INVERTER WITH MULTIPLE MPP TRACKERS: REQUIREMENTS AND STATE OF THE ART SOLUTIONS



Similar documents
THE SUPERFLEX DESIGN OF THE FRONIUS SYMO INVERTER SERIES

EFFICIENT EAST-WEST ORIENTATED PV SYSTEMS WITH ONE MPP TRACKER

HIGH FREQUENCY TRANSFORMER WITH TRANSFORMER SWITCHOVER

PERFORMANCE OF MPPT CHARGE CONTROLLERS A STATE OF THE ART ANALYSIS

Yield Reduction due to Shading:

Application Note: String sizing Conext CL Series

8 Ways Power Optimizers are Better by Design

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

FUNCTIONS AND CAPABILITIES OF PV INVERTERS TO BE PART OF A SMART GRID

Replacing Fuel With Solar Energy

Additional Solar System Information and Resources

Application Note - How to Design a SolarEdge System Using PVsyst

SOLAR ChARge CONTROLLeRS

Design of Grid Connect PV systems. Palau Workshop 8 th -12 th April

Gross/Active PV Surface Area: ,40 / ,29 m². Energy Produced by PV Array (AC):

JSI Series Single Phase String Inverter. Features. Typical Efficiency Curve JSI-1500TL JSI-2000TL JSI-2500TL

Solar Cybertech: A Competition of Digitally Controlled Vehicles Poweredby Solar Panels

Solar Energy. Airports Going Green Aimee Fenlon

Photovoltaic Systems II EE 446/646

ADDENDUM #1(BID PACKAGE # 3)

SolarMax P series The power package for residential solar plants

K.Vijaya Bhaskar,Asst. Professor Dept. of Electrical & Electronics Engineering

Automatically created Edit using CAD tools Export to DWG

MODULAR SYSTEM OF INVERTERS FOR PHOTOVOLTAIC SYSTEM AT THE TECHNOLOGY CENTRE OSTRAVA

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Solar Kit. Complete solution to optimize your photovoltaic system

INVERTER SYSTEM PRODUCT BROCHURE

PVWATTS DERATING FACTORS FOR SOLARBRIDGE PANTHEON MICROINVERTERS AND ACPV SYSTEMS

One. Invest with confidence Smart Solar Inverter Solutions. solarinvertersolutions.com. Residential, commercial and large scale applications

Solar Solutions and Large PV Power Plants. Oscar Araujo Business Development Director - Americas

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

SolarEdge. SolarEdge, Enphase Value Comparison. July 8, 2011

RENEWABLE ENERGY LABORATORY FOR LIGHTING SYSTEMS

Residential Consumer Guide to Solar Power June 2015

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted.

SOLAR PV INFORMATION. January, 2015

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

A Stable DC Power Supply for Photovoltaic Systems

fuse.on Technical background information provided by SIBA: Know-how on Electrical Fuses

NBF. Electrical. WHY GO SOLAR? NBF ELECTRICAL EXPLAINS WHY

The energy self-sufficient family home of the future

Photovoltaic Solar Energy Unit EESFB

YSmart Technology Co.,Ltd

ENERGY STAR Market and Industry Scoping Report Solar Inverters December Executive Summary. 2. Definitions

KADUNA CLINICS SOLAR SYSTEMS PERFORMANCE TESTING

SUNNY TRIPOWER 5000TL 12000TL

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Satcon Solstice 100 kw System Solution

DC To DC Converter in Maximum Power Point Tracker

How To Increase Private Consumption

Power Electronics for Renewable Energy Integration into Hybrid AC/DC Microgrids Kai SUN Aug 27, 2015

How To Make A Fronius Cl Power Inverter

The Planning and Design of Photovoltaic Energy Systems: Engineering and Economic Aspects. William Nichols Georgia Southern University Atlanta, GA

A Design of DC/DC Converter of Photovoltaic Generation System for Streetcars

Photovoltaic system sizing report

32/1/ /PVSE(Part-II) Ministry of New and Renewable Energy SPV Off Grid Division

AC vs DC for Data Centers and Network Rooms

Residential Consumer Guide to Solar Power

New Procedure for Measuring Dynamic MPP-Tracking Efficiency at Grid-Connected PV Inverters

ABB central inverters PVS to 1000 kw

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Fundamentals of Photovoltaic solar technology For Battery Powered applications

