Intel Xeon Processor E5-2600



Similar documents
Innovativste XEON Prozessortechnik für Cisco UCS

LABS. Boston Solutions. Future Intel Xeon processor E v3 product families. September Powered by

A Quantum Leap in Enterprise Computing

Oracle Database Reliability, Performance and scalability on Intel Xeon platforms Mitch Shults, Intel Corporation October 2011

Intel Xeon Processor 5500 Series. An Intelligent Approach to IT Challenges

Intel Xeon Processor 3400 Series-based Platforms

The Foundation for Better Business Intelligence

Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms

Intel Virtualization and Server Technology Update

Intel Core i3-2310m Processor (3M Cache, 2.10 GHz)

Server Bandwidth Scenarios Signposts for 40G/100G Server Connections

Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept

FPO. Expanding Intel Architecture Flexibility in the Data Center. Markus Leberecht Data Center Solutions Architect, Intel EMEA March 20, 2013

Intel Core i Processor (3M Cache, 3.30 GHz)

Memory Configuration Guide

SUN FIRE X4170, X4270, AND X4275 SERVER ARCHITECTURE Optimizing Performance, Density, and Expandability to Maximize Datacenter Value

Intel Xeon Processor E Product Family

The Engine for Digital Transformation in the Data Center

Itanium 2 Platform and Technologies. Alexander Grudinski Business Solution Specialist Intel Corporation

How To Build A Cisco Ukcsob420 M3 Blade Server

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure

Copyright 2013, Oracle and/or its affiliates. All rights reserved.

Intel Xeon Processor 5600 Series

Accelerate Discovery with Powerful New HPC Solutions

HUAWEI Tecal E6000 Blade Server

HP ProLiant BL660c Gen9 and Microsoft SQL Server 2014 technical brief

Intel X58 Express Chipset

WHITE PAPER FUJITSU PRIMERGY SERVERS PERFORMANCE REPORT PRIMERGY BX620 S6

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade

Server: Performance Benchmark. Memory channels, frequency and performance

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION

Stovepipes to Clouds. Rick Reid Principal Engineer SGI Federal by SGI Federal. Published by The Aerospace Corporation with permission.

Memory Configuration for Intel Xeon 5500 Series Branded Servers & Workstations

Optimized dual-use server and high-end workstation performance

Configuring and using DDR3 memory with HP ProLiant Gen8 Servers

I/O Performance of Cisco UCS M-Series Modular Servers with Cisco UCS M142 Compute Cartridges

HETEROGENEOUS HPC, ARCHITECTURE OPTIMIZATION, AND NVLINK

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation

HP PCIe IO Accelerator For Proliant Rackmount Servers And BladeSystems

Achieving a High Performance OLTP Database using SQL Server and Dell PowerEdge R720 with Internal PCIe SSD Storage

FUJITSU Enterprise Product & Solution Facts

New System-on-a-Chip (SoC) Intel Celeron and Pentium Processors Balance Cost, Performance, and Power for Everyday Computing

The Bus (PCI and PCI-Express)

Pioneer DreamMicro. Blade Server S75 Series

HUAWEI E9000 Converged Infrastructure Blade Server

White Paper. Innovate Telecom Services with NFV and SDN

Maximize Performance and Scalability of RADIOSS* Structural Analysis Software on Intel Xeon Processor E7 v2 Family-Based Platforms

Leading Virtualization Performance and Energy Efficiency in a Multi-processor Server

Intel Data Direct I/O Technology (Intel DDIO): A Primer >

OBJECTIVE ANALYSIS WHITE PAPER MATCH FLASH. TO THE PROCESSOR Why Multithreading Requires Parallelized Flash ATCHING

Intel Solid- State Drive Data Center P3700 Series NVMe Hybrid Storage Performance

Boost Database Performance with the Cisco UCS Storage Accelerator

How System Settings Impact PCIe SSD Performance

HUAWEI Tecal E9000 Converged Infrastructure Blade Server

HP ProLiant BL460c Gen8 Server Blade Customer presentation

PSAM, NEC PCIe SSD Appliance for Microsoft SQL Server (Reference Architecture) September 11 th, 2014 NEC Corporation

New levels of efficiency and optimized design. The latest Intel CPUs. 2+1 expandability in UP 1U

High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling

Dell PowerEdge Servers Memory

What are the differences between Intel Core i3, i5 and i7

Intel Open Network Platform Release 2.1: Driving Network Transformation

Fujitsu PRIMERGY BX924 S2 Dual-Socket server

HUAWEI E9000 Converged Infrastructure Blade Server

The MAX5 Advantage: Clients Benefit running Microsoft SQL Server Data Warehouse (Workloads) on IBM BladeCenter HX5 with IBM MAX5.

