2 Single Use Only. Guidance System Manual. Part Art. Part Science. All Orthodontics.



Similar documents
ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

Microimplant Anchorage in Orthodontics

Table of Contents Section 6 Table of Contents

Ideal treatment of the impaired

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

IMPLANT DENTISTRY EXAM BANK

Implants in your Laboratory: Abutment Design

Prosthodontist s Perspective

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction


Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

Universal Screw Removal System (USR)

More than a fixed rehabilitation.

BASIC ORTHODONTICS. And why we believe in THE TIP EDGE TECHNIQUE (Differential Straight Arch)

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

FABRICATING CUSTOM ABUTMENTS

Implant Parts. A Radford Heath Guide 1

Retractable Screen. Replacement Screen Instructions

Implant Bar Overdenture Utilizing Locator Attachments

Straumann Bone Level Tapered Implant Peer-to-peer communication

Installation Instructions

Orthodontic mini-implants, or temporary anchorage devices

JCO INTERVIEWS Dr. Rohit C.L. Sachdeva on A Total Orthodontic Care Solution Enabled by Breakthrough Technology

Molar Uprighting Dr. Margherita Santoro Division of Orthodontics School of Dental and Oral surgery. Consequences of tooth loss.

Accelerated Patient Rehabilitation

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

Posterior Referencing. Surgical Technique

your talent. our technology. the perfect fit.

Implant Systems MAX LOGIC MONO. Today s name in tomorrow s implant technology

CLEAR COLLECTION FOR CLEAR ALIGNERS CLEAR SOLUTIONS FOR CUSTOMIZED EFFICIENCY

Restorative Guidelines

Use of variable torque brackets to enhance treatment outcomes

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

SURGICAL MANUAL. Step By Step Techniques

Congenital absence of mandibular second premolars

Unpacking, Installation, and Customization

Universal Crown and Bridge Preparation

Nobel Clinician - Quick Guide

ECM-D70T / ECM-D70T1.5

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Implant systems warranty

Press Abutment Solutions

Wanda Technology Inc. Side Post Aluminum Umbrella OWNER S MANUAL

COMPACT ELITE MAT CUTTER

How To Use Nobelbiocare'S Integrated Treatment Workflow

ROTOR LOADER OWNER S MANUAL

Say Hello to Your Precision Cooker

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Guidance for implant removal. Straumann Dental Implant System

Dental Updates. Excerpted Article Why Implant Screws Loosen Part 1. Richard Erickson, MS, DDS

CDT 2015 Code Change Summary New codes effective 1/1/2015

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

Dentalworkers JOB DESCRIPTIONS Great Team Members make your Office function!

Fixing Dental Implant Component Failure and Fracture: Retrieving the Fractured Implant Abutment Screw. Charles A. Mastrovich, DDS

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

RZ Guardrail System Installation Manual

2-Way Wireless Indoor Siren Installation Guide

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

MEDICAID DENTAL PROGRAMS CODING, POLICY AND RELATED FEE REVISION INFORMATION

Installation Instructions: (Part # SB76880) XRC Armor Front Fender Kit

PATHWAY Classic Series with Handrails Portable Wheelchair Ramp INSTRUCTIONS FOR USE 6428 REV A

Regular C/X Prosthetics. Prosthetics

Orthodontic miniscrews have become increasingly

Creativity in Dental Implants

ABSTRACT INTRODUCTION. Facial Esthetics. Dental Esthetics

Table of Contents WARNING SYMBOLS AND DEFINITIONS

TRI-CAM Implant System

Bitewing Radiography B.E. DIXON. B.D.S., M.Sc., D.P.D.S.

Dental Morelli Ltda.


Healing Abutment Selection. Perio Implant Part I. Implant Surface Characteristics. Single Tooth Restorations. Credit and Thanks for Lecture Material

AZEK Rail Install Guide

About this Manual. Support for Your Product

Super Slider ADJUSTABLE FROM Model #HD26229

Working relationship between Orthodontic Auxiliaries and Dentists/Dental Specialists Practice Standard

Chart 1. Chart 2. How to Use the Following Charts. Be sure to follow the legal requirements to perform dental radiographic procedures.

