CUKUROVA GENERATOR SYSTEMS



Similar documents
CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

BCI184E - Technical Data Sheet

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PM734F - Technical Data Sheet Winding 28

Diesel Generating Set

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

Annex-A TECHNICAL SPECIFICATION

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

DIESEL GENERATOR SETS

Diesel Engine Driven Generators Page 1 of 6

Spark-ignited generator set

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

How To Control A Power Command Powerplant

C18 ACERT Fire Pump Tier bkw/ rpm

Diesel Generator Set Model DFHC 60 Hz

Diesel Generator Set Model DFMB 60 Hz

Marine Generating Sets 3.7 to 50 kva

Atlas Copco Generators

A Single Source for all Power System Solutions

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

STAMFORD Product Guide

Diesel Generator Set Model DGDK 60 Hz

How To Use A Cat Diesel Engine

Magnum Mobile Generator MMG55 Specifications

IGSA POWER GENERATION SYSTEMS

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

C18 Diesel Oilfield Generator Set

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

1013 E. The engine for agricultural equipment.

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

The Yachtmans Choice...

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

TECHNICAL SPECIFICATIONS FOR DIESEL GENERATORS 15KVA (CANOPY TYPE)

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

APS100 Rental Generator Set Specification

OPTIONAL FEATURES 30

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Generators TEM. for small hydroelectric power stations. Electric Machines

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

R448 & R448 V50 A.V.R.

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

Power Generation. Power Control PCL System Generator Set Control

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

Single-Phase AC Synchronous Generator

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

ECOCIAT. Domestic hot water heat recovery unit

CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C. Hatz Diesel.

Unit 96: Marine Propulsion Power Plant

Technical Specification. Generating Set with Waukesha engine burning natural gas

@Perkins Series The Start of A New

Automatic Voltage Regulator User s Manual

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

912. The engine for construction equipment.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

The kva RAnge

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Oil and Coolant Circulating Heating System. Model - OCSM

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

The reliability of the grid

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Transcription:

Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 2806A-E18TAG2 diesel engine Newage/Stamford HCI544F alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty type, 6 cylinder, water cooled engine 50 C tropical type radiator Starter motor Lead acid battery Charging alternator Battery charge redressor Heavy duty, brushless type alternator Base frame with anti-vibration units Industrial type silencers Flexible exhaust compensator Block water heater unit Control panel with digital-automatic main control module Fan, fan drive, charging alternator drive and all rotating parts covered Radiator matrix covered by metal mesh against the mechanical damages Fabricated and welded steel base frame Anti-vibration mountings Engine and alternator manufacturer test reports Factory load, performance and function tests Optional Features ISO ISO 9001:2000 Cukurova is a fully accrediated ISO 9001:2000 company This generator is available with CE certification Automatic load transfer panel Automatic syncronization and power sharing systems Soundproof canopy Container type enclosers Road trailer Job-site trailer Protection circuit breaker Air start Remote type radiator Base fuel tank External type fuel tank Automatic fuel transfer system Residential silencer Standby Prime kva kw kva kw Cukurova is accrediated with Gost certification 720 576 670 536 Technical Data Sheet 061130 - Page1

CUKUROVA Diesel Generator engine APPLICATION DATA Perkins 2806A-E18TAG2 Engine Standard Features Economic power Mechanically operated unit fuel injectors with electronic control combined with carefully matched turbocharging give excellent fuel atomisation and combustion with optimum economy Low emissions result from electronic control of fuel injected Standby kw Prime kw Gross Net Gross Net 2806A-E18TAG2 628 609 584 565 Lubricating System Pressurized Reliable power Capacity, Liters 62 Developed and tested using latest engineering techniques and finite element Lub oil pressure (min), bar 2 analysis for high reliability, low oil usage and low wear rates Wet sump with filler and dipstick High compression ratios also ensure clean rapid starting in all conditions Full-flow replaceable Ecoplus filter Support comes from a worldwide network of 4000 distributors and dealers Oil cooler integral with filter header Compact and efficient power Exceptional power to weight ratio and compact size give optimum power density with easier installation and cost effective transportation Designed to provide excellent service access for ease of maintenance Clean Power The 2806-E18TAG2 is capable of meeting the requirements of TA luft (1986) Standards UK MOD, BS5750, ISO9001, BS5514/1-1982, ISO 3046/1, ISO 8528/1 Technical Specifications Manufacturer PERKINS 2806A-E18TAG2 4 cycle, water-cooled, diesel engine Number of cylinders 6 Cylinder arrangement Vertical in-line Displacement, Liters 18.1 Bore X Stroke, mm 145 X 183 Compression Ratio 14.5:1 Combustion System Direct injection Aspiration Turbocharged, air-to-air charge cooled Rotation Anti-clockwise viewed on flywheel Gross engine power, kwb 628 Fan Power, kwm 9 BMEP gross, bar 27,7 Combustion air flow, m³ / min 40 Exhaust gas temp.(after turbo), C 553 Exhaust gas flow (after turbo),m³ / min 114 Mean piston speed, m / s 9 Cooling System Tropical, heavy duty type Ambient temperature, C 50 Engine+Radiator coolant cap., Liters 61 Jacket coolant flow, Liters / sec 6.1 Cooling min airflow, m³ / min 1170 (at 45 C) Gear-driven circulating pump Mounted belt-driven pusher fan Radiator incorporating air-to-air charge cooler, (supplied loose) System designed for ambients up to 50ºC Low coolant level switch Fuel System of injection system MEUI Fuel injection pump Combined unit injector Delivery/hour at 1500rev/min, Liters 413 Governor type Electronic, governing to ISO 8528-5 class G2 with isochronous capability Mechanically actuated electronically controlled unit fuel injectors with full authority electronic control Replaceable Ecoplus fuel filter elements with primary filter/water separator Fuel cooler Electrical System Alternator 24 Volt with integral regulator Starter motor (DC) 24 Volt Starter motor power 9 kw ECM mounted on engine with wiring looms and sensors 3 level engine protection system Fuel Consumption liters per hour grams per kwh %110 Load %100 Load %75 Load %50 Load %110 Load %100 Load %75 Load %50 Load 143 L 132 L 97 L 66 L 203 g/kwh 202 g/kwh 198 g/kwh 201 g/kwh Optional Equipments Additional speed sensor Temperature and pressure sensors for gauges Electric hours counter Air filter rain hood Twin starters/facility for second starter Technical Data Sheet 061130 - Page2

