EMC VNX VG8 GATEWAY. Specifications ARCHITECTURE



Similar documents
EMC VNX VG2 GATEWAY. Specifications ARCHITECTURE

EMC VNXe3150, VNXe3300 UNIFIED STORAGE SYSTEMS

EMC VNX5500-F UNIFIED STORAGE FLASH ARRAY

EMC VNX SERIES UNIFIED STORAGE SYSTEMS

LENOVO EMC VNX5150 STORAGE ARRAY SPECIFICATIONS

VNX Physical Specifications

EMC SYMMETRIX VMAX 10K

EMC VNXe3200 UNIFIED STORAGE SYSTEM

EMC SYMMETRIX VMAX 20K STORAGE SYSTEM

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC VNX SERIES DC POWERED UNIFIED STORAGE SYSTEMS

EMC VNX SERIES UNIFIED STORAGE SYSTEMS

EMC Celerra Gateway. Reach new heights of availability, scalability, and flexibility with EMC Celerra Gateway platforms: NS40G and NS-G8

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC VNX FAMILY. Copyright 2011 EMC Corporation. All rights reserved.

EMC ISILON HD-SERIES. Specifications. EMC Isilon HD400 ARCHITECTURE

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC Celerra NS Series/Integrated

EMC Celerra Unified Storage

EMC ISILON NL-SERIES. Specifications. EMC Isilon NL400. EMC Isilon NL410 ARCHITECTURE

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC CLARiiON AX150/AX150i

EMC VMAX3 FAMILY - VMAX 100K, 200K, 400K

EMC VMAX3 FAMILY VMAX 100K, 200K, 400K

IP Storage in the Enterprise Now? Why? Daniel G. Webster Unified Storage Specialist Commercial Accounts

EMC ISILON X-SERIES. Specifications. EMC Isilon X200. EMC Isilon X210. EMC Isilon X410 ARCHITECTURE

EMC Business Continuity for Microsoft SQL Server 2008

UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

IBM TotalStorage Network Attached Storage 300G

Network Attached Storage 300

STORAGE CENTER WITH NAS STORAGE CENTER DATASHEET

IBM TotalStorage Network Attached Storage 100

EMC Backup and Recovery for Microsoft SQL Server

Data Sheet Fujitsu ETERNUS DX200 S3 Disk Storage System

TotalStorage Network Attached Storage 300G Cost effective integration of NAS and LAN solutions

Dynamically unify your data center Dell Compellent: Self-optimized, intelligently tiered storage

Symantec NetBackup 5220

EMC VNX-F ALL FLASH ARRAY

Data Sheet Fujitsu ETERNUS CS High End V5.1 Data Protection Appliance

Storage System. Planning Checklist. EC E1, First Edition

WHITEPAPER: Understanding Pillar Axiom Data Protection Options

Cisco and EMC Solutions for Application Acceleration and Branch Office Infrastructure Consolidation

Reference Architecture. EMC Global Solutions. 42 South Street Hopkinton MA

Virtual Provisioning. Management. Capacity oversubscription Physical allocation on the fly to logical size. With Thin Provisioning enabled

ANNEX III BUDGET PROPOSAL AS PER LOTS LOT 1

EMC Backup and Recovery for Microsoft SQL Server

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

1. Specifiers may alternately wish to include this specification in the following sections:

EMC VNX FAMILY. Next-generation unified storage, optimized for virtualized applications ESSENTIALS. VNX Family

Symantec NetBackup 5000 Appliance Series

EMC CLARiiON AX4 Storage System

Overland 2 TB SnapServer 210 NAS Server. Overland 4 TB SnapServer 210 NAS Server Operating System GuardianOS GuardianOS

EMC RECOVERPOINT FAMILY

Selling Compellent NAS: File & Block Level in the Same System Chad Thibodeau

Data Communications Hardware Data Communications Storage and Backup Data Communications Servers