Humana Health Plans of Florida. Important:

One Abutment - One Time

MTV-FS1 / FS1T / FSB375

Scotchgard Multi-Layer Protective Film 1004

CHAPTER 12 SURVEY LINES. portion of the tooth is undercut to the path of placement of the denture. DEFINITIONS

SCD Case Study. Treatment Considerations for Implant Rehabilitation

Destiny Shower Enclosure Installation Instructions

TERMS AND CONDITIONS

ROUTER TABLE INSERT ASSEMBLY AND OPERATING INSTRUCTIONS

SELLING TERMS AND CONDITIONS

Global Water Instrumentation, Inc.


Installing the Sno-free Standing Seam System for Metal Roofs

Order of Treatment STEP-BY-STEP INSTRUCTIONS TO PLACE LOCATOR ATTACHMENTS

Procedures & Products Powered by Procera. All-on-4

Full Crown Module: Learner Level 3

TABLE OF CONTENTS 11.0 WARRANTY

General Explanation of the Straight Wire Appliance in the Treatment of Young People and Adults Publication for the Journal du Dentiste in Belgium

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

Transcription:

Distributed by: DENTSPLY INTERNATIONAL DENTSPLY GAC Intl. 355 Knickerbocker Avenue Bohemia, NY 11716 Tel: 1-888-422-4685 Outside US: 1-631-419-1700 www.gacintl.com 2 Single Use Only www.infinitas-miniimplant.com/gac Infinitas Mini Implant is a Registered Trademark of DB Orthodontics Limited Rx Only 0473 Class 2a and 2b medical devices Intertek Certification Services Limited Davy Avenue Knowhill Milton Keynes MKS 8NL Manufactured by: DB Orthodontics Ryefield Way Silsden West Yorkshire BD20 OEF United Kingdom Tel: + 44 [0] 1535 656 999 sales@dbortho.com www.dbortho.com Made in England Guidance System Manual 2011 DENTSPLY GAC Intl. All Rights Reserved. DFU41 2011-8

WARRANTY & CONTACT INFORMATION Quality Control DB Orthodontics operates a Quality Management System in accordance with ISO 13485. This encompasses a batch/lot control system for full traceability of all medical devices and equipment sold by DB Orthodontics. Customers of DB Orthodontics should be reminded to retain product information for medical devices supplied by DB Orthodontics. Information should include batch/lot number and expiry date which would be required should the need arise to return the product or in the case of a product recall. Packing DB Orthodontics Infinitas mini implants are provided sterile. Infinitas mini implants are also provided non sterile together with dental instrumentation and components. Contact Information For troubleshooting and/or service, please contact your local DENTSPLY GAC sales representative or DENTSPLY GAC Customer Service Department directly at 1-888-GACINTL (422-4685) or 1-631-419-1700. Warranty DB Orthodontics warrants to the dental professional who purchases its products that all reasonable care has been taken in the choice of materials, method of manufacture, coating and packaging. DB Orthodontics shall not be liable for any incidental or consequential loss, damage or expense, directly or indirectly arising from the use of its products. The foregoing warranty, as conditioned and limited, is in lieu of and excludes all other warranties, whether expressed or implied, including but not limited to any implied warranties of merchantability or fitness-for-use, and of any other obligation on the part of the seller. DB Orthodontics neither assumes, nor authorizes any other person to assume for it any additional liability or responsibility in connection with its products. No agent, employee or representative of DB Orthodontics has any authority to bind DB Orthodontics to any affirmation, representation or warranty concerning its products and any such representation or warranty shall not be enforceable by the buyer. Liability under this warranty is limited to replacement of any defective materials, manufacture or packaging. Damage to any DB Orthodontics product through misuse, neglect, accident or failure to follow recommended procedures or instructions for use by the buyer or user voids any DB Orthodontics warranty. Product replacement under DB Orthodontics warranty shall be effected by promptly contacting DB Orthodontics at the phone numbers provided. Nothing in DB Orthodontics warranty shall be construed to extend the rights or remedies of a patient into whom a DB Orthodontics product is implanted. CAUTION: UK laws restrict the sale of any Infinitas product or device to licensed physicians, dentists or dental specialists. Use by any other person is strictly prohibited. 9

