grease, sediment and oil



Similar documents
CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION

National Precast Concrete Association

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Disposal of Fats, Oils, Grease and Food Waste Best Management Practice for Catering Outlets

Plumbing for retail food businesses

Biological Drain Maintenance Systems

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER

Bio-Clean. for Septic Systems. Tips for Using Bio-Clean. Page Index METRIC CONVERSIONS

Grease Trap Maintenance, Procedures and Cleaning Logs

Best Management Practices Fats, Oils, & Grease

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Septic System Care & Maintenance

SF15K SF05KSS, SF10KSS

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

40 ltr Domestic Grease Trap GTO ltr Commercial Grease Trap GTO2. Rotational Moulders providing State of the Art Product Design and Developement.

WHY A FATS, OILS AND GREASE PROGRAM. Employee Food Service Establishment Information Sheet INTRODUCTION

ALL YOU NEED TO KNOW...

Understanding Septic Tank Systems

Compliance Department

FOG PRETREATMENT INFORMATION. New London Public Utilities F.O.G. Program 120 Broad Street New London, CT 06320

Please also see 10 golden rules for correct Saniflo installation on

Getting the best from your urn

Drainage and Grease Management for the Commercial Kitchen

Looking after your Septic Tank System

CERTIFYING DRAINLAYER

SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.

Easy as instructions on how to install or replace the Cleanviro waterless urinal tablet

Manual contents includes:

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Help protect our special places by maintaining your septic tank

Guidelines for Precast Concrete Grease Interceptors

Installation Instructions

1. Description. 2. List of Accessories included A B C F G H

GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS AND INTERCEPTORS

Grease and Oil Wastes Problems andsolutions A grease trap is a device used for removing oil and grease from wastewaters. Grease traps perform this

Fats, Oils, and Grease Best Management Practices Manual

ALL PURPOSE CLEANER. Active Ingredients. Description. Advantages. Remarkable products from Nature's own laboratory

septic systems What is a Septic System? How does a Septic System Work?

CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673 MT. MAJOR HWY, ALTON, NH 03810

Jay R. Smith Mfg. Co.

In-Line Filters and Coalescers with Automatic Drains

REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE

.5.1 MAINTENANCE AND PERIODIC INSPECTION OF DRAINAGE SYSTEMS

ACO Building Drainage

1.2 How Does FOG Affect You? The City of Huntington Beach FOG Control Program.. 2

London Farm Kitchen Sinks

Grease 101. Why is Grease a Problem?

How do I clean my grease trap? Refer to Grease Trap and Interceptor Maintenance.

Grease Traps and Interceptors

Chill 4 Hole Bath Shower Mixer

Septic Tank Use & Maintenance Tips

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

PBX Series Quick Fit Connector Bimetallic Steam Traps

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Understanding and Caring for Your Septic System

BEST ENVIRONMENTAL MANGEMENT PRACTICES

Prevent Blockages in the Sanitary Sewer System

CHEMICAL CLEANING UNIT Product number:

SEPTIC SYSTEM. Taking care of your. ... what you need to know

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

ACO Water Management: Civils + Infrastructure

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Blowdown vessels Meeting the requirements of HSE PM60

BLÜCHER Drain Product catalogue for floor drains

Waste Oil Handling, Spill Containment & Lighting

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

Septic Tank Maintenance Information

How To Prevent Grease From Getting Into The Water System

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

FAST Owner s Manual. MicroFAST NitriFAST HighStrengthFAST RetroFAST

CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS

Septic System Owner s Manual

Be a part of the Team! Keep the Bay CLEAN!

Homeowner s Manual MIGHTY MAC. For: 500 Gallon-Per-Day. 600 Gallon-Per-Day. 750 Gallon-Per-Day

Food Handling Facilities, Waste Reduction & Water Quality Protection Guidelines

PROPAK AquaBio Complete Water Restoration Systems

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Fats, Oil and Grease Program Kit

foundation designed to keep water out of the basement.

Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations

Properly maintaining your septic system will help reduce the. It s Your Septic System. Homeowner s Guide. Here s How to Take Care of It

St. Joseph, Missouri Water Protection Homeowners Guide to Your Sewer

Village of St. Louis Sewer Back-up Policy

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010

Installation & Operating Instructions

CEILING CASSETTE FAN COIL UNIT

ECOLOGICAL LINE of bioexpert PRODUCTS

THE SEPTIC PROFESSIONALS TARGETED BACTERIAL SOLUTIONS CONSUMER PRODUCT CATALOG

A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

FREE-FLOW Biological Drain Maintenance Systems NCH Corporation

Oil and Coolant Circulating Heating System. Model - OCSM

Transcription:

Uniclass EPIC CI/SfB (52.4) March 2014 grease, sediment and oil

GREASE CONVERTERS A privately owned UK company with more than fifty years experience in the industry, Wade is established as a leading manufacturer of quality drainage products. Much of the success of the Company is attributable to an ongoing commitment to put technology to practical use, to generate fresh ideas, and to guarantee quality assured production. Meeting demands of water and municipal authorities, environmentalists, employers and employees, Wade provides effective and easy to use means of dealing with grease, oil and sediment. Actimatic Grease Converter Why use a Wade Actimatic Grease Converter? Grease flushed down the drain can cause blockages and unpleasant smells in work areas. Blockages can lead to overflows and health hazards, whilst drain clearing is an inconvenient and costly operation. A Wade Actimatic Grease Converter eliminates such problems and is a Natural means of Permanently converting grease to bio-degradable products. Use of an Actimatic Grease Converter is far more acceptable than chemicals or detergents which merely move grease downstream to become a problem for someone else. 2

GREASE CONVERTERS Degradation is a natural, slow process. Wade Actimatic uses only natural organisms to accelerate this process. Some typical locations where Wade Grease Converters are installed. How does it work? The Actimatic Grease Converter works in two stages: 1. Separation effluent entering the converter passes over a hydrafilter baffle* which causes grease to form in globules which float to the surface. 2. Digestion achieved by Wade Actimatic which produces a colony of micro-organisms to degrade wastes and convert to water soluble, environmentally friendly products. Oil Rig, North Sea Asda Store, Runcorn A McDonalds Restaurant Stock Exchange, London *Patent No. 13287055 Quality assurance Certification of compliance with BS EN ISO 9001 underlines our commitment to quality and service. 3

GREASE CONVERTERS Types of installation Floor standing (Standard and low profile models) Fully recessed in ground floor (Standard invert models) Fully recessed in ground floor (Deep invert model) Fully recessed in intermediate floor (Hanger type) Installation guidelines Wade Actimatic Grease Converters are designed to be installed in existing or new kitchens, at restaurants, canteens, hotels, hospitals, etc., and also at commercial or industrial premises where food is cooked, prepared or processed. They are not suitable for use with dedicated chicken rotisserie ovens unless special housekeeping measures are taken, including the introduction of water. There is no optimum distance between the last fixture and the converter; it is generally accepted that pipework longer than 8 metres may allow grease to solidify before it reaches the converter. It is not recommended that waste disposal units discharge into a Grease Converter, because frequent cleaning out will be necessary. Waste from vegetable peelers must be filtered before discharging. Certain cleaning agents (Chlorine, strong caustics, bleach etc.) in concentrated form, have a detrimental effect, and should not be discharged into a Grease Converter. Installations may require prior approval from the Local Authority Environmental Health Department. Wade Actimatic Grease Converters satisfy current Building Regulations / Standards in the U.K., and meet requirements of drainage systems designed in accordance with BS EN 12056-1:2000. Spigot adaptors for connecting to different types and sizes of pipework are shown on page 8. Note: Do not reduce the stated inlet or outlet size otherwise blockages could occur. 4

