This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.



Similar documents
1. Description. 2. List of Accessories included A B C F G H

Please also see 10 golden rules for correct Saniflo installation on

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

For heavier duty macerator/pumping applications

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

SF15K SF05KSS, SF10KSS

Operators manual Basic water heater

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Line to Refrigerator Ice/Water Dispenser

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Conlift1, Conlift2, Conlift2 ph+

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

SERVICE MANUAL Order No.WH0911S001V0

ELECTRIC INSTANTANEOUS WATER HEATER

Plumbing for retail food businesses

REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

Heavy Duty Pressure Washer Kit RAC-HP021

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

PLUMBING CARE AND REPAIR

INSTALLATION & USER INSTRUCTIONS

SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

ADVICE NOTE WATER LEAKS. How to prevent water leaks in your flat

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

INFRARED QUARTZ WALL HEATER

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

CERTIFYING DRAINLAYER

Portable Air Conditioner

Your Pressure Sewerage System Guide

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

ONTARIO PLUMBING INSPECTORS ASSOCIATION INC. In the public service since Wet Venting. Incorporating Stack Venting and NPC Harmonization

Meaco 30L and Meaco 40L dehumidifier instruction manual

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

VOYAGER 570G. 744A Sprayer Control

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Oil and Coolant Circulating Heating System. Model - OCSM

Session 2: Hot Water Supply

LUCCI AIRFUSION QUEST II CEILING FAN

DRAIN CLEANING MACHINES

INSTALLATION INSTRUCTIONS & OWNERS GUIDE

The space saving solution.

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

Alpha CD13R,18R and 24R

WATER LEAKS AND DAMAGE

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION. This guidance is endorsed by HHIC members.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Use and Care Manual. Model CPA12KH AIR CONDITIONER

*h5h/7h$ù,5,7ø75(ùø0/(59(68.$d$./$5, <$1/,ù0217$-'$1.$<1$./$1$%ø/ø5 &ø+$=,$6/$d$/,ù0$67$1',h=(5ø1'( 7$ù,0$<,1,=

IMPORTANT SAFETY NOTICE

CEILING CASSETTE FAN COIL UNIT

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

SILENT AIR COMPRESSOR

SunMaxx Solar Filling Station Operating Instructions

Cooktop Low-Profile Ventilation Hoods

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

LC-50 FOOD WASTE DISPOSER Installation Manual

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

AFE424 SERVICE PARTS

Waste Oil Handling, Spill Containment & Lighting

IH E Sigma Island 90

3 IN 1 BATHROOM HEATER

HERZ-Thermal Actuators

Chill 4 Hole Bath Shower Mixer

OPERATING & MAINTENANCE AIR COMPRESSOR RANGER 35 INSTRUCTIONS. Part No:

The most advanced Undersink Sullage System with inbuilt controls and alarms.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

B150 Series Commercial Brewer. Direct Plumb Kit

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

REMOVAL AND INSTALLATION

INSTALLATION INSTRUCTIONS MK-8704

good to know... SEWER BACKUP A guide to protecting your home

Thermostatic bar showers. Troubleshooting and maintenance

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

MIC-WKT and MIC-WKT-IR

OWNER S MANUAL & INSTALLATION GUIDE. Installation Details Owner s Information Warranty. 80L - 400L Electric Storage Water Heaters

Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

Transcription:

1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular attention to the following: Possible danger to personnel Warning of possible electrical hazard ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit. This equipment benefits from the latest technological innovations concerning soundproofing. To benefit fully from the advantages provided by this new generation of appliances, it is important to comply with the installation instructions in section 5. 2. List of Accessories included x3 A Rubber connector 25 x 40mm Metal hose clip Metal hose clip x2 I Floor mounting bracket 40 x 60mm D Air vent cover End cap F x2 C Discharge elbow E B x6 G x2 H 32 x 50mm Metal hose clip Floor mounting screws

