivity

TP-LINK. 24-Port Gigabit L2 Managed Switch with 4 SFP Slots. Overview. Datasheet TL-SG

APPLICATION NOTE 183 RFC 2544: HOW IT HELPS QUALIFY A CARRIER ETHERNET NETWORK. Telecom Test and Measurement. What is RFC 2544?

JDSU Network Analyzer 10 Gigabit Ethernet Analysis Solution Wireline Protocol Test

Cisco SFE1000P 8-Port 10/100 Ethernet Switch: PoE/Fanless Cisco Small Business Managed Switches

Accelerating Development and Troubleshooting of Data Center Bridging (DCB) Protocols Using Xgig

IntraCore Series 16-port Gigabit Managed Switches Layer 2

XMVAE Gigabit Ethernet Modules

TP-LINK 24-Port Gigabit L2 Managed Switch with 4 SFP Slots

VLAN and QinQ Technology White Paper

Cisco Catalyst 3750 Metro Series Switches

John Ragan Director of Product Management. Billy Wise Communications Specialist

Network Simulation Traffic, Paths and Impairment

Please review the following common configurations to optimize performance.

T-BERD MTS 5800 Handheld Network Test Family

Software version Feb 21, 2014

ALLNET ALL8944WMP Layer 2 Management 24 Port Giga PoE Current Sharing Switch

Loop-IP6702 TDMoEthernet

NaviTEK II. idealnwd.co.uk. Save money through using a single multifunction device for testing copper and fibre networks

Burst Testing. New mobility standards and cloud-computing network. This application note will describe how TCP creates bursty

ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af

T-BERD MTS 8000 and T-BERD MTS 6000A Transport Module, 40/100G Transport Module, and Multiple Services Application Module

REMOTE MONITORING MATRIX

CN-100 Network Analyzer

APPLICATION NOTE 210 PROVIDER BACKBONE BRIDGE WITH TRAFFIC ENGINEERING: A CARRIER ETHERNET TECHNOLOGY OVERVIEW

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

EUSM - Ethernet Universal Service Module

High Performance 10Gigabit Ethernet Switch

VePAL MX120+ Key Features. Platform Highlights. Dual Port Handheld Ethernet Test Set

20 GE + 4 GE Combo SFP G Slots L3 Managed Stackable Switch

Detecting Bridged Tap and Noise Interference in VDSL2 Access Networks using the JDSU SmartClass TPS

APPLICATION NOTE 211 MPLS BASICS AND TESTING NEEDS. Label Switching vs. Traditional Routing

NaviTEK II. idealnwd.co.uk. Save money through using a single multifunction device for testing copper and fibre networks

TP-LINK. 24-Port Gigabit L2 Managed PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG3424P.

Transcription:

COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS SmartClass Ethernet 10M-1G Ethernet Tester Key Features Generates and measures L2/L3 traffic on up to 1G electrical or optical Ethernet interfaces with VLAN, Q-in-Q tags, or MPLS labels RFC2544 proves acceptance for Ethernet service level agreements MPLS Test checks for correct policing and prioritization in MPLS domains using the MPLS option Physical Layer tests verify integrity of the physical layer to pass traffic before testing throughput Ethernet Loopback completes the JDSU Ethernet field test portfolio Applications Optional Asymmetric RFC2544 mode enables verification of circuits with different up and downstream rates Verifies QoS for triple-play networks by simultaneously measuring throughput, latency, jitter, and errors on up to 8 specific VLAN or Q-in-Q tagged traffic flows with the Multiple Streams option Available in a loop-only version to save on CAPEX and allows for upgrades in the field to full functionality if needed Ethernet Services Testing The SmartClass Ethernet provides an economical 1 G Ethernet test set with optical and electrical interfaces that is an easy-to-use, entry-level Ethernet/ tester for front-line technicians who support Metro Ethernet networks. The compact, rugged, and battery-operated SmartClass is ideal for technicians turning up Ethernet and Internet Protocol () services in the field. Technicians can use the SmartClass Ethernet for physical layer cable testing, Layer 2/3 (L2/L3) traffic generation, and full RFC2544 Ethernet testing. The tester serves as a simple loopback device to partner with other Ethernet testers in the JDSU portfolio. The SmartClass Ethernet now has Multiple Streams and Multiprotocol Label Switching (MPLS) options to allow policy testing in converged triple-play networks, and the Asymmetric RFC2544 option enables easy verification of services with different up and downstream data rates. View the online demonstration of the tester at www.jdsu.com/smartclass-ethernetdemo. Feature Ethernet/ Analysis, Filtering, and Traffic Generation VLAN, Q-in-Q, and MPLS Support RFC2544 Traffic Testing Physical Layer Diagnostics Graphical Reporting Loopback Testing Ping and Traceroute Support Functionality Filters and analyzes incoming traffic to determine throughput and quality of service (QoS) metrics. Generates traffic to ensure that QoS parameters are being met by emulating customer traf fic. Use multiple streams to verify correct traffic prioritization. Checks VLAN, Q-in-Q, and MPLS mappings and prioritizations are set properly in the network. Checks that service level agreements (SLAs) can be met by testing in accordance with this accepted method. Checks that circuit is up and connected, and that physical layer is correct. Checks optical link for loss. Generates professional report for validating or storing service level testing results. Enables a JDSU-compatible low-cost single-ended loopback device for testing across a switched or routed Ethernet network. Checks for connectivity between locations. WEBSITE: www.jdsu.com/test

SmartClass Ethernet SmartClass Ethernet SmartClass Ethernet SMARTCLASS ETHERNET 2 Advanced Testing Applications Multiple Streams Testing Option The Multiple Streams option enables the SmartClass Ethernet to simulate eight different sources of traffic from one Ethernet port. Technicians can configure eight independent traffic flows with individual source and destination media access control (MAC) or addresses, tagged with configurable VLAN or Q-in-Q identifiers, and set with a user-configurable frame size and a traffic rate. By examining frame loss, throughput, and identifiers per stream a receiving JDSU tester can verify if the network transported the frames with the expected priority and bandwidth or whether frames reached the destination at all. This test gives service providers a cost-effective method for testing the integrity of policies designed to enable the delivery of differentiated services, such as triple play. MPLS Testing Option The MPLS option lets service providers generate traffic with two MPLS labels and priorities. Testing end-to-end with another tester or to a loop lets field technicians verify that traffic is correctly passed through a MPLS domain and reaches its intended destination with the right bandwidth and priority. MPLS Tag #1 MPLS Tag #2 LSR LSR E-LSR MPLS Tag #1 MPLS Tag #2 LSR LSR Turning up and Verifying MPLS domains with SmartClass Ethernet MPLS Test Option Transmit Labeled Traffic into the MPLS domain Check for the presence of test traffic with the correct labels at other test points Check for test traffic to arrive at destination Edge label switched router tag removal Check for Throughput/Packet Loss/Prioritization Errors

SMARTCLASS ETHERNET 3 Asymmetric RFC2544 Test Suite Option Some services are provisioned to have different up and downstream data rates. Testing these services with a loop can only verify service performance of the lowest half of the link. The Asymmetric RFC2544 option provides an automated version of RFC2544 that can determine the maximum throughput, back-to-back frames, frame loss rate, and jitter for each direction of the link independently. This test provides verification of network policies designed to throttle bandwidth on one half of the Ethernet circuit. Two Asymmetric RFC2544-enabled SmartClass units are required to conduct this test. VLAN Protocol Support Generating an Ethernet traffic stream with a specific VLAN ID and priority (IEEE 802.1q/802.1p) enables technicians to verify the correct transmission and prioritization of the stream through the network. Additionally support for Q-in-Q (VLAN stacking, or 802.1ad) protocols, allows the generation and analysis of both service provider and customer VLANs. The setting of filters lets users isolate a specific VLAN stream to compare its performance with the total performance of the link. VLAN filtering comes standard; however, generating VLAN frames requires purchasing the Traffic option. MAC 20 Port MAC 30 Port Customer A VLANs VLAN 20, 30 MAC 100 MAC 100 20 30 Port Port Carrier Switch Overlapping VLAN IDs between customers MAC 200 30 Port VLAN 10 MAC 200 40 Port UNI EVC1 VLAN 20 VLAN 30 Customer B VLANs VLAN 30, 40 EVC2 VLAN Tagging/Stacking (Q-in-Q) Ethernet packet can enter the network two ways Untagged Ethernet packet With VLAN tag Single or stacked (Q-in-Q) Provider will add a tag to the packet at the Edge device Rate-limiting policies take place at the Provider Edge router MAC 30 Port MAC 40 Port Ping and Traceroute The Traffic option includes the Ping and Traceroute functions, which lets technicians check end-to-end connectivity in a routed network. Traceroute lets users segment a problem further or map the network connections.

