Video Verification Procedures for Burglar Alarms



Similar documents
Carbon Monoxide Supervising Station Response Standard

Types of Verification. Two broad forms of verification may be employed. These include:

1.1 Call to Order Mr. Ader called the meeting to order at 9:05 a.m. on Thursday, April 6, 2006.

DRAFT AGENDA. 1. Call to Order... T. Nesse. 2. Roll Call... M. Vago. 3. SIA Antitrust Policy... M. Vago. 4. Approval of Draft Agenda... T.

Peter Lowitt President Lowitt Alarms and Security Systems, Inc. Chairman CSAA Public Sector Liaison Committee

HOW TO REDUCE OR PREVENT FALSE ALARMS

A Consumer Guide to Purchasing a Burglar Alarm System and Understanding False Alarms

View. Select View Managed Video Services ADT

BARNSTABLE POLICE DEPARTMENT

Article 3. ALARM SYSTEMS. (08-08)

Alarm User Awareness Class. National Burglar & Fire Alarm Association

Melaleuca Home Security

ARTICLE IV: SECURITY ALARM SYSTEMS

The Computerworld Honors Program

PURPOSE AND GENERAL POLICY DEFINITIONS ALARM PERMITS (1) Permit Fees

ARTICLE 735. Emergency Alarm System

ORDINANCE NO

Alarm Management: Determining the Best Approach for Your Community

Comprehensive Video Solutions & Services. Industry-leading video solutions for your business

Videofied Video Verification A Guide for Central Monitoring Stations

ORDINANCE RELATIVE TO FALSE ALARMS

ARTICLE III. - FALSE FIRE ALARMS

Town of Stratton Regulations of Private Fire Alarm And Security Gate Systems

Comprehensive Security with one Powerful System. G Series integrated security, fire and access control panels

PRIVATE ALARM CONTRACTOR LICENSURE EXAMINATION INFORMATION

For the purpose of this chapter the following definitions shall apply:

ORDINANCE REGARDING ALARMS IN THE TOWN OF PLAINVILLE

1 HB By Representatives Whorton (I) and Davis. 4 RFD: Boards, Agencies and Commissions. 5 First Read: 07-APR-16.

Remote Security Management Addresses Security Challenges

COLORADO MODEL ALARM ORDINANCE

Low Cost Home Security Options. Jim Niehaus October 9, 2012

Think Remote Monitoring Think Concept Pro Think VXM4B

Security Alarm Monitoring Protocol

3, 2015 CENTRAL STATION REMOTE VIDEO MONITORING

Agenda Cover Memorandum

Video Alarm Verification Comes of Age

Chapter 67 ALARM SYSTEMS

Diebold Security. for Every Aspect of Your Business

ALARM SYSTEM REGULATIONS. BE IT ENACTED by the County Legislature of the County of Cattaraugus as follows:

Business Owner s. Security Buyers. Guide. Everything you need to know before purchasing a security system. Safer. Smarter. Tyco.

Security Service de Services sécurité. Security Alarm Monitoring Protocol

Commercial Security Systems. Securing Your Business Environment

Mansfield False Alarm Reduction Program Ordinance

Before the FEDERAL COMMUNICATIONS COMMISSION Washington, DC 20554

Guarded community solutions Easy Series for villa and apartment projects

What s Best. for You? Protecting What s Important to You

How To Set Up A Wide Area Surveillance System

What Should I Expect From My Alarm Monitoring Station?

CHAPTER 8. Village of Caledonia Alarm Systems Ordinance ( /01/13)

CHAPTER 4. Regulation of Private Alarm Systems

27558_Xtralis_MultiSiteBrochureREV_Eng_210x297_v1_a4 bro 04/05/ :24 Page 1 Multi-site security

The remote CCTV monitoring specialists CCTV Monitoring

Chapter 4. Regulation of Alarm Systems

GUIDE GETTING STARTED IMPORTANT SUPPORT RESOURCES

CHAPTER 13. Regulation of Alarm Systems

DRAFT CITY/COUNTY OF, TENNESSEE POLICE ALARM ORDINANCE

Home Security User Guide

CITY OF LYNN In City Council

Welcome to a whole new level of interactive home security

Reducing the Risk of Fire Through Telecare Commissioning Standards. London Fire Brigade

LYNX Touch Small Business Solutions DYNAMIC, FULL COLOR SELF-CONTAINED BUSINESS CONTROL SYSTEM. Your Connected Business

COURSE MANUAL. Alarm Verification Technologies from DSC. Module 1: Sales Training

CHAPTER 96: ALARM SYSTEMS

American National Standard For Electric Power Systems and Equipment Voltage Ratings (60 Hertz)

SECURITY & MONITORING QUICK GUIDE

Before the FEDERAL COMMUNICATIONS COMMISSION Washington, DC 20554

Model Burglar Alarm Ordinance

TPCA Model Alarm Ordinance Revision 3.1.2

Remote Client Program Web Client... 39

Tyco Integrated Security Managed Video Services. Gain enhanced security by leveraging your existing video surveillance equipment investment

Tyco Integrated Fire & Security Monitoring Services. Helping you secure your business 24 hours a day, 365 days a year. Safer. Smarter. Tyco.

