FIRST EXPERIENCE WITH THE ZEISS FEMTOSECOND SYSTEM IN CONJUNC- TION WITH THE MEL 80 IN THE US



Similar documents
Uniquely Safe. predictably better for our patients. enhancement, may be significantly reduced.

ALL-LASER LASIK USING THE ZEISS VisuMax MEL 80 REFRACTIVE WORKSTATION

Richard S. Hoffman, MD. Clinical Associate Professor of Ophthalmology Oregon Health & Science University

Ophthalmology Department,Tanta University, Egypt

PATIENT CONSENT FOR LASER IN-SITU KERATOMILEUSIS (LASIK)

Alexandria s Guide to LASIK

The pinnacle of refractive performance.

Preliminary U.S. FDA Outcomes of SMILE

Comparison of Residual Stromal Bed Thickness and Flap Thickness at LASIK and Post-LASIK Enhancement in Femtosecond Laser-Created Flaps

Comparison Combined LASIK Procedure for Ametropic Presbyopes and Planned Dual Interface for Post-LASIK Presbyopes Using Small Aperture Corneal Inlay

Consumer s Guide to LASIK

VISX Wavefront-Guided LASIK for Correction of Myopic Astigmatism, Hyperopic Astigmatism and Mixed Astigmatism (CustomVue LASIK Laser Treatment)

IntraLase Corp. Clinical Studies Fact Sheet

TABLE OF CONTENTS: LASER EYE SURGERY CONSENT FORM

Retreatment by Lifting the Original Laser in Situ Keratomileusis Flap after Eleven Years

IntraLase and LASIK: Risks and Complications

Femtosecond Lasers in LASIK Surgery

Financial Disclosure. LASIK Flap Parameters IntraLase Microkeratome 6/9/2008. Femtosecond LASIK Flaps: What Could We Customize Yesterday?

Eye Associates Custom LASIK With IntraLASIK Correction Of Nearsightedness, Farsightedness, and Astigmatism Using IntraLase TM Technology

Case Reports Post-LASIK ectasia treated with intrastromal corneal ring segments and corneal crosslinking

Long-Term Outcomes of Flap Amputation After LASIK

Accelerated Refractive Performance

OCT-guided Femtosecond Laser for LASIK and Presbyopia Treatment

Laser in situ keratomileusis (LASIK) has been. Retreatment of Hyperopia After Primary Hyperopic LASIK REPORTS

Long-term stability of the posterior cornea after laser in situ keratomileusis

INTRACOR. An excerpt from the presentations by Dr Luis Ruiz and Dr Mike Holzer and the Round Table discussion moderated by Dr Wing-Kwong Chan in the

RELEX SMILE AND SMILE EXTRA.. OUR 1 YEAR RESULTS AND PATIENTS SURVEY

INFORMED CONSENT FOR LASER IN-SITU KERATOMILEUSIS (LASIK) USING INTRALASE TM BLADE-FREE TECHNOLOGY

Case Report Laser Vision Correction on Patients with Sick Optic Nerve: A Case Report

ALTERNATIVES TO LASIK

Overview of Refractive Surgery

LASIK SURGERY IN AL- NASSIRYA CITY A CLINICOSTATISTICAL STUDY

Patient-Reported Outcomes with LASIK (PROWL-1) Results

LASIK Eye Surgery Report

LASIK Enhancement Commitment

INFORMED CONSENT FOR LASER IN-SITU KERATOMILEUSIS (LASIK)

Evolution of Refractive Surgery 2003

Consent for Bilateral Simultaneous Refractive Surgery

Cross-Linking with Refractive Surgery: Pros and Cons

Laser Vision Correction: A Tutorial for Medical Students

CustomVue Treatments for Monovision in Presbyopic Patients with Low to Moderate Myopia and Myopic Astigmatism

Our Commitment To You

XXXII nd Congress of the ESCRS, London, September 13, 2014 Instructional Course # 7. LASIK: basic steps for safety and great results

CENTRO OFTALMOLOGICO GUSTAVO TAMAYO BOGOTA COLOMBIA LASIK XTRA GUSTAVO TAMAYO MD CLAUDIA CASTELL MD PILAR VARGAS MD

Initial Supervised Refractive Surgical Experience: Outcome of PRK and LASIK

ReLEx smile Minimally invasive vision correction Information for patients

To date, several million patients have been treated worldwide. So why not discover the benefits The Eye Hospital can bring to your life.