SmartClass Ethernet SMARTCLASS ETHERNET 4 10M-1G Ethernet Testing Loopback Testing The SmartClass Ethernet is available in a simple L2-L4 loopback device configuration for other testers in the JDSU portfolio, such as the T-BERD /MTS-8000, T-BERD /MTS-6000A, FST-2802, HST-3000, QT-600, and SmartClass Ethernet. A far-end device, such as the T-BERD/MTS-6000A, can command the SmartClass Ethernet to apply a loop and then generate traffic toward it. Technicians can measure parameters, such as round-trip delay and throughput, on the far-end device using the SmartClass Ethernet to loop traffic back. The SmartClass Ethernet Loopback mode enables selected Ethernet traffic to be looped back from a live link, which enables technicians to loop back test traffic only, conduct loopback testing on a live network in the presence of non-test traffic. EAR SER Metro Ethernet Network EAR TB/MTS-8000 UNI Demarcation Point EAR CE UNI Demarcation Point SmartClass Business Location A FST-2802 HST-3000 Business Location B Ethernet and Traffic Generation, Analysis, and Filtering The SmartClass Ethernet offers a 1 G optical and a 10/100/1000 Mb/s electrical Ethernet port that can be optioned to provide Ethernet and traffic transmit capabilities. The Traffic Option lets technicians generate Ethernet or frames with configurable parameters, such as bandwidth utilization, frame length, and frame payload with varying traffic speeds and flow types. Configure packets with different destination addresses, source address, type of service (TOS)/ Differentiated Services Code Point (DSCP) field, and MPLS labels or virtual local area network (VLAN) tags. Use the Dynamic Host Configuration Protocol (DHCP) server to assign the address of the tester to prevent address clashes. The SmartClass Ethernet can transmit traffic to measure throughput of the network, latency, loss, jitter (RFC3393) and packet/frame errors characteristics necessary to verify QoS is set to correctly deliver the Ethernet service according to the customer s service level agreement, which can also prove network capability for transporting real-time applications such as voice and video traffic.

SmartClass Ethernet SMARTCLASS ETHERNET 5 Optical Option The SmartClass Ethernet comes as standard with a 1Gb/s line rate RJ45 electrical connection. Additionally, the unit may be ordered with the small form-factor, pluggable (SFP) port enabled so the unit can generate line rate optical Ethernet traffic. The SmartClass Ethernet can support SX, LX, ZX, BX, and coarse wavelength division multiplexing (CWDM) interfaces at 1000 Mb/s. RFC2544 Automated Test To verify that they are meeting SLAs, service providers often run a full suite of tests at turn-up known as the RFC2544, which are wrapped into an easy-to-use auto test on the SmartClass Ethernet. With one button press, technicians can configure the link with their saved settings and tests against customizable thresholds, thus performing the test the same way every time with consistent, repeatable results. SmartClass Detects problem as open 50 m away on pair 4 Physical Layer Diagnostics On electrical Ethernet circuits, the SmartClass Ethernet can display the link speed, link status, cable status, media dependent interface/media dependent interface crossover (MDI/MDIX) type, and distance-to-fault with one button press. To verify connectivity on fiber links, it reports the power level of the optical signal. These features let technicians quickly identify physical layer problems. Graphical Reporting All test results are safely stored within the SmartClass Ethernet unit and can be easily retrieved and turned into a report using JDSU Download Manager software, included with each unit. Save reports in an Excel spreadsheet, text, or PDF format. Test reports graphically show end customers network performance test results or can document information about network performance for internal use. Throughput Test Results