Data Sheet FUJITSU Storage ETERNUS DX500 S3 Disk System

ACCELERATING YOUR IT TRANSFORMATION WITH EMC NEXT-GENERATION UNIFIED STORAGE AND BACKUP

ADVANCED FILE SHARING AND MANAGEMENT

Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs

EMC Integrated Infrastructure for VMware

760 Veterans Circle, Warminster, PA Technical Proposal. Submitted by: ACT/Technico 760 Veterans Circle Warminster, PA

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System

EMC VPLEX FAMILY. Continuous Availability and Data Mobility Within and Across Data Centers

modular Storage Solutions MSS Series

STORAGETEK 2540 ARRAY

MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220

CONFIGURATION GUIDELINES: EMC STORAGE FOR PHYSICAL SECURITY

Discover Smart Storage Server Solutions

Simplify Data Management and Reduce Storage Costs with File Virtualization

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture

Virtual Data Movers on EMC VNX

EMC Approach to Data Center Virtualization

Configuring Celerra for Security Information Management with Network Intelligence s envision

Cisco MCS 7825-H3 Unified Communications Manager Appliance

EMC VNXe Series. Configuring Hosts to Access CIFS File Systems. Version 3.1 P/N REV. 03

INTRODUCTION TO THE EMC VNX SERIES

Building the Virtual Information Infrastructure

10th TF-Storage Meeting

EMC VPLEX FAMILY. Continuous Availability and data Mobility Within and Across Data Centers

EMC Integrated Infrastructure for VMware

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

HUAWEI Tecal E6000 Blade Server

Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs

Cisco 7816-I5 Media Convergence Server

EMC Backup and Recovery for Microsoft Exchange 2007 SP2

EMC DATA DOMAIN DD990

Symantec NetBackup Appliances

EMC VSPEX END-USER COMPUTING

VBLOCK TM INFRASTRUCTURE PLATFORMS: A TECHNICAL OVERVIEW

EMC PERSPECTIVE: THE POWER OF WINDOWS SERVER 2012 AND EMC INFRASTRUCTURE FOR MICROSOFT PRIVATE CLOUD ENVIRONMENTS

Application Server V240 Platform

Isilon OneFS. Version OneFS Migration Tools Guide

EMC Backup and Recovery for Oracle Database 11g Without Hot Backup Mode using DNFS and Automatic Storage Management on Fibre Channel

EMC DATA DOMAIN OPERATING SYSTEM

Transcription:

EMC VNX VG8 GATEWAY The EMC VNX VG8 platform extends the value of existing EMC storage array technologies. It delivers a comprehensive, consolidated solution that adds NAS storage in a centrally managed information storage system, enabling you to dynamically grow, share, and cost effectively manage file systems with multi-protocol file access. If you are looking for a massively scalable EMC IP storage solution to extend your existing storage investment, or want an enterprise, SAN-plus-NAS platform, choose the VNX VG8 Gateway product. Specifications ARCHITECTURE The VNX VG8 Gateway system supports flexible X-Blade configurations, from 2 to 8 blades. X-Blade configurations are deployed in N+M Primary/Standby mode with N active blades and M pooled failover blades for flexible hardware availability protection (i.e., X-Blade failover). Each X-Blade consists of the following: The latest 64 bit Intel Xeon 5600 Processor (6-core 2.83 GHz CPUs with 12 MB of Layer 3 cache) 24 GB Double Data Rate 3 DRAM (1333 MHz) Two 8 Gb/s Fibre Channel or 10 Gb/s Fibre Channel over Ethernet (FCoE) ports for storage connectivity Up to two 8 Gb/s Fibre Channel ports for tape connectivity One 10/100/1000 management port Instance of VNX Operating Environment for File software Ethernet Blade options (all X-Blades in a single VG8 system must contain the same Ethernet configuration): Four EMC UltraFlex slots are available for adding any mix of the following I/O modules: Four ports 10/100/1000 BaseT Two ports 10/100/1000 BaseT plus two ports 1 Gb Ethernet Optical Two ports 10 Gb Ethernet Optical The VNX VG8 connects via Fibre Channel or FCoE SAN to: EMC Symmetrix storage systems EMC VNX series storage platforms EMC CLARiiON storage systems Tape transport for direct backup-to-tape (NDMP) X-Blades can be added non-disruptively up to an eight X-Blade configuration. Performance scales linearly up to a maximum of seven active blades. SPECIFICATION SHEET

