SWANSON. hammertoe IMPLANT. surgical technique presented by LOWELL SCOTT WEIL, DPM



Similar documents
SWANSON. Titanium Radial Head Implant

HUNTER TENDON IMPLANTS

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

METAL HEMI. Great Toe Implant SURGICAL TECHNIQUE

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

John M. Sigle, DPM, FACFAS Foot & Ankle Center of Illinois (217)

Arthroscopy of the Hand and Wrist

Integra. MCP Joint Replacement PATIENT INFORMATION

(English) NEXUS SPINE SPACER SYSTEM

BONE PRESERVATION STEM

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

Achilles Tendon Repair, Operative Technique

How To Fix A Radial Head Plate

Mini TightRope CMC Surgical Technique

Lentur Cable System. Surgical Technique

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

Spinal Arthrodesis Group Exercises

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

Posterior Referencing. Surgical Technique

Exeter X3 RimFit. Acetabular Cup Surgical Protocol

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

CLAW II. Polyaxial Compression Plating System SURGIC A L T ECHNIQUE

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

INJURIES OF THE HAND AND WRIST By Derya Dincer, M.D.

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

Chapter 30. Rotational deformity Buddy taping Reduction of metacarpal fracture

.org. Arthritis of the Hand. Description

How To Perform An Elbow Operation

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

Integra. Subtalar MBA and bioblock Implant SURGICAL TECHNIQUE

Bard * PerFix * Plug. Technique Guide. A Modified Technique with the. Open Inguinal Hernia Repair

DARCO MRS. Locked Plating System for Reconstructive Rearfoot Surgery

Bankart Repair using the Smith & Nephew BIORAPTOR 2.9 Suture Anchor

Systemic condition affecting synovial tissue Hypertrohied synovium destroys. Synovectomy. Tenosynovectomy Tendon Surgery Arthroplasty Arthrodesis

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.

Tissue Reinforcement with Strattice Reconstructive Tissue Matrix following Correction of Severe Breast Deformity

Integra. Subtalar MBA Implant

Your Practice Online

Introduction to the Bertram Hip Spacer

Clarification of Medicare Benefits Schedule rules for the Transport Accident Commission and WorkSafe Victoria

Zimmer PSI Knee System For Use with Persona The Personalized Knee System Surgical Technique

Knotilus TM. Anchor Instability Repair. Technique Guide

THE WRIST. At a glance. 1. Introduction

Abdominal Pedicle Flaps To The Hand And Forearm John C. Kelleher M.D., F.A.C.S.

ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine

Shoulder Arthroscopy

Ankle Arthritis Treatment in Worker Compensation The New Gold Standard ~ Total Ankle Replacement

Zimmer Small Fragment Universal Locking System. Surgical Technique

Metal-on-Metal Hip Systems

External Fixation Systems IMPORTANT MEDICAL INFORMATION

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

INFUSE Bone Graft. Patient Information Brochure

The information contained in this document is intended for healthcare professionals only.

Minimally Invasive Hip Replacement through the Direct Lateral Approach

Total elbow joint replacement for rheumatoid arthritis: A Patient s Guide

IMPLANT MENTOR EFFECTIVE JANUARY 2012 BREAST IMPLANTS NOT FOR DISTRIBUTION IN USA APPROVED FOR EMEA REGION. Mentor Worldwide LLC Rev C

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

Total Shoulder Arthroplasty

Quick Facts about Breast Augmentation with IDEAL IMPLANT Saline-filled Breast Implants

it s time for rubber to meet the road

Does the pain radiating down your legs, buttocks or lower back prevent you from walking long distances?

