The information contained in this document is intended for healthcare professionals only.



Similar documents
Accolade. System. Brochure. Achieving Perfect Balance. Cemented and Cementless Femoral Hip System

Acetabular Wedge Augment System

Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability

All Suture Anchor. with IntelliBraid Technology

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

DHCPL_RA EXT Page 1 of 6

MDMTM. Surgical Technique. Modular Dual Mobility TM Acetabular System. Orthopaedics

Total Hip Joint Replacement. A Patient s Guide

MDM. Surgical Technique. Modular Dual Mobility Acetabular System. Orthopaedics

Failure Mechanisms and Closed Reduction of a Constrained Tripolar Acetabular Liner

ACCOLADE II. Orthopaedics. Femoral Hip System. Surgical Technique

Why an Exactech Hip is Right for You

The information contained in this document is intended for healthcare professionals only.

Metasul LDH Large Diameter Head

Trident Acetabular System Hemispherical Surgical Protocol

Knotilus TM. Anchor Instability Repair. Technique Guide

Patient Labeling Information System Description

Clinical performance of endoprosthetic and total hip replacement systems

The information contained in this document is intended for healthcare professionals only.

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology

BONE PRESERVATION STEM

510(k) Summary of Safety and Effectiveness JUN Hip prosthesis

The information contained in this document is intended for healthcare professionals only.

Rejuvenate Total Hip System Surgical Protocol. Rejuvenate Modular Hip Stem Enhanced Stability 1 Proven Modularity 2 Intraoperative Flexibility

The Right Choice. Exeter. total hip system

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

FEMORAL NECK FRACTURE FOLLOWING TOTAL KNEE REPLACEMENT

Exeter X3 RimFit. Acetabular Cup Surgical Protocol

CuttingEdge Hip Instrumentation Femoral Surgical Technique for Primary Press-Fit and Cemented Hip Implants.

How To Fix A Radial Head Plate

Posterior Referencing. Surgical Technique

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal

Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique

Design surgeon list. Smith & Nephew thanks the following surgeons for their participation as part of the R3 system design team:

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique

OfficePACS Power. Digital Imaging for the Orthopaedic Workflow

Introduction to the Bertram Hip Spacer

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

Metal-on-Metal Hip Systems

IMPORTANT PRODUCT RECALL UPDATE RA EXT_2

Medical Device Alert. Device All metal-on-metal (MoM) hip replacements. Action by. CAS deadlines. Ref: MDA/2012/036 Issued: 25 June 2012 at 11:00

ReCap Product Rationale

*smith&nephew SLR-PLUS

Clinically Proven Fiber Metal Material. Power to choose advanced bearing technologies to match patient demands

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

Simplified surgery. Personalized performance.

Treatment of Femoral Neck Fractures: Unipolar Versus Bipolar Hemiarthroplasty

ACCORD Cable System. Surgical technique completed in conjunction with: Robert Barrack, MD St. Louis, Missouri. Paul Di Cesare, MD New York, New York

Answers to commonly asked questions from patients with metal-on-metal hip replacements / resurfacings. Contents


PINNACLE. Polyethylene Surgical Technique. Surgical Technique

Total Hip Replacement

Aesculap Orthopaedics Metha

Degenerative Spine Solutions

Structure and Function of the Hip

Robotic-Arm Assisted Surgery

PARTIES, VENUE AND JURISDICTION

DARCO MRS. Locked Plating System for Reconstructive Rearfoot Surgery

Hip Resurfacing 2011 ORIGINAL ARTICLE. James W. Pritchett MD. Introduction. Abstract

PRESENTATIONS/PAPERS INTERNATIONAL. RAISING STANDARDS IN JOINT ARTHROPLASTY Course Co-Chairman, The Great Debate - London, June 2013

TwinFix Cannulated Compression Screw

Ankle Arthritis Treatment in Worker Compensation The New Gold Standard ~ Total Ankle Replacement