Femto-LASIK. Pulsewidth: Ultrashort-pulse micro- machining can make sub- wavelength holes. micromachining

LASIK Wavefront Guided idesign LASIK with IntraLase

CONSENT FOR INTRALASIK CORRECTION OF NEARSIGHTEDNESS, FARSIGHTEDNESS, AND ASTIGMATISM USING INTRALASE TM TECHNOLOGY BY AMJAD KHOKHAR, M.D.

Challenging Refractive Surgery Cases. Vance Thompson, MD, FACS Refractive and Cataract Surgery Vance Thompson Vision Sioux Falls, South Dakota

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

Refractive Surgery Issue. Inlays and Presbyopia: On the Horizon P. 24. Crack a SMILE or Raise a Flap? P. 30. LASIK Xtra: Who Should Get It? P.

Cornea and Refractive Surgery Update

Minimally Invasive Surgery: Femtosecond Lasers and Other Innovative Microsurgical Techniques

Life Science Journal 2014;11(9) Cross cylinder Challenging cases and their resultswith Nidek Quest (EC-5000)

Is LASIK Good Enough? 75% of flights have a CL wearer 53% of all EVAs have either a spectacle or CL wearer Microbial keratitis has occurred

Corneal flap thickness with the Moria M2 single-use head 90 microkeratome

Wavefront technology has been used in our

Initial clinical experience with the FS200 Femto and EX500 excimer

Vision Correction Surgery Patient Information

Your Eyes Are As Unique As You Are

Refractive Surgery. Common Refractive Errors

LASIK in the Presbyopic Age Group

Comparing Femtosecond Lenticule Extraction (FLEx) and Femtosecond Laser In-situ Keratomileusis (LASIK) for Myopia and Astigmatism

LASIK. Complications. Customized Ablations. Photorefractive Keratectomy. Femtosecond Keratome for LASIK. Cornea Resculpted

Introducing TOPOGRAPHY-GUIDED REFRACTIVE SURGERY

Refractive Surgery. Evolution of Refractive Error Correction

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Despite being a relatively safe and

What Laser Vision Correction Means to the Military

Multi-Centre Evaluation of TransPRK outcomes with SCHWIND AMARIS using SmartPulse Technology

KERATOCONUS IS A BILATERAL, ASYMMETRIC, CHRONIC,

Standardized Analyses of Correction of Astigmatism With the Visian Toric Phakic Implantable Collamer Lens

Pre-Operative Laser Surgery Information

LASIK SURGERY OUTCOMES, VOLUME AND RESOURCES

Excimer Laser Refractive Surgery

Alain Saad, MD, Alice Grise-Dulac, MD, Damien Gatinel, MD, PhD

Conductive keratoplasty (CK) utilizes radiofrequency energy. Original Article

Medical Director, Shinagawa LASIK Center, Tokyo, Japan Adjunct Professor, Department of Ophthalmology, Wenzhou Medical College, Wenzhou, China

LASIK for Hyperopia With the WaveLight Excimer Laser

Welcome to the Verisyse Seminar

Patient Information Booklet Information for patients considering Laser Assisted In-Situ Keratomileusis (LASIK) Surgery

Buttonholes in 315,259 LASIK procedures

VA high quality, complications low with phakic IOL

Looking for Keratoconus

Vision Correction Surgery - What Are the Risks and Complications?