Total Elbow Arthroplasty and Rehabilitation

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

Get the Facts, Be Informed, Make YOUR Best Decision. Pelvic Organ Prolapse

At the completion of the rotation, the resident will have acquired the following competencies and will function effectively as:

chronos BOne VOid Filler Beta-Tricalcium Phosphate (b-tcp) bone graft substitute

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Rheumatoid Arthritis of the Foot and Ankle

The Total Ankle Replacement

Hip Replacement Surgery Understanding the Risks

Information for the Patient About Surgical

Cormet Hip Resurfacing System

Cranial/Neurosurgical Implants

Case Log Guidelines for Foot and Ankle Orthopaedic Surgery Review Committee for Orthopaedic Surgery

OVER 45 YEARS TEXTILE GRAFT TECHNOLOGY EXPERIENCE MAQUET THE GOLD STANDARD

A Patient's Guide to Arthritis of the Finger Joints

Breast Augmentation Amsterdam Plastic Surgery Breast Augmentation Overview

Patient Guide to Neck Surgery

Scaphoid Non-union. Dr. Mandel Dr. Gyomorey. May 3 rd 2006

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

Labral Repair. Surgical Protocol by Ronald Glousman, M.D. and Nicholas Sgaglione, M.D.

CPME Memorandum Proper Logging of Surgical Procedures November 15, 2012

Aestheticare Cosmetic Surgery Institute Dr. Ronald E. Moser Rancho Viejo Rd. San Juan Capistrano, CA (800)


INTERNATIONAL MEDICAL COLLEGE

Patient Guide to Lower Back Surgery

Residency Competency and Proficiency Statements

Titanium Wire with Barb and Needle. For canthal tendon procedures.

Integumentary System Individual Exercises

Minimally Invasive Spine Surgery

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

KNEE LIGAMENT REPAIR AND RECONSTRUCTION INFORMED CONSENT INFORMATION

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

The Right Choice. Exeter. total hip system

Mini Medical School _ Focus on Orthopaedics

BREAST IMPLANTS (enlargement, augmentation) Dr. Benjamin Van Raalte TYPES OF IMPLANTS saline round implants high profiles low profile shaped

Transcription:

hammertoe IMPLANT surgical technique presented by LOWELL SCOTT WEIL, DPM

SWANSON hammertoe IMPLANT as described by Lowell Scott Weil, DPM general PRECAUTIONS The potential for complications or adverse reactions with any implant can be minimized by following the instructions for use provided in product literature. It is the responsibility of each surgeon using implants to consider the clinical and medical status of each patient and to be knowledgeable about all aspects of implant procedure and the potential complications that may occur. The benefits derived from implant surgery may not meet the patient s expectations or may deteriorate with time, necessitating revision surgery to replace the implant or to carry out alternative procedures. Revision surgeries with implants are common. The patient s mental status must also be considered. Willingness and/or ability to follow post operative instructions may also impact the surgical outcome. Surgeons must balance many considerations to achieve the best result in individual patients. IF EXCESSIVE LOADING CANNOT BE PREVENTED, AN IMPLANT SHOULD NOT BE USED. One of the goals of implant surgery is to minimize production of wear particles. It can never be eliminated because all moving parts, e.g., implants which articulate against bone, wear to some degree. In an implant arthroplasty, clinically significant wear can result from normal biomechanical forces. Abnormal or excessive force will further increase clinically significant wear. Abnormal force loading may be caused by: Uncorrected instability Oversized implant Inadequate soft tissue support Implant malposition Excessive motion Uncorrected or recurrent deformity Patient misuse or overactivity Intra-operative fixation one

Some preventive measures to consider to minimize the potential for complications: Follow guidelines for indications and contraindications provided below: Identify prior pathology Stabilize collapse deformities Bone graft pre-existing cysts Use a properly sized implant Avoid K-wires and sutures through the implant If complications develop, possible corrective procedures include: Implant removal Implant removal Synovectomy Bone grafting of cysts Limited intertarsal fusion Replacement of the implant Removal of the implant with fusion of the joint Clinical results depend on surgeon and technique, preoperative and postoperative care, the implant, patient pathology and daily activity. It is important that surgeons obtain appropriate informed consent and discuss the potential for complications with each patient prior to surgery. This may include a review of alternative, non-implant procedures such as soft tissue reconstruction or arthrodesis. WARNING Reshaping of the implant should be avoided because it can compromise or destroy the structural integrity and the functionality of the implant. potential complications AND ADVERSE REACTIONS In any surgical procedure, the potential for complications exists. The risks and complications with the Swanson Hammertoe Implant include: Infection or painful, swollen or inflamed implant site Fracture of the grommet, the implant stem and/or the hinge Loosening or dislocation of the prosthesis requiring revision surgery Bone restoration or over-production Allergic reactions(s) to prosthesis material(s) Untoward histological responses possibly involving macrophages and/or fibroblasts Migration of particle wear debris possibly resulting in a bodily response two

