Copyright Puradigm, LLC. 2012. HVAC Owner s Manual



Similar documents
WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

+by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System

REME HALO by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Installation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:

Tablet 30W Tablet 92W

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

IR Repeater. Operation Manual P8620

Advantium 2 Plus Alarm

Installation Instructions HighRock 4x4 TM

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

ChargePoint Home. Installation Guide. ATTENTION: Please read thoroughly and keep this installation guide.

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Expanding a 40-Type Cabinet

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

Installation Instructions

Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions

ECM-D70T / ECM-D70T1.5

Anthro Tablet Charging Cabinets

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Mini-led spotlight with magnetic base

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

PATHWAY Classic Series with Handrails Portable Wheelchair Ramp INSTRUCTIONS FOR USE 6428 REV A

Retractable Screen. Replacement Screen Instructions

Remote Alarm Monitoring System

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

INSTALLATION INSTRUCTIONS

Digital Fingerprint safe

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Models: RK-1T2PT RK-2T1PT RK-3T RK-6T RK-9T RK-3TR RK-4PT RK-T2B RK-T2SB

Global Water Instrumentation, Inc.

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

24.2L M.A.N. V12 Engine Module

Nest Learning Thermostat Installation Guide. Installation step-by-step

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Destiny Shower Enclosure Installation Instructions

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

Installation Instructions

Operation Manual. Made in the U.S.A. For questions or concerns with this unit, please call DO NOT return this antenna to your dealer.

INSTALLATION INSTRUCTIONS

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Alarm Clock USER GUIDE

Crestron TMK-6L & WMKT-6L Trim Ring Mount Kits Installation Guide

HotLok Pass Through Blanking Panel

VF400. User Instructions

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Vehicle Restraint Installation Manual

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

BroadBand PowerShield. User Manual

GSD 22 Sounder Module. installation instructions

Electric Mini Tank Water Heaters WM-2.5 & WM-4.0

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

Model 5101, 5102, 5103SL, 5110, 5111, 5115 STEEL SECURITY SAFE. Read this manual carefully and never store it inside the safe!

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Single Station Remote Alarm

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

P O W E R S U P P L Y M A N U A L

Wireless Indoor/ Outdoor Thermometer

2-Way Wireless Indoor Siren Installation Guide

INSTALLATION INSTRUCTIONS PART NUMBER:

How To Install A Power Supply (Uplast) With A Battery Pack

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

ROTOR LOADER OWNER S MANUAL


INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

ROUTER TABLE INSERT ASSEMBLY AND OPERATING INSTRUCTIONS

Acrylic Walls Installation Instructions

Triple Expansion Chassis

STC 3S A Series Solenoid Valves

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

INSTALLER S & OWNER S MANUAL

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER DS BMW 335i 3.0L

Installation and Operation Manual

Customer Support

Vari-Mix Aliquot Mixer Type 48700

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

20 GALLON WET DRY VACUUM

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Lionel WWII Airplane Pylon Owner s Manual /02

INSTALLATION AND OPERATION MANUAL

Technical support is also available by or by phone: (North America) (International)

Transcription:

Copyright Puradigm, LLC. 2012 HVAC Owner s Manual

Notes 2 Copyright Puradigm, LLC. 2012 15

Notes Congratulations on your purchase of a Puradigm Air HVAC air purification system. This unit is designed to be installed into an existing HVAC system, and used as a virtually maintenance free air purification technology. Please read and follow all service procedures outlined in this manual. Please record the name and phone number of your Dealer Name Phone # Please record the serial number of your Puradigm Air HVAC. Serial # CONTENTS Product Contents.... 4 Installation Hardware... 4 Replacement Parts.... 4 Specifications.... 5 About Puradigm Air HVAC... 5 Recommended Installation Tools.... 6 Installation Requirements.... 6 Metal Puradigm Air HVAC Installation.... 7 Fiberglass Puradigm Air HVAC Installation... 9 Maintenance/UV Lamp Indicator... 11 Changing the PCO Cell.... 12 Warranty... 13 14 Copyright Puradigm, LLC. 2012 3

