Residential Deck Safety, Construction, and Repair



Similar documents
Residential Decks. Planning and Development Services Department

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Uncovered Decks & Porches

POST AND FRAME STRUCTURES (Pole Barns)

Typical Deck Details

Patio Covers / Carports

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

Timber Decks. Technical Note. March 2007

Chapter 3 Pre-Installation, Foundations and Piers

COMMONLY USED RESIDENTIAL BUILDING CODES

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Basic Requirements for Residential Plan Review _

STANDARD OPEN PATIO COVER

RESIDENTIAL WOOD DECKS

Chapter 6 ROOF-CEILING SYSTEMS

Mark Cramer Inspection Services, Inc.

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

COMMONLY USED RESIDENTIAL BUILDING CODES

Mobile Home Pre-Inspection Checklist

I N T E R N A T I O N A L R E S I D E N T I A L CO D E


STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

TYPICAL PATIO COVERS 111

6 RETROFITTING POST & PIER HOUSES

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

How to secure your property after a disaster

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Wood Projects Outdoors. Post Hole Specifications. Deck Span Tables. Eakes.com

The Homeowner s Building Application Checklist for Constructing a Residential Sundeck

ATI Evaluation Service A Division of Architectural Testing Certification Services

March 14, Installation of Bay, Bow and Garden Windows

PRESCRIPTIVE RESIDENTIAL DECK CONSTRUCTION GUIDE. decking guard. rim joist joists

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Residential Plan Routing Information

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Building Construction. Lightweight construction. Conventional Construction

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Uniform Construction Code (UCC) Manufactured Homes. Modular Homes. Building Permit Application Package

Building Code Clarifications - 7. Fire Resistance

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

BUILDING PERMIT SPECIFICATIONS

Page & Turnbull imagining change in historic environments through design, research, and technology

Wisconsin Building Products Evaluation

Residential Foundations and Basements

PDmB, Inc. Definitions

The replacement or modification of existing windows shall comply with the following requirements:

Certification: Building Plans Examiner. Exam ID: B3

Guidelines for Earthquake Bracing Residential Water Heaters

MANUFACTURED HOME INSTALLATION FOR PERMANENT FOUNDATIONS (TRANSVERSE FLOORS) (SUPPLEMENT TO MANUFACTURED HOME INSTALLATION MANUAL)

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

CALIFORNIA BUILDING CODE

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Mason County Building Department

TOWNSHIP OF TOMS RIVER ZONING OFFICE DECK CONSTRUCTION

OPTIONAL INFORMATION GUARDING FLOORS, STAIRS, AND OTHER OPENINGS SELF INSPECTION CHECKLIST

CLACKAMAS COUNTY DEPARTMENT OF TRANSPORTATION AND DEVELOPMENT BUILDING CODES DIVISION R E S I D E N T I A L C O D E S U M M A R Y

Technical Assignment 2 TABLE OF CONTENTS

Sample Drawing Package for One and Two Family Dwelling Applications

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

Number of Sides Required to Have a Handrail

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

PERGOLAS AND CARPORTS

Detailing of Reinforcment in Concrete Structures

Guidelines for Earthquake Bracing of Residential Water Heaters

PUMP JACK SYSTEM AND ACCESSORIES

Simplified Steel Stair Design for Commercial and Institutional Buildings

Attached/Detached Patio Cover/Carport

MANUFACTURED HOUSING USED AS DWELLINGS

Superform Products Ltd.

One-third of all fatalities in the U.S. construction

CHAPTER 6 CONSTRUCTION TYPES

MUNICODE SERVICES LTD.

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION

Solar Panel Installations

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

EAST LYME HIGH SCHOOL

8/18/14. Introduction to. Framing. Terminology and Concepts

INFORMATION BULLETIN NO.

Featuring TJ Rim Board and TimberStrand LSL

Structural Failures Cost Lives and Time

SINGLE-FAMILY EARTHQUAKE (SEISMIC) RETROFITS

Development Services City of Lawrence, KS

For the purposes of this Part, the following words shall have the following meanings:

WorkSafe Guidance Document FALL PROTECTION IN RESIDENTIAL CONSTRUCTION

Handling, Erection and Bracing of Wood Trusses

Transcription:

Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the City municipal code Title 19. Informational handouts should not be used as substitute for actual codes or applications and do not provide comprehensive structural design for every conceivable condition. Prior to starting any development project, it is the applicant s responsibility to obtain a building permit for any and all improvements requiring such*. It is recommended that all decks be inspected annually either by the homeowner or a professional inspector. The North American Deck and Railing Association and other agencies have inspection checklists available to help with public awareness for deck safety. *All newly constructed, altered or replaced decks are required to have a building permit Exceptions: Residential Deck Safety, Construction, and Repair Direct replacement of part of the deck (not replacement of entire deck) without modification of structural elements and if total cost, labor and materials does not exceed $7,500.00. Freestanding decks not higher than 30 inches from adjacent grades within 3 of deck. Note: Setback and zoning restrictions may apply to some situations; you should ensure that any non-permitted deck or structure is not in violation of any zoning or local covenant requirements. There are two types of decks: 1. Freestanding a deck that supports itself and is not attached to any other structure. 2. Attached a deck that is attached to another structure by use of a ledger or other approved method. Application Materials and Review: Submit an application, two sets of plans and specifications for review; plans are reviewed in the order they are received. All plans must include the following: Site plan of the entire lot including existing building, location of deck or patio, and distance to each property line. (Zoning setback/distance from property line requirements as defined in CBJ Title 49 apply to all decks) An elevation view showing the lowest footing to the highest point of work (guardrail or roof). Foundation plan showing type, size, rebar schedule and location. A plan view showing type of framing material and all dimensions internal and external, to include species of wood, member spans, measurements of piers, beams, joists, girders, rafters and decking. A detail of connection to the existing building, connections to posts, girders and ledgers including fasteners, hangers and flashing. Computer drawings are acceptable as long as they include all of the above requirements. Page 1 of 6

Materials All materials used in decks must be approved for exterior use (full exposure to weather). Lumber must be pressure preservative treated or of an approved species that is naturally resistant to decay. Field cut ends, notches and drilled holes of pressure treated wood shall be retreated in the field in accordance with AWPA M4. Fasteners (screws, nails, hangers & brackets) must be stainless steel, hot dipped galvanized, silicon bronze, copper, ceramic coated or other approved fasteners for exterior use and or use with preservative treated lumber. Load Capacity & Design Standard residential deck framing is required to sustain a 50 lb live load and 10 lb dead load for all walking surfaces (dead loads may vary depending on type of materials). Beam size, joist size and span lengths must meet the minimum requirements listed in the 2006 IRC & 2006 IBC. Any design submitted that does not meet the criteria may require stamped approval of a State licensed engineer. Footings / Foundations For decks that require footings, the footings must be sized to carry the applied loads and be no less than 32 inches below the grade when attached to another structure. Example: a 12 x12 footer, 10 thick with two #4 rebar each way to form a square supporting a grade level deck, placed where the soil conditions are known to have a bearing capacity of 2,000 PSF or better should support approximately 20 square feet of deck. For decks with a second story or roofing system the footing size will need to be increased accordingly. Concrete columns (Sono-tubes, etc.) used on footers must be anchored to the footers with a minimum of one #4 rebar that extends up to within 7 to the top of column and have a 90deg hook in the footer. s that sit directly onto concrete must be restrained from lateral displacement by approved connection. s approved to extend below grade and bear onto a footing may be restrained by the back filled earth around it. Approved footing and foundation types for residential decks Formed Pad & Pier Formed Pier Pre-cast foundation systems Pier Block for freestanding non-frost protected decks less than 30 in height only. Grade All frost protected deck foundations must extend 32 deep to undisturbed nonexpansive soils or engineered fill. These dimensions are dictated by the size of the deck and the load it supports. NOTE: Deck footings that are on or adjacent to slops steeper than 1 in 3 have additional requirements per IRC R4031.7 Typical rebar minimum requirements for deck footings are 2 #4 bars equally spaced each way 3 clearance to bottom of footer, vertical rebar minimum 1 #4 with typical hook extending from footer up into pier or column within 7 to top. Page 2 of 6

s & Bracing Wood columns and posts shall not be less in nominal size than 4 x4 and steel columns shall not be less than 3 in diameter standard pipe or approved equivalent. s that support decks over 24 in height and roof structures must have bracing to resist lateral movement. Bracing may be accomplished by any of the methods described below or other bracing methods that meet standard construction or engineered design. Fasteners used to connect bracing to deck must be lag bolts, through bolts or other approved mechanical connection. Gusset or knee bracing Cross bracing or X bracing Gusset bracing dimension must equal 1/3 the post height from grade or 24 which ever is greater, placed at a 45 deg angle. s must bear directly on approved post base connectors or be embedded directly into the foundation system. Diagonal bracing applied to the underside of the joists, minimum 2 x 6 fastened with two 3 ½ 16d galvanized nails or approved equivalent into each joist. House Ledger Page 3 of 6