Power efficiency and power management in HP ProLiant servers

FLOW-3D Performance Benchmark and Profiling. September 2012

Cisco UCS B-Series M2 Blade Servers

Table Of Contents. Page 2 of 26. *Other brands and names may be claimed as property of others.

Big Data Performance Growth on the Rise

Up to 4 PCI-E SSDs Four or Two Hot-Pluggable Nodes in 2U

IBM System x family brochure

Cisco for SAP HANA Scale-Out Solution on Cisco UCS with NetApp Storage

Sun Constellation System: The Open Petascale Computing Architecture

Razor-Thin Laptops Meets Ultra- Fast Tablets with Intel Core M Processor Platforms

OpenPOWER Outlook AXEL KOEHLER SR. SOLUTION ARCHITECT HPC

Intel Itanium Architecture

Cisco UCS B460 M4 Blade Server

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000

Putting it all together: Intel Nehalem.

Redpaper. IBM BladeCenter HS22 Technical Introduction. Randall Davis David Watts

Measuring Cache and Memory Latency and CPU to Memory Bandwidth

Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays. Red Hat Performance Engineering

Application Server Platform Architecture. IEI Application Server Platform for Communication Appliance

How To Use Poweredge R520 (Poweredge) With Poweredge (Power Edge) And Poweredge V2 (Powertower) (Powerenerge) (Dell) (For A Poweredge) (Windows) (Amd) (

Optimizing Infrastructure for Workloads in OpenStack * -Based Public Cloud Services

HP ProLiant Gen8 vs Gen9 Server Blades on Data Warehouse Workloads

New Cluster-Ready FAS3200 Models

White Paper. Intel Sandy Bridge Brings Many Benefits to the PC/104 Form Factor

Performance. Microsoft Dynamics CRM Performance and Scalability with Intel Processor and Solid-State Drive Technologies. Microsoft Dynamics CRM 4.

Transcription:

Intel Xeon Processor E5-2600 Best combination of performance, power efficiency, and cost. Platform Microarchitecture Processor Socket Chipset Intel Xeon E5 Series Processors and the Intel C600 Chipset (formerly codenamed Romley-EP ) Sandy Bridge Intel Xeon E5-2600 Series (formerly codenamed Sandy Bridge-EP") R Intel C600 Chipset (formerly codenamed Patsburg ) Sockets 1 2 Number of Cores 4, 6, or 8 Frequency 8-core CPUs up to 2.9 GHz On Die Cache Up to 20 MB shared L3 Cache Interconnect Type and Speed Quick Path Interconnect (up to 8.0 GT/s) Memory Type DDR3 up to 1600 MT/s Max Memory Capacity Up to 768 GB (on boards with 24 s) I/O Type Intel Integrated I/O supporting latest PCIe 3 specification What s new about the Intel Xeon Processor E5-2600 (formerly codenamed Sandy Bridge-EP on the Romley Platform) Up to 8 cores. Up to 16 threads. Up to 20MB cache. Dynamically scalable microarchitecture offers up to 8 cores per socket, up to 2 threads per core, and up to 20 MB shared cache. PCIe 3.0 doubles the delivered bandwidth of PCIe 2.0 Provides the increased I/O bandwidth required in enterprise deployments, with up to 40 lanes per socket Intel Intelligent Power Technology IPT automatically shifts the CPU and memory into the lowest available power state, reducing energy costs. Intel Turbo Boost Technology 2.0 Optimized Intel Turbo Boost maximizes CPU performance during workload spikes by allowing the CPU to briefly operate above TDP. The processor still operates within a closely controlled thermal envelope, controlled by fuse settings and highly-accurate sensors Intel Hyper-Threading Technology Hyper-Threading allows thread-level parallelism on each processor, resulting in more efficient use of processor resources. With higher processing throughput, you enjoy substantially improved performance. Advanced Instruction Sets Intel AES-NI (Advanced Encryption Standard New Instructions) accelerates encryption and decryption speeds, allowing broader use of encryption to improve data security. Intel Advanced Vector Extensions (AVX) Instructions deliver improved performance on floating point-intensive applications. Intel Virtualization Technology (Intel VT-x, VT-d, VT-c) Higher-level VMM Functions, including resource discovery, provisioning, scheduling, and user interface. Processor virtualization, memory virtualization, I/O device virtualization.