PRODUCT CONTENTS LIMITED WARRANTY INFORMATION Your Puradigm Air HVAC unit consists of two(2) seperate products. The housing, which protrudes from the HVAC duct when installed and the cell which extends into the ductwork. Mounting Plate Your Puradigm Air HVAC Housing (Product) is warranted to be free from all defects in material and workmanship in normal household use for a period of 3 years from date of purchase.* Your Puradigm Air HVAC Cell, including the bulb, is warranted to be free from all defects in material and workmanship in normal household use for a period of 2 years from date of purchase. The warranty is granted only to the original purchaser. The warranty is subject to the following provisions: Replaceable Cell (includes UV Lamp) Any damages or malfunctions caused by negligence, abuse, or use not in accordance with the Product Owner s Manual are not covered by this warranty. Likewise, any defects or damages caused by unauthorized service or the use of other than Genuine Puradigm, LLC. Parts are not covered. Puradigm, LLC. will, at its option, repair or replace a defective Product or part(s) for the Product that is/are covered by this warranty. As a matter of warranty policy, Puradigm, LLC. will not refund the customer s purchase price. UV Bulb indicator OBTAINING WARRANTY SERVICE Safety Switch Power Adapter To obtain warranty service you must return the defective product along with proof of purchase to the Puradigm, LLC. Authorized Service Center. All shipping costs submitted under this Warranty shall be borne by purchaser. Unless this Warranty is expressly renewed or extended by Puradigm, LLC., any repaired or replaced part of unit shall be warranted to the original purchaser only for the length of the unexpired portion of the original warranty. For the location of the nearest Puradigm, LLC. Authorized Service Center or for other service information, please visit us online at: INSTALLATION HARDWARE www.puradigm.com/service Before any product is sent for service, the customer should contact the Puradigm, LLC. Authorized Service Center to obtain a Return Merchandise Authorization (RMA) Number. This RMA Number should be clearly written on the box before shipping. All components/parts including the remote (if applicable), manuals, and original packaging should be included in the return if available. (8) #8 -.75 1/4 Self-tapping screws REPLACEMENT PARTS (4) #6-32x2 inch Threaded bolts (4) #8-32 Hex nuts (4) #6-32 Toggle bolt wall hangers FURTHER LIMITATIONS AND EXCLUSIONS ARE AS FOLLOWS Any warranty that may be implied in connection with your purchase or use of the Product, including any warranty of merchantability or any warranty for Fitness For A Particular Purpose is limited to the duration of this warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Your relief for the breach of this warranty is limited to the relief expressly provided above. In no event shall Puradigm, LLC. be liable for any consequential or incidental damages you may incur in connection with your purchase or use of the Product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Mounting Plate This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Cell (includes UV Lamp) REGISTRATION Please register your Product within 10 days of purchase by visiting www.puradigm.com/warranty, or fill out and return the enclosed warranty registration card. Registering your new Puradigm, LLC. product entitles you to the most up-to-date Puradigm, LLC. warranty and promotion information. Base Unit 4 Copyright Puradigm, LLC. 2012 13

CHANGING THE PCO CELL WARNING: UV Light in operation. Disconnect unit from power supply before servicing. Failure to follow warnings may result in severe eye damage 1 2 ABOUT Puradigm Air HVAC Puradigm Air HVAC is a new generation HVAC Air purification system. Designed to work with existing purification technology to reduce odors, smoke, and a broad spectrum of indoor air contatminants. Puradigm Air HVAC is easily mounted into air conditioning and heating system air ducts where many problems can start. When the HVAC system is in operation, Puradigm Air HVAC creates an Advanced Oxidation Process consisting of hydroperoxides, superoxide ions, and safe low level ozone-all friendly oxidizers that revert back to oxygen and hydrogen after the oxidation of a pollutant. 1. Unplug unit if unit is hard wired, be sure the power to the unit is off. 2. Remove the 4 mounting nuts. Used in conjunction with other current purification systems, Puradigm Air HVAC can boost effectiveness and help distribute their benefits throughout your home. 3 4 CELL SPECIFICATIONS 3. Remove the unit from the mounting plate. 5 4. Remove the 2 screws holding the PCO Cell. 6 The Puradigm Air HVAC Probe can be ordered with 5, 9, or 14 cells. The cell length you need will depend on the cubic footage the air handler covers with consideration for the amount of space available inside the plenum. Normal Output High Output No Ozone 5 (118mm) 8 x8 x7 ; 2.6 lbs Including Housing DW750-O3 Uses 13.3 Watts.11 Amps Required Not Available N/A Not Available N/A 5. Separate the used PCO Cell from the base unit and dispose of properly. 6. Plug the new PCO Cell into the base unit. 9 (212mm) 8 x8 x11 ; 2.8 lbs Including Housing DW2000-O3 Uses 13.3 Watts.11 Amps Required Not Available N/A DW2000-NO3 Uses 13.3 Watts.11 Amps Required 7 8 14 (357mm) 8 x8 x16.75 ; 3 lbs Including Housing DW5000-O3 Uses 19.2 Watts.16 Amps Required DW5000-O3HO Uses 32.4 Watts.27 Amps Required DW5000-NO3 Uses 19.2 Watts.16 Amps Required 7. Secure with 2 screws. 8. Insert the unit into the mounting plate.! WARNING! - UV light in operation. Disconnect unit from power supply before servicing. Failure to follow warnings may result in severe eye damage. 9 10 To reduce the risk of electric shock, this equipment may have a grounding type plug that has a third (grounding) pin. This plug will only fit into a grounding type power outlet. If the plug does not fit into the outlet, contact qualified personnel to install the proper outlet. Do not alter the plug in any way. 9. Secure units with 4 nuts. 10. Reconnect 12 DO NOT OVER-TIGHTEN. power supply. Copyright Puradigm, LLC. 2012 5