INFORMED CONSENT FOR LASIK SURGERY

Post LASIK Ectasia. Examination: Gina M. Rogers, MD and Kenneth M. Goins, MD

How To See With An Cl

What is Refractive Error?

LASIK & Refractive Surgery

Common Co-management Questions

By Dr Waleed Al-Tuwairqi, MD Dr Omnia Sherif, MD Ophthalmology Consultants, Elite Medical & Surgical Center Riyadh -KSA.

What now, when Presbyopia sets in? Minoru Tomita, MD, PhD Executive Director Shinagawa LASIK Center, Tokyo, JAPAN

Active Cyclotorsion Error Correction During LASIK for Myopia and Myopic Astigmatism With the NIDEK EC-5000 CX III Laser

LASIK Surgery. One Use-Plus. The Moria Option for SBK

Excimer Laser Eye Surgery

Corneal Collagen Cross-Linking (CXL) With Riboflavin

How LasikPlus can help you

Transcription:

FIRST EXPERIENCE WITH THE ZEISS FEMTOSECOND SYSTEM IN CONJUNC- TION WITH THE MEL 80 IN THE US JON DISHLER, MD DENVER, COLORADO, USA INTRODUCTION AND STUDY OBJECTIVES This article summarizes the first US experience with the FDA-approved MEL 80 TM and the 510(k) cleared VisuMax femtosecond laser system as presented at the ASCRS 2007 during the Carl Zeiss Meditec Innovation Symposium. The general objective of this study was to determine the surgical outcomes of patients undergoing myopic LASIK using both the VisuMax laser keratome to create corneal flaps and the MEL 80 TM excimer laser to perform the refractive correction, within the FDA-approved range, as part of an integral LASIK procedure. It is also very important to analyze how accurately the system is able to create the flaps. Hence it was an objective of this study to determine corneal flap thickness using the Visante TM OCT. Especially flap thickness issues are widely discussed to be of major interest due to safety considerations. Thinner flaps weaken the cornea less during the LASIK procedure. Therefore, thinner flaps are safer for patients because of the decreased risk of postoperative ectasia. Moreover, the greater the residual bed thickness due to thin flaps, the better is the chance that if a patient does need retreatment it can be accomplished. Another objective is to report possible adverse events and complications associated with the combined use of the VisuMax laser keratome and the MEL 80 TM excimer laser system in the myopic LASIK procedure. STUDY DESIGN AND SUBJECT DEMOGRAPHICS All treatments have been performed at one clinical site, the Dishler Laser Institute, Denver, Colorado, USA and were completed during March 2007. One surgeon (Jon Dishler) operated on 62 eyes of 32 consecutive patients undergoing initial myopic LASIK. The approved myopic LASIK treatment range was up to 7.00 D sphere, 3.00 D cylinder and 8.00 D manifest refraction spherical equivalent (MRSE). The VisuMax femtosecond laser keratome LASIK flaps created were of 100 µm, 110 µm, or 120 µm planned flap thickness. Initially, a 120 micron depth flap was cut, then 110 µm and 100 µm flaps were created. Visante TM scans were performed preoperatively and postoperatively to determine corneal flap thickness. Study end points were defined to cover the base parameters required for primary evaluation, i.e. predictability, safety and effectiveness. The following safety and effectiveness parameters were applied. The percentage of eyes with uncorrected visual acuity (UCVA) of 20/20 or better and 20/40 or better was analyzed to account for the effectiveness of the procedure and the number of eyes within ±0.50 D and ±1.00 D of the intended correction ranges for predictability. For safety, the number of eyes with a loss of more than 2 lines of best spectacle corrected visual acuity (BSCVA) and the number of eyes with more than 2.0 D of induced manifest refractive astigmatism were counted. Mean corneal flap thickness as measured by the Visante TM OCT compared to the intended flap