Section 1: Definitions

DRAFT CITY/COUNTY OF, STATE POLICE ALARM ORDINANCE

TITLE 9-1 BURGLAR AND HOLDUP ALARM USERS REGISTRATION; FALSE ALARM

Chapter ALARM SYSTEMS. Sec Intent and purpose of chapter. Sec Definitions. Page 1 FOOTNOTE(S):

The ABC Of Security Systems - A Primer

Remote Monitoring offers a comprehensive range of services, which are continually

THIS ORDINANCE IS EFFECTIVE FEBRUARY 1, Sec Alarm systems; regulation and response.

Alarm information (fire alarms) CHAPTER 36 FALSE ALARMS

Maximizing the Value of Next-Generation Video Security Networks

Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?

How To Make A Private Security System Safe For A Home

AN ORDINANCE ESTABLISHING A SCHEDULE OF FINES FOR FALSE FIRE ALARMS. WHEREAS, the North Aurora Fire Protection District is a fire protection district

INSIDERS GUIDE BY BRIAN FABIANO Edition. Brian Fabiano s 6 Steps to Selecting a Home Security Company

ORDINANCE CITY OF NEW ORLEANS COUNCILMEMBERS WILLIAMS, HEAD, BROSSETT, CANTRELL AND GUIDRY (BY REQUEST)

SIA Digital Communication Standard Internet Protocol Event Reporting

Chapter 5.58 SECURITY ALARM SYSTEMS

Fire Alarm Response and Management Summit Washington Dulles Hilton, Park Center Road, Herndon, VA 20171

Technology, Safety and ISRI. Garry Mosier CSP VP of Operations Alliance Wireless Technologies, Inc.

FARA/NBFAA Model Burglar Alarm Ordinance

W H I T E P A P E R. Security & Defense Solutions Intelligent Convergence with EdgeFrontier

Surveillance Equipment

MINUTES OF THE NORTH CAROLINA ALARM SYSTEMS LICENSING BOARD. Raleigh, North Carolina. Deputy Director

Agenda. Time Topic Speaker

Your Canadian Security Specialists. Eddie D Orazio

Security Technology. Virtual

Elements of Physical Security Systems II: Intrusion Detection, Alarm Communication and Assessment, Delay, and Response

City of Temple Burglar Alarm Permit Process Information Sheet

Central Station Interface with Fire Alarm and the Relevant Codes & Standards

Transcription:

Video Verification Procedures for Burglar Alarms ANSI/CSAA CS-V-02-2012 Page 1 of 11 Last Revised: 10/7/11

Contents Foreword. 3 Acknowledgments.. 4 Introduction. 6 1 Scope 7 2 General 7 3 Definitions 7 4 Standard Procedures 9 4.1 Identification of a Video Verification System 9 4.2 Procedure for Alarm Signals Received from Systems 9 4.3 When to Use Video Verification 9 4.4 Reviewing Video... 10 4.5 Notification Call.. 10 5 Recommended Video Implementation Techniques 10 5.1 Monitoring Facilities Recommendations.. 10 5.3 Field of View 10 5.2 Premise Camera Position.. 10 5.3 Field of View. 11 Page 2 of 11 Last Revised: 10/7/11

Foreword This standards document is published by the Central Station Alarm Association (CSAA) and was developed and adopted by a consensus of industry volunteers in accordance with CSAA s standards development policies and procedures. CSAA assumes no responsibility for the use, application or misapplication of this document. Industry members using this document, particularly those having participated in its development and adoption, are considered by CSAA to have waived any right they might otherwise have had to assert claims against CSAA regarding the development process of this standard. CSAA reserves the right to revise this document at any time. Because CSAA policy requires that every standard be reviewed periodically and be revised, reaffirmed, or withdrawn, users of this document are cautioned to obtain and use the most recent edition of this standard. Current information regarding the revision level or status of this or any other CSAA standard may be obtained by contacting CSAA. Requests to modify this document are welcome at any time from any party, regardless of membership affiliation with CSAA. Such requests, which must be in writing and sent to the address set forth below, must clearly identify the document and text subject to the proposed modification and should include a draft of proposed changes with supporting comments. Such requests will be considered in accordance with CSAA's standards development policies and procedures. Written requests for interpretations of a CSAA standard will be considered in accordance with CSAA's standards development policies and procedures. While it is the practice of CSAA staff to process an interpretation request quickly, immediate responses may not be possible since it is often necessary for the appropriate standards subcommittee to review the request and develop an appropriate interpretation. Requests to modify a standard, requests for interpretations of a standard, or any other comments are welcome and may be sent to: Central Station Alarm Association, 8150 Leesburg Pike, Suite 700, Vienna, VA 22182; phone: 703-242-4670; www.csaaintl.org. This document is owned by the Central Station Alarm Association and may not be reproduced, in whole or part, without the prior written permission from CSAA. Page 3 of 11 Last Revised: 10/7/11

