Integrated Network Monitoring



Similar documents
Monitoring the HP Blade Servers

How To Manage A Network With Kepware

Monitoring Traffic manager

DC Cook Plant Process Computer Replacement Project

TNT SOFTWARE White Paper Series

Configuring and Monitoring Hitachi SAN Servers

Applicable for: Secure Access Service MAG Series Junos Pulse Gateway Access Control Service. Juniper Networks SNMP Monitoring Guide

Monitoring the Hitachi Storage Devices

OMNITURE MONITORING. Ensuring the Security and Availability of Customer Data. June 16, 2008 Version 2.0

Monitoring QNAP NAS system

User s Manual. Management Software for ATS

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW

How To Set Up Foglight Nms For A Proof Of Concept

How To Understand and Configure Your Network for IntraVUE

DF to-2 SATA II RAID Box

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

THE SNMP PROTOCOL THE SNMP REQUEST MIB SATELLAR 2DS/20DS SIMPLE NETWORK MANAGEMENT PROTOCOL SATELLAR MANAGEMENT WITH SNMP GET AND SET SMART RADIO

Network Monitoring Comparison

Monitoring Network Elements

System 800xA PC, Network, and Software Monitoring Operation

What's new in SAN Health Diagnostics Capture 4.0

How To Get Started With Whatsup Gold

PANDORA FMS NETWORK DEVICE MONITORING

Lab - Configure a Windows 7 Firewall

Version 4.1 June Xerox Device Agent (XDA) Lite Security and Evaluation Guide

Rapid Assessment Key v2 Technical Overview

The best network information. COPA-DATA know-how: SNMP with zenon

Dell OpenManage SNMP Reference Guide Version 8.0.1

mbits Network Operations Centrec

Configuring Dell OpenManage IT Assistant 8.0 to Monitor SNMP Traps Generated by VMware ESX Server

orrelog SNMP Trap Monitor Software Users Manual

VCE Vision Intelligent Operations Version 2.5 Technical Overview

PANDORA FMS NETWORK DEVICES MONITORING

echomountain Enterprise Monitoring, Notification & Reporting Services Protect your business

What s new in ProactiveWatch 2.1!

MANAGING NETWORK COMPONENTS USING SNMP

CA Nimsoft Monitor. snmptd Guide. v3.0 series

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

Simple Network Management Protocol

Assignment One. ITN534 Network Management. Title: Report on an Integrated Network Management Product (Solar winds 2001 Engineer s Edition)

1 Data Center Infrastructure Remote Monitoring

Integration with CA Application Delivery Analysis

WHITE PAPER September CA Nimsoft For Network Monitoring

HP Server Management Packs for Microsoft System Center Essentials User Guide

VCE Vision Intelligent Operations Version 2.6 Technical Overview

Deploying the BIG-IP LTM with the Cacti Open Source Network Monitoring System

Active Management Services

Lab - Configure a Windows Vista Firewall

Using The Paessler PRTG Traffic Grapher In a Cisco Wide Area Application Services Proof of Concept

Lecture 12: Network Management Architecture

Maximizing return on plant assets


vsphere Client Hardware Health Monitoring VMware vsphere 4.1

Syslog Server Configuration on Wireless LAN Controllers (WLCs)

Product Guide CM-Relay

WhatsUp Gold v11 Features Overview

Monitoring DoubleTake Availability

Network Management and Monitoring Software

These options allow you to define baseline settings for how scanning will occur on your network

Network Monitoring with SNMP

Cisco UCS and Fusion- io take Big Data workloads to extreme performance in a small footprint: A case study with Oracle NoSQL database

WHITE PAPER OCTOBER CA Unified Infrastructure Management for Networks

PagePack Assistant 3.10 Security and Evaluation Guide

SNMP Test er Manual 2015 Paessler AG

JetAdvice Manager Data Collector v Date:

Monitor the Cisco Unified Computing System

Configuring and Monitoring Citrix Access Gateway-Linux Servers. eg Enterprise v5.6

QUESTION: 1 Which of the following are valid authentication user group types on a FortiGate unit? (Select all that apply.)

WorkstationST* Network Monitor

CA Nimsoft Monitor. snmpcollector Release Notes. All versions

Network Management Card. User Manual

ALTIRIS. Network Discovery 6.0 SP4 Help

Post Genie TM WebMail Server 2400/2208R

Innovative Electronics for a Changing World INDEX

SystemWatch SM. Remote Network Monitoring

OM2012 Network Monitoring. Phil Bracher Sr. Premier Field Engineer Microsoft Corporation

Quick Start for Network Agent. 5-Step Quick Start. What is Network Agent?

