Electronic Raw Data and the Use of Electronic Laboratory Notebooks



Similar documents
Auditing Chromatographic Electronic Data. Jennifer Bravo, M.S. QA Manager Agilux Laboratories

MHRA GMP Data Integrity Definitions and Guidance for Industry March 2015

MHRA GMP Data Integrity Definitions and Guidance for Industry January 2015

Assuring E Data Integrity and Part 11 Compliance for Empower How to Configure an Empower Enterprise

Designing a CDS Landscape that Ensures You Address the Latest Challenges of the Regulatory Bodies with Ease and Confidence

Full Compliance Contents

Nova Southeastern University Standard Operating Procedure for GCP. Title: Electronic Source Documents for Clinical Research Study Version # 1

WinKQCL 5 Endotoxin Detection and Analysis Software We Analyze Endotoxin Data Every Day

Manual 074 Electronic Records and Electronic Signatures 1. Purpose

Tools to Aid in 21 CFR Part 11 Compliance with EZChrom Elite Chromatography Data System. White Paper. By Frank Tontala

Computerised Systems. Seeing the Wood from the Trees

21 CFR Part 11 Compliance Using STATISTICA

Review and Approve Results in Empower Data, Meta Data and Audit Trails

DO MORE AND DO IT WITH CONFIDENCE. Empower 3 Chromatography Data Software

QUESTIONS FOR YOUR SOFTWARE VENDOR: TO ASK BEFORE YOUR AUDIT

Validating Enterprise Systems: A Practical Guide

Validating Methods using Waters Empower TM 2 Method. Validation. Manager

Good Clinical Laboratory Practice (GCLP) An international quality system for laboratories which undertake the analysis of samples from clinical trials

Welcome Computer System Validation Training Delivered to FDA. ISPE Boston Area Chapter February 20, 2014

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Clinical database/ecrf validation: effective processes and procedures

Connections to External File Sources

Clinical Data Management (Process and practical guide) Nguyen Thi My Huong, MD. PhD WHO/RHR/SIS

THe evolution of analytical lab InForMaTICs

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

Using the Thermo Scientific Dionex Chromeleon 7 Chromatography Data System (CDS) to Comply with 21 CFR Part 11. Compliance Guide

A Complete Drug Stability Program. Stability Lab Information Manager SL IM

EMA Clinical Laboratory Guidance - Key points and Clarifications PAUL STEWART

Analytical Test Method Validation Report Template

Thermal Analysis. Subpart A General Provisions 11.1 Scope Implementation Definitions.

COMPLIANCE BY DESIGN FOR PHARMACEUTICAL QUALITY CONTROL LABORATORIES INSIGHT FROM FDA WARNING LETTERS

Waters Empower Software Seamlessly Manages Regulated Data to Aid in 21 CFR Part 11 Compliance

Assessment of Vaisala Veriteq vlog Validation System Compliance to 21 CFR Part 11 Requirements

Statistical Operations: The Other Half of Good Statistical Practice

Streamlining the drug development lifecycle with Adobe LiveCycle enterprise solutions

MHRA Data Integrity Guidance and Expectations Document

MOVING THE CLINICAL ANALYTICAL ENVIRONMENT INTO THE CLOUD

Software Validation in Clinical Trial Reporting: Experiences from the Biostatistical & Data Sciences Department

From paper to electronic data

Barnett International and CHI's Inaugural Clinical Trial Oversight Summit June 4-7, 2012 Omni Parker House Boston, MA

ROLES, RESPONSIBILITIES AND DELEGATION OF DUTIES IN CLINICAL TRIALS OF MEDICINAL PRODUCTS

Considerations for Management of Laboratory Data

Data Management and Good Clinical Practice Patrick Murphy, Research Informatics, Family Health International

PERFORMANCE EVALUATION AUDIT CHECKLIST EXAMPLE. EIIP Volume VI

Why System Suitability Tests Are Not a Substitute for Analytical Instrument Qualification

INTRODUCTION. This book offers a systematic, ten-step approach, from the decision to validate to

LabArchives Electronic Lab Notebook:

Medical Cannabis Laboratory Approval Program

Compliance Control Procedure Execution Management System Reduces Compliance Risks by 10X

Lean Process Improvements for the GMP Laboratory

Results Count LABWARE ELN. LabWare ELN. LabWare

Good Documentation Practices

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

No Page 1 of 5. Issue Date 4/21/2014

21 CFR Part 11 Electronic Records & Signatures

CLINICAL DATA MONITORING PLAN (CDMoP) PROTOCOL # [0000] [TITLE]

