O-Z Care System. Model PF03



Similar documents
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

MATERIAL SAFETY DATA SHEET "LIQUID FIRE" DRAIN LINE OPENER 09/2007 PHYSICAL/CHEMICAL CHARACTERISTICS:

MATERIAL SAFETY DATA SHEET DATE: 2009, revised July 2011 PRODUCT NAME: BOSTON BRAKE & PARTS CLEANER PRODUCT CODE: 78200

SAFETY DATA SHEET. Mouse Microphage Microsomal Immunoblot Control


Uses No Chemicals. Ozone Reverts Back to Oxygen. Eliminates Odor Electronically. Operates Unattended. Retards Bacterial Growth. Rapid Removal of Odors

SAFETY DATA SHEET Glen-Pak TM DNA purification cartridge (for use with disposable syringes) xx

22 APR 2010 <MSDS_ID>300088</MSDS_ID> MATERIAL SAFETY DATA SHEET. <Product> PHENOLPHTHALEIN INDICATOR SOLUTION # HR </Product> Part#: N/A

Technical Data Sheet

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET. MSDS #: FH/H/2003/TWTA-5HRJZ8 Issue Date: 09/12/2011 Supersedes: Issue Date: 07/2007

TRICHLOROACETIC ACID SOLUTION Department of Pharmacy Duke University Medical Center Box 3089 Durham, NC

MATERIAL SAFETY DATA SHEET Page 01 of 05

SECTION 1: IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING SECTION 2: HAZARDS IDENTIFICATION EMERGENCY OVERVIEW

MATERIAL SAFETY DATA SHEET

1. Chemical Product and Company Identification. 2. Hazardous Ingredients

MATERIAL SAFETY DATA SHEET FOR OZONE GAS Ozilla Ozone Sterilizer SECTION 1. CHEMICAL IDENTIFICATION

EMERGENCY PHONE: or (651) (24 hours)

Safety Data Sheet for Whole Grain

Issue Date: 01-Sep-2012 Revision Date: 23-Apr-2014 Version 1 1. IDENTIFICATION. Slide Veri-Kleen Contact Cleaner 2. HAZARDS IDENTIFICATION

MANUFACTURER: RTP COMPANY Information Phone: EAST FRONT STREET Emergency Phone: WINONA MN 55987

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET.alpha.-pyrrolidinopentiophenone (hydrochloride)

NFPA Hazard Class: * Physical Form: Solid. Health: 0 (Least) * Appearance: Yellow Flammability: 1 (Slight)

SAFETY DATA SHEET FILE NO.: , DRY CIDER VINEGAR SDS DATE: 05/05/15

MATERIAL SAFETY DATA SHEET

Seahorse Bioscience SAFETY DATA SHEET

SAFETY DATA SHEET Enz-Extract Enzyme Carpet Extractor. 1. Product and Company Identification. 2. Hazards Identification

3M Flip-Top Dilution Bottle - Peptone Water (formerly Biotrace Flip Top Dilution Bottles, 99ml Peptone Water) 07/31/15

Section 1: Identification. GLO GERM POWDER All colors

MATERIAL SAFETY DATA SHEET WWF of 5 1 Gal Xtreme Blue -20 Windshield Washer Fluid. 121 Landmark Drive Greensboro, NC 27409

Carpet Seam Sealer 8200

MATERIAL SAFETY DATA SHEET MSDS No.: 003 Revision No.: 5 Effective Date 2/2/2015

Page Number:

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET KRC-7 Bathroom Cleaner & Restorer SECTION 1 PRODUCT NAME AND COMPANY IDENTIFICATION

************************************************************************ *** SECTION 1 PRODUCT IDENTIFICATION

SECTION I - MANUFACTURER IDENTIFICATION SECTION II - HAZARDOUS INGREDIENTS/SARA III INFORMATION OCCUPATIONAL EXPOSURE LIMITS OSHA PEL

SAFETY DATA SHEET (±)-Anatoxin A (fumarate) Section 2. Hazards Identification

Main Drain Opener Safety Data Sheet

EMERGENCY PHONE: or (651) (24 hours)

