Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling



Similar documents
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Top 10+ Mistakes of DWV plumbing design

What to Expect From the Examination. How to Study the Plumbing Codes

ONTARIO PLUMBING INSPECTORS ASSOCIATION INC. In the public service since Wet Venting. Incorporating Stack Venting and NPC Harmonization

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007

Plumbing Code Sections For Commercial Food Facilities

Residential Plumbing BCN 1058

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

When Should Examination Preparation Begin?

2006 Codes. Please verify the following before calling for inspection

FAQ and Device/Usage Chart. What Is a Cross-Connection? What Is Backflow Prevention? What Is Backflow?

Backflow Bulletin #1

How to Protect Your Property Against Plumbing Disasters

2. What building projects are exempted? (permit not required)

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

PMA ONLINE TRAINING Venting for Plumbing Systems

Amendments to the 2012 International Plumbing Code

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

Basement Development Construction requirements for the development of basements in residential dwellings.

PLUMBING. For HOME OWNERS

Does Wall Township require an inspection by the building department on resale of a home?

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

CHAPTER 9 VENTS TRANSPORTATION OF SEWER GAS

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

PROPOSED Plumbing Fee Ordinance Amendment

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

City of Elk River BASEMENT Office Use Only

Applications for building permits will not be reviewed until all of the required information has been submitted.

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

Element D Services Plumbing

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Minimum Housing and Health Standards

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

Building Permits: When are they required?

Self-Home Inspection Checklist

Plumbing Code in Commercial Kitchens

Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

The Plumbing Pipeline

Jay R. Smith Mfg. Co.

Common Causes of High Water Bills

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Understanding and Designing Plumbing Systems

Plumbing Identification and Damage Assessment Guide

CONSTRUCTION PERMIT APPLICATION AND INSTRUCTIONS (Permit Application follows instructions)

good to know... SEWER BACKUP A guide to protecting your home

Isometric Plumbing Drawings

To many people, a home s plumbing system is perceived as being extremely

Arapahoe County Residential Water Heater Installation and Inspection Guide

A Residential Owner s Guide to PERMITS. Elgin CITY OF PLANNING & NEIGHBORHOOD SERVICES

Home Maintenance Checklist

CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS

APPLICATION FOR NEW CONSTRUCTION

HOMEOWNER S PERMIT GUIDE

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Protect your. home from. basement. have you done everything you can?

Plumbing Apprenticeship Program Curriculum

2012 British Columbia Plumbing Code Update

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

2014 Oregon Plumbing Specialty Code New Oregon Amendments

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

BASEMENT FLOODING. Prevention Guide for. Homeowners

Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot

Builder Specifications for Solar Ready Homes

PLUMBING ROUGH IN INSPECTION

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

PLUMBING PERMIT APPLICATION (PLUMBING PERMIT TO BE SECURED 24 HOURS BEFORE WORK STARTS)

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

Home comfort: water heating

WHEN IS A PERMIT REQUIRED?

INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION. This guidance is endorsed by HHIC members.

Lot Number. City. Architect Name SUBCONTRACTORS - COMPLETE AND ATTACH LIST ON PAGE 4

South Carolina Home Inspector Standards of Practice

BUILDING PERMIT SPECIFICATIONS

ESTIMATING PLUMBING, HEATING, VENTILATING, AND AIR CONDITIONING (HVAC), AND ELECTRICAL WORK

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

Plumbing Code Statutes and Regulations February 2011 Labor Standards and Safety Division Mechanical Inspection

How To Fix A Leaky Water Heater

WHITE PLAINS PLUMBING CODE PART 1. GENERAL REQUIREMENTS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PLUMBING SPECIALTIES

Georgia State Amendments to the International Plumbing Code

PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC

6. Principles of effective plumbing systems

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Preventing water damage in the basement

Protect Your Home From Flooding. A guide for Lethbridge Residents

Inspection Item COMMENTS

Protect your home from basement flooding

later damage - Loss ControL

PREVENTING WET OR FLO ODED BASEMENTS

Chapter 7 Plumbing Connections

ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM REQUIREMENTS

2016 BUILDING PERMIT FEES*

Propery Inspection Report

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

RRIO Checklist. Use of checklist: Definitions: Limitations

Transcription:

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001

contents General Information 3 Inspection 4 New Drain and Vent Installations 5 Potable Water Systems 15 Protection From Contamination By Cross Connections 17 note This booklet has been written to: 1) Provide homeowners with a summary of some more common plumbing regulations; and 2) Provide information on the extent to which the plumbing work must be completed before requesting an inspection. It is recommended that the applicable sections of this booklet be reviewed before commencing the project. Please note that this booklet is not intended to cover all of the plumbing regulations. Complete plumbing requirements are covered in the Manitoba Plumbing Code. Every effort has been made to ensure the accuracy of information contained in this booklet. However, in case of a discrepancy between this booklet and the governing City of Winnipeg Bylaw, the By-law will take precedence. 2

When is a plumbing permit required? A plumbing permit must be obtained from the City of Winnipeg Planning, Property and Development Department, Unit 31-30 Fort Street whenever: a) a plumbing system is constructed, extended, altered, renewed or repaired, and b) when water supply lines in a building are replaced. NOTE: Lead free solder is required for all drinking water supply lines. When is a plumbing permit not required? A plumbing permit is not required when: a) a stoppage in the drainage system is cleared; b) a leak is repaired in a water distribution system; c) a fixture is replaced without any change to the drainage system; or d) a replacement is made to existing faucets, or service water heaters. Who may obtain a plumbing permit? Plumbing permits can be issued only to: a) a person who holds a Plumbing Contractor s license from the City of Winnipeg authorizing that person to carry out business or trade in the City of Winnipeg; OR b) the owner of a detached single family dwelling who is also the occupant. The owner personally must do the work. The permit would be issued to the owner provided the Manager of Building Inspections is confident the work will be done competently. general information Can a plumbing permit be transferred to an individual other than the original applicant? No! A plumbing permit is not transferable. FIGURE 1 - Typical Basement Plumbing Diagram Existing 1 1 /2 in. vent connection 1 1 /2 in. Existing 4 in. Drain Basin Toilet Backwater Valve 2 in. Shower 3

general information What information is required to apply for a plumbing permit? To obtain a plumbing permit, the homeowner must present a plumbing diagram for the proposed installation with the following details: a) the diagram must have a view from the side; b) be drawn as single line; c) show the drain and vent pipe sizes; d) show the location of each fixture. An example of a typical plumbing diagram is shown is FIGURE 1. How much does a plumbing permit cost? The plumbing permit fee is $16.27 for the rough-in and installation of each fixture outlet. If the plumbing in the basement has previously been roughed-in under another permit and only the fixtures are being installed at this time then the fee for finishing is $7.12 per fixture. The fee for a new single family dwelling is $122.04. The minimum permit fee is $23.39. Please note that these fees are subject to change. inspection What must be ready for the first inspection? Before calling the plumbing inspector, all drains and vents should be completed. The work must not be covered before inspection. If any part of the plumbing work is found deficient during inspection, alterations or replacement must be made as necessary. The work may be subject to additional inspections. Please call the inspector the morning of the day that the inspection is required. The inspectors office hours are between 8:30 a.m. and 9:30 a.m. weekdays. These are the only times that the inspector can be contacted to arrange an inspection. 4 What must be ready for the final inspection? Before the final inspection, all fixtures and equipment must be installed and ready for use. If a fixture has been roughed-in for future use, the outlet must be sealed with an approved plug or cap. Upon completion please contact the plumbing inspector for a final inspection.