Transitions: Intel Xeon Server Roadmap Intel Xeon 7000 Sequence (4 socket) Premium 4 Socket+ Mainstream 4 Socket Intel Xeon E7 Intel Xeon E5 E7-8800 E7-4800 E7-2800 E5-4600 Intel Xeon 5000 Sequence (2 socket) Entry 4 Socket Premium 2 Socket Entry 2 Socket Intel Xeon E5 Intel Xeon E5 E5-2600 Codenamed Romley-EN Intel Xeon 3000 Sequence (1 socket) Premium 1Socket Entry 1 Socket Intel Xeon E5 Intel Xeon E3 E5-1600 E3-1200

Process TDP 1 CPU Number 32nm Frequency 135W E5-2690 2.9 GHz Cores / Threads Cache QPI Speed Max Mem Speed Turbo Boost Specification Max Turbo Frequency 2 4 / 4 / 4 / 5 / 5 / 7 / 7 / 9 3.8 GHz 130W E5-2680 2.7 GHz 4 / 4 / 5 / 5 / 5 / 7 / 8 / 8 3.5 GHz 115W 95W E5-2670 2.6 GHz 4 / 4 / 5 / 5 / 6 / 6 / 7 / 7 3.3 GHz 8 / 16 20MB 8.0 GT/s 1600 MT/s E5-2665 2.4 GHz 4 / 4 / 5 / 5 / 6 / 6 / 7 / 7 3.1 GHz E5-2660 2.2 GHz 5 / 5 / 6 / 6 / 7 / 7 / 8 / 8 3.0 GHz E5-2650 2.0 GHz 4 / 4 / 5 / 5 / 5 / 7 / 8 / 8 2.8 GHz 130W E5-2667 2.9 GHz 6 / 12 15MB 8.0 GT/s 1600 MT/s 3 / 3 / 3 / 4 / 5 / 6 3.5 GHz 95W 130W 80W E5-2640 2.5 GHz 3 / 3 / 4 / 4 / 5 / 5 3.0 GHz E5-2630 2.3 GHz 6 / 12 15MB 7.2 GT/s 1333 MT/s 3 / 3 / 4 / 4 / 5 / 5 2.8 GHz E5-2620 2.0 GHz 3 / 3 / 4 / 4 / 5 / 5 2.5 GHz E5-2643 3.3 GHz 4 / 8 10MB 8.0 GT/s 1600 MT/s 1 / 1 / 2 / 2 3.5 GHz Yes E5-2637 3.0 GHz 2 / 4 5MB 8.0 GT/s 1600 MT/s 5 / 5 3.5 GHz Yes E5-2609 2.4 GHz n/a 4 / 4 10MB 6.4 GT/s 1066 MT/s E5-2603 1.8 GHz n/a 70W E5-2650L 1.8 GHz 8 / 16 20MB 8.0 GT/s 1600 MT/s 2 / 2 / 3 / 3 / 4 / 4 / 5 / 5 2.3 GHz 60W E5-2630L 2.0 GHz 6 / 12 15MB 7.2 GT/s 1333 MT/s 3 / 3 / 4 / 4 / 5 / 5 2.5 GHz No HT Yes Yes No Yes 1 TDP is Thermal Design Power 2 See pages 7 and 8 for information about interpreting the Turbo Boost specification.. Chip Diagram / Ring Bus The ring bus architecture delivers an efficient bi-directional highway for data movement. The PCI controller has been moved onto the CPU. With the PCIe 3.0 standard supported by these processors, there are 40 PCIe 3.0 lanes per processor. Compared to Xeon 5500/5600: Lower L3 cache latency (~20%) Higher bandwidth between cores, L3, Memory, and I/O Up to 8x more L3-cache-to-core bandwidth The Intel Xeon E5-2600 is the first server processor with integrated PCIe. The E5-2600 supports the PCIe 3.0 specification. PCIe 3.0 delivers breakthrough platform performance and scale Reduces I/O latency by up to 32% Offers up to 40 lanes of PCIe per socket Improves I/O bandwidth by up to 2 times

