Corrosion protection linings. Issue 1



Similar documents
HYLINER AKS HDPE LINING

SikaProof A Technology

Plastics Engineering SYSTEM BEKAPLAST. Mechanically anchored thermoplastic lining for extreme conditions

Access chambers and maintenance shafts. Issue 1

WATERPROOFING SikaProof -A TECHNOLOGY

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

EPTEC CAPABILITY STATEMENT

Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Module 3: Sewer Material Lecture 3: Sewer Material

Module 3 : Sewer Material. Lecture 3 : Sewer Material

Pipes and Fittings for Gravity Sewer Mains. SewerMAX

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Formwork Direct International Ltd Phone No +44 (0151) Fax no +44 (0151)

SPR PE Steel Reinforced Liner

Royal Seal Gasketed Sewer Pipe

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

PAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL

Concrete Pipes. Concrete Pipes

COPYRIGHT. Dincel Construction System Pty Ltd

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

725-R-599 PIPE LINING. (Revised ) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE

Fosroc Proofex Engage

Section 2100-Trenching and Tunneling

TG 105 ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS TECHNICAL GUIDELINE. Manager Asset Management SOUTH AUSTRALIAN WATER CORPORATION

DIVISION 4300 STORM DRAINAGE

Appendix A: Acceptable pipe and fitting materials

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

WATERPROOFING SIKAPLAN MEMBRANE SYSTEMS FOR BASEMENTS TECHNOLOGY & CONCEPTS

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

(52) In6 Publication CCM2 May 2000 ADVANCED DRAINAGE SYSTEM CATCHPITS, CHAMBERS & MANHOLES RIDGIDRAIN ENGINEERING EXCELLENCE

Membrane for tunnels and underground construction

Concrete Waterproofing Systems. Integral Protection.

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

The most advanced Undersink Sullage System with inbuilt controls and alarms.

Jacking pipes. Issue 1

THORO. Waterproofing Systems

Austin San Antonio Beaumont

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Reticulation sewers in basements Technical guidelines

INDUSTRY STANDARD FOR REINFORCED CONCRETE PIPES WITH FLEXIBLE THERMOPLASTIC LININGS WSA

How To Test A Wrap N Drain X Dampproofing System

Waterproofing construction Joints

WATERPROOFING OF WET ROOMS

Chapter 3 Pre-Installation, Foundations and Piers

ElastoFlake & ElastoTec

constructive solutions Fosroc total waterproofing protection of below-ground structures

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

PRELIMINARY BROCHURE. Uddeholm Corrax

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

DENSO WATERPROOFING SYSTEMS

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Secondary Containment: Regulations & BMPs. Beth Powell Vice-President and General Manager New Pig Energy bethp@newpigenergy.com

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

ABOUT US ABOUT PE THE DEFINITION OF POLYETHYLENE

STRONG FLEXIBLE. HyperPure PURE

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

SECTION STORM DRAINAGE SYSTEM

Pipeline Replacement using Relining

FY08 SEWER POINT REPAIRS BID TABULATION

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Waterproofing below-ground with Proofex Engage

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Precast concrete solutions. Issue 4

Gas Membrane and Waterproof Tanking Systems

Technical Manual - Section 1 Introduction to Lytag lightweight aggregate

Since HMT Inc. 24 Waterway Avenue, Suite 400 The Woodlands, Texas Ph: Fax:

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Composite Panel Firewall Systems

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

Repair or Replacement - Band-Aids vs. Surgery

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE

Session: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam

Town House Center Highway North Huntingdon, PA 15642

SEWERS FOR ADOPTION 6 PIPE MATERIALS TABLE AND CONDITIONS OF USE VERSION 4 March 09

Ridgistorm-XL - the latest innovative

Wastewater Capital Projects Management Standard Construction Specification

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

Steel-Reinforced Concrete Drainage Pipe STORMWATER

The Pipelines Regulations, 2000

City of Lincoln, Nebraska STEVENS CREEK BASIN TRUNK SEWER TECHNICAL MEMORANDUM NO. 5 PIPE MATERIAL SELECTION TABLE OF CONTENTS

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

TRADE PRODUCT GUIDE MAKE THE RITE CONNECTION Page a

1.2 Advantages and Types of Prestressing

Transcription:

Corrosion protection linings Issue 1

Introduction While Humes sewerage pipes and products are designed to serve over 100 years in accordance with AS/NZS 4058, we offer corrosion protection linings to increase durability and reduce the risk of corrosion. Above: HDPE lining sheets with the anchor side visible Lining systems are able to bridge any discontinuities in the pipe/structure wall, which is a distinct advantage over coating systems that depend on the integrity of the surface for functionality. Humes supplies two thermoplastic linings to reduce the risk of sulphide attack/corrosion in sewage applications: HDPE lining High density polyethylene (HDPE) lining suits both precast and in-situ applications. Firmly anchored to the pipe, the lining forms a superior protective layer able substantially withstand both abrasion and harsh chemical environments. This material is available in a variety of colours, including pale colours which allow easy visual inspection. HDPE lining is available in 2 mm to 5 mm thicknesses in sheets up to 3 m wide. Plastiline lining This chemically inert plasticised PVC material is mechanically fixed to the pipe s internal surface during the manufacturing process and gives superior protection against chemical attack inside the pipe. Plastiline lining has been in use across Australia for over 45 years, is easy to weld and is suitable for both precast and in-situ applications. 1 Corrosion protection linings

HDPE lining Applications Corrosion protection linings Humes advanced manufacturing capability enables HDPE lining to be incorporated into our full range of precast products. Features HDPE lining is equally suitable for in-situ installations. Sheets can be glued or mechanically fixed to formwork, and the anchors themselves can provide excellent fixing points. Lining the surface area of slabs, and retrofitting of walls and complex shapes can be achieved with the use of high-strength grout bedding or injection. HDPE lining has been used in a broad range of applications including segmental sewer tunnels, detention basins, piers, pile caps and bridge abutments. available in white and other light colours suitable for potable water systems suitable for both precast and in-situ applications quality assured installation by trained industry professionals anchors are integrally formed with the sheet sheets are up to 3 m wide sheets are 2 mm to 5 mm thick anchors are 12 mm long 1230 knobs per square metre manufactured from HDPE (PP or LLDPE also available) Left: In-situ application for a sewer pump station Right: In-situ application in a sewer tunnel Corrosion protection linings 2

Jointing Right: Thermal welding of HDPE lining A continuous lining system is created through the use of various methods of thermal welding, performed by trained and certified industry professionals. Overlapped extrusion welds are recommended for site work. As a minimum all site welds must be spark or vacuum box tested. Extrusion butted, double wedge and electronic butt welds are used predominately in factory assembly conditions. Figure 1 HDPE weld types Extrusion weld - overlapped Extrusion weld - butted Double wedge weld Electronic butt weld 3 Corrosion protection linings

Corrosion protection linings Plastiline lining Features Above: Concrete pipes with Plastiline lining Applications The prime function of Plastiline lining is the protection of concrete against hydrogen sulfide (H 2 S) attack. It is also effective against a wide range of acids, alkalis and aggressive salt solutions. Plastiline lining offers superior protection and is suitable for applications which include sewers, treatment works, industrial waste lines, storage tanks - in fact, any concrete structure where aggressive agents are encountered. suitable for both precast and in-situ applications quality assured installation by trained industry professionals keys are integrally formed with the sheet sheets are 1240 mm wide sheets are 1.5 mm thick keys are 10 mm long used in Australia for over 45 years Jointing Jointing and sealing together sections of Plastiline lining is readily achieved by a trained operator using a heat fusing process. The resultant weld is equivalent in protection to that of the parent sheet. Welding strips and other accessories are readily available. Corrosion protection linings 4

National sales 1300 361 601 humes.com.au info@humes.com.au A Division of Holcim Australia This publication supersedes all previous literature on this subject. As the specifications and details contained in this publication may change please check with Humes Customer Service for confirmation of current issue. This publication provided general information only and is no substitute for professional engineering advice. No representations or warranty is made regarding the accuracy, completeness or relevance of the information provided. Users must make their own determination as to the suitability of this information and any Humes product for their specific circumstances. Humes accepts no liability for any loss or damage resulting from any reliance on the information provided in this publication. Humes is a registered business name and registered trademark of Holcim (Australia) Pty Ltd (Holcim). Strength. Performance. Passion. is a trademark of Holcim. Plastiline is a registered trademark of Holcim (Australia) Pty Ltd. May 2013 Holcim (Australia) Pty Ltd ABN 87 099 732 297. All rights reserved. This guide or any part of it may not be reproduced without prior written consent of Holcim.