SMARTCLASS ETHERNET 6 Specifications and Features Interfaces Electrical Ethernet/ 100/100/1000 Mbps Single RJ45 Optical Ethernet/ 1000 Mbps SFP Interface Modes of Operation Traffic, Streams, RFC2544, Asymmetric RFC2544, Loopback, Pattern, Ping,Traceroute, Cable Test, and Optical Power Measurements Traffic Testing Link Configuration Duplex Modes Full/Half Flow Control Auto-negotiation Traffic Generation Ethernet Constant, Ramp, Bursty, Flood Configurable source and destination MAC address,frame format, frame length (including undersized and jumbo frames), VLAN ID,VLAN priority,frame payload,utilization %,configurable SVLAN ID, SVLAN priority, SVLAN DEI, SVLAN TPI, CVLAN ID, CVLAN priority Constant, Ramp, Bursty, Flood, Ping,Traceroute configurable source and destination address, subnet mask, default gateway, TTL, packet length (including undersized and jumbo frames), packet payload, utilization %,TOS/DSCP configurable DHCP server address for static or dynamic addressing ARP support, MPLS Ethertype, 2 MPLS labels, MPLS ID, MPLS priority, MPLS TTL, MPLS ARP enable/disable Ethernet Streams Constant Per stream configurable source and destination MAC address, frame format, frame length (including undersized and jumbo frames),vlan ID,VLAN priority, frame payload, utilization %, configurable SVLAN ID, SVLAN priority, SVLAN DEI, SVLAN TPI, CVLAN ID, CVLAN priority Streams Constant Per stream configurable source and destination address, subnet mask, default gateway,ttl, packet length (including undersized and jumbo frames), packet payload, utilization %, TOS/DSCP configurable DHCP server address for static or dynamic addressing ARP support, fill byte,vlan ID,VLAN priority, frame payload, utilization %, configurable SVLAN ID, SVLAN priority, SVLAN DEI, SVLAN TPI, CVLAN ID, CVLAN priority Traffic Filtering MAC source and destination address, SVLAN ID, SVLAN priority, SVLAN TPI, CVLAN ID, CVLAN priority source and destination addresses, prefix length,tos/dscp fields RFC2544 and Asymmetric RFC2544 Automated Testing Throughput Latency (RTD) Frame Loss Back-to-back Frame Jitter Bit Error Testing Patterns Layer 2 (Framed) Bit Error Patterns PRBS (2 23-1, 2 31-1, and inverted selections) All Ones, All Zeros, User Defined Framed Pattern NCITS TR-25:1999 Long continuous random test pattern (CRPAT) Long continuous jitter test pattern (CJPAT) Long compliant supply noise pattern (CSPAT) Key Results Link Status Link active Frame detected Sync obtained Configuration Status Auto-negotiation link configuration ACK Auto-negotiation link advertisement status Destination MAC address, when using ARP Link Stats Bandwidth utilization, frame rate, RX/TX L1 Mbps, RX/TX L2 Mbps, round-trip delay, service disruption time, CVLAN ID, SVLAN ID, CVLAN priority, SVLAN priority, Avg and Max packet jitter Link Counts Total received and transmitted frames, pause frames,vlan frames, unicast frames, multicast frames, broadcast frames, frame length (Bins) Error Counts FCS errored frames, runts, jabbers, undersized frames, OOS frames, lost frames, checksum errors, packet length errors, JDSU payload errors Multiple Stream Results Summary: status, sync, link active, errors Config Status: source and destination, subnet mask, gateway addresses per stream Link Stats: bandwidth utilization, frame rate, RX/TX L1 Mbps, RX/TX L2 Mbps, service disruption time Link Counts Total received and transmitted frames, pause,vlan, Q-in-Q, unicast, multicast, broadcast, spanning tree frames, RX/TX frame bytes, frame length (Bins), RX collisions,tx collisions,tx late collisions,tx defers Error Stats FCS errored frames, runts, jabbers, undersized frames, lost frames, frame loss ratio, checksum errors, packet length errors, JDSU payload errors Per Stream Results Bandwidth utilization (Avg, Current, Min, Max), RX Acterna frames, L1 RX Mbps, L2 RX Mbps, delay (Current, Avg), packet jitter (Avg), lost frames, frame loss ratio Physical Testing Link speed, link status, cable status, MDI/MDIX, distance to fault, pin mapping, pair length, polarity, skew Optical power measurement (dbm) Power Supply 4 AA field-replaceable batteries (NiMH and Alkaline) Battery operating time approx. 4 hrs of typical usage Supports sleep mode (instant-on, auto power off after 2 hrs) AC line operation via external adapter/charger AC converter provides country specific adaptor support (USA, UK, Australia, Europe) Charging time, internal: 4 hrs from empty to full Language Support The SmartClass Ethernet supports Simplified Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Russian, and Spanish General Permissible Ambient Temperature Nominal range of use 0 to +50 C Storage and transport 10 to +60 C Humidity Operating humidity 10 to 90% Physical Size (H x W x D) 230 x 120 x 50 mm (9-1/16 x 4-3/4 x 2 in) Weight, including batteries <1 kg (2 lb) Display 320 x 240 pixel color

