Important Safeguards

Similar documents
AIR CONDITIONER INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Use and Care Manual. Model CPA12KH AIR CONDITIONER

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

PORTABLE AIR CONDITIONER (LOCAL)

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Meaco 30L and Meaco 40L dehumidifier instruction manual

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Split Type Room Air Conditioner. KSWM units

REMOTE CONTROL MANUAL

Instruction manual for Firstline FCS12000CH

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Dehumidifier Users manual. For Models: DH45S DH65S

DUCT TYPE AIR CONDITIONER

OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Reverse Cycle Inverter Split System Air Conditioner

WINDOW ROOM AIR CONDITIONER

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

FOXAIR 60/50 ALL MODELS

USER S MANUAL HSC-24A

Operating Instructions Split System Air Conditioner

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Climax Air Inc. DC Inverter Portable Air Conditioner Model VS12 12,000 BTU Introducing The World s Most Efficient Portable Air Conditioner

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Taurus Series YORK Window Air Conditioners

SAFEGUARDING THE ENVIRONMENT

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

INDOOR UNIT/OUTDOOR UNIT

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

Contents. Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Room Air Conditioners

Split Air Conditioner

Troubleshooting Your Refrigerator

Inverter Single Zone Ductless Mini Split Heat Pump

Single Zone LCD Thermostat Operating Instructions

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Platinum Range PLAC12000HP PORTABLE AIR CONDITIONER WITH HEAT PUMP USER MANUAL HIGH MID COLL HEAT DRY FAN LOW F C TIMER SLEEP SWING

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

HIGH-WALL DUCTLESS AIR CONDITIONING SYSTEM

Operating Instructions Air Conditioner

OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24. Wall Mounted Unit

Portable Air Conditioner INSTRUCTION MANUAL

GENANO 4500 MEDICAL AIR PURIFICATION DEVICE

AIR CONDITIONER (SPLIT TYPE)

Installation Instructions and Owner's Manual. Double-Hung Windows Room Air Conditioner. This manual must be left with the owner of the equipment.

OPTIONAL SLENDER REMOTE CONTROL

Single Day Alarm Clock with. Bluetooth and USB Play-through

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8

evo + HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL Models: GWH09AB-D3DNA2D GWH18AC-D3DNA2D GWH24AC-D3DNA2D

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

VACUUM CLEANER INSTRUCTION MANUAL

LG Room Air Conditioner OWNER'S MANUAL

R410A SPLIT SERIES DC INVERTER

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Get Me Cool Now Portable Air Conditioner User s Manual

AIR CONDITIONER Duct Type OPERATING MANUAL

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH

Room Air Conditioners

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Central Air Conditioner

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

SWIMMING POOL HEAT PUMP

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL

Portable Air Conditioner

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:


Transcription:

Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the Control Panel...6 COOL Mode...7 DRY Mode...7 FAN Mode...7 HEAT Mode...8 SMART mode...8 POWERFUL mode...8 Remote Control...9 Operating from the Remote Control...10 POWERFUL mode...10 SLEEP mode...10 SWING function...10 PROGRAMMING start up...11 PROGRAMMING shut down...11 Self-Diagnosis...11 Tips for Correct Use...12 Cleaning...12 Cleaning the Cabinet...12 Cleaning the Air Filters...12 Start/End of Season Operations...13 Start of season checks...13 End of season operations...13 Troubleshooting...13 Technical Specifications...14 1

Important Safeguards Use this appliance only as described in the instruction manual. As with all electrical equipment, while instructions aim to cover as many eventualities as possible, caution and common sense should be applied when operating and installing this appliance. This appliance is designed for home air conditioning and must not be used for other purposes. It is dangerous to modify or alter the characteristics of the air conditioner in any manner. The appliance must be installed in conformity with national legislation regulating electrical equipment and installations. If the air conditioner requires repair, contact the Kogan customer support team, as repairs carried out by unauthorised repair centres may be dangerous. Do not allow children to play with the air conditioner. Never allow the air conditioner to be used by people (including children) with psychological, physical or sensory impairments, or with insufficient knowledge and experience, unless they are closely supervised and instructed by someone responsible for their safety. Young children should be supervised to ensure that they do not play with the appliance. Do not use extension cords. Before cleaning or maintenance, always unplug the air conditioner from the mains power. Never unplug the appliance by pulling on the power cable. Hold the plug and pull. Do not install the air conditioner in rooms containing gas, oil or sulphur. Do not install near sources of heat. Do not rest heavy or hot items on top of the air conditioner. Clean the air filter at least once a week. Avoid using heating appliances near the air conditioner. Always transport the air conditioner upright or resting on one side. Before moving the air conditioner, empty the internal circuit of water completely. After moving the unit, wait for at least one hour before starting it. When putting the air conditioner into storage, do not cover it with plastic bags. The materials used for packaging can all be used for recycling. If the power cable is damaged, it must be replaced by a Kogan technician. At the end of its service life, do not dispose of the air conditioner with the regular household waste. It should be taken to an electrical disposal facility for correct disposal. 2

