DS-3 Technology and Testing Overview



Similar documents
The Fundamentals of DS3

Working with T3 and T1: Technology, Troubleshooting and Fault Location

T1 Networking Made Easy

How To Understand The Technical Specifications Of Videoconferencing

How To Test A Ds1 Signal

DigiPoints Volume 1. Student Workbook. Module 5 Growing Capacity Through Technology

CTS2134 Introduction to Networking. Module 07: Wide Area Networks

Loop Telecom. Total Access Solutions for Enterprise Network, Cellular & Gateway Operator.

Dedicated Access Solutions for Internet Service Providers

Adtech Data Link Simulators.

2-port STM-1/OC-3 Channelized E1/T1 Line Card for Cisco Series Internet Routers

WAN. Introduction. Services used by WAN. Circuit Switched Services. Architecture of Switch Services

HST-3000 DS3 Service Interface Module (SIM)

Communications Analyzer

Intraplex T1 CrossConnect System & Server Installation and Operation Manual Issue 1.1, December 2001

Tellabs 1000 Multiservice Access Platform (MSAP) Secure high revenue TDM services with low cost integrated MSAP

Chapter 4 T1 Interface Card

Chapter 11: WAN. Abdullah Konak School of Information Sciences and Technology Penn State Berks. Wide Area Networks (WAN)

Cisco 2-Port and 4-Port Channelized T3 (DS-0) Shared Port Adapters

By: Mohsen Aminifar Fall 2014

INTRODUCTION TO MEDIA CONVERSION

Centralized Remote Testing for DS3/1/0 Based Services. CT650 CENTEST Wideband Test Unit

It explains the differences between the Plesiochronous Digital Hierarchy and the Synchronous Digital Hierarchy.

Interfaces and Payload Testing

1. Overview. 2. F-bit Utilization

Central Office Testing of Network Services

SDH and WDM A look at the physical layer

Lecture 12 Transport Networks (SONET) and circuit-switched networks

T3 Mux M13 Multiplexer

10 Gigabit Ethernet WAN PHY

AT&T Private Line Service OC-192 SERVICE DESCRIPTION AND INTERFACE SPECIFICATION

FURTHER READING: As a preview for further reading, the following reference has been provided from the pages of the book below:

Protocol Overhead in IP/ATM Networks

Optical Product Families

SDH and WDM: a look at the physical layer

Network+ Guide to Networks 6 th Edition. Chapter 7 Wide Area Networks

Acterna DSL Services Tester TPI 350+ Application Highlights

The Fundamentals of SONET

Public Network. 1. Relatively long physical distance 2. Requiring a service provider (carrier) Branch Office. Home. Private Network.

MSPP, MSTP and MSSP Network Elements. What s the Difference and Do We Need All of this Terminology?

Chapter 2 - The TCP/IP and OSI Networking Models

The Telephone Network

CS 5516 Computer Architecture Networks

Circuit-Switched Router Connections Nathan J. Muller

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

An ADTRAN White Paper. Integrating LAN Fax Servers over T1 and PRI Services

(Refer Slide Time: 4:45)

Monitoring and Testing

DigiPoints Volume 1. Student Workbook. Module 4 Bandwidth Management

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

ANT-20, ANT-20E Advanced Network Tester PDH MUX/DEMUX

Computer Networks. Definition of LAN. Connection of Network. Key Points of LAN. Lecture 06 Connecting Networks

Chapter 4 Connecting to the Internet through an ISP

Cisco 1-Port Channelized STM-1/OC-3 Shared Port Adapter Version 2

APPENDIX A GENERAL DEFINITIONS & SERVICE FUNCTIONS

WANs connect remote sites. Connection requirements vary depending on user requirements, cost, and availability.

Lecture 21 ISDN Integrated Digital Network.

FST-2207 TestPad T1/T3 Wireless Module Isolate network problems to speed-up wireless network testing

White Paper. OPCOM3500 Multi-Service Access Platform INTRODUCTION CHARACTERISTICS

Multiplexing. Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single physical medium.

BROADBAND AND HIGH SPEED NETWORKS

T-carrier. Two Network Interface Units. On the left with a single card, the right with two

DXC-8R/10A/30 Multiservice Access Nodes

technical note T1 Basics

Setting Up and Testing the MAX Hardware

T3 Module USER MANUAL. Part Number L1 / L1

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

FST-2802 TestPad Gigabit Ethernet Services Module Test Ethernet, Fibre Channel, and IP services using one test instrument!

Connection Services. Hakim S. ADICHE, MSc

10-3. SYSTEM TESTING AND DOCUMENTATION

How To Test For A Network Tester

A Brief Overview of SONET Technology

Telephony Fundamentals

Computers Are Your Future Prentice-Hall, Inc.

