SALES SUPPORT DOCUMENT ML-1630 MAXLOGIC SUPERVISOR SOFTWARE FOR MONITORING AND MANAGING ADDRESSABLE SYSTEM ML-1630 Supervisor software provides monitoring and controlling fire and fault events. Program is Windows based and easily using. PRODUCT FEATURES 1000 different intelligent addressable fire detection system can be monitored and managed with single supervisor Bulding projects can be uploaded to system.picture format doesn t matter Stratified presentation for each device Roaming between the maps automatically or manually in case of fire Ability to send remote commands in case of requiring intervention Event animations, device type and event voice can be changed according to user Fire, error and the other events can be grouped on event profile. By the help of this feature e-mail and/or sms report can be sent to authorized people at determined periods or instantly SDD-197 Rev.No:0 ML-1630 Maxlogic Supervisor Software For Monitoring and Managing Addressable System S/P 1/5
Event logging for every fire, fault, information and information and program start-up, sort by date and event type, print out options are available for event logs which are encolour listed CCTV system integration The communication with firefighter and other telephones is provided by the soft phone application Automatic or manual information messages can be sent to determined computers in case of fire The communication between PC and fire alarm system can be done via RS-232 or RS-485 and for longer distance GPRS or TCP/IP ports can be used. Network is monitored by GCU module or single panel is monitored by SGC module 10 different users can be defined MODELS Product code ML-1630 ML-1630.4 ML-1630.8 ML-1630.16 ML-1630.32 ML-1630.64 ML-1641 ML-1641.10 ML-1641.25 ML-1641.50 Description Supervisor graphically monitoring and managing software, for 1 panel Supervisor graphically monitoring and managing software, for 4 panels Supervisor graphically monitoring and managing software, for 8 panels Supervisor graphically monitoring and managing software, for 16 panels Supervisor graphically monitoring and managing software, for 32 panels Supervisor graphically monitoring and managing software, for 64 panels Superwiever dekstop 1 user Superwiever dekstop 10 user Superwiever dekstop 25 user Superwiever dekstop 50 user SDD-197 Rev.No:0 ML-1630 Maxlogic Supervisor Software For Monitoring and Managing Addressable System S/P 2/5
System Block Diagram Communication by Supervisor in Network Maxlogic Addressable System GCU (Gateway Control Unit); has been designed to monitor and manage ML-121X, ML-123X, ML-124X and ML-125XX series intelligent addressable fire alarm control panels through Supervisor Graphic Software. GCU is used for establishing the connection between fire alarm control panels and computer on which Supervisor Software is installed. This communication is provided via communication modules inside GCU. 4 different type of access can be provided between fire alarm control panel and computer on which Supervisor Software is installed: - Accessing control panel by using TCP/IP communication module through internet (LAN or WAN), - Accessing control panel by using GPRS communication module through internet with GSM Service Provider, - Accessing control panel by using RS-232 communication module at 15 meters, - Accessing control panel by using RS-485 communication module at 1200 meters. Each fire alarm control panel must have ML-1201 Network module in order to establish the connection between GCU and Maxlogic series fire alarm control panels and ML-12XX.N models must be selected. Up to 64 fire alarm control panels can be connected to each other in one network. 16 loops x 127 addresses x 64 control panels = 130.048 device can be included in one network. SDD-197 Rev.No:0 ML-1630 Maxlogic Supervisor Software For Monitoring and Managing Addressable System S/P 3/5
Panel 1 Panel 2 Network Operation RS232/RS485 TCP/IP Panel XX GCU Module GPRS Computer with installed Supervisor Panel 63 SDD-197 Rev.No:0 ML-1630 Maxlogic Supervisor Software For Monitoring and Managing Addressable System S/P 4/5
System Block Diagram Single panel system Supervisor communication ML-12011.XX SGC (Single Gateway Control) module is designed for controlling and graphical monitoring the single panel Maxlogic adrressable systems. Thus, Network module and GCU panel are not required to remote monitoring/controlling of the single panel Maxlogic addressable system. SGC module is mounted to network module place in intelligent addressable panels. TCP/IP RS485 RS232 SGC module Panel XX Single panel system Computer with installed Supervisor SDD-197 Rev.No:0 ML-1630 Maxlogic Supervisor Software For Monitoring and Managing Addressable System S/P 5/5