alternator Newage/Stamford HCI544F Alternator Standard Features Winding&Electrical Performance All generator stators are wound to 2/3 pitch.this eliminates triplen (3rd, 9th, 15th...) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads.the 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains.a fully connected damper winding reduces oscillations during paralelling.this winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. SX440 AVR With this self-excited system the main stator provides power via the Automatic Voltage Regulator (AVR) to the exciter stator. The high efficiency semiconductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-of-phase paralleling. The SX440 will support a range of electronic accessories, including a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators. If 3-phase sensing is required with the self-excited system, the SX421 AVR must be used. Terminals&Terminal Box Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, Which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers wiring and gland arrangements.it has removable panels for easy access. Shaft&Keys All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. Insulation / Impregnation The insulation system is class 'H' All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. Standards Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevent section of other international standards such as BS5000,VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359 Other standards and certifications can be considered on request Quaility Assurance Generators are manufactured using production procedures having a quaility assurance level to BS EN ISO 9001. HCI544F Technical Specifications Manufacturer Standby Prime kva kw kva kw 738 590 670 536 NEWAGE / STAMFORD HCI544F 4-Poles, Rotating Field, Brushless Standby power at rated voltage, kva 738 Efficiency, % 94.6% Power factor 0.8 Phase 3 Frequency, Hz 50 Speed, Rpm 1500 Voltage, V 380/415 Excitation Self excited Stator windings 2/3 Pitch factor Regulation AVR, Automatic Voltage Regulator Voltage Regulator SX440 Voltage Regulation, % ± 1 R.F.I Suppression BS EN 61000-6-2 & BS EN 61000-6-4 VDE0875G, VDE 0875N Waveform distortion No Load <1.5% Non distorting balanced linear load<5.0% Rotor Dynamic balanced Overspeed, Rpm 2250 Short circuit current < 300% TIF Less than 50 Insultion class H Construction Single bearing, direct coupled Coupling Flexible Stator winding Double layer concentric Connection WYE Protection class IP23 Cooling air volume,m³ / sec 1.035 Optional Equipment Optional Permanent Magnet Generator (PMG) provides an isolated power supply to the excitation control system Anti Condensation Heaters Air Filters Temperature Indication RTD s Winding Protection Thermistors Quadrature Droop kit for Parallel Operation SX421 AVR with 3 Phase Sensing and improved Regulation 0.5% MX341 (PMG) 1% Regulation with 2 Phase Sensing MX321 (PMG) with 3 Phase Sensing and improved Regulation 0.5% Technical Data Sheet 061130 - Page3