Some degree of particle formation is inevitable with all implants including those made of silicone elastomer. The amount will vary with factors such as patient activity, metatarsal stability or instability postimplantation, implant position and the amount of soft tissue support. The patient s biological response to these particles is variable, but can include local synovitis and bone lysis in contiguous bones. Another potential concern with silicone implants arises from case reports in the literature suggesting an association between silicone implants and immunological abnormalities and autoimmune rheumatic disorders, although these reports have been contradicted and the association has not been proven conclusively. risk/benefit decision BY SURGEON DESCRIPTION The judgement by a surgeon to implant silicone elastomer implants is a complicated risk/benefit decision which must take into account the patient s needs and desire in addition to the surgeon s knowledge of expected results and complications as well as therapeutic alternatives. Wright Medical Technology, Inc. can provide a bibliography of silicone elastomer implants to any physician. Please write or call Wright Medical Technology, Inc. The HAMMERTOE implant (Swanson* Type) Weil Design is a double-stemmed flexible implant designed for the proximal interphalangeal joint of the lateral toes. It is used as an adjunct to resection arthroplasty in cases of moderate to severe hammertoe deformities of toes 2 through 5. The HAMMERTOE implant is made of silicone elastomer and is constructed in a rod-shaped design with a thicker mid-section spacer or collar. The implant is symmetrical, therefore, there are no proximal/distal nor lateral/medial designations. Implants are available in 7 sizes with 2 stem sizes, 6 mid-section diameters to adequately satisfy sizing requirements with most patients. Stem and mid-section size should be selected to fit the bone. Mid-section diameter should be large enough to adequately maintain cortical bone contact. Mid-section length should be adequate to fill the void formed by resection arthroplasty and maintain the desired toe length. During the healing phase, the implant is encapsulated by a functionally oriented fibrous capsule providing stability, which can assist in the prevention of the floppy toe result, lateral angulation three

deformities, or recurrence of the original deformity. In addition, the possible complications of arthrodesis (e.g., poor positioning, incomplete fusion, etc.) as well as the postoperative fixation required for arthrodesis are minimized. A sizing set, supplied nonsterile and not suitable for implantation, is available for proper size determination during surgery. An instrument set which includes a hand reamer and a hand compactor is also available in two sizes. The reamer is used to drill the medullary canal, while the compactor is used to shape the canal to match the stem of the implant. The size 1 reamer/compactor sets should be used with the sizes 1S, 1, 1W and 1L implants. Similarly the size 2 reamer/compactor should be used with the size 2S, 2 and 2L implants. ADVANTAGES general INDICATIONS Acts as a spacer to preserve joint relationship and allow appropriate capsuloligamentous reconstruction to correct deformities. Fixation in the intramedullary canal is not necessary. Available in seven sizes to adequately meet most operative requirements. Any joint implant arthroplasty requires consideration of the following general indications: Good condition of the patient Good neurovascular status Adequate skin coverage Possibility of a functional musculo-tendinous system Availability of postoperative therapy Cooperative patient Use of the HAMMERTOE implant may be considered for: Semi-rigid or rigid hammertoe deformity associated with degenerative arthritis. Semi-rigid or rigid hammertoe deformity associated with rheumatoid arthritis. Revision of a failed arthroplasty or arthrodesis. four