Remote Monitoring of Clinical Trials and EMRs

OECD DRAFT ADVISORY DOCUMENT 16 1 THE APPLICATION OF GLP PRINCIPLES TO COMPUTERISED SYSTEMS FOREWARD

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Using SharePoint 2013 for Managing Regulated Content in the Life Sciences. Presented by Paul Fenton President and CEO, Montrium

Good Research Practice

Testing Automated Manufacturing Processes

QUALITY CONTROL AND QUALITY ASSURANCE IN CLINICAL RESEARCH

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

The BlazeLIMS Family of Products Functional Specs V5.5

1 / 18. BookitLab Core Facility Management Solution. White Paper V6.5Pb. Prog4biz Ltd Feb 2015

TEMPLATE DATA MANAGEMENT PLAN

Data Management Unit Research Institute for Health Sciences, Chiang Mai University

Guidance to Research Ethics Committees on Initial Facility Assessment

Guidance for Industry

Managing & Validating Research Data

GLP vs GMP vs GCP Dominique Pifat, Ph.D., MBA The Biologics Consulting Group

NC SBI QUALITY ASSURANCE PROGRAM

Overview. Disasters are happening more frequently and Recovery is taking on a different perspective.

Section 1 Project Management, Project Communication/Process Design, Mgmt, Documentation, Definition & Scope /CRO-Sponsor Partnership

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

IMP management at site. Dmitry Semenyuta

Xcalibur. Foundation. Administrator Guide. Software Version 3.0

Spectroscopy Configuration Manager (SCM) Software. 21 CFR Part 11 Compliance Booklet

Document Change Control

4Sight Calibration Management Software

Data Management Implementation Plan

Considerations When Validating Your Analyst Software Per GAMP 5

This interpretation of the revised Annex

Empower TM 2 Software

Laboratory Data Management Systems

Waters Empower 2 Software Seamlessly Manages Regulated Data to Aid in 21 CFR Part 11 Compliance

Regulatory Asset Management: Harmonizing Calibration, Maintenance & Validation Systems

GLP Records Storage and Retrieval

DeltaV Capabilities for Electronic Records Management

OECD SERIES ON PRINCIPLES OF GOOD LABORATORY PRACTICE AND COMPLIANCE MONITORING NUMBER 10 GLP CONSENSUS DOCUMENT

Document and Record Control in a Hospital Clinical Laboratory

Guidance for Industry Computerized Systems Used in Clinical Investigations

OPERATIONAL STANDARD

GCP - Records Managers Association

A Guide to Archiving of Electronic Records

Reflection paper for laboratories that perform the analysis or evaluation of clinical trial samples

rsdm and 21 CFR Part 11

Guidance for electronic trial data capturing of clinical trials

Transcription:

7th WRIB- M-2 Workshop Electronic Raw Data and the Use of Electronic Laboratory Notebooks Ron Shoup

Outline for Today Raw Data- defining it, creating it, and keeping it for posterity Hybrid Data- paper, electronic Data Integrity- regulatory concerns from recent inspections Electronic Laboratory Notebooks Introducing the Concept Capabilities and Advantages Implementation- one case study Future View

Defining Raw Data Simplest form- visual reading of a measurement, recorded on paper, with attribution. Raw data: Earliest original recorded observation of a process, event, or state. Primary measurement from an instrument or tool Measurement that is not changed or replaced by secondary operations performed later, through human intervention. The point of origin for any post-measurement processing

Examples of Raw Data Transcription of mass reading from a balance to a lab notebook or paper form by the operator in real time Observation by phlebotomist that blood sample from Subject 123 was drawn at 10:30 AM Operating conditions for a mass spectrometer as recorded in lab notebook Temperature and humidity data in archives data logger

Raw Data

Not raw data!

CDS and MS Systems: Raw Data Instrument Data Acquisition Parameters recorded at time of sample injection Detector Response vs. Time Simplest, earliest record of the run Detector signal intensity for a given mass transition, wavelength, or potential Captured according to the Data Acquisition parameters before any further manual processing Permits operator to separate processed data files from raw data for complete transparency Allows any subsequent operator to reconstruct processed data from the same original datafile.

Data Integrity Capture the original observation as raw data, at the moment it was observed. Capture it once- no transcriptions, no copies. Who was the observer and when did they record the data? Any changes? Reasons? Who made the change? Who reviewed the change? Audit trails! How to lock the data and preserve for posterity?