Product Layout 3

Preparing for Use These instructions will enable you to prepare your air conditioner for operation as efficiently as possible. Before use, make sure the air intake and outlet grilles are unobstructed. Air-conditioning without installation Just a few simple steps and your comfort is ensured: Fit the air exhaust hose into the housing at the back of the unit. (Fig 1) Fit the window outlet to the end of the hose. Place the air-conditioner near a window or French window. Adjust the length of the hose so that it reaches the window. Make sure the air exhaust hose is unobstructed. Open the window or French window slightly and position the outlet. (Fig 2) If you have a sash window, place the bracket on the windowsill, then extend the bracket fully within the window frame and fix the bracket using the pin. Once done, lower the window onto the bracket. Insert the window outlet of the exhaust hose into the slot, then connect the hose to the air conditioner. (Fig 3) If you have a double window, use the sucker provided to hold the two parts of the window together. (Fig 4) Keep the air hose as short and free of curves as possible to avoid bottlenecks. 4

Air-conditioning with installation If required, your air-conditioner can be installed semipermanently (Fig. 5). Proceed as follows: Drill in an outside wall or in the window pane a 134mm dia hole, following the heights shown in Fig 6. In the window pane Fit the flange accessory provided in the hole following the instructions given in Figs 7, 8 and 9. Fit the hose in the housing at the back of the appliance. Fit the end of the hose to the flange and shown in Fig 6. When the hose is not fitted, the hole can be closed with the flange cap. Keep the air hose as short and free of curves as possible to avoid bottlenecks. In the wooden kickboard of a French window When installing the air-conditioner semipermanently, you should leave a door slightly open (as little as 1cm) to guarantee correct ventilation. In the wall We recommend that you insulate the section of wall with suitable insulation. 5

Control Panel 1. COOL symbol 2. DRY symbol 3. FAN symbol 4. HEAT symbol 5. SMART symbol 6. POWERFUL symbol 7. Temperature indicator 8. Timer symbol 9. Alarm symbol 10. AUTO FAN indicator 11. FAN SPEED indicator 12. 13. MODE button (selects modes) 14. POWERFUL button 15. FAN button 16. 17. Increase and decrease temperature button Sleep symbol ON/OFF button Operating from the Control Panel The control panel enables you to manage all of the main functions of the appliance, but to make full use of all of the product potential, you must use the remote control. Turning the appliance on Plug air-conditioner into the mains power. Two lines will appear on the display indicating that the airconditioner is in standby mode. Press the power button until the appliance comes on. The last function active when it was last turned off while still be active. Never turn the air-conditioner off by unplugging it from the wall. Always press the power button, then wait for a few minutes before unplugging the unit. This will allow the unit to perform a cycle of operational checks and shut-down processes. 6

COOL Mode Ideal for hot muggy weather when you need air conditioning and dehumidifying in a room. To set this mode correctly: Press the MODE button a number of times until the COOL symbol appears. Select the target temperature by pressing the or button until the desired temperature is displayed. Select the required fan speed by pressing the FAN button. Four speeds are available. Low speed: for silent operation Medium speed: reduced noise level but quicker comfort Maximum speed: achieve target temperature as rapidly as possible AUTO FAN: the air-conditioner automatically selects the most suitable fan speed in relation to the temperature set on the digital display. The most suitable temperature in a room during summer is between 24 C and 27C. It is not recommended to set a temperature too much below the outdoor temperature. DRY Mode Ideal to reduce room humidity (spring and autumn, damp rooms, rainy warm weather etc..) In dry mode, the air-conditioner should be prepared in the same way as for cooling mode, with the air exhaust hose attached to enable the moisture to be discharged outside. To set this mode correctly: Press the MODE button a number of a times until the DRY symbol appears. In this mode, fan speed is selected automatically by the air-conditioner and cannot be set manually. FAN Mode When using the air-conditioner in this mode, the air hose does not need to be attached. To set this mode correctly: Press the MODE button a number of times until the FAN symbol appears. Select the required fan speed by pressing the FAN button. In this mode, you can select low, medium or maximum fan speed. There is no AUTO FAN speed for this mode. 7