SAFETY DATA SHEET. Trade name: Master Clear Seal-5 Revised: 5/29/2015

TREMPRO 638 SSL GRAY - 15 SSG CS Version 3. Print Date 12/22/2011 REVISION DATE: 12/20/2011

SAFETY DATA SHEET Rivaroxaban. Section 2. Hazards Identification

SAFETY DATA SHEET For Coatings, Resins, and Related Materials

Safety Data Sheet SECTION 2: HAZARDS IDENTIFICATION

* * * EMERGENCY OVERVIEW * * * High pressure gas. Can cause rapid suffocation. Can increase respiration and heart rate.

SAFETY DATA SHEET. 955 Connecticut Ave, Suite 5202 Bridgeport, CT Tel: Date Prepared: July 22, 2015

Section 1 Chemical Product and Company Identification Product Name : Power Hydrol HLP 32. Chemical Family : Refined Paraffinic Petroleum Distillate.

Alaska. Occupational Safety and Health Standards. quick guide to. hazard communication for general industry. What you should know and not a word more!

MATERIAL SAFETY DATA SHEET

Emergency Phone Numbers: P.O. Box 1950 CHEMTREC: 800/ Brewster, New York POISON CENTER: 800/ /

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet

Independent Forensics of Illinois

CAS NO. A >94.19 % WT >94.19 % VOL SARA 313 NO

Lake Restoration Inc Ironwood Circle Rogers, MN 55374

Product: EZ-Zyme Enzymatic Cleaner (REF 3-750, 3-755) Revision Date: 03/23/2015 SECTION 3 COMPOSITION / INFORMATION ON INGREDIENTS

=========================================================================== Section 1 PRODUCT AND COMPANY IDENTIFICATION

BIO BASIC INC. 20 KONRAD CRES, MARKHAM ONTARIO L3R 8T4 CANADA TEL: (905) , (800) FAX: (905)

Safety Data Sheet SKINTEGRITY HYDROGEL

1. IDENTIFICATION. US IVD HCCA, portioned BD Bruker US IVD HCCA, Portioned

CHAPTER 12 Occupational Safety & Health and Environmental Protection Programs

MATERIAL SAFETY DATA SHEET FILE NO.: B ZOOM Drain Care System (Liquid Drain Opener) MSDS DATE:9/17/08

MATERIAL SAFETY DATA SHEET Page 1 of 7 Revised 1/17/01 BRIJ 35 SP Replaces 2/22/99 UNIQEMA As of 2/16/01. Material Name: BRIJ(R) 35SP

WINDEX ORIGINAL GLASS CLEANER

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

APPLIED PETROCHEMICAL RESEARCH

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Not applicable 3.2. Mixture

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET Page 1 of 5 DURAFIX Solder for Aluminum, Diecast, Zinc Alloys, Pot Metal and White Metal

MATERIAL SAFETY DATA SHEET

Safety Data Sheet Avesta Neutralization Agent 502

: Resin Fibre Discs - Aluminum Oxide, Zirconia Alumina

Material Safety Data Sheet BZK Antiseptic Towelettes / Wipes

SAFETY DATA SHEET JWH 081. Section 2. Hazards Identification

Yeast Extract. MO BIO Laboratories, Inc., , M-F 8:00AM-5:00PM PST. Chemical Name CAS No. % Other Identifiers

Material Safety Data Sheet

Material Safety Data Sheet. Chemical Product and Company Identification Product Name or Number:

Calendula Extract Safety Data Sheet

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET Consumer Product

PRODUCT SAFETY DATA SHEET Product name: SOFT LEAD PRODUCTS

Material Safety Data Sheet

Material Safety Data Sheets (MSDS), Spill Clean-Up

SECTION 1 - PRODUCT IDENTIFICATION

SAFETY DATA SHEET , , , , , , , ,

Chemical Reducing Solution CRS

Material Safety Data Sheet Ampicillin, sodium salt MSDS

OFF! DEEP WOODS SPORTSMEN INSECT REPELLENT I (PUMP SPRAY)