GUIDANCE KIT WHY CHOOSE INFINITAS? Infinitas Guidance Kit: KIT95-010-49R (Round Baseplates) / KIT95-010-49S (Square Baseplate) Product description and order information for individual components. Guidance Kit contains: 95-010-30 Infinitas Stent Analogue (packet of 5) 95-010-31 Infinitas Stent Abutment (packet of 5) 95-010-32 Infinitas Stent Guide Cylinder (packet of 5) 95-010-35 Analogue C/A Drill for Plaster Model (1 each) 95-010-36 Analogue S/T Drill for Plaster Model (1 each) 95-010-37 Analogue Lab Drill for Plaster Model (1 each) 95-010-38 Analogue Screwdriver (1 each) 95-010-40R or 95-010-40S Infinitas Baseplate - Round (packet of 5) 1.5mm Infinitas Baseplate - Square (packet of 5) 1.5mm 95-010-45 Infinitas Plastic Guidance kit box (Image shows Infinitas Guidance Kit KIT95-010-49S) Infinitas mini implant system from DB Orthodontics. The Simple, Yet Comprehensive, Orthodontic Mini Implant System for a Wide Variety of Anchorage Applications. DB Orthodontics mission is to provide the orthodontic profession around the world with the best mini implant system. We have strived for absolute perfection from the design stage to the manufacturing of the Infinitas Temporary Anchorage Device (TAD) System. We are continually evolving the Infinitas TAD System, working with leading orthodontic experts to ensure that our mini implants meet the highest standards expected by today s orthodontic profession. In essence, the Infinitas TAD System has been designed by an orthodontist, for orthodontists, so that precise, reliable bone anchorage can be achieved using as simple a clinical process as possible. The Infinitas TAD System has been designed with Dr. Richard Cousley who is a consultant orthodontist working in the UK hospital service and private practice. He has published papers and lectured widely on the technical aspects of bone anchorage, and developed the Infinitas mini implants system to overcome some of the limitations of existing mini implants, especially in terms of their lack of insertion precision and overly complex inventories. International patent pending. U.S. patent pending FDA Cleared for marketing in the US CE Marked 8 1

GUIDANCE KIT DIRECTIONS FOR USE MINI IMPLANT PLANNING AND STENT FABRICATION Indications For Use Contraindications Warnings For professional use only. Fig.10 Infinitas head with 0.021 x 0.025 wire. 1.7 Pre-form Attachments (optional) The Infinitas guidance system enables the orthodontist or dental technician to accurately fabricate wire attachments (e.g. 0.021 x 0.025 archwire) in advance of the clinical stage. In particular, if it is planned to provide indirect anchorage with a transpalatal arch then this can be made using the analogue(s) fitted in the patient s dental model. This may also include soldering bondable bonding bases to the wire. The Infinitas guidance kit is intended for use only with the Infinitas clinical kit and its related mini-implant insertion techniques. It does not replace the need for a full orthodontic diagnostic and treatment planning process. Precautions Adverse Reactions 2 Fig.9 Stent fitted to model allowing open visual access of insertion site. 7