GREASE CONVERTERS Stainless steel grade 304 How to select and size Grease Converters To determine the optimum size of converter to be used, account must be taken of the volume of fixtures discharging into the converter. Use the table below to calculate total volume by entering the quantity of each fixture, multiply by the volume shown and enter as Total Vol.; finally, add up your answers. Type of fixture Approx. size Approx. vol. Total vol. (mm) (litres) Quantity (litres) Handwash sink 300 dia. x 180 deep 12 Domestic single sink 450 x 350 x 200 32 Domestic double sink (450 x 350 x 200) x 2 64 Commercial sink 600 x 450 x 300 81 Double commercial sink (600 x 450 x 300) x 2 162 Commercial potwash sink 760 x 500 x 380 144 Tilting kettle 150 Small dishwasher Outlet pipe 32 dia. 185 Medium dishwasher Outlet pipe 40 dia. 235 Large dishwasher Outlet pipe 50 dia. 350 Other fixtures Total volume of fixtures (litres) 6000 Series 6200 Series A A B G C 150 Min. E E D 2" BSP vent pipe connection (Vent to atmosphere if required) C 200 min. 140 D B F 200 75 After selecting the appropriate TYPE of INSTALLATION, and calculating the TOTAL VOLUME of FIXTURES, select the Spec.Code from the table below and add the required C dimension to nearest 10mm. e.g. for Converter to serve fixtures with a total volume of 325 litres and having a C dimension of 400mm, Specify: 6060XT C = 400mm. For details of materials, accessories and alternative covers, refer to page 8. Type of Max. total vol. of Spec. In/Outlet A B C D E F G Req. slab Load installation fixtures in litres code BSP inches mm mm mm mm mm mm mm opening class Floor standing Low profile 160 6020LR 4 775 482 150 180 330 l l A15 160 6022LR 2 775 482 150 180 330 l l l A15 290 6032LR 2 988 669 150 180 330 l l l A15 290 6035LR 4 988 669 150 180 330 l l l A15 Floor standing Standard invert 210 6030 4 594 382 150 368 518 l l l A15 410 6060 4 775 482 150 432 582 l l l A15 625 6080 4 988 669 150 419 569 l l l A15 Fully recessed 210 6030XT 4 594 382 368 l l l l A15 ground floor 410 6060XT 4 775 482 432 l l l l A15 Deep invert 625 6080XT 4 988 669 419 l l l l A15 Fully recessed 1250 6215 6 1516 953 737 l 482 775 l D400 ground floor 2100 6225 6 1869 1142 940 l 482 775 l D400 Fully recessed 210 6030H 4 594 382 368 l l l 625 x 445 A15 intermediate floor 410 6060H 4 775 482 432 l l l 805 x 545 A15 Hanger type 625 6080H 4 988 669 419 l l l 1020 x 730 A15 For the hanger types listed, the dimension from finished floor level to the underside of the hanger frame (normally slab level) is adjustable on site from 35mm minimum to 75mm maximum. N.B. In practice fixtures do not all discharge at the full rate simultaneously. This has been allowed for and the table enables the correct grease converter to be selected. In abnormally high or dump situations contact our Technical Services Department. To be specified on order 5

GREASE CONVERTERS Wade Actimatic Powder and Liquid Wade Actimatic is a bacterial product specifically formulated to deal with kitchen effluent. It is available in powder or liquid form. Actimatic Powder is a free flowing, buff coloured, granular powder; Actimatic Liquid is a green coloured, watersoluble liquid which is suitable for manual and automatic dosing. For technical information refer to back cover. To function efficiently grease converters must be dosed regularly with Wade Actimatic. Daily dosing is recommended, but where this is impracticable, dosing twice weekly is an acceptable minimum. When a converter is first put into service, and whenever it is cleaned out, a culture must be established or re-established within the converter per the Initial Dosing Procedure. The best time for dosing is just before closing down for the night; this is because the micro-biological activity is more effective when there is least flow through the converter. Details of automatic dosing are given on page 7. Initial dosing procedure (1 3 days after kitchen commences operation) Actimatic Powder Day 1 (a) Mix 8 level scoops (280 gm) with 2.25 litres (4 pints) of lukewarm water (30ºC); stir to form a slurry. (b) Remove the dosing plug from the converter and pour in the slurry. (c) Wipe up any spillage and replace the dosing plug. (d) Wait at least 4 hours before allowing any discharge into the converter this waiting time enables the micro-organisms to grow and reproduce in an ideal environment. Day 2 Repeat as for Day 1. Day 3 Commence daily dosing. Actimatic Liquid Day 1 Remove the dosing plug from the converter and pour in TWICE the amount shown in the Dosage Rate Guide. Day 2-7 Repeat as for Day 1 Day 8 Commence daily dosing. Daily dosing procedure Actimatic Powder Converter POWDER LIQUID Model No. Daily Monthly Daily Monthly level scoop Kg capfuls litres 6020LR 1 1 3 1 6022LR 1 1 3 1 6030 1 1 3 1 6032LR 1.5 1.5 4 1 6035LR 1.5 1.5 4 1 6060 1.5 1.5 4 1 6080 2 2 5 2 6215 2 2 6 2 6225 2 2 6 2 Note: (a) Mix the amount of powder shown in the Dosage Rate Guide with a little lukewarm water (30ºC). (b) Remove the dosing plug from the converter and pour in the solution. (c) Wipe up any spillage and replace the dosing plug. Actimatic Liquid Remove the dosing plug and pour in the amount shown in the Dosage Rate Guide. Remote dosing As an alternative to using the dosing plug facility, Actimatic may be poured into a sink which empties into the converter, and flushed with lukewarm (not hot) water. Dosage rate The amount of Actimatic needed depends on the converter model and the type and number of meals prepared. If there is a build-up of grease, increase the dosage, if there is little indication of grease, reduce the dosage. Actimatic is highly concentrated; overdosing is wasteful but not harmful. Daily dosage rate guide (with monthly equivalents) If dosing twice weekly instead of daily, use three times the rate shown. To Specify / Order: Spec. Code: AL1 Actimatic Liquid (1 ltr.) Spec. Code: AP1 Actimatic Powder (1 kg) Discount applies to standing orders. 6