thickness for the VisuMax treatment is also a very important evaluation criterion for safety. Patients were screened for corneal pathologies by complete ocular examinations. Patients with ocular pathologies like severe dry eye, keratoconus, corneal scars, corneal dystrophies, other ocular diseases with a certain history, and previous ocular surgery were excluded. With 14 (44 %) male and 18 (56 %) female patients, the gender distribution of the recruited patients was uniformly distributed. Further details of the subject demographics of the 62 eyes are summarized in Table 1. When programming the VisuMax laser to create a 100 µm flap, the mean measured thickness (13 eyes) was 97.6 µm at seven days. Note the small range of measurements observed from 95 to 101 µm. Data gathered at one month on seven eyes was virtually the same, with a mean flap thickness of 98.9 µm. Similar good results were found for programmed flap thicknesses of 110 µm and 120 µm, where 22 patients and 9 patients were measured, respectively, after 7 days. For the investigated flap thicknesses, very good accuracy of the mean post-surgery flap thickness was Pre-OP Mean Range Age 38 y 24 y 55 y Sphere 2.92 D ( 0.25 to 5.75) D Cylinder 0.85 D (0.00 to 2.75) D MRSE 3.33 D ( 0.88 to 6.13) D Table 1: Pre operative subject demographic for the Zeiss VisuMax MEL 80 TM LASIK study, 62 eyes Keratome N Mean SD Range Intralase 110 µm 20 125.9 15.2 106 160 Hansatome 200 µm 9 171.3 9.5 146 188 Moria 130 µm 4 187.2 16.4 168 210 Table 3: Flap thickness results measured 7 days after LASIK surgery using the Intralase femtosecond flap cutter, the Hansatome and Moria microkeratomes measured with Visante TM OCT RESULTS AND FINDINGS Flap Thickness Initially, the focus was on the flap thickness as one of the most important clinical aspects related to flap parameters. We anticipated improved accuracy of the flap thickness for femtosecond flaps made with the VisuMax laser keratome. The findings at 7 days and 1 month postoperatively are summarized in Table 2. The flap thickness results shown were determined by averaging three Visante TM measurements for each flap measured. noted with just a few microns below the programmed thickness. Concerning the range of flap thicknesses, we did not find flaps that were off more than 6 µm for 120 µm. It should be noted that the accuracy of the Visante TM OCT to measure corneal flap thickness is on the order of 10 µm. The data from this study was compared with data gathered during the first Visante TM pachymetry and flap thickness study that was submitted to the FDA for premarket clearance. The FDA 510(k) Visante TM study involved three investigators who each used a different Programmed Thickness 7 days post-operatively 1 month post-operatively N Mean Range N Mean Range 100 microns 13 97.6 95 101 7 98.9 97 102 110 microns 22 108.0 104 113 9 110.0 108 112 120 microns 9 117.8 114 122 8 112.8 104 119 Table 2: Flap thickness results measured 7 days and 1 month after myopic LASIK surgery using the VisuMax laser for flap cutting and the MEL 80 TM for the refractive correction measured with Visante TM OCT 2