Virginia Solar Co-op FAQs

Photovoltaic System Overcurrent Protection

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

Photovoltaic (PV) Energy as Recharge Source for Portable Devices such as Mobile Phones

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

Solar Cell Optimization: Cutting Costs and Driving Performance

Designing PV Plants Optimised for Economic Efficiency

CHANGING THE WORLD WITH COMPELLING IDEAS. German Indian Renewable Energy Dialogue 1st of October 2008

Stand Alone PV System Sizing Worksheet (example)

Mohamed First University Faculty of Science, dépt de Physique, laboratory LETAS, Oujda, Maroc. (2)

Performance and Reliability Evaluation of CPV Systems

Solar PV Panels. A talk by Ham and Petersham Street Champions

Using the sun to generate electricity

Submittal Requirements for Solar Photovoltaic Installations 10 kw or Less in One and Two Family (Duplex) Dwellings

FREE ONLINE APPLICATION OF CALCULATION

Towards a more efficient energy use in photovoltaic powered products

PHOTOVOLTAIC SYSTEMS. Alessandro Massi Pavan

Consumer guide. be brighter. actewagl.com.au/solar

An Isolated Multiport DC-DC Converter for Different Renewable Energy Sources

/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready

DELIVERING BUSINESS ENERGY GO GREEN AND SAVE MONEY

BUILDING CODE MANUAL COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS BUILDING AND SAFETY DIVISION Based on the 2014 LACBC

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

PID - The Problem and How to Solve It

Solar Matters III Teacher Page

Corona Department of Water & Power (DWP) Solar Partnership Program Guidelines and Application

New energy leads low carbon life.

INTERFACES FOR RENEWABLE ENERGY SOURCES WITH ELECTRIC POWER SYSTEMS

Building Integrated Combined Solar Thermal and Electric Generation Demonstration Project at Concordia University

1 Table of Contents SolarEdge Site Design Tool

How To Use The Csi Ebpp Calculator

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

ANALYSIS 2: Photovoltaic Glass Replacement

HYBRID POWER SYSTEMS for TELECOM applications

Transformerless PV inverter withstandardsystem monitoring. Fronius IG TL

PV-Lifeline Safety in case of danger

Transcription:

INVERTER WITH MULTIPLE MPP TRACKERS: REQUIREMENTS AND STATE OF THE ART SOLUTIONS ABSTRACT: For most people inverters with multiple MPP Trackers (MPPT) seem to be more flexible compared to inverters with a single MPPT. At first glance this assumption appears to be correct, however, the devil is in the detail. The purpose of this project is to show that not every inverter with multiple MPPT s is automatically usable for each application. There are high requirements on such an inverter which must be fulfilled to be as flexible as always assumed. 1 Introduction Inverters with multiple MPP Trackers should be usable for different applications. Firstly, perfect system configuration must be possible. That means each number of PV modules which results from different system sizes must be configurable. Secondly, to minimize energy losses, further applications are: shaded PV systems and PV systems with different module orientation. These are in principle the main applications for inverters with multiple MPP Trackers and the crucial question is: Are inverters with multiple MPP Trackers suitable for all of these applications? 2 Multistring The requirements of an inverter with two MPP Trackers are explained in the following text. Figure 1 indicates a simplified block diagram: each string has its own DC/DC converter with a separate MPPT for operating the respective string or string bundle at its maximum power. MPPT MPPT ~ Figure 1: Block diagram of an inverter with two MPPT s The key factor for such an inverter to be useful for the mentioned applications in chapter 1 is the DC power capability of each MPPT. As shown in Figure 2, the DC power capability on the main input (MPPT1) must be 100% over an appropriate MPP voltage range the same as it is for a normal string inverter. If the maximum DC power capability on MPPT1 would be lower than 100% then the installer could be forced to mix up PV modules on the second input (MPPT2) which are not exposed to the same conditions. For example, a maximum provided DC power capability of 70% on MPPT1 in a PV system in which 10% of PV modules are shaded would result in energy losses. However, that should be originally minimized with an inverter with two MPP Trackers. 04/2013 1/7