Chipset / Platform Information Intel C600 Series Chipset Overview (formerly codenamed Patsburg ) All chipsets come with 4 x 3Gb/s SATA ports and 2 x 6Gb/s SATA ports from AHCI. C602J: 6 x SATA ports only C602: 6 x SATA ports + 4 x 3Gb/s SATA ports from SCU C606: 6 x SATA ports + 8 x 3Gb/s SAS ports from SCU + PCIe 1.0 x4 uplink to CPU RAID capabilities: All chipsets include Intel RSTe RAID 0/1/10/5 for SATA (AHCI) ports. Intel RSTe RAID 0/1/10 is included for SAS (SCU) ports on C606-based boards. About Turbo Boost 2.0 Turbo Boost 1.0 dynamically increased the frequency of active cores based on temperature, current, power consumption, and operating system states. It did not, however, exceed programmed power limits. Turbo Boost 2.0 allows the processor to exceed its power ceiling in a burst, until it reaches its thermal limit, at which point it reduces power to conform to those same programmed limits. This example is based on the Intel Xeon processor E5-2620: 6 cores, 2.00 GHz, with a Turbo Boost specification of 3 / 3 / 4 / 4 / 5 / 5. When thermal headroom exists or a core is idle, Turbo Boost increases the base frequency of the cores. The first number corresponds to the boost potential of 3 bins per core when all six cores are active. The second number refers to the boost potential of 3 bins per core when five cores are active. The third number refers the boost potential of 4 bins per core when four cores are active. The fourth number refers to the boost potential of 4 bins per core when three cores are active. The fifth number refers to the boost potential of 5 bins per core when two cores are active. The sixth number refers to the boost potential of 5 bins when one core is active.

Interpreting the Turbo Boost Specification Memory Overview Platform capability: Up to 4 channels per CPU Up to 3 s per channel Memory types supported: U, R, LR Single-rank (SR), dual-rank (DR), or Quad-Rank (QR) DDR3 up to 1600 MT/s Memory Restrictions 32GB support dependent upon availability. Memory speed is affected by 3 major factors: The memory controller in the CPU (see page 4, "Max Mem Speed") How many s are populated per channel (see pages 10, 11, and 12) If s slots are populated with memory of different speeds, all channels in the system will run at the fastest common frequency.

Memory Population Guidelines Mainboards with 1 per Channel (8 Slots) Bank A 1.5V s 1.35V s U 1 or 2 Rank 1600 1333 R 1 or 2 Rank 1600 1333 4 Rank 1066 800 LR 4 Rank 1333 1333

Memory Population Guidelines Mainboards with 2 s per Channel (16 Slots) Bank A Bank B 1.5V s 1.35V s U 1 or 2 Rank Empty 1333 1333 1 or 2 Rank 1 or 2 Rank 1333 1066 1 or 2 Rank 1 or 2 Rank or Empty 1600 1333 R 4 Rank Empty 1066 800 4 Rank 4 Rank or Empty 800 800 LR 4 Rank 4 Rank or Empty 1333 1066

Memory Population Guidelines Mainboards with 3 s per Channel (24 Slots) Bank A Bank B Bank C 1.5V s 1.35V s U 1 or 2 Rank 1 or 2 Rank or Empty n/a 1333 1066 1 or 2 Rank 1 or 2 Rank or Empty Empty 1600 1333 1 or 2 Rank 1 or 2 Rank 1 or 2 Rank 1066 n/a R 4 Rank Empty Empty 1066 800 4 Rank 4 Rank Empty 800 800 4 Rank 4 Rank 4 Rank n/a n/a LR 4 Rank 4 Rank or Empty Empty 1333 1066 4 Rank 4 Rank 4 Rank 1066 1066

Rackmount Servers 1U Servers EM1740R I1780R Rackform iserv R352.v3 2U Servers EM2780R High-Density 1U and 2U Twins ET1740RX2 ET2760RX2 ET2760RX4 Blade Nodes: 3U Servers EM3780R EM2760RX4 4U Servers EM4780R EM4785R

Contact Ironsystems Sales For answers regarding processor selection, memory matching, or other questions you may have, contact Sales@ironsystems.com Toll Free: 800-943-IRON(4766) For more infornation visit: http://www.ironsystems.com Iron Systems, Inc. 540 Dado Street, San Jose, CA 95131, USA Phone: 1-408-943-8000 (Local) 1-800-921-IRON Fax: 1-408-943-8222 Email: info@ironsystems.com Website: http//www.ironsystems.com