High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System

Product overview and surgical technique

Restoration Modular. Revision Hip System Surgical Protocol

How To Use A Phoenix Retrograde Femoral Nail

Anterior Hip Replacement

Guidance for implant removal. Straumann Dental Implant System

MIS Direct Anterior Approach Surgical Protocol

PERIPROSTHETIC IMPLANTS

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

THE MEASUREMENT AND ANALYSIS OF AXIAL DEFORMITY AT THE KNEE

Disclosures. ! Consultant. ! Stryker. ! Smith and Nephew. Why Resurface? ! Save bone the day of surgery. ! No bone loss from stressshielding

Zimmer Trilogy IT Acetabular System

IN THE FEDERAL COURT OF AUSTRALIA (FCA) NEW SOUTH WALES REGISTRY - FEDERAL COURT OF AUSTRALIA

Hip Replacement Surgery Understanding the Risks

The information contained in this document is intended for healthcare professionals only.

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

Lentur Cable System. Surgical Technique

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

CeSpace Titanium / PEEK

on-metal Hips: Device Mechanics and Failure Modes

Directory chapter 04

TRIGEN INTERTAN Intertrochanteric Antegrade Nail Surgical Technique. Table of Contents

Cormet Hip Resurfacing System

Corporate Medical Policy Computer Assisted Surgical Navigational Orthopedic Procedures

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

UNITED STATES DISTRICT COURT DISTRICT OF MINNESOTA

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Imagine being an orthopedic surgeon and knowing that your patient s

Minimally Invasive Hip Replacement through the Direct Lateral Approach

P REPLACEMENT SURGERY

Hip Fracture in the Elderly: Partial or Total Arthroplasty?

ROGER E. MURKEN, MD. Curriculum Vitae. OrthoColorado Hospital W. 2 nd Place Lakewood, CO 80228

Transcription:

The information contained in this document is intended for healthcare professionals only.

UHR Universal Head Bipolar System

T he Stryker Orthopaedics UHR Universal Head is a leader among bipolar component designs. Released in 1979 and patented in 1980, the UHR Universal Head introduced two important design concepts to the field of orthopaedics. The first was dynamic valgus, a neutral alignment of the head during component loading that minimized wear on the locking mechanism. The second was the development of a one-piece, positive locking mechanism that provided enhanced security against component disassembly. Both of these developments revolutionized bipolar designs. Today, the UHR Universal Head retains all the same design features and benefits, and has established effectiveness with 20+ years of positive clinical use. 1,2,3,4,5,6 No other bipolar design can make that claim. Time proven design, easy-to-use instrumentation and versatility regarding femoral component selection make the UHR Universal Head the logical choice for your hemiarthroplasty requirements. Dynamic Valgus Alignment The concept of dynamic valgus alignment was introduced by Stryker Orthopaedics to provide increased head coverage during component loading. A two millimeter displacement toward the dome of the UHR Universal Head minimizes inner bearing articulation from occurring on the locking mechanism, thus sparing the mechanism from undue wear.* Optimal Fit A large array of component sizes allows precise patient matching for optimal patient fit. Outer diameters from 41 to 72 millimeters allow the surgeon to meet the unique challenges posed in revision. UHR Universal Heads are available in an arrayment of sizes, 41 to 72mm, allowing for precise patient matching. One-Piece Locking Mechanism Patented in 1980, this positive-locking design is easy to use, yet provides enhanced security against component disassembly. Laboratory tests show that the UHR Universal Head can be assembled by hand with less than four pounds of force, while disassembly requires more than 200 pounds of extraction force without the patented key.** UHR Universal Head requires less than 4 lbs. of hand pressure for assembly. UHR Key Bipolar without dynamic valgus alignment. UHR Universal Head with dynamic valgus alignment. Disassembly of UHR Universal Head using the patented key. 200 lbs. of force is required without its use. * Perez, Fausto - Technical assessment, explanation of dynamic valgus concept. ** R&D Internal Tech Report - RD830624, Technical Report - MT 00035, 00083