SMARTCLASS ETHERNET 7 Ordering Information Packages CSC-ETHLP-P1 CSC-ETHLP-P2 CSC-ETHLP-P3 CSC-ETHTR-P1 CSC-ETHTR-P2 CSC-ETHTR-P3 Electrical only loopback Optical and electrical loopback Optical and electrical loopback with accessories (SX and LX SFPs and multimode + single-mode fibers with LC+SC connectors) Electrical traffic Optical and electrical traffic Optical and electrical traffic with accessories (SX and LX SFPs and multimode + single-mode fibers with LC+SC connectors) Accessories CSC-OPT CSC-TRF CSC-MPLS CSC-MPLS-U1 CSC-ASY CSC-ASY-U1 CSC-MSTR CSC-MSTR-U1 AC-SFP-1000LX AC-SFP-1000SX AC-SFP-1000ZX AC-SFP-1000BX1 AC-SFP-1000BX2 AC-SFP-CWDM-1 AC-SFP-CWDM-2 AC-SFP-CWDM-3 AC-SFP-CWDM-4 AC-SFP-CWDM-5 AC-SFP-CWDM-6 AC-SFP-CWDM-7 AC-SFP-CWDM-8 Optical Option Traffic Option MPLS Option MPLS Field Upgrade* Asy. RFC2544 Option Asy. RFC2544 Field Upgrade* Multiple Streams Option Multiple Streams Field Upgrade* 1000LX SFP 1000SX SFP 1000ZX SFP 1310 nm TX, 1490 nm RX, Single mode SFP 1490 nm TX, 1310 nm RX, Single mode SFP 1471 nm CWDM SFP 1491 nm CWDM SFP 1511 nm CWDM SFP 1531 nm CWDM SFP 1551 nm CWDM SFP 1571 nm CWDM SFP 1591 nm CWDM SFP 1611 nm CWDM SFP + assorted cables * -U1 part codes apply for only Release 3 and above SmartClass Ethernet Units.To find out how to upgrade a unit, go to www.jdsu.com.

SMARTCLASS ETHERNET Test & Measurement Regional Sales NORTH AMERICA TEL: 1 866 228 3762 FAX: +1 301 353 9216 LATIN AMERICA TEL: +1 954 688 5660 FAX: +1 954 345 4668 ASIA PACIFIC TEL: +852 2892 0990 FAX: +852 2892 0770 EMEA TEL: +49 7121 86 2222 FAX: +49 7121 86 1222 www.jdsu.com/test Product specifications and descriptions in this document subject to change without notice. 2009 JDS Uniphase Corporation April 2009 30149066 004 0409 SMCLASSETHGIGE.DS.ACC.TM.AE