What is the minimum slope requirement for drains? All drains must be installed to provide a minimum slope away from the fixture of at least 6 mm (1/4 in.) for every 300 mm (1 foot) of pipe length. The drains must be supported by a firm base/hanger to remain in that position. See FIGURE 2. What is the total fall allowed from a fixture trap to the vent? Except for a water closet, the total fall from the fixture trap to the vent must not exceed the diameter of the fixture drain. See FIGURE 3. FIGURE 2 - Minimum Slope of Drains 310 mm (12 1 /2 in.) Sand 10 ft. Drain sloped at 6 mm ( 1 /4 in.) for every 300 mm (1 foot) FIGURE 3 - Fall of Fixture Trap 250 mm (10 in.) Firm Earth new drain & vent installations PERMITTED NOT PERMITTED The shaded area that shows the fall must not be greater than the size of the fixture drain. 5

What is the maximum distance allowed between a vent pipe and a fixture trap or a water closet? The maximum distance between a vent pipe and a fixture trap must not exceed 1.5 m. (5 ft.). The distance between a vent pipe and a water closet must not exceed 3 m. (10 ft.) horizontally and 900 mm (35 in.) vertically. See FIGURE 4. Are expansion fittings required for piping systems? Yes! The design and installation of every piping system must, where necessary, include means to accommodate expansion and contraction of the piping system caused by temperature change. Therefore, where plastic pipe is used, expansion joints must be installed at the base of every soil or waste stack. See FIGURE 4. 6new drain & vent installations FIGURE 4 - Lengths of Fixture Drains and Expansion Fitting 3 1. Length must not exceed 900 mm (35 in.) 2. Min. length is twice the diameter of the fixture drain. Max. length must not exceed 1.5 m (5 ft.). 3. Max. length is 1 m (39 in). 4. Max. length is 3 m (10 ft.). 5. Expansion fitting - size of a soil or waste stack. 6. Cleanout. 1 4 6 2 5

What are the locations of the cleanout fittings in the drainage system? Approved cleanout fittings must be installed at the following locations: a) as close as practicable to the point where the building drain leaves the building; b) at the base of every soil or waste stack; c) to permit the cleaning of vents to the flood level rim of kitchen sinks; and d) at every 90 degree change of direction in sink wastes. See FIGURE 5. What are the requirements for the installation of T and Y fittings in the drainage system? Tee fittings or 90 degree elbows must not be used in the horizontal portion of a drainage system. All changes of direction must be made with the use of Y s and 45 degree bends. Except that a 90-degree elbow or tee fittings may be used to change the direction of horizontal drains when the direction of flow is down to the vertical. Tee fittings may be used to make the connections to vent pipes. See FIGURE 6 and FIGURE 7. (Exceptions see FIGURE 8). FIGURE 5 - Building Drainage System With Cleanout Fittings new drain & vent installations Basin Basin Line Cleanout C.O. Kitchen Sink Bathtub W.C. W.C. Automatic Washer C.O. Expansion Expansion C.O. C.O. C.O. Basin W.C. C.O. Backwater Valve Catch Basin Shower 7

new drain & vent installations FIGURE 6 - Permitted Use of Sanitary T ( TY ) Fittings - Part 1 Dry Vent Vent Sanitary T Drains 8

FIGURE 7 - PERMITTED PERMITTED FIGURE 8 - Permitted Use of Sanitary T ( TY ) Fittings - Part 2 NOT PERMITTED NOT PERMITTED Permitted Use of Sanitary T ( TY ) Fittings - Exceptions new drain & vent installations Permitted use of long sweep 90 degree Permitted use of 90 degree Typical Installation Fixture Fixture NOT PERMITTED PERMITTED 9

new drain & vent installations Can drainage or water piping be installed in exterior walls? Where piping may be exposed to freezing conditions, it must be protected. No drainage or water system can be installed in any exterior wall of a building. Vent pipes are permitted in exterior walls. Is room ventilation for bathrooms required? Yes! Ventilation of bathrooms or any rooms containing a water closet must be provided by either; a) a window with an openable area of at least 0.09 sq. m. (0.97 sq. ft.); or b) a mechanical exhaust system (fan) to the outdoors. NOTE: Natural ventilation such as an openable window is considered suitable only for summer use and tends not to be used in winter, thus resulting in unacceptable air quality. What requirement must be met for the venting of multiple fixtures? A soil or waste pipe extended as a stack vent or a continuous vent may serve as a single storey vent if: a) all fixtures served by the vent are in the same storey; b) the number of vented fixtures does not exceed four; c) the number of vented water closets does not exceed two; d) when two water closets are installed they are connected at the same level by an approved double fitting; e) water closets are connected downstream of all other fixtures, and f) the fixture drains are connected separately and directly into the soil or waste pipe. See FIGURES 9, 10 & 11. FIGURE 9 - One Storey Venting (Back to Back) Basin 1 1 /4 in. Stack Vent Basin 1 1 /4 in. Wet Vent Water Closet Shower Bathtub 1 1 /2 in. 1 1 /2 in. Water Closet 10 Soil - Waste Stack