Introduction to Network Management

Maintaining Non-Stop Services with Multi Layer Monitoring

Ambient Temperature In Range Probe X

IT Service Level Management 2.1 User s Guide SAS

Auditing the LAN with Network Discovery

Monitor all of your critical infrastructure from a single, integrated system.

This document explains how to use your Web Browser to configure the 100BaseT Print Server models

Aerohive Networks Inc. Free Bonjour Gateway FAQ

Network Monitoring with SNMP

Topics. Generals SNMP Software SNMP SkyWAN Work on redundant unit (Aruba) FAD Work on redundant unit (Aruba) Graphs

Sentry Bulldog Shutdown Management Software (For UNIX Series)

This document explains how to use your Web Browser to configure the 100BaseT IOPRINT+ Print Server models. Connecting to the IOPRINT+ Print Server

VTrak SATA RAID Storage System

Tenor SNMP Implementation

TELE 301 Network Management

Configuring SNMP Monitoring

How To Run A Hosted Physical Server On A Server At Redcentric

Transcription:

Integrated Network Monitoring Robert Ammon / SCIENTECH SCIENTECH, LLC August 2006

Overview What is R*TIME s Integrated Network Monitoring function? What is covered by this presentation?

R*TIME Integrated Network Monitoring Provides the ability to: acquire operational parameters and data from PPC system components via SNMP save the acquired data to database points (analog and digital)

R*TIME Integrated Network Monitoring Acquired data can be used for: determine the operational status of health of the monitored system component monitor system performance metrics provide feedback on system performance or health to system administrator personnel

R*TIME Integrated Network Monitoring Availability: R*TIME Server V 12.3 Unix / Windows R*TIME Server V 12.2 Windows (PINGP only system demonstration) Can be added to other R*TIME Server versions as an add-on

SNMP R*TIME Integrated Network Monitoring uses SNMP as the communication protocol ANY PPC system component that has a network connection and provides an SNMP interface can be monitored Not limited to just system networking components (can be used to monitor servers, workstations, printers, etc.)

Commissioning Details What system components will be monitored? Servers Workstations Printers Switches Serial Hubs Network Transceivers

Commissioning Details What parameters will be monitored for each system component? Parameters that indicate component or equipment degradation that indicates a possible pending failure BEFORE it becomes an equipment failure Parameters that indicate loss of system redundancy BEFORE there is a lost of system functionality

Commissioning Details What parameters will be monitored for each system component? Servers CPU Utilization Memory Utilization Disk Space Utilization Temperature Power Supply Status Fan Status RAID Drive Status NIC Performance and Status

Commissioning Details What parameters will be monitored for each system component? Workstations CPU Utilization Memory Utilization Disk Space Utilization NIC Performance and Status

Commissioning Details What parameters will be monitored for each system component? Switches Port status, throughput and errors Switch status and health Link status and health

Commissioning Details What parameters will be monitored for each system component? Printers Printer status and health Other Components Component status and health

Commissioning Details What additional parameters will be derived from raw parameters received from the monitored components? Derived parameters that summarize a type of equipment performance or health

Commissioning Details What additional parameters will be derived from raw parameters for each system component? Servers Average CPU Utilization Average Temperature Composite Power Supply Status Composite Fan Status

Commissioning Details What additional parameters will be derived from raw parameters for each system component? Switches Port throughput and errors Switch status and health Link status and health

Commissioning Details What additional parameters will be derived from raw parameters for each system component? Printers Printer status and health Other Components Component status and health

Commissioning Details How will abnormal component performance or health be indicated? PPC Alarm Display? Provides immediate feedback to plant personnel Does not require E mail or pager access like Notification Monitoring Requires monitoring be performed on the PPC servers or a downlink from the PSS

Commissioning Details How will abnormal component performance or health be indicated? R*TIME Notification Monitor? Does not require operations personnel action. Can be targeted directly to the PPC system support or administrator personnel Requires E mail or pager access Normally requires monitoring be performed on the PSS

R*TIME Integrated Network Monitoring Fundamentals Network Visibility Component being monitored must be network visible from the computer doing the monitoring (direct network attachments or non routable subnets can reduce network visibility) Single Program Implementation Supports single or multiple instances (monitoring can be segregated if desired) INI File Definition SNMP Parameters SNMP Version OIDs Parameter scaling and conversion

INI File Parameters [CONFIG] One section per file NUM_DEVICES specifies the number of detail devices sections normally the number of devices to monitor unless a device is described in more than one section DEVICExx one entry per NUM_DEVICES specifies device detail section name FREQUENCY monitoring frequency in number of seconds SNMP request send to the devices at this rate devices queried in device order not exact, timing can be affected by unresponsive devices MILLISECONDS_PER_READ rate in milliseconds that SYSMON looks for device SNMP responses MAX_READ_RETRIES number of SNMP response timeouts before the device is declared non responsive MAX_READ_FAILS Number of consecutive device non responses before a message is logged