GREASE CONVERTERS Automatic dosing system A mains powered dispenser unit is available for use with Actimatic Liquid. The unit automatically doses the Converter with diluted Actimatic Liquid once daily at a time selected by the user. GO 16:34 Control box Pump The system, once set, requires only monthly attention to replenish the liquid supply, and is suitable for use in most new and existing drainage systems. A warning light and an audible alarm indicates low level of liquid. To pipe run Outlet tube 8mm dia. Nylon Control box Storage drum Low level sensor Inlet tube 8mm dia. Nylon Storage drum Grease Converter Automatic dosing system installation notes Control box should be wall mounted. Electrical 220 240V, (Fuse rating 3 amp internally protected by 1.6 amp fuse). 50 60Hz single phase supply must be continuous and connected to control box via an isolator by a QUALIFIED ELECTRICIAN. Plumbing ensure control box and storage drum are in final operating positions. Inlet connect nylon tube to pump by pushing tube into INLET fitting. Feed other end of tube through hole in cap of storage drum until it reaches the bottom of drum (tube may be cut to length if desired). Outlet connect nylon tube to pump by pushing tube into OUTLET fitting. For connection to pipework up to 50mm dia., use quick fit adjustable pipe connector supplied. If connecting to pipework above 50mm dia., drill and tap a 1/8" BSP hole in a suitable pipe run leading to the grease converter. This hole MUST be located after the last trap in the run and in the top of the pipe if the run is horizontal. Screw and seal the supplied 1/8" BSP fitting into the tapped hole. Connect free end of tube by pushing into fitting. (Tube may be cut to length if desired). Audible alarm may be easily disabled if not required. Timer programming Dosing time must be set by following the instructions supplied. Optimum start time is 2 hours after kitchen closes. Start-up operation 1. Read Health and Safety notes printed on the 1 litre jerrycan containing Actimatic Liquid. 2. Fill storage drum with water to level indicated on drum label. 3. Add 1 litre of Actimatic Liquid. Larger grease converters require an additional amount refer to drum label. 4. Replace cap on drum and ensure that tube reaches the bottom of the drum. Construction Control box enclosure suitable for wall mounting; made of flame retardant polystyrene with removable cover, sealed to IP56. Size 180mm x 110mm x 90mm deep. Fixings stainless steel grade 304 minimum. Pump peristaltic type delivering 110 ml of liquid per minute. Storage Drum 10 ltr. capacity made of high density polythene; with screw cap and carrying handle; octagonal, 229mm across corners x 381mm high. Switches push-button, sealed to IP56. Timer programmable by user; Mains On and Low Liquid Level indicators; rechargeable back-up battery (maintains the timer programme, it will not run the pump). Tubing 8mm dia. clear nylon or equivalent. Maintenance 1. 30 days after start-up and every 30 days thereafter, re-fill storage drum with water and Actimatic Liquid. 2. Every 30 days check fittings and tubes for leaks. 3. Every 6 months check pump tubing for signs of wear. To Specify / Order: Spec. Code: ADU Automatic Dosing Unit Spec. Code: AL1 Actimatic Liquid (1ltr.) Options: Wall mounting bracket for storage drum made of grade 304 stainless steel with large radiussed corners to facilitate cleaning add suffix MB to Spec. Code. 7