T3 E3 and T1 E1 Controller Commands on Cisco IOS XR Software

T1 Network Technology. Essentials for Successful Field Service Technicians

A Complete Solution for T3, Dual T1 and Datacom Testing

WAN Technologies Based on CCNA 4 v3.1 Slides Compiled & modified by C. Pham

Carrier Ethernet: New Game Plan for Media Converters

FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS

WAN Technology. Heng Sovannarith

Computer Networks II

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Cisco Packet-over-T3/E3 Service Module

Course 12 Synchronous transmission multiplexing systems used in digital telephone networks

The Industry's Broadest Set of DSL and Wireline Access Verification Solutions in a Portable Test Set

Ultra High-Speed SONET Fiber-Optic Transmission System

Benefits of Using T1 and Fractional T1 Carriers and Multiplexers Gilbert Held

ADSL or Asymmetric Digital Subscriber Line. Backbone. Bandwidth. Bit. Bits Per Second or bps

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Communication Networks. MAP-TELE 2011/12 José Ruela

AuroraDuet. ISDN Test Equipment ISDN. Hand-held testing for Basic & Primary Rate ISDN

White Paper: Voice Over IP Networks

Voice Modules for the CTP Series

PA-MC-T3 Multi-Channel T3 Synchronous Serial Port Adapter Enhancement

Transcription:

DS-3 Technology and Testing Overview Presented by Moti Shacham for Cincinnati Bell Technical Training Symposium September 12-14, 2000 Tel: 770-246-9662 Fax: 770-246-9733 www.telesync.com 1

OC-48/STM-16 Optical Test System ISDN PRI (DS-1, E1) and BRI Remote Test and Connectivity Units DS-1,E1, DS-3, STS-1, OC-3, OC-12 Sources and Distribution Units DS-1 and DS-3 BERTS Centralized Modem Telephone Line Testing DS-1, E1 108 Digital Loopback Test Lines SW56/ISDN and X.21/ISDN Adapters for Video Conferencing and Internet Access 2

DS-3 Technology Fundamentals DS-3 Network Overview DS-3 Framing Structure Channelized/Non-Channelized DS-3 Signal Formats Multiplexing Process Line Coding 3

DS-3 Network Elements M13 Mux DS-3 Network Interface Unit (NIU) Fiber Mux 3/3, 3/1, 3/1/0 Digital Cross-Connect Systems (DCS) 4

What is DS-3? High Capacity Private Line Service Data Transmission at 44.736 Mbps Bandwidth Equals 672 DS-0 s or 28 DS-1 s Channelized DS-3 Provides 28 DS-1 Channels Nonchannelized DS-3 Allows DS-3 End-User to Allocate Bandwidth as Needed 5

DS-3 Applications End Users LAN Interconnection Data-Intensive Mainframe-to-Mainframe Operations Broadcast-Quality Video CAD/CAM Transfer 6

DS-3 Applications Service Providers Transmit Multiple DS-1 s on a Single Line Interoffice Connections Connection of CLEC s to RBOC Network Connection of ISP s to Internet 7

DS-3 Benefits High Speed, Large Bandwidth Digital Signal Transport Can Contain 28 DS-1 s (672 DS-0 s) and Transmit Them Simultaneously Features More Flexibility than a Standard DS-1 Signal Transport Supports Wide Range of Applications Video CAD CAM Formatted as Channelized or Non-Channelized 8

DS-1 Transport via DS-3 9

DS-3 and SONET 10

DS-3 Signal Rate DS-1 to DS-2 (M12) 11

DS-3 Signal Rate DS-2 to DS-3 (M23) 12

M13 Multiplexers 13

DS-3 Framing 4704 Customer Information Bits 28 F-Bits 2 X-Bits 2 P-Bits 3 M-bits 21 C-Bits 4760 Total Bits 14

DS-3 Overhead Bits F-bits are frame alignment bits X-bits are used for alarm signaling P-bits are parity bits M-bits identify the M-frame C-bits use varies depending on frame format used 15

DS-3 Channelized/Non-Channelized Signal Frame Format M13 Asynchronous C-Bit Parity 16

DS-3 Timing 17

Comparison of M13 and C-Bit Framing M13 Framing No loop code and only one Far End Alarm Intrepretaion (Yellow) C-Bit Framing Can Interpret Alarms, FEOOF s and FEBE s, and loop individual DS-1 s and DS-3 s in the multiplexers. 18

Comparison of M13 and C-Bit Framing M13 Framing Best In-Service measurement is Parity check (only 50% accurate) and can be altered as the signal is transported through the network. C-Bit Framing In-service measurement are Parity and C-Bit Parity. C-Bit Parity will not get altered as the signal is transported through the network. 19

Comparison of M13 and C-Bit Framing C-Bit Framing Has FEAC codes available for looping DS-3 muxes, individual DS-01 s, low speed cards and for sending alarm information. 20

DS-3 Testing Applications DS-3 Out-of-Service Testing DS-3 In-Service Monitoring 21

DS-3 Out-of-Service Testing Installation DS-3 Switches Muxs DCSs ADMs Testing Done at Central Office Testing Done at CPE Requires Disabling the Network and End-to-End Test 22

DS-3 Out-of-Service Testing Measure every single bit of a transmitted signal Ensures absolute measure of performance 23