Compliance for electronic records: Access must be limited and controlled 21 CFR Part 11 Systems validation appropriate for the level of risk Electronic signatures Electronic records equivalent to paper records Written policies and SOP s to hold users accountable Training, education, and experience of staff Quality System to control systems and data

21 CFR Part 11 systems gone awry: paper vs electronic Q: When may be paper records be used as an alternate means of preserving electronic records? A: The printouts must preserve the accuracy, completeness, content, and meaning of the electronic source record- FDA August 2003 Guidance on Part 11 Hybrid systems are the most difficult to organize and maintain for complete transparency.

Interpretation Problems with Part 11 We define our printouts as the raw data. The electronic files are really just the means to create the raw data. We archive only the PDF s of the paper outputs as our raw data. We have a Part 11 compliant system. All files are therefore trustworthy. We don t routinely review audit trails in QAU. Audit trails are too detailed for even the simplest data. We had to give administrator access to all lab staff in order to use the software effectively.

FDA Inspection Comments Failure to use audit trails to track any changes to the study data. Failure to indicate the reason for change to raw data. The data system allows users to erase and overwrite raw data due to widespread administrator rights. Non compliance with electronic signatures policy Lack of controls to prevent tampering with data Lack of management oversight to insure data integrity No process for using audit trails for the review of original and processed data Biased integrations without traceability; disabling audit trails

Electronic Laboratory Notebooks An electronic lab notebook is a computer program designed to replace paper laboratory notebooks.

The issues with paper: Searching for information in paper systems Printed methods and companion paper forms Detecting disconnects between various paper systems (equipment calibration expiration vs. use in study) Knowing when data is truly created in a paper system Knowing whether results are built from secured and validated resources Exhaustive QC checks to verify data

Why implement an ELN?: Attribution of every data entry Versions of every form during completion Electronic signature of originator and reviewer Integrity of data inside DB, no loose files to collect Completeness- all records at your fingertips Searchability, filtering Ability to: Control forms and process Control access to the process Supervise data entries in real time for errors and noncompletes

4Q 2009 1Q 2010 2Q-4Q 2010 1Q-2Q 2011 One Implementation Historical Background on AITB s ELN Implementation Completed evaluation of 3 ELN products, purchased IDBS E-Workbook Extensive initial training; wrote user requirements for approximately 20 workflows to create templates Template creation, administrative operations decisions Validation of templates and hierarchy; final SOPs 2013 Over 60 templates now validated

ELN Terminology Validated Template- a predefined set of tables, requiring the same information every time (similar to a paper form) that has been tested and approved. Experiment- Any information placed in the ELN; placing a word document into the ELN is an experiment Any process performed using a validated template; for example: balance checks, audits, equipment maintenance Version History- the history of saves performed on an experiment

Empty template ready for use in experiment:

Completed experiment:

Hierarchical controls: Only approved templates allowed for regulated studies Only designated method(s) can be applied to the study Folders define one s ability to execute, and where to execute All staff can view any experiment, at any stage

Seamless connection to Watson New sponsor in Watson sponsor hierarchy built in ELN New study in Watson study hierarchy built in ELN New analytical run in Watson new run built in ELN under Run Organizer folder of study Standardized sample names for all types of normal and validation samples

Watson data autoloaded into validation experiment:

Recovery calculations, from knowing the run number and sample identifiers

Components for Audit By Exception

4 Versions of an Evolving Record: Version History /Root/QA/Quality Sponsor Correspondence/0025/Vendor Survey Form 17 September 2011

Audit Trail Example: Equipment Maintenance Audit Logs /Root/AIT Bioscience/Common Equipment/Executed Common Equipment Experiments/EQM-BEQ.1113-21-Jun-2011-003

Audit Trail Example: Equipment Maintenance- oil change in pump Audit Logs

Sources of Bioanalytical Data Facility Records Training Records Study Records Software development and validation Software change control and administration Metrology records Environmental controls Archives- access, in/out Reverifications depending on risk assessment Quality auditsto management Regulatory training Qualifications, CV, job description SOP and other internal training Meetings, workshops, shortcourses Quality auditsto management Protocols, sample analysis and validation plans Sample management Reagents, sample preparation Instrumental analysis and data processing Scientific review and acceptance Reporting Quality auditsto management

Evolution of Good Data Practices 1990: Lab notebooks, chromatography integrators, one-shot integrations. 1995: CDS, diskettes with raw and processed files, paper printouts, bankers boxes 2000: LIMS, data files on local drives, PDFs, CDs 2005: SDMS/database to hold raw and processed files and metadata, searchable. 2007: ELN/database to capture all data and records, no paper forms, with complete version control and audit trails in place.

Ron Shoup rshoup@aitbioscience.com 317-715-8826 AIT Bioscience, LLC 7840 Innovation Blvd Indianapolis, IN 46278