control panel Control Panel Standard Equipments O I Input Functions display on LCD Generator Volts Generator Volts Generator Amps Generator Frequency Mains Volts Mains Volts Mains Frequency Engine Speed Plant Battery Volts Engine Hours Run Generator total power Generator total power Generator power factor Volts L1-N, L2-N, L3-N Volts L1-L2, L2-L3, L3-L1 Amps L1, L2, L3 Hz Volts L1-N, L2-N, L3-N Volts L1-L2, L2-L3, L3-L1 Hz RPM Volts Hour kva L1, L2, L3,total kw L1, L2, L3,total Cosφ L1, L2, L3,total Deeapse 5220 digital automatic control module Hourmeter Voltmeter Voltmeter commutator Ampermeter Ampermeter commutator Emergency stop button Deepsea 5220 Control Module Description The model 5220 is an Automatic Mains Failure Control module. The modul is used to monitor a mains supply and automaticlly start a standby generator set. The module also provides indication of operational status and fault conditions automaticly shutting down the genset and indicating failures by means of an LCD display, and appropriate flashing LED on the front panel. Selected timers and alarms can be altered by the user from the front panel. Alterations to the system are made using the 810 interface and a PC. This interface also provides real time diagnostic facilities Optional Input Functions Engine Oil pressure Fuel level Engine Temperature Alarm Channels Under/over generator voltage Over-current Under/over generator frequency Under/over speed Charge fail Emergency stop Low oil pressure High engine temperature Fail to start Low/high DC battery voltage Reverse power Generator phase rotation error Generator short-circuit protection Loss of speed sensing signal Mains out of limits kpa % C Specifications Environmental Testing Standards 240mm x 172mm dimensions 70mm x 40mm dimensions, 4 segment grafical LCD monitor Developed 16-bit Microprocessor design Easy comprehended display (Hid-Til-Lit SMD LED technology) LED mimic diagram SMS messaging capability with suitable GSM Modem PC software is MS Windows based and allows the operator to control the module from a remote location (P810 Software Kit necessary) Easy pushbutton controls System parameters can be adjusted manually from the front panel kva,kw ve Cosφ measurements Communication with MODEM Pushbutton Controls STOP / START AUTO, TEST, MANUAL LCD PAGE Electromagnetic Compatibility BS EN 50081-2:1992 and EN 61000-6-4:2000 EMC, Emission Standards for the Industrial Environment EN 61000-6-2:1999 EMC, Immunity Standards for the Industrial Environment Vibration BS EN 60068-2-6 Ten sweeps (up and back down) at 1 octave/minute in each of the three major axes. 5Hz to @ +/-7.5mm constant displacement. 8Hz to 500Hz 2gn constant acceleration. Temperature Cold : BS EN 60068-2-1 to -30 C Hot : BS EN 60068-2-2 to 70 C Humidity BS EN 2011 part 2.1 93% RH @ 40 for 48 hours Shock BS EN 6068-2-27 Three half sine shocks in each of the three major axes 15gn amplitude.11ms duration. Electrical Safety BS EN 60950 Low Voltage Dirctive/Safety of information technology equipments, including electrical business equipment Technical Data Sheet 061130 - Page4

CUKUROVA Diesel Generator Codes and General Information Cukurova Diesel Generator CJ 720 P N N Group - Alternator brand (Newage/Stamford) P Series - Engine brand (Perkins) Standby Power - kva Cukurova generator Perkins 2800 Series Diesel Engine Newage/Stamford Alternator 2806A-E18 T A G 2 HC I 54 4 F Power level Genset engine Core Length Air-to-air charge cooled Number of poles Turbocharged Shaft Height in cm Electronic, 18 liters Industrial Information Power Ratings 2800 Series, 6 cylinder Electric Formulas Generator type Standby power rating is for the supply of emergency power at variable load for the duration of the non-avalaibality of the mains power supply.no overload capacity is available at this rating.a standby rated engine should be sized for an avarage load factor of 80% based on published standby rating for 500 operating hours per year.standby ratings should never be applied except in true emergency power failure conditions. Values Formula kwe kwm X E kwe (U x I x 1.73 x pf) / 1000 kva (U x I x 1.73) / 1000 kva x pf kwe / pf Prime power rating is available for unlimited hours per year with a variable load of which the average engine load factor is 80% of the published power rating, incorporation of a 10% overload for 1 hour in every 12 hours of operation which permitted I (Amp) Frequency (kwe x 1000) / (U x 1.73 x pf) ( Rpm x N Pole) / (2 x 60) (kva x 1000) / (U x 1.73) Continuous power rating is available for continuous full load operation.no overload is permitted. Acc. To ISO 3046/1, BS 5514, DIN6271 Rpm (2 x 60 x Frequency) / N Pole kwm: Mechanical Power I : Current (A) kwe : Electrical Power U : Voltage (V) pf : Power factor kva : Power E : Alternator efficiency Rpm: Revolutions per minute Technical Data Sheet 061130 - Page5

O I CUKUROVA Diesel Generator General Dimensions Standard Generator W Length, L 3,7 m Heigth, H 2 m Width, W 1,6 m H Weight, Total 4.500 kg L Generator with Soundproof Canopy W Length, L 5,4 m Heigth, H 2,9 m H Width, W 1,9 m Weight, Total 6.500 kg L Generator Room Layout 3,5 m 2 m 1,2 m 0,8 m 2 m 2,5 m 7 m Above drawings dimensions and weights are only for guidence.for installation design of your specific application, necessary certified drawings, at site consultancy service as well as maintenance and installations manuals will be provided by Cukurova without any charge. Specifications may change without notice Technical Data Sheet 061130 - Page6