HEAT Mode Press the MODE button a number of a times until the DRY symbol appears. Select the target temperature (13-27 C) by pressing the or button until the corresponding value is displayed. In heating mode, the fan speed is selected automatically by the unit. Water is removed from the air and will collect in the tank. When the tank is full, the unit will shut down and Ft (full tank) will appear on the display. The tank cap must be extracted and emptied. When all water has been drained, put cap back in place. When tank has been emptied, unit will start up again. Note: when operating in cold rooms, the unit will defrost automatically, which may momentarily interrupt operations. Lt will appear on the display during this operation. In this mode, it may take a few minutes for hot air to start being blown out of the unit, and the fan may cut in and out for short periods of time, even if the set temperature has been reached. SMART mode The air-conditioner will automatically select whether it should function in air-conditioning or fan mode. To set this mode: Press the MODE button a number of times until the SMART symbol appears. POWERFUL mode Ideal for the summer to cool rooms rapidly. Active by simply pressing the POWERFUL button. The appliance operates in cool mode at maximum fan speed. While this function is selected, it is not possible to set the temperature or change the fan speed. 8

Remote Control 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. Mode indicator Selected temperature scale indicator Signal transmission Auto fan speed indicator Fan symbol Sleep indicator Powerful indicator Swing indicator Programming start up/shut down Increase and decrease temperature/time button ON/OFF button MODE button (selects the modes) FAN button POWERFUL button SWING button TIMER button SLEEP button Reset button (resets air-conditioner unit to the original default factory settings) Correct Use Point the remote control at the receiver on the air-conditioner. The remote control must be no more than 7 metres away from the air-conditioner (with no obstacles between the remote control and the receiver). The remote control must be handled with care. Do not drop it or expose it to direct sunlight or other sources of heat. Replacing the batteries 1. Remove the cover on the rear of the remote. 2. Insert 2 x AAA batteries, taking care to match the polarities of the batteries with the markings inside the battery compartment. 3. Replace the cover. To cancel the settings programmed on the remote control and restore the original settings, press the RESET button lightly with the point of a pencil or pen. 9

Operating from the Remote Control The first part of the controls on the remote control are the same as those on the control panel of the appliance. You should therefore refer to the instructions in the chapter Operating from the Control Panel to turn the appliance on and select the operating modes and fan speeds. The following section describes the additional functions corresponding to the controls on the bottom section of the remote control. POWERFUL mode Ideal for the summer to cool rooms rapidly. Active by simply pressing the POWERFUL button. The appliance operates in cool mode at maximum fan speed. While this function is selected, it is not possible to set the temperature or change the fan speed. SLEEP mode This function is useful for the night as it will gradually reduce the operation of the appliance. To set this function correctly: Select operating mode (cool, dry or smart) as described. Press the SLEEP button. The appliance will operate in the previously selected mode. The SLEEP function maintains the room at the optimal temperature or humidity with silent functionality. Fan speed will always be at the minimum, while the room temperature and humidity vary gradually to ensure the most comfortable sleeping conditions. When the sleep function is active, in order to supply further comfort to your sleeping, the set temperature will increase by 1 C after 1 hour, then increase another 1 C after 2 hours, then will stay at this setting. SWING function This function is useful for selecting the left/right swing of air delivery. To set this function correctly: Select the operating mode (cool, dry, fan or smart) as described. Press the SWING button. The appliance will operate in the previously selected mode, with the icon showing on the remote to indicate that the swing is active. Press the swing button again to stop the swing function. The icon will disappear. 10