GREASE CONVERTERS Accessories Covers are treadplate (anti-slip) stainless steel grade 304 Covers For alternative covers, add suffix to Spec.Code as follows: Heavy Duty (class D400) HD Recessed (min. C dimension = 170) REC For use with sheet floor covering (min. C dimension = 180) SVF B Threaded pipework adaptors to connect converter to pipework A Spec. Pipework A B code T103 BS 416 / DIN 19522 100 90 T104 BS 416 / DIN 19522 150 90 T105 BS 437 100 90 T106 BS 437 150 90 T1702 Plastic 54 60 T1704 Plastic 110 126 T303 Plastic 160 166 T401 Clay 100 170 T402 } (Densleve) 150 105 T501 Clay 100 130 T502 } (Supersleve) 150 130 Maintenance Commissioning period maintenance During the first few weeks of dosing operation, regular inspection of the internal condition of the Converter should be made to gauge the performance of the dosage amount. If a thickening of the contents is noted, with a distinct caking effect across the surface, or an offensive, pungent odour is emitted, then gradually increase the suggested dosage rate to compensate. If the contents appear to remain in a minimal semi-liquid state with little or no odour, this indicates successful degradation of the grease. Grease Converter performance The Converter is working if there is: (a) Consistency similar to thick soup. (b) Little or no odour. (c) No dry deposit building up on its sides. (d) No caked deposit floating on surface. (e) No grease build-up in downstream drain line. Routine maintenance Operation Remove main cover Remove and clean Hydrafilter baffle Check contents for caking Check for sediment build-up. If build-up has occurred tank should be cleaned Remove main cover Remove and clean Hydrafilter baffle Clean out tank completely Check joints and seal Frequency Quarterly Annually Whenever tank is cleaned out the Initial Dosing procedure must be repeated. Sediment build-up can be reduced if strainers are fitted to sinks to prevent solids entering the Converter. For best performance 1. Follow the Initial and Daily Dosing Procedures. 2. Do not discharge very hot water into the Converter immediately before or immediately after dosing. 3. Do not discharge chlorine, strong caustics, concentrated disinfectants, bleach or sanitisers into the Converter. 4. Do not deliberately discharge cooking oil or grease into the Converter. 5. Remember that food scraps and solid particles will settle on the bottom of the Converter and will need to be removed periodically. Do not discharge waste disposal units into the Converter. 6. Follow maintenance procedures. 7. Contact Wade Technical Services Department if you need advice; a free call out service is provided in mainland UK for regular users of Actimatic. Dosing plug (Sealed) Hydrafilter baffle Main cover seal Inlet (Threaded BSP) Anti-slip removable main cover (Sealed) Rodding access (Sealed) Anti-siphon tube Outlet (Threaded BSP) Deep seal trap Q Units with C dim.up to 750mm Materials Seal expanded closed cell neoprene. Other parts stainless steel grade 304. For grade 316 stainless steel, add suffix M to Spec. Code; a plain cover is supplied with grade 316 versions, if anti-slip cover is required add suffix MAS (anti-slip cover is grade 304). Note: 6200 series models have covers with no dosing plug or rodding access. 8

Sediment Interceptors SEDIMENT INTERCEPTORS Stainless steel grade 304 Sediment Interceptors are used to help prevent blockages where solids such as food scraps, hair, plaster, sediment etc. are discharged into drain lines. How does it work? Bucket lifting handle 390 x 390 Sealed removable cover Solid material is captured in a collector a bucket or, for fine particles, a filter bag which needs to be lifted out of the interceptor for emptying at an appropriate frequency. Fastener 105 125 Features l suitable for floor standing or semi-recessed installations l 2" BSP female inlet and outlet may be connected to pipework by means of proprietary connectors Material Stainless steel grade 304, satin finish Seal expanded closed cell neoprene. 2" BSP inlet 430 2" BSP outlet Sediment bucket or filter bag Options For polished finish, add suffix P to Spec. Code. Routine maintenance Operation Frequency Spec. Flow rate Solids code l/sec. collector 5740 0.4 Bucket stainless steel (1.75mm dia. hole size) 5750 0.4 Bag polyester (100 micron hole size) Note: Minimum clearance above cover of 450mm is required for removal of bucket/bag Remove main cover Remove and clean collector Drain and clean tank Check joints and seal Annually 9