ACKNOWLEDGEMENTS CSAA Standards Chairman: Louis T. Fiore, L.T.Fiore, Inc. CSAA Committee Chairman: James McMullen, C.O.P.S. Monitoring CSAA Staff Administrator: Stephen P. Doyle, Executive Vice President, CSAA Company First Name Last Name A-1 Security Bud Wulforst* ADT Larry Dischert* ADT Tom Nakatani* ADT Brooke Smith* American Alarm Dick Sampson Bay Alarm Company Shane Clary Burns & Levinson, LLP Gil Breiman COPS Monitoring Jim McMullen* D3 Data David Boyce D3 Data Don St. Mary Diebold Mark Burnett Diebold Steve Ipson DMP Terry Shelton DSC Kevin Harris DSC Sascha Kylau DSC Dan Nita Emergency 24 Patrix Deveraux* Emergency 24 Kevin McCarthy Honeywell Bridget Lehmann Honeywell Jed McComber Knight Security Center Christopher Baskin Optex, Inc. Scott Simmons Oz Vision Shahar Belkin Oz Vision Avi Lupo* Oz Vision Tim Root Richard Hahn & Associates Richard Hahn Salitent Systems Per Hanssen Security Solutions Peter Orvis* Page 4 of 11 Last Revised: 10/7/11

Sonitrol Frank Minni Teldat Agustin Munoz Tyco Bernie Worst* UL Steven Schmit Vector Security Rick Simpson* Wayne Alarm Company Ralph Sevinor George Brody Rod Coles David Ella Lou Fiore John Judd Gary Kallman Mike Sheehan *Indicates active members. Page 5 of 11 Last Revised: 10/7/11

CS-V-02 Video Verification Procedures for Burglar Alarms Introduction This standard defines methods for using video as just one of many different technologies by which false dispatches can be reduced. It has been proven that verification of alarm signals regardless of the method used by a monitoring central station will considerably reduce false dispatches to municipal authorities or others responsible to take such like actions. This standard focuses on how to use video to verify alarm signals and to increase the possibility of visually identifying the source of the alarm event. While it is a goal of this standard to help in reducing the number of false dispatches; it also is a goal to provide enhanced information when available and when an alarm needs to be reported to authorities. While there are a multitude of positive applications for video surveillance, and though it may be useful in selective alarm system accounts, it is not effective in enough scenarios to use as a global dispatch reduction tool, and shall not be a requirement for police dispatch alone. The field of Video Verification is an evolving technology. It is not the intent of this standard to prohibit or limit new verification technologies or advancements provided the minimum requirements in this standard are met. Page 6 of 11 Last Revised: 10/7/11

Alarm Verification and Notification Procedures 1 Video Verification Scope This standard has been prepared under the direction of the Security Industry Standards Council (SISC) members with the participation of the Central Station Alarm Association (CSAA) members, and the Security Industry Association (SIA) members. The standard is recommended for use by alarm monitoring facilities and by State and Local governments as a minimum industry standard for good practice in the use of video for alarm monitoring applications to aid in alarm verification. New technologies and efforts to reduce false alarms through other enhanced verification techniques have led to this standard. In summation video verification shall be considered one of the methods used by the industry to enhance existing verification techniques but not as a standalone requirement in order to request police response. 2 General If differences exist between this standard and other written Special Instructions with the monitored premises; the Special Instructions shall take precedence. 3 Definitions 3.1 Alarm Verification - reference ANSI/CSAA CS-V-01 3.2 Video Verification Video Verification is the pairing of video data with alarm events generated from protected premises. This pairing may assist in determining the response protocol to be followed for the alarm event. Page 7 of 11 Last Revised: 10/7/11