Figure 1: Predictability of VisuMax MEL 80 combined treatments after 7 days post-surgery. Achieved manifest refraction spherical equivalent (MRSE) versus attempted MRSE is shown for 59 eyes. Figure 2: Refractive outcome of VisuMax MEL 80 TM combined treatments after 7 days and 1 month post-surgery. Percentage of the eyes within the attempted manifest refraction spherical equivalent sectioned in the intervals as given on the abscissa for 59 eyes after 7 days and 40 eyes 1 month post-surgery. keratome (one used IntraLase, one used Hansatome, and one used Moria). The flap thickness observed during the first study at 7 days is provided in Table 3 below. Note that mean flap thickness for these three keratomes was not as close to the target flap thickness as the VisuMax findings noted above. The mean flap thickness for 20 eyes was 125.9 for the Intralase femtosecond laser system when a flap thickness of 110 µm was targeted. Note the wide range of measurements from 106 to 160 µm. For the Hansatome microkeratome, mean flap thickness was 171.3 µm for nine eyes at 7 days when the targeted thickness was 200 µm, with a range of 146 to 188 µm. For the Moria microkeratome, mean flap thickness was 187.2 µm for 4 eyes at 7 days when the targeted thickness was 130 µm, with a range of 168 to 210 µm. As can be seen from these data, the range of values obtained is much greater for the IntraLase, Hansatome, and Moria keratomes than the VisuMax femtosecond laser. We noted a large range of findings for measured flap thickness during the Intralase measurements. Although there seems to be a reasonable lower limit (106 µm) for measured flap thicknesses below the programmed ones (110 µm), a much extended upper range of measured flaps (160 µm) above the programmed thickness appeared. This higher measurement potentially could increase the risk of surgical complications such as ectasia. Our data is more consistent with findings reported in the literature, see (4) for Intralase studies or (1, 2, 3) for Hansatome and Moria microkeratome studies respectively. In conclusion, the VisuMax system generates more accurate flaps compared to the IntraLase femtosecond laser and Hansatome and Moria mechanical microkeratome. The small range of measured flap thickness for the VisuMax system (104 µm to 113 µm for 110 µm programmed flap thickness) compared to the Intralase system (106 µm to 160 µm for 110 µm programmed flap thickness) appears to be an important finding for increased safety in daily clinical practice. Moreover, we on average gain residual corneal thickness as the VisuMax provides flap thickness upper limits well below the Intralase system. This is very important in case of potential retreatments and reduces the risk of ectasia. The increased accuracy is in part due to the calibration of each disposable contact glass immediately before the procedure, and this is unique to the Zeiss femtosecond laser system. It might also be due in part to the curved contact glass, which allows for flap cuts in the cornea in a more anatomically correct manner than other microkeratomes, whether blade- or laser-based.

Figure 3: Efficacy of VisuMax MEL 80 TM combined treatments at day one and after 7 days and 1 month post-surgery. Percentage of the eyes with uncorrected (Snellen) visual acuity for 55 eyes at day 1, 58 eyes after 7 days and 42 eyes after 1 month. Figure 4: Safety of VisuMax MEL 80 TM combined treatments after 7 days and 1 month post-surgery. Percentage of the eyes with change in (Snellen) best spectacle corrected visual acuity for 59 eyes after 7 days and 38 eyes after 1 month. Refractive outcome In general, we found accurate refractive outcomes reproducing the excellent results of the FDA clinical trial that led to approval of the MEL 80 TM for myopia. The predictability in particular is very high for treatments using the VisuMax for flap cutting followed by MEL 80 TM refractive corrections. This is shown in Figure 1 where the achieved manifest refraction spherical equivalent (MRSE) versus the attempted MRSE at 7 days post-surgery is provided. All eyes are very tightly clustered around ideal attempted versus achieved line without outliers beyond the ± 1 diopter interval. Although not shown here, changes from 7 days to 1 month postoperatively were minor, demonstrating the rapid stability of results of LASIK procedures with VisuMax femtosecond flap creation combined with the MEL 80 TM. Figure 2 shows the accuracy of refractive outcome for VisuMax MEL 80 TM combined treatments after 7 days and 1 month post-surgery. Over 90 % of the eyes are within plus or minus half a diopter within the attempted manifest refraction spherical equivalent 7 days post-surgery (92 %) and 1 month postsurgery (93 %). Virtually all patients are within the one-diopter interval. Efficacy for VisuMax MEL 80 TM combined treatments at day 1 and after 7 days and 1 month post-surgery is shown in Figure 3. Given is the percentage of eyes with uncorrected Snellen visual acuity from visual acuity 20/15 down to 20/40 or worse for 55 eyes at day 1, 58 eyes after 7 days and 42 eyes after 1 month. Patients were not challenged during their examination to read at 20/15 or better vision because we intended to get realistic data comparable to what we found in other studies. Nevertheless, cumulatively 100 % of eyes were 20/25 or better 1 month post-surgery and about 85 % or 36 of 42 eyes were 20/20 or better. This is a very good result. Best spectacle corrected visual acuity (BSCVA) changes pre- to post-surgery (see Figure 4) demonstrate the high level of safety when using the VisuMax for flap cutting followed by the MEL 80 TM refractive correction approach. 95 % of all eyes were unchanged or gained one line after 1 month post-surgery. Only 5 % of or two eyes lost one line but no eye lost two or more lines after 1 month follow-up. 4