PROGRAMMING start up Press the TIMER button once. The message will flash on the remote display. Press the MODE button to set the working mode you need. (For example, cool mode, 25C, high fan speed) Press the TIMER button again. The start-up time and message will flash on the remote control display. Press the or buttons to set the time you want the airconditioner to start up (from 1 hour to 12 hours). When that time is reached, press the TIMER button to confirm. The message will appear on the remote control display and the symbol will be displayed on the air-conditioner itself to indicate that the timer is active. At the end of the set time, the air-conditioner will switch on automatically and operate in the working mode previously set. To cancel the timer setting, press the TIMER button again whenever during the set time. PROGRAMMING shut down Press the TIMER button once. The shutdown time and message will flash on the remote control display. Press or buttons to set the time you want the airconditioner to shut down (from 1 hour to 12 hours). When the desired time is reached, press the TIMER button to confirm. The message will appear on the remote control screen and the symbol will appear on the air-conditioner to indicate the timer is active. To cancel the timer setting, press the TIMER button again at any point during the set time. Self-Diagnosis The air-conditioner has a self diagnosis system used to diagnose a number of malfunctions. Error messages are displayed on the display screen. Message Low Temperature (Frost prevention) Action The air-conditioner is fitted with a frost protection device to avoid excessive formation of ice. The appliance will start up again automatically when the defrosting process is complete. Contact the Kogan customer support team. Probe Failure (Sensor damaged) 11

Empty the internal safety tank, following the instructions in the End of Season Operations section. Full Tank (Safety Tank Full) Tips for Correct Use To get the best from your air-conditioner, follow these recommendations. Close the windows and doors in the room to be air-conditioned. When installing the air-conditioner semi-permanently, you should leave a door slightly open (as little as 1cm) to guarantee correct ventilation. Protect the room from direct exposure to the sun by partially closing curtains or blinds to make the air-conditioner more economical to run. Never rest objects of any description on the air-conditioner. Do not obstruct the air intake and outlet. Leave the grills free. Make sure there are no heat sources in the room. Never use the appliance in an excessively damp room (such as a laundry or room with a shower). Never use outdoors. Make sure the air-conditioner is standing on a level surface. If necessary, place castor locks under the front wheels. Cleaning Before cleaning or performing maintenance, turn the air-conditioner off my pressing the '' button on the control panel or the ON/OFF button on the remote control. Wait for 5 minutes, then unplug the unit from the wall power supply. Cleaning the Cabinet You should clean the air-conditioner with a slightly damp cloth, then dry with a soft dry cloth. Never wash the air-conditioner with water. It may be dangerous. Never use petrol, alcohol or solvents to clean the air-conditioner. Never spray insecticide liquids or similar into or onto the air-conditioner. Cleaning the Air Filters To keep you air-conditioner working efficiently, you should clean the filter once every week of operation. The filters are housed in the intake grille, as shown to right. Use a vacuum cleaner to remove dust accumulations from the filter. If it is very dirty, immerse in warm water and rinse a number of times. The water should never be hotter than 40 C. After washing, leave the filters to dry, then attach the intake grille to the airconditioner. 12

Start/End of Season Operations Start of season checks Make sure the power cable and plug are undamaged and in good working order. Follow the installation instructions precisely. End of season operations To empty the internal circuit of water completely, remove the cap as shown. Run off all water into a basin, tray or simply onto the ground outside. Once all water has been drained, put the cap back into place. Clean the air filter and dry thoroughly before putting back into the unit. Troubleshooting Problem Cause Solution Air-conditioner does not turn on. There is no power. Not plugged in. Safety switch has triggered. Wait. Plug into the mains. Wait 30 minutes, if the problem persists, contact Kogan customer support. Air-conditioner works for a short time only. There are bends in the exhaust hose. Something is preventing the air from being discharged. Position the air exhaust hose correctly, keeping it as short and free of curves as possible to avoid bottlenecks. Check and remove any obstacles that may be blocking air flow. Windows, doors and/or curtains open. There are heat sources in the room. Air exhaust hose has detached from unit. Technical specifications of the unit is not adequate for the room in which it is located. Air conditioner is working but it is not cooling the room. Close doors, windows and curtains, bearing in mind the tips for correct use on page 10. Eliminate the heat sources. Fit the air exhaust hose to the housing at the back of the unit. Move air-conditioner to a smaller room that suits its specifications. During Operation, there is an unpleasant smell in the room. The air filter is clogged. Clean the filter as described on page 11. The air-conditioner does not operate for about 3 minutes after restarting it. The internal compressor safety device prevents the unit from being restarted for three minutes after it was last turned off. Wait. This delay is part of normal operations. The following messages display on the panel: Lt / PF / Ft The appliance has a selfdiagnosis system and has diagnosed an error. Refer to the Self-Diagnosis chapter on page 10. 13

Technical Specifications Mains Voltage See ratings label on product. Max. Power Usage See ratings label on product. Refrigerant See ratings label on product. Cooling Capacity See ratings label on product. Volume of Water Tank 3 litre Protection Degree IPX0 Dimensions 463 x 775 x 382mm 14