DC power capability MPPT1 Figure 2: Required DC power capability of MPPT1 As can be seen in Figure 3, for MPPT2 a maximum DC power capability of % is sufficient also in that case the MPP voltage range must be wide enough. % DC power capability is required, for example, in an East/West orientated PV system with a 1:1 power separation % DC power on the east roof and % DC power on the west roof. DC power capability MPPT2 Figure 3: Required DC power capability of MPPT2 Additionally, for both MPP Trackers an extended MPP voltage range with decreasing DC power capability is required to get more flexibility in system configuration and a better performance for shaded systems or systems with different module orientation. With such a design the inverter would be useful for each application but has the disadvantage of high costs due to oversizing. 3 State of the Art Solutions First of all, there are some inverters with multiple MPPT s available on the market, which closely meet the requirements explained in the previous chapter. Those inverters have in principle no significant problems concerning the applications mentioned in chapter 1. But there are also some inverters with multiple MPPT s currently available which do not fulfil the requirements. An example of an inverter with two MPPT s is shown in Figure 4. As can be seen, both MPP Trackers MPPT1 and MPPT2 have the same DC power capability of 58% over a certain MPP voltage range. This means that the requirements on the inverters DC power capability aren t fulfilled. 58% is in fact sufficient for MPPT2 but insufficient for MPPT1. What consequences this has is explained later in chapter 4 and chapter 5. Moreover, 04/2013 2/7

the minimal MPP voltage (V MPP/MIN ) is specified at a lower DC power capability than P MAX which can cause misunderstanding or wrong V MPP calculations. Therefore V MPP/MIN should be specified at P MAX as the arrow shows in Figure 4. DC power capability MPPT1, MPPT2 Figure 4: DC power capability of MPPT1 and MPPT2 of an inverter with two MPPT s In comparison, in Figure 5 the required DC power capability of MPPT1 (100%) over an appropriate input voltage range is shown. As can be seen, the difference between the required DC power capability and the actual one is significant. DC power capability MPPT1 Figure 5: Required DC power capability of MPPT1 with the appropriate MPP voltage range compared to the provided DC power capability Additional to that example, Table I shows some more inverters with two MPP Trackers that are available on the market. As can be seen, all four inverters have the same DC power capability on both inputs. The minimum requirement of % DC power capability on MPPT2 is fulfilled by every inverter. However, MPPT1 is always undersized which have consequences regarding the mentioned applications: perfect system configuration, shaded or different orientated PV system respectively. Furthermore, MPPT2 is mainly oversized with the exception of inverter D. 04/2013 3/7

Table I: Examples of inverters with two MPPT s Percentage of the maximum DC power capability of each MPPT Inverter M PPT1 M PPT2 A 62% 62% B 58% 58% C % % D % % 4 Perfect System Configuration For perfect system configuration a maximal DC power capability of 67% on the main input (MPPT1) and % on the second input (MPPT2) is at least necessary. These are the minimum requirements for the installation of even and uneven strings to the inverter. 67% on MPPT1 is demanded for the installation of three strings two strings on MPPT1 and one string on MPPT2. In the case of even strings the maximum DC power capability necessary on MPPT2 is %. Moreover, parallel operation of MPPT1 and MPPT2 must be possible for the installation of 1string PV systems. As shown in Table I, the required 67% DC power capability cannot be achieved by any inverter which results in restrictions concerning the system configuration. First of all, there are restrictions with standard crystalline PV modules that means that modules with common 5 and 6inch solar cells are partly not configurable. And secondly, the system design with three strings is mainly not possible as mentioned above, for three strings a maximal DC power capability of 67% on any input is required. A comparison between an inverter with two MPPT s (inverter B see chapter 3, Table I) and an inverter with a single MPPT is shown in Table II. In that example the system configurations were carried out with a standard crystalline PV module with an MPP current of 7.A at STC conditions. Both inverters had the same nominal AC power of 10kW and since the installation of the PV modules shall be flexible a system dimensioning from 5% to +20% with regard to P DC/MAX (P DC/MAX P AC /Efficiency of the inverter) was also considered from the system dimensioning, results the different number of PV modules. As can be seen, the number of possible system configurations using the inverter with two MPPT s does not meet the expectations. For both inverter types five different number of PV modules can be installed. Hence, there is no advantage for the inverter with two MPPT s regarding system configuration compared to the inverter with a single MPPT. At that point it should also be noted that the inverter with two MPPT s is just partly applicable for the other applications, in fact in three cases only. This will be handled in greater detail in the next chapter. Table II: Comparison between the inverter with two MPPT s that maximum DC power capability is 58% for each MPP Tracker and the inverter with a single MPPT regarding system configuration. Five numbers of PV modules can be installed with each inverter. Separated strings can be installed to the inverter with two MPPT s with just three numbers of PV modules. The number of strings is higher at the inverter with a single MPPT due to higher open circuit voltage. 04/2013 4/7