OIL INTERCEPTORS Stainless steel grade 304 Oil Interceptors Oil Interceptors are installed in drain lines to help prevent the pollution of rivers, streams, drainage systems and water treatment plants. Units are used where spillages of oil or diesel could occur such as garages, transport workshops, diesel re-fuelling and storage areas, and where vehicles or plant are washed down or steam cleaned. Oil Interceptors are not suitable for petrol and volatile liquids. How does it work? The Wade trapped Oil Interceptor works in three stages. 1. Separation Effluent entering the Interceptor passes through a filter bucket which retains solid material; oil, being lighter than water, floats to the surface, pending draw-off. 2. Removal of oil By automatic or manual means, oil flows through an adjustable draw-off point to a sump or a similar storage container awaiting disposal. 3. Removal of solids The bucket which retains solid material needs to be lifted out of the Interceptor for emptying at an appropriate frequency. Features l suitable for floor standing or recessed installations. l vent and draw-off connections are provided on both sides of the Interceptor for ease of installation and use. l draw-off points located inside the Interceptor are adjustable by the user (see drawing and notes on page 11). l loading class: D400. l recessed covers can be made to special order. l threaded inlet and outlet are for connection to pipework by means of a spigot adaptor, shown on page 8. Materials Seal expanded closed cell neoprene. Other parts stainless steel grade 304. For grade 316 stainless steel, add suffix M to Spec. Code; a plain cover is supplied with grade 316 versions, if anti-slip cover is required add suffix MAS (anti-slip cover is grade 304). 2" BSP vent connections (Both Sides) C 100 100 250 A x B C Anti-slip, sealed removable cover Rodding access (Sealed) Outlet (Threaded BSP) Inlet (Threaded BSP) D 160 Deep seal trap Sediment bucket 2" BSP adjustable draw off (Both sides) To Specify / Order Select the appropriate code from the table and add the required C dimension, e.g. for oil interceptor to accept a flow 3.5 l/sec. and having a C dimension of 250mm. Specify 6360, C dimension = 250mm. Spec. Flow rate Inlet / Outlet code l/sec. size BSP A B C D 6330 1.9 4" 594 382 To be 368 6360 3.8 4" 775 482 Specified 432 6380 5.7 4" 988 669 on order * 419 Note: *Minimum C dimension available is 150mm, larger dimensions should be specified in increments of 10mm. Larger sizes of oil interceptors are available, please contact our Technical Services Department for details. 200 10

OIL INTERCEPTORS Installation Notes: 1. 2" BSP Vent and drawoff connections are provided on both sides of the interceptor for ease of installation. 2. All connection points not used must be sealed. 3. Ensure location of interceptor enables easy access to draw-off valve and cover. Settings of adjustable draw-off Adjustable draw-off INLET OUTLET Adjustable draw-off Interceptor vents. Ensure pipework is extended so that one vent finishes 250mm. above the other. Draw-off valve (not supplied). Required only if manual operation is desired. To receiving container. For automatic operation use storage tank. For manual operation any suitable container may be used. Normal water operating line 3mm Normal water operating line 6mm Static water line To receiving container Static water line To receiving container Setting A Ensures that only oil is taken from interceptor Normally used in automatic installations with drawn-off oil collecting in storage tank. This setting will retain a layer of oil in the interceptor. Checking operation If during normal working conditions water is found to be entering the draw-off line, the following action should be taken; For manual and automatic operations: Adjust draw-off upward by 3mm. Check operation, repeat if required. Maintenance Commissioning period maintenance Manual draw-off During the first 4 weeks of operation, regular inspection of the internal condition of the interceptor should be made to determine how often the oil needs to be drained off and the sediment bucket emptied. Automatic draw-off During the first 4 weeks of operation check the oil storage tank for build-up, and the sediment bucket to determine how often it needs to be emptied. Routine Maintenance Operation MANUAL Remove main cover Drain off oil Remove and clean sediment bucket AUTOMATIC Remove main cover Remove and clean sediment bucket BOTH TYPES Remove main cover Remove and clean sediment bucket Drain and clean tank completely Check joints and seal Frequency As indicated by inspection during commissioning period. Annually Setting B Ensures that ALL oil is removed from interceptor Normally used with manual draw-off installations. This setting will allow water to enter the draw-off line. Checking operation If during normal working conditions oil is found to be remaining in interceptor, the following action should be taken; Manual installations: Draw-off oil more frequently and/or lower draw-off by 3mm. Check operation and repeat if required. Automatic installations: Lower adjustable draw-off by 3mm. Check operation, repeat if required. Sediment bucket Vent connections Inlet Baffle plates Anti-slip main cover Rodding access Main cover seal Outlet Adjustable draw-off Trap 11