MSDS Material Safety Data Sheet STATUS Controlled

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET Confirms to OSHA Hazard Communication Standard (CFR ) HazCom 2012

Material Safety Data Sheet

3M MATERIAL SAFETY DATA SHEET NO. 4004, 4008, 4026 AND 4032 DOUBLE COATED URETHANE FOAM TAPE 07/29/2002

Material Safety Data Sheet

Transcription:

OPERATORS MANUAL AND PARTS LIST Model PF03 READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE WARNING: USE IN UNINHABITED AREAS ONLY. Ozone attacks organic matter. Limited exposure can cause nausea. Prolonged exposure can be hazardous. Prolonged exposure can also affect certain organic materials such as rubber, plastic, wire insulation. Do not get machine wet. Consult MSDS sheet before use. WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT. X8728

O-Z Care System the Professional Odor Neutralizer Not a simple cover-up or ionizer, the O-Zone unit is an economical environmental odor neutralizer that actually destroys the source of the odor and leaves pure, fresh oxygen in its place. This large-capacity ozone generator is ideal for commercial use, eliminating odors in any indoor location and in vehicles. It is excellent for removing odors caused by smoke damage, mold, mildew, pets and other sources commonly encountered in building maintenance and refurbishing. Use the O-Zone unit in basements, kitchens, bathrooms, and any room with an odor problem. It also provides rapid deodorizing of hotel/motel rooms, meeting rooms and vehicles such as automobiles, buses, boats and aircraft. Your O-Z Care System is complete and ready to operate. Unpacking the O-Z Care System Your O-Z Care System was thoroughly inspected, tested, and packaged to deliver the equipment is good operating condition. It is beyond our control after the equipment is turned over to a freight carrier. The freight carrier received and signed for the equipment in good condition. Consequently, it is most important to protect your interest by carefully complying with the following instructions. Please inspect your cartons for any damage (including concealed damage) that might have occurred during shipment. Any damage is the responsibility of the freight carrier and should be reported immediately. It is your responsibility to issue a claim and to receive compensation from the freight carrier for any damage done in transit. Shipping damage is not warranted. GENERAL INSTRUCTIONS All cleaning and maintenance work should be completed and thoroughly dry before using the Ozone machine. Ozone treatment should be the final step in maintenance. Follow these easy step-by-step instructions to ensure proper operating performance of your new O-Z Care System. 1. Make certain all people; pets, and plants are out of the area. Close all windows and doors. Place a safety sign on the door to the location warning of Ozone use DO NOT ENTER 2. Make sure the filter in front of the cooling fan is installed and clean. 3. Place the ozone unit on a shelf or tabletop as high in the area to be treated as possible. 4. Plug the power cord into a grounded, 3-prong outlet. 5. Set the timer to the desired length of time. Pressing the UP timer button for 1 second will increase the time setting by 1 minute at a time. Hold the button for 1 to 3 seconds to change the time value by 2 minutes per second. Hold the button for longer than 3 seconds and the time setting will change by 20 minute increments. The maximum time setting is 29:59 hours. After reaching the maximum time, the timer will wrap back to Page 1 00:00 and continue increasing. When the time is being decreased and reaches 00:00, it will wrap to 29:59 and continue decreasing. 6. Select the desired power level: 25%, 50%, 75% or 100%. The ozone unit always sets to 100% when it is plugged in. Best results are achieved when a lower power setting is used for typical odor problems. When the power level is set to 100%, the unit will make ozone continuously until the timer runs out or the OFF button is pressed. At other power level settings, the unit will produce ozone for the fraction of a minute the level is set at. For example, if the output level is set to 75%, the O-Z system will produce ozone for 45 seconds of each minute. At 50%, ozone will be created for 30 seconds of each minute, and at 25%, the ozone generation only will occur for 15 seconds of each minute. On any setting other than 100%, the ozone generator will be cycling the ozone ON and OFF. The setting used is based on the size of the area to be treated. For example, when treating a small room with a minimal odor problem the best results are achieved by using a lower setting and at double the prescribed time. (50% power level for 60 minutes.) For larger rooms or rooms that require a heavy treatment, such as fire damage or flooding, best results are achieved with a 100% power level for the maximum time. Press the ON button to turn the O-Z system on. Leave the area. 7. When treatment is complete, unplug the ozone unit and ventilate the area completely until the smell of ozone is gone. DO NOT allow people, pets or plants back into the area until all smell of ozone is dissipated. NOTE: For best results using the O-Z Care System run a PD2500 Dryer/Air Mover in the room at the same time as the O-Z System. Ozone is heavier than air and will fall to the bottom of the room, which is why the O-Z System is placed at the highest available point in the room. Angling the Dryer/Air Mover at a 45 degree angle, pointed towards the wall will create a circular air movement for more effective treatment. Save These Instructions