3. Dimensions and overall measurements This unit is for domestic use only. 373 mm 185 mm 92.5 mm 314 mm 256 mm 277 mm ø 40 36 mm 309 mm 139.4 mm 4. Performance Curve & Height and Length of the discharge pipe Vertical Height - metres 5 4 Metres 3 2 ø 32 The discharge pipe size for Sanivite must be 32mm. 1 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Flow Rate L/min Max 5m max 10m 4m 3m 2m max 20m max 30m max 40m 3 7 1m max 40m 1%

5. Installation H H I I The unit should be accessible for possible maintenance. It is supplied with floor fixing lugs to prevent it from moving during use. If pumping vertically, always put the vertical before the horizontal at the start of the piperun. 6. Connection to side inlets G A G C Use the rubber connector (A) for connection of pipes to the side inlets. Secure with the metal hose clips (G). Cap off unused inlets with the end caps (C) provided, after greasing the joints. C 7. Connection to lid inlets G To connect to a lid inlet, cut off the sealed cap with a hacksaw and connect using the rubber connector (A) provided. Tighter with the metal hose clips (G). A G

8. Connection of bathroom appliances To connect a shower/bath, ensure that the trap exit is 15cm above floor level. Although not obligatory, a lid connection may be used to run an external air vent. 15 cm 9. Discharge connection 3 3 7 Note: The discharge pipework should be 32mm copper or rigid solvent weld plastic. Observe the pumping parameters of the unit (vertical and horizontal combination, step 4). All horizontal pipe runs must have a minimum fall of 1:100 (10mm per metre) all the way to the drain. Technical advice for discharge to lower floor If the discharge pipework runs to a level considerably lower than the unit, the resultant siphoning effect can suck out the water seal in the unit. Fitting an air admittance valve capable of withstanding 10psi pressure (BBA approved) at the high point of the pipe run will overcome this problem. Orient the opening end of the non-return valve in the direction of the discharge. Secure with the metal hose clip (F). 10. In case of servicing For possible service requirements, provide a drain off at the low point of the installation.

11. Electrical connection The electrical installation should be carried out by a qualified person. All wiring must conform to BS7671, 1992 requirements for electrical installations. The Sanivite requires a 220/240V single phase AC 50 Hz supply (UK specification). Do not connect the Sanivite to a conventional plug and socket. It must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The Sanivite has an earth wire. The wires in the mains lead are coloured in accordance with the following code: Brown Live Blue Neutral Green/Yellow Earth Warning: Ensure the electricity is turned OFF at the main switchboard before wiring to connector. All work on cable, pressure chamber and motor should only be carried out by a qualified Saniflo servicing agent, as special tools are required. UK 230/240V 50Hz. The unit should be installed so it is easily accessible/removable for possible maintenance. The unit should not be exposed to splashing in normal use. CANADA USA EUR CH GB 12. Norms The unit conforms with EN 12050-2 waste water lifting plant. SANIVITE Société Française d Assainissement EN 12050-2 FF02-v35 220-240 V - 50 Hz - 400 W - IP44 1,7A - 6,3 KG 13. Care and use The Sanivite is designed to handle the waste evacuation from a bath, domestic kitchen sink, dishwasher and washing machine - all working at the same time if required. Its powerful pump will deal with every day normal usage. Warning: Do not dispose of solvents, paints (do not wash paint brushes in sink), caustic, acid or other chemicals into these products. Depending on usage, the unit may need to be cleaned from time to time. Heavy usage can result in a build up of fat and grease. The unit will pump away water as hot as 90 C for 5 minutes (i.e. to clear the hottest waste water from a washing machine). However, do not pour boiling water directly into the unit. When pumping very hot water for a prolonged period of time, the unit will automatically cut out to protect the motor (thermal cut-out). When this happens the unit will shut down long enough to cool down (approx.1 hour) and automatically resume normal operation when ready. 14. Dismantling Disconnect from the power supply before attempting any work on the unit. The unit does not require any specific maintenance. In case of a service requirement, please call the Saniflo service engineer, especially for any electrical work. 15. Guarantee 2 years guarantee as from its date of purchase subject to correct installation and correct use.

16. Parts