3.3 Standard Verification - reference ANSI/CSAA CS-V-01 3.4 Enhanced Verification - reference ANSI/CSAA CS-V-01 3.5 Remote Video Investigation Remote Video Investigation is the procedure where monitoring facility personnel uses a live video connection or recorded video clips, pictures, and other data to remotely view the premises as a follow up method after an alarm event has been transmitted. The viewing of video and associated information of the premises occurs after the initial alarm. In effect the facility personnel may or may not be viewing the actual activity that initiated the alarm but are reviewing the video information provided after receiving the alarm event in an attempt to observe activity that may provide information about the alarm event. This method can add information to the Alarm Verification but is not considered verifying an alarm as the video may not contain information that is captured at the time of the alarm or directly associated with the alarm event. 3.6 Captured Video Information Captured Video is associated video information aligned with the alarm event and/or identified by the monitoring facility personnel while viewing video. Examples include the following: the presence of video aligned with the alarm, the identification of a human or humans, or any other information germane to the alarm scene (broken window, smashed door, or other physical characteristics) at the time of the alarm event. 3.7 Special Instructions A written, separate document from the monitoring contract document, that specifies a specific set of instructions to be followed in the event of an alarm, between the monitored premises and the alarm/monitoring company. This may also be made available to the operator on screen automatically on activation of the alarm. 3.8 Notification Call - reference ANSI/CSAA CS-V-01 3.9 Captured Frame Video The minimum number of alarm event frames made available to the operator shall be that necessary on each alarm for a reasonable person to successfully identify the cause of the alarm. Page 8 of 11 Last Revised: 10/7/11

In applications in which video capture, recording and transmission cannot be assured to begin within 300 milliseconds (300msec) of the actual time of the alarm event, then at least 2 (two) frames shall be captured before the event, 1 (one) at the time of the event and 2 (two) after the event. The minimum amount of time of captured video shall be 5 (five) seconds. As an example if the minimums are implemented, at least 5 frames of captured video spanning five seconds starting no more than 100 milliseconds after the actual alarm event will be captured and transmitted. Alternately, in applications where the time between alarm initiation and recording of the first of the required five frames cannot be assured to be within 100 milliseconds, then 5 (five) frames would be distributed over 5 (five) seconds (1 (one) second between full frames) with two frames containing pre alarm video, the event frame being the third, and two frames of post event video 4 Standard Video Verification Procedures 4.1 Identification of a Video Verification System Each alarm signal with Video Verification shall be identified by the monitoring facility personnel that additional video information is associated with the standard alarm signal received. The use of Video Verification shall only be used to enhance other alarm verification methods. 4.2 Procedure for Alarm Signals Received from Systems In accordance with ANSI/CSAA CS-V-01 standard, unless Special Instructions exist, the monitoring facility personnel shall make contact with the protected premises for authorized identification and verification upon receiving an alarm unless the cause of the alarm can be ascertained with a degree of certainty by the operator through use of the received pre-recorded or live video. 4.3 When to Use Video Verification Video information shall be combined with other verification techniques to identify personnel or zone patterns that may verify that no emergency exists. Page 9 of 11 Last Revised: 10/7/11

Video information does not need to be considered in the case when an alternative method of verifying that no emergency is present supersedes the viewing of the video, such as if the initial contact with the protected premise finds authorized personnel at the premises and/or the person states that no emergency exists. 4.4 Reviewing Video 4.4.1 4.4.2 Video information will be reviewed by the monitoring facility prior to initiating a Notification Call if no other approved alternative method can verify that an emergency does not exist Monitoring facility personnel should spend no more than 2 minutes reviewing video information and attempt to verify. If the video feed is unavailable or not viewable, monitoring facility personnel should proceed with alternate verification methods. 4.5 Notification Call The Notification Call detail will include information that has been reviewed by the monitoring facility personnel to indicate whether or not there is Captured Video Information associated with the alarm event; to indicate information has been gathered to indicate if an emergency exists. The details shall include a statement to the effect that the protected premises does support Video Verification but either no video was associated with the alarm or the Captured Video Information did not reveal conclusive information about the alarm. 5 Video Implementation Techniques The quality of the video received shall be of a nature that a person will at a minimum, be able to decipher between a human and non-human based on the attributes of human form or any other information germane to the alarm scene (broken window, smashed door, or other physical characteristics) at the time of the alarm event. 5.1 Monitoring Facilities Page 10 of 11 Last Revised: 10/7/11

It is recommended that the Captured Video be transmitted and available to the monitoring facility when the alarm event is transmitted. The alarm event and captured video do not need to be transmitted over the same medium. The monitoring facility personnel shall have the Captured Video presented in a manner that is easily accessible. 5.2 Premises Camera Position The camera should be placed to provide a clean view of the protected area. Care should be taken to avoid Cameras that can be repositioned for other purposes (ex. Review product displays or check customer traffic). 5.3 Field of View It is required that the Captured Video field of view include the area covered by the sensor that triggered the alarm event. If the sensor is a motion sensor then the captured video shall be aligned with the motion sensors coverage area. The field of view may also be more than one camera with more than one alarm event. ANNEX: The type of camera, video transmission, placement of equipment and views provided by such video equipment may serve different needs for the consumer. If determined by the consumer that a different configuration is desired, deviation from the placement and functionalities described in this standard should not prohibit the central station from utilizing such video information in its course of performing a notification to the law enforcement agency if appropriate. Page 11 of 11 Last Revised: 10/7/11