Time Guidelines The O-Z Care System will control biological contamination and odor in areas up to 40,000 cubic feet. Recommended times for treatment are based on 3 air changes. To calculate the appropriate time treatments use the following calculation: (x cubic feet 100 CFM) x 3 = time setting example: (1000 cubic foot room 100) x 3 = time setting 10 x 3 = time setting 30 minute = time setting Automobiles 1. Install the hose onto the electrode chamber. Secure the hose with the hose clamp. 2. Use a towel to protect the car s finish and set the ozone unit on top of the car. 3. Install the foam block into a partially closed car window and insert the hose into the hole in the foam. 4. Set the timer and the power level. 5. Turn the ozone unit ON. Leave the area. 6. When the treatment is complete, ventilate the car completely until the smell of ozone is gone. Repeat treatment if necessary. Use the following times as a guideline: Fire & Flood Restoration Hotel/Motel Room Vehicle 12-72 Hours 20-60 Minutes 20-30 Minutes Note: Ozone destroys odor-causing molecules, thus eliminating the source of the odor. The length of time this process takes will vary depending on the amount of contaminants the ozone has to work on, the amount of area being treated. The ozone process can produce a haze in the air within the area being treated. Features & Specifications: Destroys the source of the odor: Not just a coverup or ionizer Removes odors: Caused by smoke, pets, mold, mildew, etc. 30 hour digital timer/programmer Variable ozone output settings High density: Ceramic & stainless steel electrodes (patented) Power supply overload protection Odor & biological control: For areas up to 40,000 cubic feet (1,113 M 3 ) Fire restoration: 4,000 Cubic Feet (113 M 3 ) Garbage bins: 0-8 Cubic Yards (0-2 M 3 ) Output: 7.95 ppm / 2.65 gr/hr, 100 CFM Rugged construction: Rotational molded hexane co-polymer body with lifetime guarantee Dimensions: 8 H x 8 W x 22 L Weight: 12.5 Ibs. Made in the USA No plates or UV tubes to maintain Warranty: 2 year with Lifetime Warranty on Ozone Electrodes (patented) Save These Instructions Page 2

ref # description part no 1 Housing OZ-1 2 Mounting Plate, Bottom OZ-18 3 Bolt, 3/8 x 1/2 326 4 Terminal Block OZ-10 5 Stud, 3/8 x 1 1/8 327 6 Safety Switch OZ-8 7 Circuit Breaker 1/2 Amp. OZ-5 8 Bolt 364 9 Nylon Lock Nut, 10-32 17 10 High Voltage Electrode Chamber FP242 10A Electrode Assembly FP241 11 Hose Clamp 198 12 Fan 2014 13 Lock nut 324 ref # description part no 14 Fan Cover Assembly (includes filter) 201 5A 15 Fan Filter 2015B 16 Bolt, 8/32 x 2 1/2, S/S 323 17 Screw, 4-40 x 5/8, SIS 328 18 Bracket for Safety Switch OZ-22 19 Nylon Lock Nut, 4-40, S/S 18 20 Transformer OZ-4 21 Power Cord, 6 OZ-11 22 Cord Retainer 230 & 230A 23 Control Board Assembly OZ-17 24 Membrane Key Pad OZ-20 25 Gasket OZ-1 6A 26 Bezel OZ-16 27 Label OZ-23 Conditional Guarantee The manufacturer warrants that products manufactured are free from defects in material and workmanship under normal use and service for a period of one year from date of purchase provided such goods are installed, operated and maintained in accordance with written manuals and/or other instructions. We will repair or replace without cost, any part of the unit, which when examined by our authorized repair station or at our factory, is found to be legitimately defective. This guarantee is null and void on any part which has been subject to alteration, accident, abuse or misuse. The guarantee is valid only to the original using purchaser. A Tacony Company 3101 Wichita Court Ft. Worth, TX 76140-1755

