DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

Similar documents
DIVISION: PLUMBING SECTION: INSTRUMENTATION AND CONTROL FOR PLUMBING REPORT HOLDER: XIAMEN SPRINT SHOWERS TECHNOLOGY CO. LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER: METALS BUILDING PRODUCTS/LATIUM USA TRADING, INC.

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

ICC-ES Evaluation Report

Engineering Specifications

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

REPORT HOLDER: JENWEST ENTERPRISES LLC, DBA ADVANCED CONNECTOR SYSTEMS 321 SOUTH 1240 WEST #15 LINDON, UTAH EVALUATION SUBJECT:

Section Four: Linings and Coatings

LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH BLACK & GALVANIZED STEEL PIPE

SURFACE PREPARATION STANDARDS

INDEX. Sec. No. Items Page Nos.

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

CITY OF LOS ANGELES CALIFORNIA

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

Effective Date: September 2015 Void After: September Product: Shielded Transition Couplings File No. 5794

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

81000 Series Aluminum Gate Valve Installation and Repair Manual

Wastewater Capital Projects Management Standard Construction Specification

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax:

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

SECTION POLYVINYL CHLORIDE (PVC) PIPE

Essentials Welding QA/QC Plan Sample

Amendment 1 Preliminary Engineering Report for the City of Salida

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

SECTION PRECAST CONCRETE UTILITY STRUCTURES

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

SECTION FIRE HYDRANTS

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SANITARY SEWER SPECIFICATIONS

CA-48 TECHNICAL SPECIFICATION

STANDARD SPECIFICATION SECTION STEEL PIPE, FUSION-BONDED EPOXY LINED AND COATED

SECTION DUCTILE IRON PIPE AND FITTINGS

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

Pictorial Surface Preparation Standards For Painting Steel Surfaces

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

City of San Diego, CWP Guidelines

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BORAL ROOFING

GENERAL RUBBER LINING PRINCIPLES

Corrosivity of Water Supplies

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Water Main Lining A Sustainable Alternative to Open Cut Replacement

STORED PRESSURE STAINLESS STEEL

Superior Pipe Restoration Solutions. Proven, state-of-the-art technology that saves money, time and inconvenience. belcopipe.com

REHABILITATING SMALL DIAMETER PIPING SYSTEMS. Author: Larry Gillanders ACE DuraFlo Systems ABSTRACT

Pipe Repair Products A complete selection for all types of pipe

Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

ASME Packaged Indirect Fired Water Heater

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

Chapter 7 Plumbing Connections

ASTM STANDARDS OFFER A SOLUTION TO THE PIPE COLOR CODE ISSUE Water Reuse in Texas 2012

Zero peel strength of acrylic pressure sensitive adhesive is at about 45 C (-50 F).

TECHNICAL DATA. Dry 122a. November 12, 2013

Where life interacts with infrastructure.

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

SECTION WATER STORAGE TANK PAINTING

HVAC Super Pro FAQ. Can HVAC SUPER PRO be used on both hard and soft copper and aluminum tubing?

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

Section C-1 Pipes and Fittings

SECTION STANDING SEAM METAL ROOFING

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

INSTALLATION MANUAL. Glass Vessel Sink. I toll free: I Kraus USA Inc.

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

The Original Carbon Fiber Reinforced Polymer System

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

Vogt Valves The Connection Bulletin for Extended Body Forged Steel Valves Welded Bonnet, Bolted Bonnet, Class 800 & Class 1500 CB 22

PROBLEM SOLVING FORUM

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

Rehabilitation of an Aging Concrete Reservoir Adit Tower

SECTION 1 GENERAL REQUIREMENTS

GUIDE TO WINDOW REPAIR & REPLACEMENT FOR HISTORIC PROPERTIES

Spandrel Glass Types and Recommendations

DIVISION 4300 STORM DRAINAGE

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Rubber Lining Application Manual Revision Date: September 1, Section 10: Pipe Lining Procedures Page: 10-1

TECHNICAL REQUIREMENTS AND SPECIFICATIONS

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

SUBMITTAL 10 FEET. Cast Iron Soil Pipe Products Hubless Pipe & Fittings HUBLESS PIPE 10 FEET*

SECTION FACILITY STORM DRAINAGE PIPING

Transcription:

0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted PMG 1057 Valid: 02/15 to 02/16 DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215 EVALUATION SUBJECT: CURAFLO ENGINEERED FLOW LINING SYSTEMS Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2015

ICC-ES PMG Listing PMG-1057 Effective Date: February 2015 This listing is subject to re-examination in one year. www.icc-es-pmg.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council CSI: DIVISION: 22 00 00 PLUMBING Section: 22 11 16 Domestic Water Piping Product certification system: The ICC-ES product certification system includes testing samples taken from the market or supplier s stock, or a combination of both, to verify compliance with applicable codes and standards. The system also involves factory inspections, and assessment and surveillance of the supplier s quality system. Product: Listee: CuraFlo Engineered Flow Lining Systems Uses epoxy to coat the interior of existing, cleaned galvanized steel pipe or copper rigid tube pressurized potable water supply systems CuraFlo IP LLC 4035 E. Oasis St. Mesa, Arizona 85215 Compliance with the following codes: 2015, 2012 and 2009 International Plumbing Code (IPC) 2015, 2012 and 2009 International Residential Code (IRC) 2012 and 2009 Uniform Plumbing Code (UPC)* *Uniform Plumbing Code is a copyrighted publication of the International Association of Plumbing and Mechanical Officials. Compliance with the following standards: Identification: ASTM F2831-2012, Standard Practice for Internal Non Structural Epoxy Barrier Coating Material Used In Rehabilitation of Metallic Pressurized Piping Systems ASTM D4541-2009e1, Standard Test Method for Pull-off Strength of Coatings Using Portable Adhesion Testers ICC-ES LC1008-2009, Listing Criteria for Internal Epoxy Barrier Pipe Coating Material for Water Supply Systems IAPMO IGC189-2008, Internal Pipe Epoxy Barrier Coating Material for Application in Pressurized (Closed) Water Piping Systems NSF/ANSI 61-2014, Drinking Water System Components Health Effects ANSI/AWWA C210-2008, Liquid-Epoxy Coating System for the Interior and Exterior of Steel Water Pipe Lines CuraPoxy: Each container bears a label marked Part A or Part B, with the manufacturer s name, the NSF 61 designation and the ICC-ES PMG listing mark. The label also has the batch number printed on it. Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this listing, or as to any product covered by the listing. Copyright 2015 Page 1 of 6