general CONTRAINDICATIONS Infection Physiologically or psychologically inadequate patient Inadequate skin, bone, or neurovascular status Irreparable tendon system Possibility for conservative treatment Growing patients with open epiphyses Patients with high levels of activity Each patient must be evaluated by the surgeon to determine the risk/benefit relationship. surgical PROCEDURE Wright Medical Technology, Inc. does not recommend a particular surgical technique when using the implant. Proper surgical procedures and techniques are necessarily the responsibility of the medical profession. The following procedure is furnished for information purposes only as a technique used by Dr. Lowell Scott Weil. Each surgeon must evaluate the appropriateness of the procedure based on his or her own medical training and experience. INCISION AND EXPOSURE Surgery may be performed under local anesthesia utilizing a digital block at the base of the involved digit. A total of 2cc of lidocaine hydrochloride 2% is sufficient to give adequate anesthesia. Two semi-elliptical incisions are made over the proximal interphalangeal joint of the hammertoe. The width of the semi-elliptical tissue removed corresponds to the severity of the hammertoe; the greater the deformity, the more tissue removed. The incision is carried to the extensor apparatus. Careful preservation of vascular supply is undertaken. The wedge of tissue is then excised in total. The joint capsule is opened by a transverse incision made over the dorsal aspect of the head of the proximal phalanx. The extensor tendon and apparatus is then dissected free from the head and shaft of the proximal phalanx, approximately 1 cm. The collateral ligaments of the proximal interphalangeal joint are then severed exposing the head of the proximal phalanx. five

PRE-OPERATIVE Hammertoe 2, 3, and 4 BONE PREPARATION Proper preparation of bone is very important. Bone size is small and care should be taken if power equipment is to be used. To prepare intramedullary canals for implant, the head of the proximal phalanx is resected approximately 7 to 8mm from its distal aspect. Using a wire, drill or preferably a small size Swanson Intramedullary Broach (Cat. #6480-0100) a centered, pilot hole is made by rotating the instrument into the proximal phalanx, followed by use of the Size 1 Compactor (Cat.#5431-0110) is used to compact the medullary canal and allow for an exact fit of the trial implant. The mid phalanx is prepared in a similar fashion making certain that the canal is formed along the longitudinal access of the toe. This canal opening may cross the distal interphalangeal joint into the distal phalanx in selected cases; therefore, the distal interphalangeal joint should be kept extended when drilling to maintain good position following implant insertion. All bone edges which contact the implant are left smooth, and a trial fit is made with the appropriate color coded sizer. If a larger implant is required, the canals can be enlarged using the Size 2 Reamer and Compactor (Cat. #543-0010 and Cat. #5431-0120 respectively). IMPLANT INSERTION All areas of the incision are thoroughly flushed and debris removed. The Hammertoe Implant is then placed into position using a no touch technique. The implant should be handled with blunt instruments to avoid traumatizing its surface or contamination with foreign bodies. The extensor apparatus is then repositioned and any redundant tissue is excised. The extensor apparatus is then secured under slight tension utilizing two interrupted sutures of 5-0 absorbable. 2 fi YEARS POST-OPERATIVE Hammertoe Implant toes 2, 3, and 4. Note Excellent toe alignment in spite of phalangeal regeneration. POSTOPERATIVE CARE After ten days, sutures are removed followed by bathing and flexion exercises. Patients are allowed to return to their normal footwear when tolerated. six

BIBLIOGRAPHY A bibliography may be obtained by writing Wright Medical Technology, Inc. or by contacting your Wright Medical Technology, Inc. representative. HOW SUPPLIED The Hammertoe Implant (Swanson Type) Weil Design has been sterilized and packaged as follows: TYPICAL DIMENSIONS SIZE A B C D 1S.25 ( 6.4 ).10 ( 2.5 ).36 ( 9.1 ).078 ( 2.0 ) 1.25 ( 6.4 ).10 ( 2.5 ).36 ( 9.1 ).13 ( 3.3 ) A 1L.25 ( 6.4 ).10 ( 2.5 ).33 ( 8.4 ).18 ( 4.6 ) 1W.30 ( 7.6 ).10 ( 2.5 ).36 ( 9.1 ).15 ( 3.8 ) 2S.30 ( 7.6 ).12 ( 3.0 ).36 ( 9.1 ).09 ( 2.3 ) 2.30 ( 7.6 ).12 ( 3.0 ).36 ( 9.1 ).15 ( 3.8 ) 2L.30 ( 7.6 ).12 ( 3.0 ).33 ( 8.4 ).21 ( 5.3 ) C D B SMALL STEM QUANTITY DESCRIPTION CATALOG # 1 Box 1 Each, Size 1S 431-001S 1 Box 1 Each, Size 1 431-0001 1 Box 1 Each, Size 1L 431-001L 1 Box 1 Each, Size 1W 431-001W 1 Box 1 Each, Size 2S 431-002S 1 Box 1 Each, Size 2 431-0002 1 Box 1 Each, Size 2L 431-002L 1 Sizing Set 1 Each, sizes: 441-0000 1S, 1, 1L, 1W, 2S, 2, 2L Numerically marked, color coded (non-sterile) NOT FOR IMPLANTATION. seven