Beveled Lip The outer bevel decreases the likelihood of cup impingement on bony structures thereby increasing the likelihood for successful closed reduction (Figure 1). A B Figure 2. The UHR component features a reduced corner angle A and reduced step B. The probability of cup impingement occurring is a function of the natural geometry of the pelvis and the geometry of the bipolar prosthesis. The UHR Universal Head incorporates both a reduced step and a smoother corner angle (Figure 2). Together, these criteria provide a component that is less likely to lock onto the bony rim of the pelvis and less difficult to unlock should it become unavoidable. Clinical History Over 20 years of clinical use have made the Stryker Orthopaedics UHR Universal Head the premier bipolar system available today. 1,2,3,4,5,6 The UHR Universal Head shows superior results when compared to traditional endoprosthetic devices. 5,7,8 Compatibility The UHR Universal Head component will mate with any Stryker Orthopaedics femoral component and bearing head of comparable OD. An extensive implant matrix enables the surgeon to precisely match patient demand with the appropriate implant style.

UHT Universal Bipolar & Unipolar Instrument System Top Tray 1150-2338 Bipolar/Unipolar Trial, 38mm 1150-2340 Bipolar/Unipolar Trial, 40mm 1150-2341 Bipolar/Unipolar Trial, 41mm 1150-2342 Bipolar/Unipolar Trial, 42mm 1150-2343 Bipolar/Unipolar Trial, 43mm 1150-2344 Bipolar/Unipolar Trial, 44mm 1150-2345 Bipolar/Unipolar Trial, 45mm 1150-2346 Bipolar/Unipolar Trial, 46mm 1150-2347 Bipolar/Unipolar Trial, 47mm 1150-2348 Bipolar/Unipolar Trial, 48mm 1150-2349 Bipolar/Unipolar Trial, 49mm 1150-2350 Bipolar/Unipolar Trial, 50mm 1150-2351 Bipolar/Unipolar Trial, 51mm 1150-2352 Bipolar/Unipolar Trial, 52mm 1150-2353 Bipolar/Unipolar Trial, 53mm 1150-2354 Bipolar/Unipolar Trial, 54mm 1150-2355 Bipolar/Unipolar Trial, 55mm 1150-2356 Bipolar/Unipolar Trial, 56mm 1150-2358 Bipolar/Unipolar Trial, 58mm 1150-2361 Bipolar/Unipolar Trial, 61mm 1150-2364 Bipolar/Unipolar Trial, 64mm 1150-2368 Bipolar/Unipolar Trial, 68mm 1150-2372 Bipolar/Unipolar Trial, 72mm 1150-2414 Trial Head, V40-4mm 1150-2413 Trial Head, V40-3mm 1150-2400 Trial Head, V40 STD 1150-2404 Trial Head, V40 +4mm 1150-2408 Trial Head, V40 +8mm 1150-2412 Trial Head, V40 +12mm 1150-2416 Trial Head, V40 +16mm 1150-2512A Trial Head, C-Taper -2.5mm 1150-2513A Trial Head, C-Taper -3mm 1150-2500A Trial Head, C-Taper STD 1150-2503A Trial Head, C-Taper +2.5mm 1150-2505A Trial Head, C-Taper +5mm 1150-2508A Trial Head, C-Taper +7.5mm 1150-2510A Trial Head, C-Taper +10mm 1150-2600 Uni Adapter Sleeve UHR Bipolar Existing Instruments HI-UHRK-26 HI-UHRK-28 26mm UHR Head Removal Key 28mm UHR Head Removal Key UHT Universal Bipolar & Unipolar Instrument System Bottom Level 1150-2000 Instrument Case and Lid 1150-2100 Trial Head Handle 1150-2200 Cork Screw 1150-2700 Femoral Head Caliper Unitrax Bipolar Existing Instruments 6842-6-120 Sleeve to Head Disassembly Tool 6842-6-105 V40 Sleeve Removal Chuck 6842-6-106 C-Taper Sleeve Removal Chuck 