INI File Parameters [DEVICEname] One section per NUM_DEVICES specified in the [CONFIG] section Section linkage is via the DEVICExx parameter in the [CONFIG] section Device_Name Logical device description Device_Status Digital data point name where the device communication status is recorded SNMP_Version SNMP version supported by the device (1 or 2) Community SNMP communisty name required to communicate with the device

INI File Parameters [DEVICEname] (cont.) StatusOnly Device status flag. If non zero, only record the device status into the Device_Status point (no detail OIDs defined) NUM_OIDS Number of device parameters to acquire OIDxx OID to the information on the device you want to retrieve POINT_NAME Analog or Digital Point name to store the device information into MULT_FACT Device data multiplication factor SHIFT_FACT Device data shift factor

SNMP Parameters SNMP Version Specified for each device in the device detail section in the INI file OIDs Numerical number that specifies the device parameter that is being retrieved Determined by reviewing the MIB file or using a tool like GETIFS Parameter scaling and conversion Specified in the INI file and used to convert device data to different units or to convert the returned data value to acceptable ranges (i.e. convert state values from 1-4 to 0-3 for digital points)

Integrated Network Monitoring Implementation Prairie Island ERCS Background Unit 1 Systems Unit 2 Systems Simulator Systems Development Systems Plant Server Systems (two, each containing Unit 1 and Unit 2) Integrated Network (all systems connected into a single integrated network)

Integrated Network Monitoring Implementation Prairie Island ERCS Implementation Monitoring performed on PSS-A and PSS-B All other systems monitored Each PSS system monitors all other systems (dual monitoring) Monitored data stored into a separate System Monitoring database containing data for all systems (database not separated by unit like plant systems) System Monitoring database resident on both PSS systems (requires multiple database updates)

Integrated Network Monitoring Implementation Equipment Monitored Compaq DL380 server computers (14 devices total) Compaq D530 workstation computers (16 devices total) HP ColorLaser Jet 3550 printers (8 devices total) Cisco 3750 switches (22 devices total) Equinox Serial Hubs (7 devices total)

Integrated Network Monitoring Implementation Parameters Monitored Compaq DL-380 server computers Chassis Temperature 5 values per server Analog values (deg F) Celsius value converted to Fahrenheit Fan Status 8 per server Digital values Power Supply Status 2 per server Digital values RAID Drive Status 2 per server State values (saved as analog points)

Integrated Network Monitoring Implementation Parameters Computed Compaq DL-380 server computers Average Chassis Temperature Composite Fan Status Power Supply Status 2 per server Digital values RAID Drive Status 2 per server State values (saved as analog points)

Integrated Network Monitoring Implementation Parameters Monitored Compaq D530 workstation computers NIC Throughput 2 ports per workstation Analog values

Integrated Network Monitoring Implementation Parameters Monitored HP ColorLaser Jet 3550 printers Black Cartridge Cyan Cartridge Magenta Cartridge Yellow Cartridge Transfer Kit Fuser Kit Percent Remaining Analog values

Integrated Network Monitoring Implementation Parameters Monitored Cisco 3750 switches Port Bandwidth Input and Output Errors Input and Output Throughput 28 ports per switch Analog values

Integrated Network Monitoring Implementation Parameters Computed Cisco 3750 switches Total Throughput 28 ports per switch Analog values

Integrated Network Monitoring Implementation Parameters Monitored Equinox Serial Hubs Network Bandwidth Network Input and Output Throughput Network Input and Output Errors Analog values

Integrated Network Monitoring Implementation Prairie Island Implementation Details Total Components Monitored = 105 Total Number of Data Points = 4153 Analog points = 3792 Digital points = 361 Total Number of Computed Points = 754 Total Number of Alarmed Points = 416 Total Number of INI File Lines = 16430

Integrated Network Monitoring Implementation Implementation Issues Monitored Parameters Parameters available depend upon the OEMs implementation of the SNMP interface. Can vary widely from manufacturer to manufacturer MIB files not always provided and sometimes are not standards compliant Many times must monitor detailed information to verify equipment health OID numbering Not standardized from server manufacturer to server manufacturer, even for identical parameters Can different depending upon OEM model or software / firmware version

Integrated Network Monitoring Implementation Implementation Issues Lots of Configuration Required Cut and Paste of INI files and Database points can be error prone INI file becomes large very fast Notification Monitoring required for maximum benefit brings firewall configuration issues in play

Version 2.0 Implementation GUI interface for: OID selection database point selection / creation INI file entry definition Notification Monitoring interface Named equipment library (define one, reuse many) Others?