MINI IMPLANT PLANNING AND STENT FABRICATION MINI IMPLANT PLANNING AND STENT FABRICATION 6 Fig.7a Model placed in pressure forming machine with guide cylinder in vertical position. Fig.7b Baseplate & cylinder after thermoforming. The baseplate now incorporates the guide cylinder and they are removed en masse from the model and abutment (Fig.7b). The baseplate s labial and lingual edges are trimmed, and the superficial end of the guide cylinder is opened by cutting through the covering baseplate layer. 1.6 Fabricate the Stent Baseplate Plaster separator (cold mold seal) is applied to the plaster model. A 1.5 mm thermoforming baseplate, such as the Infinitas baseplate which is available in round or square versions (95-010-40R or 95-010-40S) is placed on top of the assembled model abutment and guide cylinder components. It is then pressure-formed onto the model using a machine conventionally used for retainer fabrication. When placing the model into the pressure forming machine the guide cylinder should be in a vertical position (standing upright (Fig.7a), this helps to create a fold in the base plate material from the guidance cylinder to the palatal or buccal surface of the stent (see Fig.8). To help with removal of the stent from the plaster model it may be necessary to block out all undercuts. Fold Relieved Fig.8 Trimmed baseplate to form stent with both superficial end & fitting surface of guide cylinder relieved. The mini implant insertion site is exposed by relieving 3-4 mm of the fitting surface of the guide cylinder and adjacent baseplate (Fig.8). This provides open visual access of the insertion site without detracting from the positive guidance that the cylinder provides for the screwdriver. It also allows for removal of the stent from over the mini-implant head when the latter is not yet fully seated (during clinical insertion). Fig.1 X-rays used to determine place of insertion. Fig.2 Model with location mark. Step-By-Step Instructions 1.1 Determine the Insertion Details Using a Dental Model and Radiographs The optimum three-dimensional position for each Infinitas Mini Implant is determined using both plain radiographs (e.g. a panoramic tomograph or intra-oral views) and a plaster model of the dental arch. Ideally, the mini implant should be located where there is a maximum depth of cortical and cancellous bone, at the same time, avoiding structures such as adjacent dental roots, the gingival papilla, neurovascular tissues and nasal/maxillary cavities. This results in a balance between the following three parameters: 1) the topographical entry point of the implant 2) the angulation: antero-posterior (AP) angle of entry 3) the inclination: vertical angle of entry. For example, where a patient requires retraction of the anterior teeth into a first premolar space then the mini implant is commonly located buccally between the second premolar and first molar teeth in this quadrant. The insertion point and angles will be influenced by the position and morphology of the adjacent dental roots. The vertical level and angulation of the entry point affect the implant head s proximity to the gingiva and emergence angle. Maxillary buccal mini implants are typically inserted at 70-90 degrees to the bone surface. If a dental technician is to insert the mini implant analogue then the planned location and angulations should be prescribed in writing by the orthodontist, and ideally an ink mark placed on the dental model to indicate the exact insertion site. 3

MINI IMPLANT PLANNING AND STENT FABRICATION MINI IMPLANT PLANNING AND STENT FABRICATION Fig.3 Analogue drill in model. 1.2 Drill a Pilot Hole in the Model A pilot hole is drilled in the patient s dental model, using an analogue drill (95-010-35 or 95-010-36) in either a straight or contra-angle dental hand piece, or in a laboratory hand piece (95-010-37), to a depth of approximately 10 mm. It is critical that the drill is held at the correct angulations to ensure that the desired vertical and mesio-distal insertion angles are produced. This procedure is normally performed free hand, but if desired, a technician may use the analogue drill in a vertical pillar drill with the model set on an adjustable angled table (as described in Cousley RRJ, Parberry DJ. Surgical stents for accurate miniscrew insertion. Journal of Clinical Orthodontics 2006; 40: 412-417). Fig.5 Abutment over analogue. 1.4 Fit Abutment onto Analogue The Infinitas stent abutment (95-010-31) is manually fitted onto the head of the analogue. This acts as extension arm on the analogue and also makes it easier to double-check the insertion directions relative to the adjacent teeth. Fig.4 Analogue screw in place. 1.3 Place Mini Implant Analogue in Model The mini implant analogue (95-010-30) is inserted manually and fully seated using the analogue screwdriver (95-010-38) rotated in a clockwise direction. The location and angulations of the analogue should then be checked. If the 3D position of the analogue is dissimilar to the planned details then the analogue should be removed and the drilling and insertion process repeated. 1.5 Fit Guide Cylinder onto Analogue The Infinitas stent guide cylinder (95-010-32) is fitted by sliding it over the Infinitas abutment until it contacts the plaster model surface. Fig.6 Guidance cylinder over abutment. 4 5