Instruction Sheet PDS SERIES. Single Circuit Power Sequencer FRONT VIEW POWER ON I. DOWN 120V 12A 60Hz REAR VIEW. (PDS-615R Shown)

Similar documents
Operation Instructions PowerCool Series

FERRORESONANT BATTERY CHARGERS

Read this document before using this product.

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)

Advantium 2 Plus Alarm

Instruction Sheet COOL SERIES DUCT COOL

v. 02.november.2010 owner s manual

Leak Detection System

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

DC50Xu. Digital Transport Adapter. Quick Start Guide. BRINGING TECHNOLOGY HOME

Automatic Phone-Out Home Monitoring Systems

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Altec Lansing Computer Speaker System

igroove SXT Owner's Manual

ATS Overhead Table Shelf System INSTRUCTION MANUAL

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

OPERATING MANUAL PUBLIC ADDRESS POWER AMPLIFIER PA-9336

Model SPDT Relays

INSTRUCTION MANUAL MODEL PCD-88

Backup Scanner Module

Water Leak Detection System

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

Direct AC Wiring Option Installation Guide

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Owner s Manual Phoenix CAM

Ready. Set. Go. Pick a spot and plug it in.

Replace the Pump Tube Classic

For Models #6-5001, #6-7501, # & #10-12K1

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Sun Enterprise Optional Power Sequencer Installation Guide

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

SMS SERIES MIXER SYSTEM INSTALLATION AND MAINTENANCE MANUAL

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

User guide Conference phone Konftel 100

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

About the HotWire Slot Standalone Shelf

USER S GUIDE V: BC118 Portable Boombox. For the most up-to-date version of this User s Guide, go to

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

Comfort Control Relay Panel (CCRP)

Evolution Digital HD Set-Top Box Important Safety Instructions

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

Regulatory Compliance Statement

esata External Storage


S-8, S-10 AND S-12 POWERED SUBWOOFER. Owner s Manual

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Owner s Manual Phoenix 230V 50Hz Axial Air Mover

IR Repeater. Operation Manual P8620

Wireless Phone Jack System

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

BroadBand PowerShield. User Manual

Intercom and Music System Bluetooth Player Operation & User s Guide. DMC System Master with DMCBT Bluetooth Player

i410/i1010 AC/DC Current Clamp

Model SRMD Setra Remote Monitoring Display

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

PagePac PAGEPAL V

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

Nest Learning Thermostat Installation Guide. Installation step-by-step

12-Volt 10-Amp Regulated Power Supply

Alarm Clock USER GUIDE

Caller-ID on your TV!

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Touch Tone Controller. Model TR16A. Owner s Manual

Read And Save These Instructions

Installation & Operation Instructions

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

User Manual (English)

M2M Cellular Signal Amplifier

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

Operation Manual. Multi Channel Power Amplifier DPA-430L

Installation. Basic Rack Power Distribution Unit AP9559

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

24.2L M.A.N. V12 Engine Module

AMBR AMATIS Border Router

PK5500 v1.1 Installation Instructions

Laptop Power Adapter for home/office User Manual

BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS

Powerware Relay-Serial Card User s Guide

900 MHz Lightweight Wireless Stereo Headphones

PORTABLE ALARM CLOCK. Dual Alarm. FM Radio. Wake-up Sounds. USB Phone Charger G-1CR

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

Mini Power Bank and Charger

MARK VISION. A Word from Marco De Virgiliis

Installation and Operation Guide PD4600 Series Converter Replacement

767 Diagnostic System

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

The Bouncer Bluetooth Stereo Speaker

PSC POWER STAR LiFE TM

User and Installation Guide

TWO/FIFTY/TWO STEREO POWER AMPLIFIER

EKOS Cart. Instructions for Use

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

GSM-EXT Cable Assembly Installation Guide

Transcription:

Instruction Sheet PDS SERIES Single Circuit Power Sequencer FRONT VIEW POWER ON I SEQUENCE SYSTEM OFF 120V-12A-60Hz UNSWITCHED STATUS REMOTE 5 6 CLOSED - All channels on OPEN - All channels off UP COM DOWN 120V 12A 60Hz REAR VIEW ( Shown) THANK YOU Thank you for purchasing the PDS Series Single Circuit Power Sequencer. Please read these instructions thoroughly before installing this product. PRODUCT FEATURES - Six-step sequencing to six rear outlets - Monitor sequencing with the front panel LED indicators - Up to three PDS units can be daisy chained together to act as a single, 18 step unit I-2221 Rev H

IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS! CONSERVER CES INSTRUCTIONS! Contains switched receptacle(s). To reduce risk of shock, disconnect the device from the power source before servicing any connected equipment Contient de(s) receptacle(s) muté(s). Pour réduire les risques d'électrocution, débranchez l'appareil de la source d'alimentation avant l'entretien de tout équipement connecté Do not overload the wall outlet where this device is being connected. Do not overload this device. Ensure the total load to this device does not exceed that which is listed in the specifications section of this manual Ne surchargez pas le réceptacle de mur ou le circuit qui fournit l'énergie à ce appareil. Ne pas surcharger cette appareil. S'assurer que la charge totale à cet appareil ne dépasse pas celle qui est répertoriée dans la section des spécifictions de ce manuel Ensure this device is connected to a properly grounded AC power source. Ensure the device is plugged into a source providing the required 120V. Do not use a plug adapter that defeats the ground pin of the AC plug Assurez-vous cet appareil est connecté à une source d'alimentation C/A avec mise à la terre. Assurez-vous cet appareil est branché sur une source d alimentation fournissant les nécessaires 120V. Ne pas utiliser un adaptateur qui contrecarre la broche de terre de la prise du cordon d alimentation DANGER HAZARDOUS VOLTAGE/DANGER HAUTE TENSION The lightning flash with the arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. L'éclair avec le symbole de flèche dans un triangle équilatéral est destiné à alerter l'utilisateur de la présence d'une tension dangereuse non isolée dans l'enceinte du produit qui peut être d'une ampleur suffisante pour constituer un risque de choc électrique pour les personnes. CAUTION/ATTENTION The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature acpanying the appliance. Le point d'exclamation dans un triangle équilatéral est destiné à alerter l'utilisateur de la présence d'importants instructions d opération et de maintenance (entretien) dans la documentation acpagnant l'appareil. There are no user-serviceable ponents within this device. Removal of the cover from this device may present a shock hazard, and void the warranty Il n'ya pas de posants réparables par l'utilisateur au sein de cet appareil. Retrait de la couverture de cet appareil peut présenter un danger d'électrocution et annuler la garantie To be used indoors in a dry location only Pour être utilisé en intérieur dans un endroit sec seulement Do not operate with a damaged cord or plug Ne pas faire fonctionner avec un cordon ou une prise endommagée Clean only with dry cloth Nettoyer avec un chiffon sec seulement IMPORTANT NOTES NOTE: The MAINS plug or an appliance coler is used as the disconnect device, the disconnect device shall remain readily operable. The socket-outlet shall be installed near the equipment and shall be easily accessible. REGULATORY COMPLIANCE The product meets the requirements of the following standards: UL 60065, 7th Ed, CAN/CSA-C22.2 No. 60065, R2012 UL/CSA 60950-1, 2nd Ed UL 1419, 3rd Ed Page 2

CONNECTIONS, CONTROLS AND INDICATORS FRONT VIEW B ON SEQUENCE SYSTEM OFF E C A POWER I REAR VIEW 120V-12A-60Hz UNSWITCHED CLOSED - All channels on OPEN - All channels off STATUS G F D REMOTE UP COM DOWN 5 6 DESCRIPTION The PDS single circuit series are power s that provide sequenced AC power to 6 individual outlets located on the rear of the unit, and feature sequence interval and delay start times. The maximum cumulative load is 12 amps at 120 volts for the, and 16 amps at 120 volts for the PDS-620R. 120V 12A 60Hz A B C D E F G MASTER SWITCH: The red Master Switch located on the front panel provides power to the control circuitry and also serves as the main circuit breaker. This switch will illuminate when in the on position and AC power is present. SYSTEM SWITCH: This momentary switch initiates system power and power. When the Master Switch is on, depressing the top of this switch initiates the power sequence, with power to each outlet indicated by the corresponding Status indicator light. The rear outlets will activate in order beginning with outlet #1 and ending with outlet #6, at a user definable interval (See DIP Switch Settings chart). Depressing the bottom of the System Switch initiates the power sequence in reverse order, beginning with outlet #6 and ending with outlet #1. Turning the Master Switch off removes power from all outlets simultaneously, including the uncontrolled outlet ( G ) on the rear of the unit. DELAY ADJUST DIP SWITCH: These switches allow for more plex system design by providing user control over two important functions; delay start time (the time from when the sequence is initiated to the time the first outlet receives power), and sequence interval time (how much time elapses between individual outlets receiving power). These DIP switches and the functions they control allow to three s to be "chained" together (providing to 18 channels) REMOTE TERMINAL BLOCK: This three position terminal block on the rear of the unit is parallel to the System Power Up/Down Switch on the front panel. An installer provided SPDT CENTER OFF (single-pole, double-throw, center position off) momentary switch can be connected for remote initiation of system sequencing. An installer provided "key" switch can also be used where extra security is required. Up to three s can be controlled with one remote switch, or by the front panel system switch of the any, by wiring all Remote Terminal Blocks in parallel. (see wiring diagram) GREEN POWER INDICATOR: This indicator lights when the Master Power Switch is on. When the Delay Start feature is selected via the Delay Adjust DIP Switches, this light will blink to indicate that the unit has received a mand to initiate a sequence or. This light will blink for the duration of the selected delay start time. (from time sequence is initiated to the time the first outlet actually receives power). STATUS INDICATION TERMINAL BLOCK: Dry relay contact closure closed when channels 1 through 6 are on. Contact open when channels 1 through 6 are off. 120V/12A CONVENIENCE OUTLET (NOT CONTROLLED): On when "Master Switch" is on. Page 3