Surgical and postoperative complications and other aspects Femtosecond flap cutting using VisuMax was a new approach for us. Of importance were findings related to adverse events and surgical or postoperative complications. Not very much can be reported in this respect. The only surgical complications at all out of 62 eyes treated related to suction loss in two cases. One suction loss appeared in the very beginning of the procedure. We simply placed the suction back on, and finished treatment without any further complication. In the other case, the patient moved after most of the cut was made but before the sidecut had been completed. Following the company recommendations, we simply replaced the contact glass, and did the sidecut only. That flap lifted up perfectly and the case was uneventful. In the course of MEL 80 TM refractive correction, following the flap cut with VisuMax, we had no surgical complication and excellent visual result. This points out the added safety of femtosecond flap creation. In case of a suction loss that can occur with any microkeratome, what might be a significant complication, became an insignificant event for the VisuMax. In Table 4, we summarized our findings related to postoperative complications. We had virtually no significant complications except 2 dry eyes out of 60 eyes. Two cases of corneal edema between one week and one month resolved subsequently and one patient complained about temporary light sensitivity. CONCLUSION The Carl Zeiss Meditec VisuMax laser keratome and MEL 80 TM excimer laser system as part of the LASIK procedure provide safe, predictable, stable, and highest quality refractive outcomes, with a fast visual recovery. Surgical and postoperative complication rate was extremely low and no adverse events appeared during this study. Flap quality was excellent with the highest accuracy ever observed so far by us when compared to another femtosecond laser system and other conventional mechanical microkeratomes. Initial clinical results were excellent with rapid stabilization of excellent visual acuity and no significant complications were experienced. REFERENCES 1. Taneri S. Laser in situ keratomileusis flap thickness using the Hansatome microkeratome with zero compression heads. J Cataract Refract Surg 2006;72-77. 2. Kezirian GM, Stonecipher KG. Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis. J Cataract Refract Surg 2004;804-811. 3. Solomon KD, Donnenfeld E, Sandoval H, et al. Flap thickness accuracy: Comparison of 6 microkeratome models. J Cataract Refract Surg 2004;964-977. 4. Binder PS. Flap dimensions created with the IntraLase FS laser. J Cataract Refract Surg 2004;26-32. Postoperative complications, 60 eyes Quantity Corneal edema between one week and one month after the procedure 2 Increase IOP 4 Permanent plug for significant SPK 2 Transient light sensitivity syndrome 1 D L K 0 Table 4: Summary table of postoperative complications related to VisuMax MEL 80 TM combined treatments. 5

DS No.: 000000-1508-679 Specifications subject to change. Printed in Germany. Printed on environment-friendly paper, bleached without the use of chlorine. P UBLICIS X/07 Carl Zeiss Meditec AG Goeschwitzer Str. 51 52 07745 Jena GERMANY Phone: +49 36 41 22 03 33 Fax: +49 36 41 22 02 82 info@meditec.zeiss.com www.meditec.zeiss.com Carl Zeiss Meditec Inc. 5160 Hacienda Drive Dublin, CA 94568 USA Phone: +1 925 557 4100 Fax: +1 925 557 4101 info@meditec.zeiss.com www.meditec.zeiss.com