System dimensioning 56 System dimensioning 56 Inverter B with two MPPT's 2x23 // 1x23 + 1x23 // 1x24 + 1x22 1x24 + 1x23 2x24 // 3x16 // 1x24 + 1x24 3x17 3x18 Inverter with a single MPPT 4x12 5x10 4x13 5x11 4x14 In summary it can be concluded, that an inverter with a single MPP Tracker and with a well suited MPP voltage range has no disadvantages compared to an inverter with two MPPT s which DC power capabilities do not meet the explained requirements. 5 PVSystems and PVSystems with different Module Orientation Further applications for inverters with multiple MPPT s are shaded PV systems and PV systems with differing module orientation. The requirements to be useful for these applications are even higher compared to those explained in the previous chapter. The DC power capability on MPPT1 must be 100% on MPPT2 % DC power capability is adequate. All four inverters shown in Table I (see chapter 3) do not fulfil the requirements. Therefore these inverters can be used only to a limited extent for shaded PV systems or systems with differing orientations. An example with inverter C is shown in Table III. The following factors were considered to calculate possible system configurations: I MPP/STC of the PV module 8.5A; AC power of the inverter 10kW; system dimensioning from 5% to +15% with regard to P DC/MAX (P DC/MAX P AC /Efficiency of the inverter). As can be seen, four different numbers of PV modules can be installed. Since MPPT1 is undersized, the following restrictions are obvious concerning shaded PV systems and different orientated PV systems: Firstly, the usage of the inverter in a shaded PV system or PV systems with different module orientation is only possible in just two cases with PV modules and with PV modules. Secondly, the inverter with two MPPT s is not as flexible as expected because a 3:1, 3:2 or 4:1 string separation is not possible. Moreover, with the shown system design for PV modules and PV modules mismatching losses can occur if just one string or a few PV modules are shaded or of differing orientation. 04/2013 5/7

Table III: Possible system configurations using inverter C with two MPPT s System dimensioning Inverter C with two MPPT's 2x12 + 2x11 4x12 // 2x12 + 2x12 5x10 5x11 Consequently, the last two chapters have shown that not every inverter with two MPP Trackers is automatically useful for every application as is always assumed. In comparison, in Table IV the possible system configurations with a 10kW AC inverter with a single MPPT are shown the factors used for the system configurations were similar to those before. As can be seen, the numbers of PV modules which can be installed are similar compared to the inverter with two MPPT s. Of course, a string separation is not possible but this is not always necessary. The installation of inverters with single MPP Tracker in eastwest orientated PV systems is a good option and can provide an attractive alternative compared to inverters with multiple MPPT s [1][2]. Table IV: Possible system configurations with an inverter with single MPPT System dimensioning Inverter with a single MPPT 4x12 5x10 4x13 5x11 6 Conclusion The findings of several analyses of inverters with multiple MPP Trackers are briefly summarized in the following paragraphs. Investigated state of the art solutions have shown that inverters with multiple MPP Trackers have restrictions regarding: / Perfect system configuration / Shaded PV systems / PV systems with different module orientations 04/2013 6/7

Inverters with a single MPPT have often no disadvantages regarding system configuration compared to inverters with multiple MPPT s. Inverters with multiple MPP Trackers must fulfil high requirements. Misleading datasheet information could lead to poor system configurations. In conclusion, many inverters with multiple MPPT s do not keep their promises regarding system configuration, shaded PV systems and PV systems with different module orientations. 7 Reference / [1] Efficient EastWest orientated PV Systems with one MPPTracker, 25th European Photovoltaic Solar Energy Conference, Spain, 2010 / [2] Auslegung von PVAnlagen im PolystringBetrieb Eigenverbrauchsoptimierung vs. MismatchVerlust, 27. Symposium Photovoltaische Solarenergie, Bad Staffelstein, 2012 Characters (no spaces): 9,894 Words: 1,930 Enquiries: Editor: Dietmar Staudacher, +43 (664) 82427, staudacher.dietmar@fronius.com, Froniusplatz 1, 00 Wels, Austria. Trade press: Andrea Schartner, +43 (664) 886765, schartner.andrea@fronius.com, Froniusplatz 1, 00 Wels, Austria. 04/2013 7/7