POWER - 12 Amp circuit - 9' Power cord (14/3) - Standard NEMA 5-15 plug PDS-620R - 16 Amp circuit - 9' Power cord (12/3) - Standard NEMA 5-20 plug OUTPUT - 7 Rear outputs (1 uncontrolled) - 12 Amps total load (max ) - 16 Amps total load (max PDS-620R) PROGRAMMING - Sequence delay start and interval between outlets timing functions controlled via front mounted dip switch. DIMENSIONS - 19" Wide - 1.75" High (1 space) - 8.75" Deep CONSTRUCTION - 18 Gauge steel - Black powder coat finish INTERCONNECTION - Rear remote control terminal block provides remote system power /. Multiple units may be chained together via simple parallel control wiring. - Rear status terminal block, indicates sequence plete. (Relay contact closure) PROTECTION - 15 () or 20 (PDS-620R) Amp circuit breaker located on front panel. (master switch) #1 #2 SEQUENCE UP/DOWN START DELAY If 2 or 3 s are to be used ("chained") together: #1 #2 #3 first on last off second on second off last on first off DIP SWITCH SETTINGS: DELAY BETWEEN SEQUENCES.75 second interval between 1.5 second interval between 2.25 second interval between #3 optional Installer provided remote Switch 7 second interval between 1) Wire all rear terminal blocks in parallel, for multiple sequence operation. 2) Front system power / switch is wired in parallel with rear remote terminal block. When wired together as shown, pressing front System Power UP/DOWN switch on ANY will initiate system sequencing. 3) If remote power UP/DOWN is required, wire dry contacts in parallel. (single pole, double throw, center off, momentary switch) 4) Initiating system sequencing remotely: Sequencing can be initiated by either momentary dry contact or maintained dry contact. Use of a maintained dry contact for system power will reinitiate sequence after power is restored from a power outage. When using maintained (not momentary) dry contact for remotely controlling system sequencing, the front System Power UP/DOWN switches will be over-ridden. NOTE: A flashing power (green) LED indicates that the system sequencing has begun. Page 4

WARRANTY Middle Atlantic Products (the "Company") warrants the PDS Power Series Single Circuit Power Sequencer to be free from defects in material or workmanship under normal use and conditions for a period of (3) years from the date of shipment by the pany. The Company's entire liability to the purchaser, and the purchaser's (or any other party's) sole and exclusive remedy, under this warranty shall be limited, at the Company's option, to either (a) return of and refund of the price paid for, or (b) repair or replacement at the Company's factory of the products purchased, or any part or parts thereof, which the Company has determined to be defective after inspection thereof at the Company's factory. This warranty does not cover damage due to acts of God, accident, misuse, abuse or negligence by parties other than the Company, or any modification or alteration of the products. In addition, this warranty does not cover damage due to improper handling, assembly, installation or maintenance. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF THE PRODUCTS PURCHASED, EVEN IF THE COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE COMPANY'S LIABILITY TO THE PURCHASER (OR ANY OTHER PARTY) HEREUNDER, IF ANY, SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS PAID TO THE COMPANY. Corporate Headquarters Corporate Voice 973-839-1011 - Fax 973-839-1976 / International Voice +1 973-839-8821 - Fax +1 973-839-4982 middleatlantic. - info@middleatlantic. Middle Atlantic Canada Voice 613-836-2501 - Fax 613-836-2690 / middleatlantic.ca - customerservicecanada@middleatlantic.ca Factory Distribution USA: NJ - CA - IL Canada: ON - BC At Middle Atlantic Products we are always listening. Your ments are wele. Middle Atlantic Products is an ISO 9001 and ISO 14001 Registered Company. Page 5