6842-6-125 Sleeve to Trunion Disassembly Tool 6842-6-110 Unitrax Sleeve Impactor UHR Universal Head System Comprehensive Size Array Outer Inner Diameters Diameters 26mm 28mm 41mm UH1-41-26 42mm UH1-42-26 43mm UH1-43-26 44mm UH1-44-26 UH1-44-28 45mm UH1-45-26 UH1-45-28 46mm UH1-46-26 UH1-46-28 47mm UH1-47-26 UH1-47-28 48mm UH1-48-26 UH1-48-28 49mm UH1-49-26 UH1-49-28 50mm UH1-50-26 UH1-50-28 51mm UH1-51-26 UH1-51-28 52mm UH1-52-26 UH1-52-28 53mm UH1-53-26 UH1-53-28 54mm UH1-54-26 UH1-54-28 55mm UH1-55-26 UH1-55-28 56mm UH1-56-26 UH1-56-28 58mm UH1-58-26 UH1-58-28 61mm UH1-61-26 UH1-61-28 64mm UH1-64-26 UH1-64-28 68mm UH1-68-26 UH1-68-28 72mm UH1-72-26 UH1-72-28 References 1. Green S, Moore T, Proano F. Bipolar prosthetic replacement for the management of unstable intertrochanteric hip fractures in the elderly. Clinical Orthopaedics and Related Research. November 1987; 224:169-177. 2. Bowman AJ Jr, Walker MW, Kilfoyle RM, O Brien PI, McConville JF. Experience with the bipolar prosthesis in hip arthroplasty: A clinical study. Orthopedics. April 1985; 8(4): 460-467. 3. Nottingham RL. Treatment of a femoral neck fracture with a Universal Hip Replacement: A case report. Osteonics Clinical Case Reports. 1983. 4. Bernasek TL. Prosthetic replacement for extracapsular fractures of the hip. Techniques in Orthopaedics. 1989; 4(2): 49-55. 5. Takaoka, K, et al. Bipolar prosthetic replacement for the treatment of avascular necrosis of the femoral head. Clinical Orthopaedics and Related Research. April 1992; 277: 121-127. 6. Bochner RM, Pellicci PM, Lyden JP. Bipolar hemiarthroplasty for fracture of the femoral neck: Clinical review with special emphasis on prosthetic motion. Journal of Bone and Joint Surgery. August 1988; 70A(7): 1001-1010. 7. Sarmiento A, Gerarard F. Total hip arthroplasty for failed endoprostheses Clinical Orthopaedics and Related Research. Nov/Dec. 1978; 137: 112-117. 8. Austin-Moore Good results in femoral neck fractures. Orthopaedic Review. July 1983 Vol. XlI No.7: 84. Refer UHT Bipolar & Unipolar Instrument System Technique (Lit. No. LSP45) for protocol. Note: The UHT Bipolar & Unipolar Instrument System accommodates: - C-taper or V-40 trial heads - C-taper or V-40 Unitrax sleeve removal chucks - 26mm or 28mm UHR head removal keys The information presented in this brochure is intended to demonstrate the breadth of Stryker product offerings. Always refer to the package insert, product label and/or user instructions before using any Stryker product. Surgeons must always rely on their own clinical judgment when deciding which treatments and procedures to use with patients. Products may not be available in all markets. Product availability is subject to the regulatory or medical practices that govern individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. The marks bearing the symbol are trademarks of Stryker. The marks bearing the symbol are registered trademarks of Stryker. Literature Number: LUHRB MS/GS 1.5m 08/05 Copyright 2005 Stryker Printed in USA 325 Corporate Drive Mahwah, NJ 07430 t: 201-831-5000 www.stryker.com