GREASE CONVERTERS SEDIMENT INTERCEPTORS OIL INTERCEPTORS Wade Actimatic supplementary information Wade Actimatic is a mixture of micro-organisms, free enzymes, inorganic salts, buffers and non-ionic surfactants. Six strains of micro-organism are selected because of their ability to produce the enzymes required to break down the range of waste materials produced by the catering industry. The micro-organism population comprises a range of bacilli, micrococcus and streptomycete cultures. Four main types of enzymes are produced by the micro-organisms which operate in Wade Actimatic: Lipases to break down fats and grease Amylases to break down starch Proteases to break down protein Cellulase to break down cellulose Enzymes serve to accelerate the establishment of the micro-biological culture; they have a limited life and will eventually be used up. Any dead micro-organisms will themselves be broken down and digested by other bacteria. The micro-organisms in Actimatic Powder are naturally occurring and are not genetically engineered or genetically modified; they belong to Class1 as defined in the EU Council Directive 90/679/EEC of 26th November, 1990 and as amended by EU Council Directive 93/88/EEC of 12th October, 1993. Actimatic Powder and its intermediates are tested using procedures recommended by the USDA and AOAC to ensure that they are free of Salmonella. Environmental impact. The term BOD, biological oxygen demand, is often used in association with biological breakdown. BOD is a measure of the amount of organic matter in water and waste; it is the amount of oxygen in a given volume of water, consumed by microorganisms during the degradation of organic matter over a five day period. High BOD causes concern since the loss of soluble oxygen in the water can create anaerobic conditions, which give rise to the production of foul odours arising from the formation of sulphides (particularly H 2 S ) and methane; these conditions inhibit the degradation of fats and grease. Wade Actimatic will not increase the BOD of the discharge from a correctly sized grease converter, nor the BOD loading of the final effluent plant. All the ingredients of Wade Actimatic are bio-degradable and will have no adverse effect on the downstream biological clean-up operation. Grease is converted permanently into soluble products which will not re-deposit further down the drainage system. Wade Actimatic, when properly used, is not harmful to people, wildlife or the environment. Independent product assessment: In 1989 Wade became the first manufacturer of grease converters to be awarded an Agrément Certificate. For the Grease Converter, an innovative product, there is no applicable British or European product standard. BS EN 1825 applies to products that require the physical removal of grease; the scope of the standard states The standard does not cover the use of biological means (bacteria and enzymes). Other products Wade manufactures a wide range of products for use in and near all kinds of buildings, worldwide: Floor gullies, access covers, channel and grating, roof outlets, water points. Full details, including CAD files are accessible on our website Service Product information and technical advice are available from the Wade Technical Services Department at Halstead, Essex, from Wade Technical Consultants located throughout the UK and from selected distributors throughout the world. Warranty The Company warrants its products to be free from defects in material and workmanship for a period of 12 months from the date of delivery. The Company s obligation under this warranty is limited, at its option, to the repair or replacement, free of charge, or refund of the net invoiced price of any part found to be defective, and which, in the Company s opinion, has not been subject to undue wear and tear, accident, alteration, abuse or misuse. Consequential damages are expressly disclaimed. Technical advice from Wade International Ltd., whether verbal, in writing or by way of trials, is given in good faith but without warranty. The application, use and installation of the Company s products are beyond the control of the Company and the purchaser is solely responsible for ensuring that goods are fit for any particular purpose. In line with the Company s policy of continual research and development, product specifications and availability are subject to change or withdrawal without prior notice. Dimensions In line with general practice all dimensions shown are nominal. Load rating class This catalogue shows the load rating class for covers based on BS EN 124. QUALITY BY TRADITION PERFORMANCE BY DESIGN Wade International Ltd. Third Avenue. HALSTEAD Essex. CO9 2SX. UK TELEPHONE: +44 (0)1787 475151. FACSIMILE: +44 (0)1787 475579 e-mail: tech@wade.eu. web site: www.wade.eu 7412