PMG-1057 Most Widely Accepted and Trusted Page 2 of 6 Installation: CuraPoxy LS: Each container bears a label marked Part A or Part B, with the manufacturer s name, the NSF 61 designation and the ICC-ES PMG listing mark. The label also has the batch number printed on it. Coated Piping or Rigid Tubing: At a maximum distance of 20 feet (6096 mm) along exposed coated pipe or tube, and at each fixture connection, a label is attached indicating the manufacturer s name, NSF-PW, the words This pipe has been lined with a CuraFlo epoxy and the ICC-ES PMG listing mark. The label includes a warning against using flame or heat when repairing any part of the piping system, and that any additions or alterations to the epoxy-lined piping system must be performed using mechanical fittings. CuraPoxy and CuraPoxy LS must be applied by authorized applicators trained by CuraFlo IP LLC. Existing piping or rigid tubes must be in good condition, with any cracks or leaks or visible signs of corrosion repaired. The following steps comprise the installation sequence: 1. The existing piping system is partially disassembled into separate sections, with flexible tube, valves and gasket connections removed. 2. Each section is air-dried and sandblasted clean in accordance with the manufacturer s published instructions. The cleaned surface, when viewed without magnification, must be in a shiny metal state and free of all visible oil, grease, dirt, mill scale, rust and previously applied coatings. Evenly dispersed, very light shadows, streaks and discolorations caused by stains of mill scale, rust and old coatings are permitted to remain on no more than 33 percent of the surface. Slight residues of rust and old coatings are permitted to be left in the craters of pits, if the original surface is pitted. Upon completion, this level of cleaning must be visually verified and recorded by the applicator. 3. Each section is then pressure-tested with air to 100 psi (689.5 kpa), to verify that the pipe has no holes, cracks or leaks. 4. Using proprietary measuring and application equipment provided by CuraFlo IP LLC, CuraPoxy epoxy is applied in one end of a pipe or tube section and forced by air pressure through the section. 5. After curing in accordance with the manufacturer s instructions, the CuraFlo applicator then reassembles the piping system and hydrostatically pressure tests to 120 psi (827 kpa) in the presence of the code official or the official s designated representative. 6. In the presence of the code official or designated representative, the CuraFlo applicator then conducts a flow test to verify the minimum flow rate to each fixture in accordance with Table 604.3 of the IPC. 7. Design: See Tables 1 4 for flow rates and pressure drop based on an average coating thickness of 0.010 inch (0.254 mm). Models: CuraPoxy and CuraPoxy LS are proprietary, two-part, mechanically mixed epoxy materials that are pneumatically applied to the interior of cleaned rigid-galvanized pipe or copper tube used to convey pressurized potable water. CuraPoxy and CuraPoxy LS are composed of a two-component epoxy (Part A and Part B) which meets the requirements of NSF 61, Section 5. The CuraFlo Engineered Flow Lining System is recognized for application on either galvanized steel pipe or copper tube from 1 / 2 inch to 4 inches (12.7 to 102 mm) in diameter. The installed minimum thickness of the coating must be 0.010 inch (0.254 mm) on all sizes, but the coating is certified for thicknesses up to 0.04 inch (1.0 mm). The CuraFlo Engineered Flow Lining System is not for application on gasket connections, valves or on flexible pressure pipe. Conditions of Listing: The CuraFlo Engineered Flow Lining System must be installed in accordance with this listing and the manufacturer s published installation instructions. In the event of a conflict, the instructions in this listing govern. In addition: 1. The existing piping system must be fabricated from rigid copper tubing or galvanized steel pipe materials in accordance with the applicable code. 2. All leaks must be repaired prior to coating in such a way so as to restore the affected sections to a code-complying condition. 3. The CuraPoxy and CuraPoxy LS used in the CuraFlo Engineered Flow Lining System are manufactured in Broken Arrow, Oklahoma, under a quality control program with annual surveillance inspections by ICC-ES.

PMG-1057 Most Widely Accepted and Trusted Page 3 of 6 TABLE 1 WATER PRESSURE LOSS IN 1 / 2 -INCH TYPE M COPPER PIPE

PMG-1057 Most Widely Accepted and Trusted Page 4 of 6 TABLE 2 WATER PRESSURE LOSS IN 3 / 4 -INCH TYPE M COPPER PIPE

PMG-1057 Most Widely Accepted and Trusted Page 5 of 6 TABLE 3 WATER PRESSURE LOSS IN 1/2 SCHEDULE 40

PMG-1057 Most Widely Accepted and Trusted Page 6 of 6 TABLE 4 WATER PRESSURE LOSS IN 3 / 4 INCH SCHEDULE 40 CARBON STEEL PIPE