Shower FIGURE 10 -Two Storey Venting ROOF SECOND FLOOR FIRST FLOOR 1 1 /2 in. Basin 1 1 /4 in. 1 1 /2 in. 2 in. 2 in. 2 in. Water Closet Automatic Washer 2 in. 1 1 /2 in. Heat Duct Basin 1 1 /4 in. Water Closet new drain & vent installations Wet Vent 11

new drain & vent installations When is a backwater valve required? All fixtures installed below street level must be protected by a backwater valve arranged to prevent sewer back-up. The backwater valve must be installed to protect the branch drain. The backwater valve must not be installed on a building drain or building sewer unless approved by the Authority Having Jurisdiction. See FIGURE 5 and FIGURE 11. A sump pit should be installed with the backwater valve. FIGURE 11 - Typical Basement Plumbing Installation Showing Venting Method, Backwater Valve & Attachment to Cast-Iron Piping To install new rough-in plastic basement plumbing to existing cast-iron piping use plastic to cast-iron adaptor and M.J. (mechanical joint adaptor) clamps 4 in. Building Drain Approved Backwater Valve must be installed on branch drain to protect all new plumbing that is below grade. Branch Drain 4 in. See Vent Pipe Connections Page 13 Min. 2 in. to this point Water Closet 2 in. Wet Vent 2 in. 1 1 /2 in. 2 in. 1 1 /2 in. 1 1 /4 in. Basin Shower FIGURE 12 - Location of Vent Pipes Cumulative Change in Direction Max. fall of trap arm is equal to pipe size Max. developed length 1.5 m (5 ft.) Min. Developed length is two times pipe size 12 Sanitary Tee 90 degree 45 degree Total change in direction is 135 degrees Y 45 degree Wet Vent FD 45 degree 45 degree

What is the maximum cumulative change in direction permitted between a fixture trap and a vent? The cumulative change of direction between a fixture trap and a vent must not exceed 135 degrees. See FIGURE 12. What are some requirements to be met when vent pipes are being connected and being run through the dwelling to the roof? a) Where a vent pipe passes through the roof, it must be protected from frost closure by increasing the pipe size to at least 75 mm () in diameter immediately before penetrating the roof. b) It is recommended that a vent located in attic spaces be insulated. c) Vent pipes must be installed without depressions in which moisture can collect. d) A vent pipe must extend vertically above the flood level rim of every fixture that it serves before being connected to another vent pipe. See FIGURE 13. FIGURE 13 - Vent Pipe Connections Vent terminated through roof To be increased to 75 mm () new drain & vent installations Vent to connect above flood level rim of fixture Vent connected to stack vent in attic space Min. 75 mm () Flood Level Rim 13

new drain & vent installations TABLE 1 - Fixture Size Requirements FIXTURE MIN. SIZE OF FIXTURE OUTLET PIPES (inches) Bathtub (with or without shower) 1 1 /2 Bidet 1 1 /4 Clothes Washer 1 1 /2 Dishwashers (no load when connected to a 1 1 /2 garbage disposal unit or a kitchen sink trap Garbage disposal units - residential type 1 1 /2 Laundry sinks 1 1 /2 Lavatories (basin) 1 1 /4 Shower Drain 1 1 /2 Sink - one and two compartments 1 1 /2 with garbage disposal unit Water Closet 3 FIGURE 14 - Typical Drainage & Vent Sizing 1 1 /2 in. 1 1 /4 in. Kitchen Sink Main Vent Basin 1 1 /4 in. Water Closet Bathtub 1 1 /2 in. 1 1 /2 in. Building Sewer Cleanout 4 in. (to street) 1 1 /2 in. 4 in. Building Drain Expansion Fitting 4 in. Backwater Valve 4 in. Catch Basin 4 in. Building Drain Cleanout 4 in. 14 NOTE: Every building drain must be at least 100 mm. (4 in) in size and must be terminated by a vent at least 75 mm () in size.