Platform managed by one or two Control Stations: Connection to each X-Blade via Gigabit Ethernet Management connection via 10/100/1000 Ethernet port Manages X-Blade failover Manages all file systems via GUI SNMP MIB II manageability Secure Shell (SSH) for remote access HTTP server management interface One 500 GB SATA hard drive One DVD-ROM drive VNX FILE SERVER FACILITIES Protocols supported: NFSv2, v3, and v4 (including NFSv4.1 with pnfs support); CIFS (SMB 1 and SMB 2); FTP; FTP Secure (FTP over SSL); and IPv6 Network Lock Manager (NLM) v1, v3, and v4 Common Criteria Certification: EAL 3+ Assurance Level Routing Information Protocol (RIP) v1 v2 Simple Network Management Protocol (SNMP v1, v2, and v3) Network Data Management Protocol (NDMP) v1 v4 Address Resolution Protocol (ARP) Internet Control Message Protocol (ICMP) Network Time Protocol (NTP) client Simple Network Time Protocol (SNTP) Kerberos Authentication Lightweight Directory Access Protocol (LDAP) Optional VNX software facilities: EMC Unisphere Provides a consolidated interface to manage both VNX, CLARiiON and Celerra platforms VNX Event Enabler (VEE) Integration facilities with third-party vendors Anti-virus VNX integration with industry-leading, anti-virus vendors Event publishing VNX integration with industry-leading quota-management and auditing vendors EMC VNX Replicator Replicate over IP for disaster recovery, backup, and/or testing VNX File-Level Retention (FLR) Create WORM (write once/read many) file systems with specified retention periods; support for both an enterprise and compliance option VNX Multi-Path File System (MPFS) Delivers improved performance and scalability over traditional NAS Note: Virtual Provisioning, Deduplication, and EMC SnapSure are bundled. Client connectivity facilities: File access by FTP, NFS (including pnfs), CIFS, and MPFS Block access by native array connectivity (iscsi and FC) Virtual Data Movers for Microsoft Windows clients Ethernet trunking Link aggregation (IEEE 802.3ad) Virtual LAN (IEEE 802.1q) UNIX archive utilities (tar/cpio) Network Status Monitor (NSM) v1 Portmapper v2

Network Information Service (NIS) client Supports Microsoft DFS as leaf node or root server Native Windows 2000/2003/2008 support NT LAN Manager (NTLM) LDAP signing for Windows Server Microsoft Windows Server 2003 Access-based Enumeration (ABE) HIGH-AVAILABILITY FEATURES VG8 X-Blade enclosure: Redundant power supplies for X-Blades and Control Stations Hot-swappable power and cooling Internal environmental status monitoring VNX Operating Environment for File software capabilities: Automated Volume Management (AVM) File system provisioning Virtual provisioning Allows for logical sizing and physical provisioning SnapSure Creates read-only or read-write, point-in-time logical snaps Monitoring At-a-glance system status and performance statistics Data deduplication File-based deduplication and compression FileMover API Open API for automated, transparent data movement between tiers of storage SMI-S v1.4 management API Ethernet Trunking Link aggregation Failsafe networking Network interface port failover N to M X-Blade failover Optional VMware facilities: VNX Plug-in for VMware For provisioning, management, cloning, and deduplication EMC PowerPath /VE Path management for iscsi and Fibre Channel Site Recovery Manager (SRM) Managing failover and failback making disaster recovery rapid and reliable Replication Manager: Host-based management of array-based copies of data Additional facilities: PowerPath Path management Replication Manager Host-based management of array-based copies of data Cloud Tiering Appliance: transparent file-based tiering within and across platforms Control Station: Administration and management X-Blade installation and configuration X-Blade failover Monitor diagnostics Configuring network interfaces Creating and exporting file systems File-system consistency checks Extending file systems Auto-call event alerting Call-in remote maintenance Note: Optional second control station is supported.