MATERIAL SAFETY DATA SHEET (MSDS) 24 HOUR EMERGENCY PHONE: 1-800-424-9300 Name: OZONE Product: Triatomic Oxygen Issued: 12/01/00 SECTION 1 - IDENTIFICATION Chemical Name: Triatomic Oxygen Chemical Family: Gas DOT Hazard Class: DOT Identification: SECTION 2- HAZARDOUS INFORMATION Component CAS # % PEL TLV Ozone Gas 10028-15-6 0.1ppm SECTION 3- PHYSICAL DATA Appearance and Odor: Colorless gas, pungent odor. Minimum detectable odor at 0.02 ppm. Boiling Point: 112 C Vapor Pressure: Vapor Density (air +1): Solubility,v in Water: Specific Gravity (H20 = 1): 1.6 g/l (liquid) Melting Point: 192 C Evaporation Rate (H20=1): SECTION 4 - FIRE & EXPLOSION DATA Not flammable, but enhances combustion of other substances to cause fire or explosion. Flash Point: Flammable Limits: LEL: UEL: Fire Extinguishing Media: Use the extinguisher appropriate to burning material. Special Firefighting Procedures: None Unusual Fire Hazards: Increased oxygen can feed fire. Explosion Hazards: None SECTION 5 - REACTIVITY DATA Stability: Unstable. Begins to dissipate immediately. Conditions to Avoid: Incompatibility: High levels for extended periods will cause deterioration of rubbers, paint and metal. Hazardous Decomposition: Hazardous Polymerization: None Disclaimer: The information in this document applies to workplace exposure and is not designed for the population at large. Any generalization beyond occupational exposures should not be made. A Tacony Company 3101 Wichita Court Ft. Worth, TX 76140-1755 SECTION 6 - HEALTH HAZARD DATA Health Hazards: Irritation of the eyes and respiratory tract. Inhalation of the gas may cause lung edema or asthmatic reactions. Symptoms may not become noticeable for several hours. Lungs may be affected by repeat or prolonged exposure. Carcinogenicity: None known. Medical Conditions Aggravated by Exposure: Methods of Exposure: Inhalation and contact on skin and eyes. Symptoms of Exposure: Cough, dry throat, irritated eyes, headache. Possible asthma-like symptoms with overexposure. EMERGENCY FIRST AID: Eye and Skin: Inhalation: Ingestion: Move to fresh air. Move to fresh air. Seek medical attention if asthma-like symptoms are noticed. SECTION 7 - PRECAUTIONS FOR SAFE HANDLING & USE Storage and Handling: Spill Response: Waste Disposal: Other Precautions: EPA Recommended Exposure Limits: 0.1 ppm / 8 hrs or maximum 0.3 ppm for 10 mins. NOTE: Threshold limit values refer to airborne concentrations of ozone and represent conditions under which it is believed that nearly all workers may repeatedly be exposed day after day without adverse effect, however a small percentage of workers may experience discomfort at levels below those listed. SECTION 8 - CONTROL MEASURES This gas is designed to be used for a limited time in a controlled environment. Eye Protection: Ventilation: Respiratory Protection: Protective Clothing or Other Equipment: Work/Hygienic Practices: None When treatment is complete, ventilate the area completely until all smell of ozone is gone. Do not allow people or pets into the area until the ozone smell is eliminated. Do not use in inhabited spaces. Clear all people, animals, plants and any other organic life from the area to be treated. None Not Available at Date Issued NFPA HAZARD RATING 4 = EXTREME 3 = HIGH 2 = MODERATE 1 = SLIGHT 0 = INSIGNIFICANT