What are the size requirements for fixture outlet pipes? The sizes of all fixture outlet pipes must comply with TABLE 1. See FIGURE 14. What are the requirements that must be met for the installation of a potable water system? All potable water systems must meet the following standards. a) Every water service pipe must be provided with a shut-off valve where the pipe enters the building. b) A water distribution system must be installed so that the system can be drained or blown out with air c) Every fixture supplied with hot and cold water controls must have the hot water control on the left and the cold water control on the right. d) Every water closet must be provided with a shut-off valve on the water supply pipe. e) Every pipe that passes through an exterior wall to supply water (i.e., lawn service) must be provided with a frost-proof hydrant or a stop-and-waste valve placed inside the building close to the outside wall or other approved location. Also, a hose bib vacuum breaker must be installed on a hose bib located outside a building or inside a garage to protect against backflow. f) Every hot water tank must be provided with a shut-off valve and a pressure and temperature relief valve. The pressure and temperature relief valve must be designed to open when the water pressure in the tank exceeds the rated working pressure of the tank or when the water temperature exceeds 99 C (210 F). Every temperature and pressure relief valve must be provided with a drain and the drain must extend to within 300 mm (12 in.) of the floor or to a safe location. See FIGURE 15. potable water systems 15

potable water systems FIGURE 15 - Hot Water Tank Fittings & Water Supply Shut-off Valves Stop Valve Union Hot Water Tank Temperature and Pressure Relief Valve NOTE: A Temperature & Pressure Relief Valve is to be installed within 150 mm (6 in.) of the top of the Hot Water Tank. T&P Drain (full size) Angle Stop Water Closet Supply Stop and Drain Outside Lawn Service Building Control Valve 16 Water Service Supply

How can your potable water system be protected from contamination by cross connection? A hose bib vacuum breaker must be installed on every hose bib located outside a building or in a garage to isolate garden hose applications thus protecting the potable water supply from contamination. Connections to potable water systems must be designed so that non-potable water, foreign matter, foreign chemicals or substances that may render the water non-potable cannot enter the system. A cross connection is a direct arrangement of piping which allows the potable water supply to be connected to a line that contains a contaminant. The purpose of a hose bib is to permit easy attachment of a hose for outside watering purposes. The ordinary garden hose is the most common offender as it can be easily connected to the potable water supply and used for a variety of potentially dangerous applications, some of which are listed below: A garden hose can be: a) left submerged in a swimming pool; b) placed in elevated locations watering shrubs; c) have chemical sprayers attached, for spraying pesticides or herbicides; d) positioned lying on the ground that may be contaminated with fertilizer, and garden chemicals; e) attached to a laundry tub with the end of the hose submerged in a tub full of detergent; or f) connected to the supply lines of bottom fed tanks, and boilers, etc. See FIGURE 16. protectoin from contamination by cross connections 1717

protection from contamination by cross connections FIGURE 16- Back Siphonage & Backflow Prevention Hose Bib Sources of Contamination What is Back Siphonage? A reversal of normal flow in the system caused by a negative pressure (vacuum or partial vacuum) in the supply piping. Hose Bib Vacuum Breaker Hose Bib Vacuum Breaker for Frost Proof Hydrants 18

For more information on this booklet please contact: Plan Examination Branch PH: (204) 986-5268 FAX: (204) 986-7307 Housing Inspection Branch PH: (204) 986-5300 FAX: (204) 942-2008 City of Winnipeg Planning, Property & Development Department 31-30 Fort Street WINNIPEG, Manitoba R3C 4X7 www.city.winnipeg.mb.ca/ppd