DS-3 Out-of-Service Testing Selected pattern P1 is substituted for live traffic and then transmitted over the network Error detector generates identical pattern to P1. This is called the received pattern P2. P1 and P2 are then compared and any difference means a BIT ERROR. 24

DS-3 In-Service Monitoring Timely detection of performance degradation Performed as DS-3 circuits carry live traffic Performed at C.O., DSX-3, or at DCS test ports 25

DS-3 In-Service Monitoring DS-3 Point-of-Interface (POI) carrier-tocarrier interface DS-3 Point-of-Presence (POP) Carrier-to-Customer Interface At customer DS-3 location 26

DS-3 In-Service Monitoring Monitoring M13 frame formats detects: Frame Errors Parity Errors Monitoring of C-Bit frame format detects: C-bit parity errors Far end block errors (FEBEs) 27

DS-3 Alarms LOS (Loss of Signal) LOF (Loss of Frame) AIS (Alarm Indicator Signal) Idle (DS-3 Idle Signal) Yellow (X-Bit) 28

DS-3 Alarms AIS - Alarm Indicator Signal Problem on the line somewhere behind the last multiplexer (MUX), DCS, Fiber Mux Yellow - Far End Alarm Terminating element such as an M13 Mux loses framing on its received DS-3 signal or receives an AIS signal 29

DS-3 Alarms 30

DS-3 Alarms Idle Signal DS-3 Idle signal allows DS-3 circuits to stay out of service without triggering network alarm 31

DS-3 Out-of Service Testing Loop the DS-3 at the far end Loop the DS-1s at the far end 32

DS-3 Out-of-Service Testing Perform when installing DS-3 circuits Prevents call-backs by proactively verifying: Configuration of DS-3 NEs responsible for DS-3 signal transmission Quality of transmitted signal and circuit connections Correct synchronization of DS-3 circuit 33

Connecting TSI-4515 for Out-of-Service Testing 34

DS-3 Out-of-Service Testing End-to-End Transmits an end-to-end or looped back PRBS pattern for commissioning Transmits single errors for continuity checks 35

DS-3 Out-of-Service Testing End-to-End 36

DS-3 In-Service Performance Monitoring Using FEBEs FEBE - Far End Block Error C-Bit parity framing allows end-to-end performance monitoring of DS-3 circuits Verify end-to-end performance of DS-3 circuits while it is in service 37

DS-3 FEBE Errors 38

DS-3 In-Service Monitoring Provides in-service monitoring of F-bits, C- bits, X-bits, P-bits, C-parity bits and Far End Block Errors Counts all error categories simultaneously Notifies operator of thresholds and end of test. 39

DS-3 Bi-Directional In-Service Monitoring 40

DS-3 In-Service Long Term Monitoring 41

DS-3 In-Service Circuit Test 42

DS-3 In-Service Test with DS-1 Drop/Insert Drop the DS-1 channel from the received DS-3 signal and perform complete DS-1 bit error rate testing Insert an internally generated DS-1 test pattern or loop code Perform out-of-service DS-1 testing over live DS- 3 signal 43

DS-3 In-Service Test with DS-1 Drop/Insert 44

DS-3/DS-1 Circuit Test Test DS-1s within DS-3 Service 45

TSI-4515 DS-3/DS-1 Drop/Insert with BERTS Monitor and test DS-3 channels in the 3/1, 3/3, 3/1/0 DCS system Monitor and test DS-3 at any DSX-3 locations Used at DS-3 Point-of-Interface (POI) and Pointof Presence (POP) locations for long term monitoring and testing Installed in an CO. 19/23 rack mount Optional portable chassis 46

TSI-4515 DS-3/DS-1 Drop/Insert with BERTS Provide dual DS-3(TX/RX) performance monitoring and testing plus DS-1 Drop and Insert RS-232 interface for full remote control and monitoring from PC or terminal 15 Minute error bins over 24 hour period allows the unit to be used for long term monitoring of DS-3 and DS-1 circuits 47

TSI-4515 DS-3/DS-1 Drop/Insert with BERTS DS-1 signals can be routed to the TSI-1524 DS-1 Multichannel test unit for DS-1 measurements Cost effective solution of dropping and inserting DS-1 signals into the DS-3 network Test and monitor M13 or C-bit DS-3 signals 48

TSI-4515 DS-3/DS-1 Drop/Insert with BERTS Modular configuration can test up to 20 DS-3 s using 10 interconnecting chassis through a single RS-232 interface Can be used as a dual bridging repeater when the Thru Mode is selected Small size - 1.75 H x 11 W x 8.5 D Light weight - 3 pounds Most economical solution for dual DS-3 testing and monitoring 49

Thank You For Joining US! Look to TELESYNC For: OC-48/STM-16 Optical Test System ISDN PRI (DS-1, E1) and BRI Remote Test and Connectivity Units DS-1,E1, DS-3, STS-1, OC-3, OC-12 Sources and Distribution Units DS-1 and DS-3 BERTS Centralized Modem Telephone Line Testing DS-1, E1 108 Digital Loopback Test Lines SW56/ISDN and X.21/ISDN Adapters for Video Conferencing and Internet Access 50