RECOMMENDED INSTALLATION TOOLS MAINTENANCE / UV LAMP INDICATOR Your Puradigm Air HVAC unit requires no periodic maintenance beyond normal replacement of the PCO cell every 3 years. The UV lamp operation indicator on the face of the unit will glow when the UV lamp is in use. If the indicator does not glow and the unit has power, the PCO cell should be replaced. 3 1/2 Bi-Metal Hole Saw (reccommended) Drill/Power Driver Phillips Screwdriver 3/8 Drill Bit (if installing into fiberglass ducting with toggle bolts) YOU MAY ALSO NEED Note: For optimal performance, we recommend the replacement of the PCO cell every 3 years, even if the UV lamp appears to be operating normally. 11/32 Open-End Wrench 9/16 Nut Driver Bit Utility Knife Tin Snips (for metal ductwork) UV lamp operation indicator INSTALLATION REQUIREMENTS 1. MCI unit should be installed after the air handler in the HVAC system in the supply plenum.* 2. The ductwork around the installation area should be clean and dry to ensure proper adhesion of the gasket materials and any tape used. 3. An approximate 3.5 (8.89 cm) opening will need to be cut into the existing duct work to install the unit properly. *For additional protection of the HVAC system, we recommend a standard Puradigm Air probe in the return plenum. ELECTRICAL REQUIREMENTS MCI Probe in Supply Plenum DISPOSAL OF THE PCO CELL Please do not throw a used PCO Cell in the garbage. The special germicidal UVX bulb used in the Puradigm Air HVAC contains a very small amount of mercury. Be sure to dispose of them properly or return your used PCO Cell to GreenTech Environmental for proper disposal. Send the used cell post paid to: The unit comes with a 100-240V power adaper providing flexibility of placement. The adapter comes with a 120V plug with ground. Locate the unit within 6 of a standard 120V grounded outlet. Long term use of an extension cord is not recommended due to safety considerations. See wattage/amperage requirements for appropriate probe on Page 5. Puradigm Air Probe in Return Plenum GreenTech Environmental 6124 Kingsport Hwy 36; Suite 1 Gray, TN 37615 6 Copyright Puradigm, LLC. 2012 11

FIBERGLASS DUCTWORK INSTALLATION (continued) METAL DUCTWORK INSTALLATION 5 6 1 2 Stud 5. Remove backing from mounting plate adhesive gasket. 7 6. Insert (4) 2 Threaded bolts into screw holes at corners of mounting plate. Attach (4) toggle bolt anchors to ends of threaded bolts. 8 1. Locate suitable area of duct for installation. 3 4 2. Cut away insulation to expose metal duct (if needed). 7. Insert (4) toggle bolts into 3/8 holes in duct. Be sure to toggle anchors open after inserting. 9 10 8. Center large opening in mounting plate over 3.5 opening in duct and press plate to duct. The adhesive gasket will hold the mounting plate into place. Tighten toggle bolts. (DO NOT OVERTIGHTEN) 3. Mark location for 3.5 opening using either the mounting plate or included template. ALTERNATIVE CUTTING METHOD 4. Cut hole in duct using 3.5 hole saw.. a b 9. Insert unit into opening. Be sure the air will pass through the PCO Cell honeycomb Matrix. (NOTE: Airflow Indicator located on Probe Base) 10. Secure the unit to the mounting plate with (4) #8-32 nuts. DO NOT OVER-TIGHTEN. a. Using template, mark 4 holes on duct. b. Drill holes where marked. c 11 11. Secure the adapter in place then plug unit into working power receptacle. c. Cut holes using tin snips. 10 Copyright Puradigm, LLC. 2012 7

METAL DUCTWORK INSTALLATION (continued) FIBERGLASS DUCTWORK INSTALLATION 5 6 1 2 5. Remove backing from mounting plate adhesive gasket. 6. Center openings and press mounting plate onto duct. The adhesive gasket will hold the mounting plate in place. 1. Locate suitable area of duct for installation. 2. Mark location for 3.5 opening using either the mounting plate or included template. Also mark the locations of 4 screw holes in corners (see template). 7 8 3 4 7. Secure the mounting plate using (8) #8 self-tapping screws. 8. Insert unit into opening. Be sure the air will pass through the PCO Cell honeycomb matrix. (NOTE: Airflow indicator is located on probe base) 3. Cut hole in duct using 3.5 hole saw. 4. Drill 4 holes (at corner screw locations) using a 3/8 drill bit. 9 10 ALTERNATIVE CUTTING METHOD a b 9. Secure the unit to the mounting plate with (4) #8-32 nuts. DO NOT OVER-TIGHTEN. 10. Secure the adapter in place then plug unit into working power receptacle. a. Using a template, mark 4 holes on duct. b. Draw a line between each corner mark. Hard wiring unit into HVAC system should be done by a licensed HVAC installer or electrical contractor only. c c. Cut between holes using a utitility knife. Continue with #4 (above). 8 Copyright Puradigm, LLC. 2012 9