VNX Series/CLARiiON storage: Disk scrubbing Mirrored write cache with de-stage AC power loss Redundant hot-swap power, bus structures, and I/O subsystems Online global hot-spare disks PowerPath failover for Windows and UNIX hosts Symmetrix storage: Automatic cache and disk scrubbing Mirrored write cache and battery backup for AC power loss ride through Auto-call remote monitoring Redundant hot-swap power, bus structures, and I/O subsystems Online global hot-spare disks PowerPath failover for Windows and UNIX hosts DIMENSIONS (APPROXIMATE) Measurement item Height: Width: Depth: Weight: 17.5 in. (44.45 cm) 10 NEMA UNITS (U), Control Station 1 U, Blade enclosure 2U, including mounting rails (fully configured with two Control Stations and blade enclosures having eight blades) 18.92 in. (48.06 cm); mounting bars fit standard 19-inch NEMA cabinets Chassis to rear: 24.25 in. (61.6 cm) VG8 with 8 X-Blades: 245.2 lb (111.22 kg); four blade enclosures, two Control Stations VG8 with 2 X-Blades: 56.8 lb. (25.76 kg) OPERATING ENVIRONMENT Temperature: 50 104 degrees F (10 40 degrees C) Temperature gradient: Relative Humidity: 18 degrees F/hr (10 degrees C/hr) 20 percent to 80 percent (non-condensing) Altitude (max.): 7,500 ft. (2,286.4 m) @ 104 degrees F (40 degrees C) AC POWER AND DISSIPATION Temperature: 50 104 degrees F (10 40 degrees C) Temperature gradient: Relative Humidity: 18 degrees F/hr (10 degrees C/hr) 20 percent to 80 percent (non-condensing) Altitude (max): 7,500 ft. (2,286.4 m) @ 104 degrees F (40 degrees C)

Requirement: VG8 with 8 X-Blades* VG8 with 2 X-Blades AC line voltage 100 to 240 V AC, 50-60 Hz, single-phase 100 to 240 V AC, 50-60 Hz, single-phase AC line voltage tolerance Voltage ± 10%, frequency ± 3 Hz Voltage ± 10%, frequency ± 3 Hz AC line current (operating 24.7 A maximum at 100 V AC, 12.4 A maximum at 200 V AC 5.9 A maximum at 100 V AC, 3.0 A maximum at 200 V AC Power consumption (operating 2,470 VA (2,290 W) maximum 590 VA (550 W) maximum Power factor 0.93 minimum at full load, low voltage 0.93 minimum at full load, low voltage Heat dissipation (operating 8.24 x 10 6 J/hr, (7,800 Btu/hr) maximum 1.98 x 10 6 J/hr, (1,900 Btu/hr) maximum In-rush current Startup surge current AC protection AC receptacle 95 A maximum for ½ line cycle, per line cord at 240 V AC 48 A maximum for ½ line cycle, per line cord at 120 V AC 88 A rms maximum for 50 ms, at any line voltage 7.8 A fuse on each power supply, both phases IEC320-C14 appliance coupler, per power supply 20 A maximum for ½ line cycle, per line cord at 240 V AC 10 A maximum for ½ line cycle, per line cord at 120 V AC 22 A rms maximum for 50 ms, at any line voltage 7.8 A fuse on each power supply, both phases IEC320-C14 appliance coupler, per power supply Ride-through time 30 ms minimum 30 ms minimum Current sharing *Includes first control station. ± 15% of full load, between power supplies ± 15% of full load, between power supplies CONTACT US To learn more about how EMC products, services, and solutions can help solve your business and IT challenges, contact your local representative or authorized reseller or visit us at www.emc.com. EMC 2, EMC, CLARiiON, VNX, Celerra, PowerPath, SnapSure, Symmetrix, UltraFlex, Virtual Provisioning, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries. VMware is a registered trademarks or trademarks of VMware, Inc., in the United States and other jurisdictions. Copyright 2010, 2013 EMC Corporation. All rights reserved. Published in the USA. 4/13 Specification Sheet H7293.5 EMC believes the information in this document is accurate as of its publication date. The information is subject to change without notice. EMC Corporation Hopkinton, Massachusetts 01748-9103 1-508-435-1000 In North America 1-866-464-7381 www.emc.com