HANDLING AND STERILIZATION This product has been sterilized and should be considered sterile unless the package has been opened or damaged. Remove from package, using accepted sterile technique, only after the correct size has been determined. Always handle the product with powder-free gloves, and avoid contact with hard objects that may damage the product. Handling of the implant should be done with blunt instruments to avoid surface trauma or contamination with foreign bodies. Rinse the implant thoroughly with sterile saline solution before insertion. The sizing set is supplied nonsterile. The following sequential steps are recommended to clean and sterilize the sizing set or to re-sterilize the implant or grommets: 1. Scrub thoroughly with a clean, soft-bristled brush in a hot water-soap solution to remove possible surface contaminants. Use a non-oily, mild soap. Do not use synthetic detergents or oil-based soaps, as these soaps may be absorbed and subsequently leach out to cause a tissue reaction. 2. Rinse thoroughly with distilled water. 3. If using a 270 F flash sterilization cycle, place the component on a standard mesh sterilization tray. 4. If using a 250 gravity or 270 F pulsing vacuum sterilization cycle, double wrap the component in muslin or a similar type non-woven medical grade wrapping material or place in a sealed sterilization pouch. 5. Autoclave according to the following parameters: Method Cycle Temperature Exposure Steam Gravity 250º F/121º C 30 minutes Steam Flash 270º F/132º C 10 minutes Steam Pulsing-Vacuum, 270º F/132º C 10 minutes After sterilization, remove the implant from its wrapping material/pouch or the sterilization tray using accepted sterile technique. Ensure that the implant is at room temperature prior to implantation. These recommendations have been developed and tested using specific equipment. The bioburden should not exceed 10 4 colony forming units (CFU) per device. Due to variations in environment and equipment, it must be demonstrated that these recommendations produce sterility in your environment. If processing conditions, wrapping materials or equipment changes occur, the effectiveness of the sterilization process must be demonstrated. Evidence suggests that repeated sterilization may affect the physical characteristics of the implant. Accordingly, resterilization in excess of three times is contraindicated. This product is for single use only. An implant should never be sterilized after contact with body tissues or fluids. Do NOT sterilize by ethylene oxide as the residual sterilant may cause adverse tissue reaction. CAUTION Federal (United States) law restricts this device to sale, distribution, and use by or on the order of a physician. *Swanson, Alfred B., M.D., F.A.C.S Professor of Surgery, Michigan State University, Lansing, Michigan Director of Orthopaedic and Hand Surgery Training Program of the Grand Rapids Hospitals and Director of Hand Fellowship and Orthopaedic Research, Blodgett Memorial Medical Center, Grand Rapids, Michigan. Lowell, Scott Weil, DPM, FACFS Chief of Podiatry, Highland Park Hospital, Highland Park, Illinois Chief of Podiatry, Mt. Sinai Medical Center, Chicago, Illinois Medical Staff, Lake Forest Hospital, Lake Forest, Illinois Medical Staff, Lincoln West Medical Center, Chicago, Illinois eight

Wright Medical Technology, Inc. 5677 Airline Road Arlington, TN 38002 901.867.9971 phone 800.238.7188 toll-free www.wmt.com Wright Medical Europe SA Commerce Parc Gebouw B, 6th Floor Krijgsman II 1186 DM Amsterdam The Netherlands Tel +31 (0) 205450100 2006, Wright Medical Technology, Inc. All Rights Reserved. SO STL004 Rev. 2.06