Girders & Joists The ends of each joist, beam, or girder shall not have less than 1.5 inches of bearing on wood or metal and not less than 3 inches on masonry, concrete or by the use of approved hangers. Deck joists, beams and girders must be sized and spaced to hold a 50lb per sq. foot tributary live load and a 10 lb per sq. foot dead load. Girder Beam or Joist o o o o o o o o o o o o o o o When girders or beams sit on top of posts, an approved mechanical connection must be made on both sides. Girder Beam or Joist Metal connectors or wood gusset plates fastened to both post and beam/girder. Joist Approved joist hangers for connection to girder or ledger. Solid blocking between joists at cantilevers and bearing points Uplift ties minimum 4ft on center Beam Girder or Beam Girder or Beam Lag or through bolts with washers. Full Bearing Not Allowed! Correct! Page 4 of 6

Ledger Connection When an exterior wall is used to support a deck, it must be attached by a minimum of two rows of 1/2 minimum diameter galvanized lag screws and washers. They must penetrate a minimum of 1¾ inches into a wooden header band or rim joist which must bear directly on foundation wall or wall framing. Through bolting or other approved alternate fasteners* may be substituted. If there is no header, band or rim joist, fasteners must connect to the wall framing or foundation. The lag screws or bolts shall be placed 2 in from the bottom or top of the deck ledgers and between 2 and 5 in from the ends. The lag screws or bolts shall be staggered from the top to the bottom along the horizontal run of the deck ledger. The lag screws or bolts must be sized and spaced to resist both vertical and lateral loads, this connection must be available for inspection; if it is not, this method of support is not permitted and the deck must be self supported. Existing exterior coverings (siding) must be removed so that the ledger connects directly to the rim joist or wall framing. The ledger must be continuously flashed and sealed to prevent water from entering the wall assembly. Ledgers that attach to cantilevered floor systems must be approved and stamped by a licensed AK P.E. or be constructed according to an approved listed design, it is the builder s responsibility to provide these calculations for review. *Alternate ledger fasteners must be labeled and listed for such use. It is the applicant s responsibility to provide product documentation that includes installation procedures, spacing and pattern requirements that apply to the loading values of the deck. Interior wall framing Ledger cut view Exterior wall covering must be removed from behind ledger and flashing. Rim or band joist Ledger flashing Behind and over the ledger for full length Deck joist Interior floor joist Joist hanger Load bearing wall or foundation. Lag screws or through bolts w/washers Rim joist must sit directly on load bearing framing or foundation system. Exterior wall Wall framing not shown for clarity Page 5 of 6

Stairs /Guardrails / Handrails All decks that have walking surfaces higher than 30 above grade within 36 of deck must have a guardrail no less than 36 inches in height. The guard rail must be mechanically connected to the deck and or house to resist a 200lb lateral load in either direction. The intermediate/ornamental closures or pickets must be spaced less than 4 inches apart so that a 4 sphere cannot pass between at any point. One compliant handrail is required on all sets of stairs that have 4 or more risers. Handrails must be 34 minimum to 38 maximum high as measured from the tread plane at the nosing. Handrail grip size must be Type 1 or Type 2 as described on CBJ handout for Residential Graspable handrails or 2006 International Residential Code section R311.5.6.3 The maximum riser height shall be 7¾ inches, risers height s may not vary more that 3/8 of and inch from the smallest to the largest. The Minimum run depth is 10 inches, tread depths may not vary more than 3/8 of an inch from the shortest to the longest. All stairs must have a floor or landing at the top and the bottom, the width of each landing shall not be less than the stairway served. Every landing shall have a minimum dimension of 36 inches measured in the direction of travel. Open risers on stairs with a total rise of more than 30-inches must be constructed so that the opening between risers is less than 4. LESS than 4 Guardrail minimum 36 tall at deck & landing, minimum 34 tall at stairs measured from tread nosing. LESS than 4 3/8 at side of stairs One grippable handrail required 34 to 38 high measured form tread nosing, handrail must return to guardrail at top and bottom. Max stair rise 7 ¾ Minimum stair run 10 Guard required if over 30 high. Intermediate landings required every 12 of vertical rise at stairs. Grade LESS than 4 between open risers NOTE: If the vertical intermediate rails attach to outside of the deck they must be pre-drilled and fastened with screws, lag bolts or other approved mechanical fastener not subject to withdrawal. Stair requirements, covered by 2006 International Residential Code sections R311 and R312. Page 6 of 6